Enlargement of the photorefractive keratectomy optical zone.
PURPOSE: To evaluate the safety and efficacy of a photorefractive keratectomy (PRK) re-treatment procedure that enlarges the optical zone and treats undercorrection. SETTING: Rotterdam Eye Hospital and Medisch Centrum Alkmaar, The Netherlands. METHODS: This study evaluated 16 eyes that had PRK for myopia with the Summit excimer laser that resulted in a mean undercorrection of -2.82 diopters (D). Patients also reported impaired night vision including difficulty in driving, halos, and stray light and ghost images. These phenomena persisted after spectacle correction of residual refractive error, necessitating further treatment with a larger ablation zone. With a VISX 20/20 excimer laser, the optical zone was enlarged to 6.0 mm and undercorrection treated with a 6.0 mm ablation. RESULTS: At 13.5 months after re-treatment, mean reduction in myopia was 1.70 D, resulting in a residual undercorrection of -1.08 D. In seven eyes, final refraction was within 1.00 D of emmetropia. Only two patients continued to report night-driving problems. CONCLUSIONS: Re-treating undercorrections combined with enlarging the ablation zone resulted in a reduction in myopia from a mean of 2.82 to 1.08 D. Subjective reports of halos and stray light images were decreased in all cases.
Night vision testing in unoperated eyes.
BACKGROUND: We previously described a simple test which evaluates image degradation in post-excimer laser (PRK) patients under scotopic conditions. After refractive surgery, corneal haze, ablation zone decentration, ablation zone/pupillary diameter disparity, and under-correction each result in a characteristic pattern on the Night Vision Recording Chart. METHODS: Using the same method, further studies evaluated night vision image degradation in 118 un-operated emmetropic, myopic, hyperopic, and astigmatic eyes and in 26 contact lens wearers. RESULTS: Scotopic image degradation increases with myopic refractive error, image displacement increases with astigmatism, and contact lens wearers have more image degradation that with spectacle correction. CONCLUSION: Our Night Vision Recording Chart offers a simple, reproducible method to characterize image degradation under scotopic conditions.
Efficiency of disc ablation with lasers of various wavelengths.
In testing the CO2 lasers in CW and pulse mode, the erbium:YAG, the Nd:YAG 1318 microns and 1064 microns, the argon, the holmium:YAG, and the excimer, we found the greatest efficiency in the CO2 CW and pulse mode, and the lowest efficiency in the argon. Data with the holmium:YAG were unreliable because of the early generation laser tested. The Nd:YAG was second only to the CO2 laser, and because the latter has no waveguide, we deemed the Nd:YAG the laser of choice for PLDD.
Correction of irregular astigmatism with the excimer laser.
BACKGROUND: Correction of irregular astigmatism has not been possible using available keratorefractive technology. METHODS: The authors used a topographic map as a guide and created a custom excimer ablation program, designed to create a more regular surface. The program consisted of a combination of phototherapeutic and photorefractive ablation patterns. The amount of tissue to be removed was calculated on the basis of the diameter and steepness of the irregular areas of the corneal surface. RESULTS: A more regular surface, as evidenced by topographic analysis, reduced astigmatism, and improved uncorrected visual acuity, was produced. CONCLUSION: Using the corneal topographical map as a guide, excimer laser ablation can be used to create a more regular optical surface with improved visual function.
Corneal pachymetric topography.
PURPOSE: The authors developed a system for producing topographic pachymetric maps of the corneal epithelium and anterior scar tissue. METHOD: The system uses high-frequency ultrasound scanning enhanced by digital signal processing. Ultrasonic echo data from consecutive parallel B-scans of the cornea spaced at 250-microns intervals are digitized and stored. Using the I-scan (obtained by computing the analytic signal magnitude of the deconvolved ultrasound signal), layer thickness measurements are made with a precision of 2 microns (standard deviation) at 120-microns intervals along each scan plane. The data are stored as an array, z(x,y), mapping thickness, z, onto horizontal and vertical (x,y) spatial coordinates. Pachymetric maps are then constructed by plotting local thickness, represented by a color scale, against measurement point position. RESULTS: Examples of a normal cornea, a contact lens-wearing cornea, Reis-Bückler dystrophy, and postphotorefractive keratectomy are presented. Areas with significant subepithelial scarring and general epithelial thickening in a subject with Reis-Bückler dystrophy are mapped. Unevenness in the epithelial thickness profile of the cornea in a subject after photorefractive keratectomy is shown, relative to the fellow (untreated) cornea. CONCLUSION: This technique provides the corneal surgeon with a new tool for the topographic evaluation of the thickness of anterior corneal layers in normal and pathologic corneas with high precision. In addition, the technique is not limited to optically transparent tissue.
Transconjunctival sinusotomy using the 193-nm excimer laser.
Successful surgical management of glaucoma is limited as a consequence of undesired fibroblastic response of episcleral tissues. In 10 rabbit and three human eye bank eyes, we have performed a modified sinusotomy procedure using the 193-nm excimer laser. The technique is minimally invasive. Conjunctiva is pulled over the corneoscleral limbus, and a slit-shaped (1 x 2 mm) excimer beam ablates through conjunctiva and external sclera until penetrating the outer wall of Schlemm's canal, at which time brisk egress of fluid is noted. The conjunctiva is allowed to retract, and a conjunctival bleb is formed. A single suture is used to close the conjunctival defect. Intraocular pressure in the rabbit eye was decreased from 10.0 +/- 1.8 to 4.9 +/- 1.8 mmHg immediately after surgery (p < 0.0001). Histology revealed a partial thickness, smooth-walled ablation consistent with a sinusotomy. This procedure is minimally invasive and may be useful for management of glaucoma, particularly when a substantial component of the impediment to aqueous outflow is external to the trabecular meshwork.
High-frequency ultrasound digital signal processing for biometry of the cornea in planning phototherapeutic keratectomy.
Explore the source record for details and available documents.
Surface morphology following photorefractive keratectomy.
To examine the effects of surface dehydration on corneal surface morphology before and after photorefractive keratectomy, corneas of fresh porcine eyes were deepithelialized and then immediately fixed or treated according to one of six protocols (four eyes per protocol): dehydrated under the illumination of an operating microscope; dehydrated and then rehydrated with topically applied balanced salt solution; photorefractive keratectomy; photorefractive keratectomy followed by surface dehydration; or photorefractive keratectomy followed by dehydration and subsequent rehydration. Surface smoothness (S) was measured with an image analysis system. The surfaces of the unablated corneas were smooth (S = 0.992 +/- 0.002), and dehydration did not significantly (P = .7) influence the morphology. After ablation, dehydration resulted in apparent fragmentation of the superficial lamellae, with consequent roughening of the surface (P = .0001). Rehydration was only partially successful in reducing surface irregularity. We conclude that corneal dehydration during and following photorefractive keratectomy roughens the corneal surface and should be carefully avoided.
Ablation rates and surface ultrastructure of 193 nm excimer laser keratectomies.
PURPOSE: To determine whether photorefractive keratectomy can be performed at lower energies than are currently employed in clinical trials. METHODS: Fresh pig corneas were ablated using a clinical excimer laser to study the effects of various energy densities (100-200 mJ/cm2) and beam diameters on ablation rates and on the surface ultrastructure of the ablated cornea. RESULTS: A 20-mJ increase in energy density was associated with a 0.03 micron per pulse increase in the ablation rate. A nearly linear increase in the pseudomembrane thickness occurred with increasing energy densities (r2 = 0.83) or decreasing ablation area diameter (r2 = 0.86). CONCLUSIONS: Our findings suggest that fluences less than those currently used in clinical trials (160-180 mJ) are capable of ablating tissue while producing thinner electron-dense pseudomembranes on the corneal surface. The relationship between pseudomembrane thickness and clinical factors such as reepithelialization and postoperative haze remains to be determined. Operating at lower fluences does have the advantages of allowing larger diameter ablations, reducing possible shockwave damage, and reducing the maintenance requirements for the laser.
In situ collagen gel mold as an aid in excimer laser superficial keratectomy.
PURPOSE: The aim of this study is to evaluate the potential use of bovine type I collagen as an adjuvant to excimer laser keratectomy. METHOD: A suspension of collagen with the capability to polymerize into a gel was applied to the anterior corneal surface of freshly enucleated porcine eyes, using 35.0 diopter (D), 45.5 D, or 52.0 D contact lenses as molds. Keratometry, photokeratoscopy, slit-lamp photography, scanning electron microscopy, and light microscopy were performed on the new surfaces. Furthermore, an irregular corneal surface was created and a suspension of collagen was applied to mask protruding irregularities, therefore creating a smooth surface that was subjected to excimer laser keratectomy. Ablation rates for both collagen and cornea were measured. RESULTS: Collagen suspension placed on a cornea and molded with contact lenses created a smooth-surfaced gel that conformed to the shape of the contact lens and adhered to the anterior cornea; it was optically smooth and regular as shown by photokeratoscopy, keratometry, and scanning electron microscopy. The corneal curvature was altered in accordance with the base curvature of the contact lens used. Results of keratometry showed resolution of pre-existing astigmatism without induction of new astigmatism. The ablation rate of the gel was not measurably different than that of cornea; hence, when applied to an irregular corneal surface, a smooth surface was created after excimer laser ablation. CONCLUSION: This study supports the potential value of collagen gel as an adjuvant to excimer laser keratectomy for removal of corneal irregularities as well as for correction of myopia or hyperopia with or without astigmatism.
Pupil diameter and the principal ray.
Placement of the surgical zone is critical in refractive procedures that alter a portion of the corneal curve. An improperly centered optical zone may produce glare, decrease best corrected visual acuity, and decrease contrast sensitivity. For proper placement, the new surface should be centered around the line of sight, which is the principal ray from the object of regard that passes through the image of the patient's pupil as projected on the cornea. This point is not necessarily at the geometric center of the cornea and is found by locating the center of the pupil while the patient is maintaining fixation coaxially with the surgeon. However, the pupil does not dilate concentrically and its geometric center moves as the pupil diameter changes. We have found a shift up to 0.7 mm in the geometric center of the pupil as it dilates. Therefore, centration of an ablated or a radial keratotomy zone is most efficiently done when the diameter of the modified corneal optical zone is centered around the line of sight and is superimposed upon the entrance pupil. This will minimize extension of the edge of the large pupil beyond the ablated zone and reduce unwanted secondary optical effects from degrading vision.
Soft tissue effects of the THC:YAG laser on canine vocal cords.
Recently, a laser based on a thulium-holmium-chromium (THC) doped Yttrium-aluminum-garnet (YAG) rod has been developed that produces light of 2.15 microns wavelength and can be transmitted through a low OH- silica fiberoptic cable. This wavelength falls on one of the peaks of the energy absorption spectrum of water. Thus, the THC:YAG laser eliminates the disadvantage of a cumbersome delivery system found in the CO2 laser while still providing precise cutting and minimal tissue injury inherent in lasers emitting light absorbed by water. We evaluated the soft tissue effects of this laser on canine vocal cords. Ablative lesions were produced by the THC:YAG laser and histologically examined on postoperative days 1, 7, and 28. Results indicate that the depth of tissue penetration is easily controlled and the healing response to tissue injury is comparable to that of the CO2 laser. The THC:YAG laser should prove to be a superior laser for use in otorhinolaryngology, especially when adapted to a flexible endoscope.
Alternative lasers for endoscopic surgery: comparison of pulsed thulium-holmium-chromium:YAG with continuous-wave neodymium:YAG laser for ablation of colonic mucosa.
Precise and controllable tissue vaporization is essential for minimizing risk in removal of sessile polyps from the lumen of thin walled gastrointestinal organs such as the colon. We compared the ablative efficiency on canine colonic mucosa of the THC:YAG laser with the clinically employed cw Nd:YAG laser. Fresh canine colon was treated with a progressive dose schedule using each laser at several energy/power densities. Ablation depth was measured on fresh tissue and thermal (non-ablation or coagulative) damage examined histologically. The THC:YAG ablation rates were 13.7 +/- 0.8 and 10.2 +/- 0.4 microns/J at 55 and 85 J/cm2, respectively. The Nd:YAG laser generated 3.7 +/- 0.3, 2.8 +/- 0.1, and 3.6 +/- 0.2 microns/J at 4,460, 5,095, and 5,730 W/cm2, respectively. There was a significant (P less than 0.001) difference among the THC:YAG ablation rates and between the THC:YAG and Nd:YAG ablation rates (ANOVA). The THC:YAG laser craters had significantly less collateral thermal damage than Nd:YAG. The pulsed THC:YAG laser should have an important clinical role since its use could reduce the risk of perforation in endoscopic laser procedures such as the removal of sessile polyps.
Evidence of genotoxic damage in human cataractous lenses.
Lens epithelial fragments (tags) recovered from individuals during routine cataract extraction have been assessed for cellular changes reflective of genotoxic damage. A high percentage of tags exhibited a population of micronucleated and polyploid cells. The presence and number of micronuclei (MN) in the epithelia of cataract patients appears to be independent of age and sex. However, a large number of MN in the epithelial cells of some individuals strongly suggests a history of compromised genomic integrity. While the study was not designed to define the role of DNA damage in the development of cataracts or to monitor human populations at risk of exposure to exogenous mutagens/cataractogens, the potential of the methodology to address each is demonstrated.
Photokeratitis from 193 nm argon-fluoride laser radiation.
The threshold for photokeratitis at 193 nm was obtained for the rabbit cornea using an ArF excimer laser. Because ablation occurs at a level below that for photokeratitis, it was necessary to expose the cornea to a lengthy series of low-energy exposures. It is concluded that the 193 nm photons have such a shallow penetration depth, being limited to the outermost epithelial cells, that classical photokeratitis occurs from the fluorescence emitted at the corneal epithelial absorption site. An intact tear film may help to protect the cornea from low-level, scattered 193 nm laser radiation.
Laser radiation at various wavelengths for decompression of intervertebral disk. Experimental observations on human autopsy specimens.
The interaction of laser radiation with the nucleus pulposus from autopsy specimens of human intervertebral disks was evaluated at different wavelengths (193 nm, 488 nm & 514 nm, 1064 nm, 1318 nm, 2150 nm, 2940 nm, and 10600 nm). A significant correlation of linear least squares fit of the mass ablated as a function of incident energy was found for all lasers used except the Excimer at 193 nm. The 2940-nm Erbium:YAG laser was most efficient in terms of mass of disk ablated per joule in the limited lower range where this wavelength was observed. At higher energy levels, the CO2 laser in the pulsed mode was most efficient. However, the Nd:YAG 1064-nm and 1318-nm lasers are currently best suited for percutaneous laser disk decompression because of the availability of usable waveguides. Carbonization of tissue with the more penetrating Nd:YAG 1064-nm laser increases the efficiency of tissue ablation and makes it comparable to the Nd:YAG 1318-nm laser.
Effects of a 2.15-micron laser on human atherosclerotic xenografts in vivo.
The thulium-holmium-chromium:yttrium-aluminum-garnet (THC:YAG) laser has a tissue effect similar to that of the CO2 laser, with the advantage of transmissibility through flexible fibers. The authors used a human-rabbit xenograft model to evaluate the thrombotic and healing responses of atherosclerotic vessels subjected to laser energy. Occluded atherosclerotic human coronary artery segments were recanalized in vitro by use of the THC:YAG laser. Destruction of plaque by the laser was achieved with minimal collateral thermal damage. These vascular segments were then transplanted into the rabbit abdominal aorta. The authors observed that the luminal surface of the lased vessels was more thrombogenic than that of the nonlased control vessels. However, occlusion of the lased vessels did not occur. Repair of laser-treated tissue progressed until a mature, nonthrombogenic fibrin-platelet aggregate was adherent to the luminal wall. Overall, the lased vessels behaved in a fashion similar to the nonlased control vessels. On the basis of these results, the authors believe that the THC:YAG laser may have use in human angioplasty.