Search PubMed⌕ Search

Biomedical subjects

S L Norris

Publications and source records attributed to S L Norris.

35 records · Page 2Linked to original sources

Cardiac calcifications: difficult MRI diagnosis.

Magnetic resonance imaging (MRI) and computed tomography (CT) were performed in 40 patients with a variety of cardiovascular diseases. These imaging modalities were compared to investigate their relative value in the assessment of cardiovascular diseases. Of these 40 patients, 7 were found by CT to have detectable cardiovascular calcifications. These patients included one calcified mitral stenosis, one calcified coronary artery, one calcified type B aortic dissection, two calcified myocardial infarctions, and two patients with calcific pericarditis. In several cases, MRI was misleading because of difficulty in detecting calcifications. We present a series of cases illustrating a limitation of MRI in identifying diagnostically and clinically important cardiovascular calcifications.

Adolescent↗

An unusual scintigraphic pattern in sickle cell patients.

We reviewed the nuclear medicine files of all patients enrolled in the sickle cell disease clinic who had had scans performed within the previous 5 years. We specifically looked for patterns of tracer uptake in these scans that would correlate with the severe anemia and consequent bone marrow hyperactivity of sickle cell patients. Thirty-three patients were included (21 men and 12 women) with a mean age of 26.8 years (range 17-48 years). The appearance of each of these patients' most recent scans was examined in the areas of the distal femurs, the proximal tibias and the distal tibias; a distinct triangular shaped pattern of increased activity was identified in these areas in a majority of patients. Thirty-three patients without sickle cell disease served as age-matched controls. This pattern was seen in 65.1% (95 out of 146 images) of the sickle cell patients' delayed images and 80.4% (82 out of 102 images) of their blood pool images. In contrast, the control patients demonstrated the triangular pattern in none of their blood pool studies (0%) and only 10.9% of their delayed bone images (P less than 0.001). The mean age of sickle cell patients with this pattern is 25.6 years which was significantly lower than that of those without this pattern (mean = 37.5 years, P less than 0.05). Given the high prevalence of this unique scintigraphic pattern in a group of patients with known accelerated bone marrow function, these findings may be scintigraphic evidence of bone marrow expansion. The patient's age appears to be an important factor in visualization of this pattern.

Adult↗

Thermodilution cardiac output--an in vitro model of low flow states.

The accuracy and reproducibility of thermodilution cardiac output measurements were examined in vitro at low flows, using the Edwards cardiac output computer. For each of 18 different volumetrically measured flows between 130 and 1035 ml/min, three cardiac outputs were determined for each of four different injectate volumes (1,2,3, and 5 ml) at two different temperatures (0 degrees C and room temperature). There was a significant (p less than .001) correlation between measured flow and cardiac output for all injectate volumes at both temperatures. The slopes of the regression lines ranged between 0.97 and 1.25, and the y-intercepts were all greater than 0. Although this thermodilution technique overestimated cardiac output, it was a reproducible means of measuring cardiac output in this low-flow in vitro model.

Cardiac Output↗

Acute cardiopulmonary effects of subarachnoid hemorrhage in monkeys.

Twenty-eight cynomolgus monkeys had an autologous subarachnoid blood clot placed in the basal cisternae via craniectomy. Twenty-three monkeys survived clot placement and five animals died within 24 h. An additional eight monkeys underwent sham procedures and six acted as anesthetic controls. Cardiopulmonary indices were measured before clot placement and 30 to 60 min thereafter, to determine if certain changes had prognostic value for immediate outcome. In the 24-h survivors, heart rate and arteriovenous oxygen content difference increased significantly (p less than .05 and .01, respectively), while stroke index (SI) (p less than .01), mean pulmonary artery pressure (p less than .001), pulmonary artery wedge pressure (p less than .001), and central venous pressure (p less than .05) fell. In the 24-h nonsurvivors, cardiac index (CI) (p less than .05) and SI (p less than .01) fell to an even greater extent than in the survivors. There was a significant (p less than .05) difference between the two groups for CI and SI. There were no significant differences in the sham-operated animals. In six control monkeys, neither heart rate nor CI significantly increased throughout 5 h of anesthesia.

Animals↗

Nimodipine and chronic vasospasm in monkeys: Part 3. Cardiopulmonary effects.

A subarachnoid hemorrhage was induced in 30 cynomolgus monkeys by the placement of a 6- to 7-ml blood clot through a frontotemporal craniectomy (Day 0). The monkeys underwent a 1-week-long, randomized, blind trial comparing various doses of nimodipine to placebo, sham, and no treatment. The treatment groups were: nimodipine, 3 mg/kg every 8 hours (n = 6), 6 mg/kg every 8 hours (n = 6), and 12 mg/kg every 8 hours (n = 6); placebo (polyethylene glycol 400), 0.33 ml/kg every 8 hours (n = 6); and no treatment (n = 6). An additional sham group underwent craniectomy without clot placement (n = 6) so that 36 animals in total were operated upon. Differences in cardiopulmonary indices between Day 0 and Day 7 were compared within and between groups. No significant differences were obtained in the sham and no treatment groups. The nimodipine 6- and 12-mg/kg groups showed significant decreases in blood pressure (P less than 0.04 and P less than 0.015). Systemic vascular resistance was increased in the placebo and 3-mg/kg groups (P less than 0.02) and decreased in the 12-mg/kg group (P less than 0.015). Stroke index was increased in the 12-mg/kg group (P less than 0.05). Cardiac index and stroke index correlated positively with nimodipine dosage (r = 0.99, P less than 0.05). There were no pronounced changes in pulmonary artery wedge pressure, central venous pressure, alveolar-arterial oxygen pressure difference, arteriovenous oxygen content difference, and percentage of shunting.

Animals↗

Quantitative analysis of stress thallium-201 myocardial scintigrams: a multicenter trial.

Previously we validated a method for quantification of 201TI myocardial stress distribution and washout in which the patient's stress and washout circumferential profiles are compared with observed normal limits. The present study reports the results of a multicenter trial in which this method, utilizing normal limits from our institution, was employed to evaluate the presence, location, and extent of coronary artery disease (CAD). The normal limits utilized were generated from 49 patients having a low likelihood of CAD. The study population included 157 patients from four centers in the United States and Canada as well as a comparative prospective population from Cedars-Sinai Medical Center (CSMC) of 51 patients with CAD, 30 patients with normal coronary arteriograms, and 30 additional low-likelihood normals. The results in the combined centers regarding overall detection of CAD revealed a sensitivity of 84% and a frequency of test normality in the patients with low likelihood of CAD of 88%, compared to a sensitivity of 82% and true normalcy rate of 83% obtained in the prospective CSMC population. The sensitivity for detecting disease increased according to the extent of angiographic CAD in both the multicenter sites and the prospective CSMC group. Regarding localization of disease, similar sensitivities and specificities for detecting disease in individual coronary arteries were found in the multicenter sites and the prospective CSMC population. The results indicate that our method for quantifying 201TI stress-redistribution scintigrams utilizing standard normal limits can be applied at other institutions using a variety of scintillation cameras with similar accuracy to that currently obtained at our institution.

Adult↗

Gold-195m first-pass radionuclide ventriculography, thallium-201 single-photon emission CT, and 12-lead ECG stress testing as a combined procedure.

Graded, sequential, rest/exercise, gold-195m (Au-195m) (T1/2 = 30 seconds), first-pass ventriculography and thallium-201 (T1-201) single-photon emission computed tomography (SPECT) were performed simultaneously during a single, electrocardiograph-monitored, bicycle stress test in 24 individuals. The technical aspects and logistics involved in performing this combined radionuclide study are stressed in this preliminary report. Fourteen healthy volunteers each had a normal left ventricular ejection fraction and wall-motion response, along with normal Tl-201 perfusion and washout, as determined by both visual and quantitative analysis of the tomographic sections. Each of ten patients with coronary artery disease had at least one abnormality of these parameters. We suggest that it is technically feasible to evaluate both cardiac function and myocardial perfusion simultaneously by combining Au-195m ventriculography and T1-201 SPECT imaging into a single, noninvasive, diagnostic package.

Adult↗

Sensitivity and specificity of nuclear phase analysis versus ejection fraction in coronary artery disease.

Phase standard deviation (SD) and skew characteristics of the first Fourier harmonic of equilibrium radionuclide volume curves were examined and compared during rest and during supine bicycle exercise with ejection fraction (EF) changes and the development of ischemia in 17 control subjects and in 2 groups of patients (n = 57) with coronary artery disease (CAD). Group I comprised 37 patients with CAD; IA was a subgroup of 20 patients with previous myocardial infarction (MI) and IB a subgroup of 17 patients with CAD without MI (all with coronary stenosis greater than 75% diameter narrowing). Group II comprised 20 patients with CAD who had undergone coronary bypass surgery. In the Group I subjects, phase SD was the most sensitive indicator of CAD at rest (Group I, 56%; Group IA, 70%, and Group IB, 29%), and the EF was the most sensitive indicator at submaximal (Group I, 78%; Group IA, 86%, and Group IB, 64%) and maximal exercise (Group I, 70%; Group IA, 93%, and Group IB, 53%). When phase SD and skewness were combined with EF changes, little increase in sensitivity occurred in Group I (rest 61%, submaximal exercise 88% and maximal exercise 76%). The results from Group II subgroups were qualitatively similar to those observed with Group I subgroups. These data reveal a marginally improved sensitivity for detection of CAD during supine bicycle radionuclide ventriculography when phase measurements were added to changes in global EF values.

Adult↗

Comparison of digital intravenous ventriculography with direct left ventriculography for quantitation of left ventricular volumes and ejection fractions.

Digital images of the left ventricle obtained at 30 frames/second from continuous fluoroscopy after intravenous injection of contrast medium (digital intravenous ventriculography) were used to estimate left ventricular (LV) volumes and ejection fraction with use of several techniques for identifying the ventriculographic silhouette. The digital technique was compared with direct contrast left ventriculography in 26 patients undergoing diagnostic cardiac catheterization. End-diastolic and end-systolic volumes calculated from digital intravenous and direct left ventriculograms were obtained with use of a standard area-length formula. Both end-diastolic volume (EDV) (r = 0.88, y = 1.06x - 17.1 ml) and end-systolic volume (ESV) (r = 0.89, y = 0.96x + 0.43 ml) determined from digital intravenous ventriculography (mask mode images) correlated closely with those obtained by direct left ventriculography. Combining the EDV and ESV to define the relation between the 2 techniques yielded an even closer correlation (r = 0.96). There was also good correlation between the 2 techniques for measurement of ejection fraction (r = 0.81, standard error of the estimate 6.7%). Measurements from direct left ventriculography were frequently invalidated by ventricular arrhythmias during the time of opacification of the left ventricle; this was rarely the case for digital intravenous ventriculography. It is concluded that area-length estimates of LV volumes and ejection fraction can be accurately obtained from digital processing of fluoroscopic LV images after intravenous injection of contrast medium.

Arrhythmias, Cardiac↗

Radionuclide analysis of peak filling rate, filling fraction, and time to peak filling rate. Response to supine bicycle exercise in normal subjects and patients with coronary disease.

Using gated equilibrium radionuclide angiography, variables of diastolic filling were analyzed at rest and during supine bicycle exercise in normal subjects (Group 1, n = 18), coronary patients with normal resting ejection fractions (Group 2, n = 26), and coronary patients with reduced resting ejection fractions (Group 3, n = 8). Indexes analyzed were peak filling rate and filling fraction during the first third of diastole. At rest, the peak filling rate was significantly lower in coronary patients than in normal subjects (3.18 +/- 0.82 end-diastolic volume [EDV]/s in Group 1 versus 2.41 +/- 0.66 EDV/s in Group 2, p less than 0.005; and 1.34 +/- 0.26 EDV/s in Group 3, p less than 0.001 versus Group 1). These differences persisted at peak exercise. Coronary patients also had significantly lower filling fractions at rest and during exercise than did normal control subjects. The time from end-systole to peak filling rate was longer at rest in patients in Group 2 (203 +/- 52 ms) than in subjects in Group 1 (172 +/- 50 ms, p less than 0.025). This remained true when the time to peak filling was normalized by the R-R interval. Although the exercise time to peak filling was longer in coronary patients in both Groups 2 and 3 than in Group 1, these differences were not apparent when the interval was normalized by the R-R interval. Thus, abnormalities in peak filling rate and filling fraction exist in patients with coronary disease both at rest and during exercise, but large overlaps exist between normal and coronary patients. Caution is advised in comparing the timing of events during diastole because apparent group differences may be related in part to rest or exercise heart rate.

Adult↗

Cardiac imaging with digital subtraction angiography.

Central cardiovascular anatomy and function have been evaluated with intravenous digital subtraction angiography (DSA). The subtraction techniques used for studying the left ventricle (LV) were mask mode, time interval difference and functional subtraction. Aside from contrast enhancement, a major use of digital fluoroscopy for cardiac applications has been computer-assisted quantitative analysis of LV dimensions and function. Left ventricular volumes and wall thickness determined from DSA studies have correlated closely with direct left ventriculograms and sonocardiometry measurements in patients and animals, respectively. Measurements of segmental LV contraction with DSA correlated closely with direct left ventriculography in normal patients and patients with coronary artery disease. The sensitivity of intravenous DSA for detecting significant coronary artery disease was increased by performing DSA immediately after increasing the myocardial oxygen demands by atrial pacing. The advantages and disadvantages of DSA in relation to other semi-or non-invasive imaging modalities are discussed.

Angiocardiography↗

Quantitative phase analysis of exercise radionuclide left ventriculography in normals and patients with coronary artery disease.

Using multigated radionuclide ventriculography (RNV), the left ventricular (LV) phase histogram (PH) was used to quantitate LV synchrony at rest and at submaximal and maximal supine exercise in 10 normal and 10 coronary (CAD) patients. Each LV PH was obtained by masking the phase image with an LV region, generated semiautomatically and modified if necessary to minimize ambiguity of LV delineation. The shape and spread of each histogram was characterized by its standard deviation (SD) and skewness (SK). Normals had a tight resting PH with slight negative skewness (SD = 9.06 +/- 0.22 (mean +/- SEM; SK = -0.53 +/- 0.05). CAD patients had a wider resting PH with a larger SD and a significantly more positive skewness reflecting greater contractile asynchrony (SD = 16.53 +/- 2.26; SK = 0.35 +/- 0.22). With exercise the PH distribution for the normals remained tight (SD = 8.1 +/- 0.24) while SK changed little (SK = -0.29 +/- 0.04). In contradistinction, with exercise CAD patients markedly increased the spread of their LV PH (SD = 27.42 +/- 3.77) and increased the number of late pixels (SK = 0.75 +/- 0.15). It is concluded that quantitative PH analysis is a useful adjunct for the analysis of regional asynergy during resting or exercise radionuclide left ventriculography.

Coronary Disease↗

Quantitative assessment of segmental wall motion abnormalities at rest and after atrial pacing using digital intravenous ventriculography.

Digital intravenous ventriculography lends itself readily to quantitative assessment of ventricular wall motion with computer algorithms. Forty-five patients referred for cardiac catheterization were studied by digital intravenous ventriculography (mask mode) and direct ventriculography in the 30 degrees right anterior oblique position. Quantitative wall motion was analyzed by a radial shortening method applied to both studies. Lower limits of normal radial shortening were determined for each technique and used to determine the presence or absence of wall motion disorders. The inter- and intraobserver variability of radial shortening measurements was +/- 5.3 and +/- 8.8%, respectively, with maximal discrepancies of -6 and +7% fractional shortening units. The overall agreement between the two techniques in wall motion assessment was 87% (274 of 315 radii). A subset of patients also underwent atrial pacing, and a second digital intravenous ventriculogram was obtained (5 normal subjects and 15 patients with coronary artery disease). Although analysis of wall motion at rest showed a poor sensitivity for detection of significant coronary stenoses, nine of nine patients with coronary artery disease and normal wall motion at rest showed a quantitative decrease in radial wall motion after atrial pacing. Thus, digital intravenous ventriculograms can be used to provide quantitative wall motion analyses that show a high degree of agreement with those of standard, direct left ventriculography. Atrial pacing can be used to increase the sensitivity of wall motion analysis for the detection of significant coronary disease.

Aged↗

Quantitation of left ventricular dimensions and function by digital video subtraction angiography.

Digital video subtraction angiography (DVSA) after central intravenous administration of contrast media was used in experimental animals and in patients with suspected coronary artery disease to quantitate left ventricular dimensions and regional and global contractile function. In animals, measurements of left ventricular (LV) volumes, wall thickness, ejection fraction, segmental contraction, and cardiac output correlated closely with sonocardiometry or thermodilution measurements. In patients, volumes and ejection fractions calculated from mask mode digital images correlated closely with direct left ventriculography. Global and segmental contractile function was displayed in patients by ejection shell images, stroke volume images, and time interval difference images. Central cardiovascular function was also quantitated by measurement of pulmonary transit time and calculation of pulmonary blood volume from digital fluoroscopic images. DVSA was shown to be useful and accurate in the quantitation of central cardiovascular physiology.

Angiocardiography↗

The motion artifact suppression technique (MAST) in magnetic resonance imaging: clinical results.

The Motion Artifact Suppression Technique (MAST) is a method which uses a series of gradient echos that are computed to cancel velocity, acceleration and pulsatility components of involuntary motion in MR imaging. A total of 916 patient studies were performed over a nine month period using MAST sequences with a TE 40, 60, 80, 100, 120, and 26/112. There was considerable improvement in long TR, long TE images. Cerebrospinal fluid flow artifacts were reduced. Body and spine images had reduced flow and respiratory artifacts. Spin rephasing in blood vessels caused increase intraluminal signal. This might be useful for cardiovascular imaging.

Blood Circulation↗

A comparison of the effects of intravenous and direct left ventricular contrast injections on left ventricular function.

Digital intravenous ventriculography (DIV) has become increasingly recognized as a useful and reliable approach for evaluating left ventricular (LV) performance. While it might be assumed that the hemodynamic changes caused by intravenous injection of contrast media are less than those caused by direct LV injection, these responses have not actually been compared. Accordingly, the hemodynamic effects of IV and direct LV contrast injections were compared in eight anesthetized dogs instrumented with two pairs of ultrasonic dimension crystals, one to measure LV endocardial segment length and one to measure LV internal dimension, and a LV high-fidelity pressure catheter. The alterations in LV dimension and pressure were similar using both injection techniques, though they were less marked with IV injection. Both routes of injection caused a significant decline in LV pressure (P less than 0.05) which was greatest at 30 seconds after injection, and a significant (P less than 0.05) increase in end-diastolic dimension (which was greatest between 10-30 seconds) and extent of change in LV diameter (P less than 0.01). The afterload reducing effects of the contrast media increased the rate of LV segment length shortening slightly after LV injection but not with IV injection. These data demonstrate no important differences in the hemodynamic response to IV and LV injection of contrast media. The induced hemodynamic changes after IV administration were relatively small in magnitude and transient in duration and probably not sufficient to obviate quantitative analysis of LV dimensions and function by digital intravenous angiography.

Animals↗

Method for assessing cardiac function using magnetic resonance imaging.

The authors sought to define a method to use magnetic resonance (MR) to assess cardiac function by obtaining short-axis images of the left ventricle (LV) in humans. Sagittal and axial scout1H MR images were used in the protocol. The long axis of the LV was defined in both planes using the mitral valve and left ventricular apex as references. Based on this double angulation, the acquisition planes were created for a series of parallel short-axis images extending from the base to the apex of the left ventricular cavity. Cardiac images acquired with a fast-field echo technique, six slices with 16-20 phases per RR interval, were analyzed, representing the initial 75-80% of the cardiac cycle. For each slice, the endocardial border of the left ventricular chamber was manually traced. Using Simpson's rule, the total LV volume at a given phase was determined, considering the traced area, thickness, and position in three-dimensional space of each of the six constituent slices. The calculated volumes were plotted against time, and the stroke volume, ejection fraction, and cardiac output were determined. These parameters are clinically significant indices of cardiac function. Accurate and useful estimates of LV function can be obtained using MRI according to this protocol.

Cardiac Output↗