Search PubMed⌕ Search

Biomedical subjects

S Leadbeatter

Publications and source records attributed to S Leadbeatter.

At least 19 recordsLinked to original sources

Subdural haemorrhage sustained in a baby-rocker? A biomechanical approach to causation.

An unconscious 8 weeks old infant was admitted to hospital and found to have bilateral, subdural and retinal haemorrhages. He died the following day. The explanation for the subdural haemorrhage put forward by his carers was that the infant had been in a baby-rocker and that the carers had seen the rocker being rocked vigorously by their 14 months old daughter on two separate occasions. This paper describes the biomechanics of an infant model in the particular baby-rocker used and determines the maximum forces generated, comparing them with the 'forces' thought to be compatible with the causation of subdural haemorrhage.

Biomechanical Phenomena↗

The potential and limitations of utilising head impact injury models to assess the likelihood of significant head injury in infants after a fall.

The use of engineering principles in assessing head injury scenarios is of increasing significance in investigations into suspected child abuse. A fall scenario is often given as the history for a head injury to an infant. This paper addresses the basic engineering principles and factors to be considered when calculating the severity of a head impact after free-fall. The application of head injury models (HIMs) to ascertain the forces involved in childhood head injuries from impact is also discussed. Previous studies including Duhaime et al. [J. Neurosurg. 66 (1987) 409] and Nokes et al. [Forensic Sci. Int. 79 (1995) 85] have utilised HIMs for this purpose: this paper reviews those models most widely documented.The HIM currently considered the 'state-of-the-art' is the head injury criterion (HIC) and it is suggested that this model should be utilised for assessing head impact injury in child abuse cases where appropriate.

Acceleration↗

A biomechanical reconstruction of a wound caused by a glass shard--a case report.

During the course of a criminal trial, an investigating pathologist is commonly asked how much force was required to produce an injury. This subjective opinion is based on the pathologist's previous experience of dealing with wounds inflicted with similar weapons. However, in the case of stab wounds inflicted by broken glass, it is unlikely that two glass fragments would be physically similar. In the case studied, two theories were examined: that a wound resulted from a thrown glass fragment or that it had been caused as a stab injury by the glass held in the bare hand. The investigation involved quantifying the energy required for human tissue penetration, comparison of sharpness, a biomechanical analysis of throwing actions and testing of the hypothesis that if the glass shard were used as a stabbing implement it would result in a cut to the hand.The investigation utilised a scientific methodology that reduced the need for speculative (though informed) opinion from the pathologist by producing quantitative results.

Biomechanical Phenomena↗

A novel approach to forensic investigation: three-dimensional kinematic and kinetic motion analysis.

Following a domestic incident, a five-year-old child was pronounced dead on arrival at hospital. The subsequent post-mortem examination found that the cause of death was peritonitis as a result of a rupture of the duodenum. During the police interview, the main suspect alleged that the injury occurred whilst playing a game which involved standing on the child's abdomen and chest. A reconstruction of the game was performed using 3-dimensional kinematic and kinetic motion analysis to investigate the feasibility of the statement as described by the defendant. Presented is a summary of the investigation together with a description of kinematic and kinetic methods employed.

Journal Article↗

Dynamics of stab wounds: force required for penetration of various cadaveric human tissues.

It is often said that once the skin has been penetrated no further force is required to produce penetration of underlying tissues. This experimental study has used technology which was not available to earlier investigators to examine this issue in detail. The results confirm the importance of skin penetration but indicate that the penetration of other tissues may also require significant force.

Adipose Tissue↗

Impact characteristics of two types of police baton.

A comparison study of the American style ASP extendible police baton with the conventional UK police wooden truncheon was performed. It was found that the ASP baton generated approximately twice the contact pressure than the conventional wooden truncheon. A discussion on the medical/legal aspects of the results are given.

Biomechanical Phenomena↗

The mechanics of stab wounding.

The dynamics of stab wounds were investigated using a load cell connected to microcomputer-based measuring equipment. Two types of knife blade were attached to the load cell to assess the characteristics of stab wounds caused in pig tissue. The results show that as the blade progresses through the tissue it is resisted mostly by the skin, but a significant secondary resistance exists in the deeper muscle layers.

Animals↗

The immunocytochemical demonstration of a relative lack of nerve fibres in the atrioventricular node and bundle of His in the sudden infant death syndrome (SIDS).

Whilst examining the variation with age of the nerve fibre content of the cardiac conduction system (CCS), using an immunocytochemical approach, it became evident that in two sudden infant death syndrome (SIDS) cases there was a selective lack of S100 positive nerve fibres in the atrioventricular (AV) node and His bundle. In the present study therefore, the examination of CCS with S100 was extended to a further five SIDS cases and three cases of sudden explained death. Also, in addition to S100--which selectively marks Schwann cells associated with both myelinated and non-myelinated nerves--PGP 9.5 (protein gene product) was used to reveal the presence of nerve axonal elements associated with the CCS. The results showed a uniform presence of S100 and PGP 9.5 positive nerve fibres in the sinoatrial (SA) node, the AV node and His bundle tissue of all three control cases. In contrast, five out of seven SIDS cases showed a uniform lack of staining with these markers in the AV node and His bundle tissue, whilst in the two remaining cases it was present in greatly diminished amounts. Staining in the SA node, although present in all seven cases, was reduced when compared with the control cases. This is the first time the CCS of SIDS cases has been studied with immunocytochemical markers of nerve elements. The overall results taken in conjunction with the epidemiology of SIDS suggest that the lack of AV node and His bundle innervation most probably reflects a delay in the development or maturation of the nerve elements of the CCS, similar to that noted for other parts of the central and peripheral nervous systems in SIDS.

Atrioventricular Node↗