Capnography and the Bain circuit II: Validation of a computer model.

Validation of a computer model is described. The behavior of this model is compared both with mechanical ventilation of a test lung in a laboratory setup that uses a washout method and with manual ventilation. A comparison is also made with results obtained from a volunteer breathing spontaneously through a Bain circuit and with results published in the literature. This computer model is a multisegment representation of the Bain circuit and connecting tubing. For each segment, gas pressure, gas volume flow, and partial pressure of carbon dioxide are calculated for any number of breaths wanted. As a result, the time course of these variables can be generated for any location or, conversely, the carbon dioxide distribution in the system can be calculated for any time instant. A test lung, the human lungs, the ventilator bellows, and the reservoir bag are each represented by a single segment. The shapes of pressure and flow curves and of the capnograms taken at different locations in the Bain tubing are in good agreement. The washout study permits measurement of the time delay between the first expiration and the arrival of carbon dioxide at a particular location. The carbon dioxide level in the test lung decreases during inspiration and is stable during expiration. Quantitative agreement between model and experimental transport delays and carbon dioxide levels is such that the differences can be explained by the inaccuracy of the measurement. This is concluded from a sensitivity analysis. The study of the effect of segment size shows an almost optimal agreement between model behavior and experimental results for a 36-segment model. Execution of a thorough validation is imperative before such models can be used for clinical management and decision making or for teaching.

Airway Resistance↗

Flow resistance of expiratory positive-pressure valve systems.

The flow-resistive characteristics of a variety of commercially available expiratory positive-pressure valve systems used to provide continuous positive airway pressure (CPAP) and positive end-expiratory pressure were evaluated. One flow-resistor and seven threshold-resistor expiratory pressure valve systems were set at 5, 10, 15, 20, and 25 cm H2O of expiratory pressure, and sinusoidal exhaled flows peaking at 50,100, and 200 L/min were directed through each valve at each level of expiratory pressure. The Siemens flow-resistor valve demonstrated the greatest deviation in pressure above set CPAP levels at peak flow rates of 100 and 200 L/min, which suggests high resistance to exhaled flow. The Vital Signs threshold-resistor valve demonstrated the least deviation in pressure from set CPAP levels at all rates of exhaled flow, which suggests low flow resistance. The Emerson and IMV Bird threshold-resistor systems resisted flow less than the BEAR-2 and the Puritan-Bennett MA-2 and 7200 inflatable-balloon threshold-resistor-like valve systems. These data suggest that threshold resistors may be classified as low-resistance or high-resistance types. Using only low-resistance threshold resistors for CPAP may minimize the incidence of barotrauma and other deleterious effects related to airway pressure.

Airway Resistance↗

Capnography and the Bain circuit I: A computer model.

The Mapleson D anesthesia breathing system has no valves and allows rebreathing of carbon dioxide. Its coaxial version is known as the Bain system. The interpretation of capnograms obtained during its use requires an understanding of the interrelationships of patient and system variables. Toward that end, a systematic description of mechanical ventilation with the Bain circuit was undertaken based on the physical laws of gas transport. The mathematical formulation of the model contains the relations between pressure, flow, and volume in the tube, alveolar space, and ventilator. The flows, calculated from these relations, are used to determine the CO2 concentrations in the different parts of the model. Two sets of data are used--patient and system. The patient data, used to solve the equations numerically, are lung-thorax compliance, CO2 inflow into alveolar space (CO2 production), functional residual capacity, dead space volume, airway resistance, and respiratory quotient. The ventilation system data comprise the dimensions and volumes of the Bain circuit, ventilator, connectors, and tubes; spill valve pressure; resistances to flow in the individual tube parts; ventilator settings; and fresh-gas flow rates. After incorporation of a volunteer's respiratory variables into the model, capnograms obtained from the model compared well with those obtained from the volunteer. The structure of the model is such that it permits easy introduction or changes of patient and system variables to obtain individual results or model specific circumstances. This flexibility makes it a useful tool for understanding the properties of the Bain circuit under a variety of clinical circumstances. The results may be displayed in a number of different ways.

Anesthesia, General↗

Factors influencing capnography in the Bain circuit.

The Bain circuit provides continuous fresh gas flow near the airway. The potential mixing of this fresh gas with expired gas may prevent reliable analysis of expired gas. We therefore investigated the interaction of sampling site, fresh gas flow rate, expiratory flow rate, and sampling flow rate on expiratory capnography. Sampling near the fresh gas outlet yielded inaccurate results under several of these conditions. The magnitude of the error was related to the fresh gas and expiratory flow rates. A reliable sampling region near the endotracheal tube was identified.

Anesthesiology↗