Search PubMed⌕ Search

Biomedical subjects

S Kunze

Publications and source records attributed to S Kunze.

At least 55 records · Page 3Linked to original sources

[Intraoperative magnetic resonance tomography for control of extent of neurosurgical operations].

PURPOSE: The main aim of our study was to find out whether the combined use of neuronavigation and intraoperative MRI can increase the rate of "complete tumor removal". The second aim was to characterize the different forms of surgically induced enhancement in order to differentiate them from residual tumor. MATERIALS AND METHODS: Surgery was performed in 18 patients with high-grade glioma. Using a neuronavigation device, the surgeons operated up to the point where they would otherwise have terminated surgery. Intraoperative MRI was then performed to determine whether residual enhancing had been left behind and to update the neuronavigation device. If necessary, feasible surgery was continued. On days 1-3 after surgery early postoperative MRI (1.5 T) was performed. The proportion of patients in whom the enhancing tumor was completely removed was compared with a series of 60 patients with glioblastoma multiforme, who had been operated on using neither neuronavigation nor intraoperative MRI. We also looked for and characterized different types of surgically induced enhancement. RESULTS: Intraoperative MRI definitely showed residual tumor in 6 of the 18 patients and resulted in ambiguous findings in 3 patients. In 7 patients surgery was continued. Early postoperative MRI showed residual tumor in 3 patients and resulted in uncertain findings in 2 patients. The rate of patients in whom complete removal of enhancing tumor could be achieved was 50% at the time of the intraoperative MR examination and 72% at the time of the early postoperative MR control. The difference in proportion of patients with "complete tumor removal" between the groups who had been operated on using neuronavigation (NN) and intraoperative MRI (ioMRI) and those who had been operated on using only modern neurosurgical techniques except NN and ioMRI was statistically highly significant (Fisher exact test; P = 0.008). Four different types of surgically induced contrast enhancement were observed. These phenomena carry different confounding potentials with residual tumor. CONCLUSION: Our preliminary experience with intraoperative MRI in patients with enhancing intraaxial tumors is encouraging. Combined use of neuronavigation and intraoperative MRI was able to increase the proportion of patients in whom complete removal of the enhancing parts of the tumor was achieved. Surgically induced enhancement requires careful analysis of the intraoperative MRI in order not to confuse it with residual tumor.

Astrocytoma↗

Modified Headholder and operating table for intra-operative MRI in neurosurgery.

In order to facilitate intra-operative use of magnetic resonance imaging (MRI) in neurosurgery an MRI-compatible headholder was developed and adapted to a modified MR-couch simultaneously serving as tabletop for the operating table. To allow shock-free transport into the scanner the wheels of the operating table were replaced by an air cushion mechanism. In 75 procedures the system proved to be reliable and safe. Image quality was not impaired by the fixation device. With growing routine the transfer became straightforward, requiring approximately 10 min. Intra-operative MRI is thus made possible with minimal changes to the standard surgical environment. Its benefit however, still remains to be critically investigated.

Equipment Design↗

Neuronavigation--first experiences with three different commercially available systems.

Growing interest in neuronavigation also referred to as frameless stereotaxy has led to the development of various navigational devices employing different localization methods. In 152 procedures the authors have used neuronavigation. Cases included 89 intracranial- and 26 skull base tumours, 9 biopsies, 21 vascular and 7 functional procedures on 144 patients since July 1993. In 75 cases the lesions were located in eloquent areas. In 82% (124) MRI, 13% (18) CT and 5% (8) both imaging methods were employed. Three neuronavigational devices with different localization methods were used for the procedures. The Viewing Wand (VW, ISG, Canada), a multijointed arm was used in 101 procedures. In 15 cases the SPOCS (Aesculap, Germany) consisting of cameras detecting infrared light from LED's mounted on instruments and in 51 cases the microscope-integrated MKM (ZEISS, Germany) was investigated, 15 times two systems were used simultaneously. Mean time necessary for preoperative registration was 23 +/- 13 min (VW), 21 +/- 16 min (SPOCS) and 27 +/- 22 min (MKM) respectively. The mean accuracy of registration measured as RMS was 2.9 +/- 1.2 mm (VW), 3.3 +/- 0.9 mm (SPOCS) and 3.1 +/- 1.0 (MKM) respectively. Regarding intraoperative handling the VW was found to be a robust but sometimes bulky and hindering device whereas the SPOCS was more flexible but with the need of unobstructed visibility between cameras and pointers. The MKM without these restrictions required training to get used to handling.

Adolescent↗

Hemicraniectomy with dural augmentation in medically uncontrollable hemispheric infarction.

Surgical decompression to alleviate raised intracranial pressure has been reported repeatedly in the past decades in small series of patients. Only recently have there been indications from larger trials that surgical decompression may be beneficial in treating space-occupying hemispheric infarction. However, surgical requirements for the procedure to be effective have not yet been defined. Based on theoretical criteria, the authors operated on 43 patients with medically uncontrollable hemispheric infarctions. The craniectomies were planned to be as large as possible and performed in combination with a subtemporal decompression. Postoperative computerized tomography scans were evaluated for these criteria. The mean survival rate for the group of 43 patients was 72.1% and no surviving patient ended up in a vegetative state. The mean area of craniectomy was found to be 84.3 +/- 16.5 cm2 and the mean distance of the inferior craniectomy margin to the middle fossa was 1.8 +/- 1.3 cm. Comparison of survivors and nonsurvivors failed to show a significant difference in the size of craniectomy or the distance to the floor of the middle fossa. Compared with the reported 80% fatality rate for medically treated stroke patients, in this subgroup the outcome (72.1% survival rate) is remarkably good. The authors conclude that decompressive craniectomy is an effective treatment, able to reduce mortality, and to improve neurological outcome in patients with space-occupying cerebral infarction if the size of craniectomy is large enough. Nevertheless, there is a need for further investigation to identify patients who will benefit from surgery and predictors to optimize the timing of surgical intervention.

Journal Article↗

Image guided excision of a ruptured feeding artery "pedicle aneurysm" associated with an arteriovenous malformation in a child: case report.

Excision of a ruptured aneurysm located at a lenticulostriate feeding artery associated with an arteriovenous malformation was performed using image guided neuronavigation in an 8-year-old child. The management of this lesion, which is rare in childhood, demonstrates the potential of combining frameless stereotaxy for precise target approach with conventional open microneurosurgery to minimize morbidity. Because of the unavoidable shifting of the brain that occurs during surgery, a catheter pointing towards the dome of the aneurysm was placed using image guidance prior to insertion of spatulae.

Aneurysm, Ruptured↗

Molecular genetics of craniosynostotic syndromes.

This article reviews recent molecular genetic findings in autosomal dominant craniosynostotic syndromes. A mutation in the homeotic gene MSX2 was the first genetic defect identified in an autosomal dominant primary craniosynostosis, i.e. in craniosynostosis type 2 (Boston type). In the more common syndromes of Crouzon, Pfeiffer, Jackson-Weiss, and Apert, mutations were found in the gene coding for fibroblast growth factor receptor (FGFR) 2. Less frequently, mutations are observed in FGFR1 and FGFR3 in some cases of Crouzon and Pfeiffer syndrome. The mutations identified in FGFR2 are located in exons 5 and 7 of the gene that code for immunoglobulin (Ig)-like chain III and the region linking Ig II and Ig III of the receptor. These domains of the receptor are important for ligand binding. Apart from Apert syndrome, identical mutations are found in the clinically distinct syndromes of Crouzon, Pfeiffer, and Jackson-Weiss. Furthermore, the same gene defect can result in a highly variable phenotype even within one family. Therefore, the clinically distinct craniosynostotic syndromes are extremes of a spectrum of craniofacial abnormalities and not nosologic entities. In Saethre-Chotzen syndrome, the gene coding for transcription factor TWIST is mutated. The disease genes identified in craniosynostotic syndromes to date either regulate transcription or are required for signal transduction and play a central role in the development of the calvarial sutures.

Animals↗

Intraoperative diagnostic and interventional magnetic resonance imaging in neurosurgery.

OBJECTIVE: The benefits of intraoperative magnetic resonance (MR) imaging for diagnostic and therapeutic measures are as follows: 1) intraoperative update of data sets for navigational systems, 2) intraoperative resection control of brain tumors, and 3) frameless and frame-based on-line MR-guided interventions. The concept of an intraoperative MR scanner in the sterile environment of operating theater is presented, and its advantages, disadvantages, and limitations are discussed. METHODS: A 0.2-tesla magnet (Magnetom Open; Siemens AG, Erlangen, Germany) inside a radiofrequency cabin with a radiofrequency-shielded sliding door was installed adjacent to one of the operating theaters. A specially designed patient transport system carried the patient in a fixed position on an air cushion to the scanner and back to the surgeon. RESULTS: In a series of 27 patients, intraoperative resection control was performed in 13 cases, with intraoperative reregistration in 4 cases. Biopsies, cyst aspirations, and catheter placements (mainly frameless) were performed under direct MR visualization with fast image sequences. The MR-compatible equipment and the patient transport system are safe and reliable. CONCLUSION: Intraoperative MR imaging is a safe and successful tool for surgical resection control and is clearly superior to computed tomography. Intraoperative acquisition of data sets eliminates the problem of brain shift in conventional navigational systems. Finally, on-line MR-guided interventional procedures can be performed easily with this setting. As with all MR systems, individual testing with phantoms, application of correction programs, and determination of the optimal amount of contrast media are absolute prerequisites to guarantee patient safety and surgical success.

Adult↗

Image-guided neurosurgery with intraoperative MRI: update of frameless stereotaxy and radicality control.

Intraoperative shifts and resulting inaccuracies have been a concern in frame based and frameless stereotactically guided interventions, particularly in open microsurgical procedures. Trying to solve this problem, we developed a method to perform intraoperative MRI (0.2 tesla, Magnetom Open) and use intraoperatively acquired data sets to update neuronavigation. In 21 patients, intraoperative images could be used to reference navigation (mean accuracy of 0.83 +/- 0.31 mm). The operation was continued in 10 cases to resect detected tumor remnants using navigation, leaving 4 patients (19%) with residual tumor postoperatively. We showed that update of frameless stereotaxy to compensate for brain shift is feasible and might increase the number of cases where radiologically complete resection can be achieved.

Equipment Design↗

Intraoperative magnetic resonance imaging to update interactive navigation in neurosurgery: method and preliminary experience.

We report on the first successful intraoperative update of interactive image guidance based on an intraoperatively acquired magnetic resonance imaging (MRI) date set. To date, intraoperative imaging methods such as ultrasound, computerized tomography (CT), or MRI have not been successfully used to update interactive navigation. We developed a method of imaging patients intraoperatively with the surgical field exposed in an MRI scanner (Magnetom Open; Siemens Corp., Erlangen, Germany). In 12 patients, intraoperatively acquired 3D data sets were used for successful recalibration of neuronavigation, accounting for any anatomical changes caused by surgical manipulations. The MKM Microscope (Zeiss Corp., Oberkochen, Germany) was used as navigational system. With implantable fiducial markers, an accuracy of 0.84 +/- 0.4 mm for intraoperative reregistration was achieved. Residual tumor detected on MRI was consequently resected using navigation with the intraoperative data. No adverse effects were observed from intraoperative imaging or the use of navigation with intraoperative images, demonstrating the feasibility of recalibrating navigation with intraoperative MRI.

Adult↗

Chronic precentral stimulation in trigeminal neuropathic pain.

The results of Deep Brain Stimulation in deafferentation pain syndromes, in particular in thalamic pain, indicate that excellent long-term pain relief can hardly ever be achieved. We report 7 cases using Motor-Cortex-Stimulation for treating severe trigeminal neuropathic pain syndromes, i.e., dysaesthesia, anaesthesia dolorosa and postherpetic neuralgia. The first implantation of the stimulation device for precentral cerebral stimulation was performed in June 1993, the last in September 1995. In all but one case the impulse-generator was implanted after a successful period of test stimulation. Successful means a pain reduction of more than 50% as assessed with a Visual Analogue Scale. Excluding one case, in whom a prolonged focal seizure resulting in a postictal speech arrest occurred during test stimulation, there have been no operative complications and the postoperative course was uneventful. In all the other patients the pain inhibition appeared below the threshold for producing motor effects. Initially these patients reported a good to excellent pain relief. In three of 6 patients a good to excellent pain control was maintained for a follow-up period of 5 months to 2 years. In the remaining three patients the positive effect decreased over several months.

Adult↗

Knowledge retrieval as one type of knowledge-based decision support in medicine: results of an evaluation study.

We report on a prospective, prolective observational study, supplying information on how physicians and other health care professionals retrieve medical knowledge on-line within the Heidelberg University Hospital information system. Within this hospital information system, on-line access to medical knowledge has been realised by installing a medical knowledge server in the range of about 24 GB and by providing access to it by health care professional workstations in wards, physicians' rooms, etc. During the study, we observed about 96 accesses per working day. The main group of health care professionals retrieving medical knowledge were physicians and medical students. Primary reasons for its utilisation were identified as support for the users' scientific work (50%), own clinical cases (19%), general medical problems (14%) and current clinical problems (13%). Health care professionals had accesses to medical knowledge bases such as MEDLINE (79%), drug bases ('Rote Liste', 6%), and to electronic text books and knowledge base systems as well. Sixty-five percent of accesses to medical knowledge were judged to be successful. In our opinion, medical knowledge retrieval can serve as a first step towards knowledge processing in medicine. We point out the consequences for the management of hospital information systems in order to provide the prerequisites for such a type of knowledge retrieval.

Computer Systems↗

Intraoperative computer-assisted neuronavigation in functional neurosurgery.

The clinical experience with a frameless computer-assisted neuronavigational system (ISG. Canada) used in functional neurosurgery is described. The advantage of image-guided surgery is stressed for functional procedures of the cortex with delineation of the gyral pattern, e.g. motor cortex stimulation and procedures at the base of the skull with triplanar and three-dimensional reconstruction of the bony landmarks. A general use of the device for aiming at subcortical targets cannot be recommended. Limitations are the accuracy (< or = 2.2 mm) and software deficiencies and the lack of a reliable fixation of the position sensing arm (wand).

Cerebral Cortex↗

Coil placement after clipping: endovascular treatment of incompletely clipped cerebral aneurysms. Report of two cases.

In up to 4% of patients whose aneurysms are microsurgically clipped, there is an expected or unexpected aneurysm residuum. The authors describe two patients in whom surgical clipping did not result in complete obliteration of the aneurysm sac and in whom a second operation was not believed to be the solution to the problem. In both patients complete occlusion of the aneurysm residuum was achieved via an endovascular approach. Using the Guglielmi detachable coil system, it was possible to place two platinum coils selectively into the aneurysms. The endovascular approach may be a good treatment option for all patients in whom surgical clipping does not result in complete obliteration of the aneurysm sac and reoperation is contraindicated or unacceptable to the patient.

Adult↗

Overdrainage and shunt technology. A critical comparison of programmable, hydrostatic and variable-resistance valves and flow-reducing devices.

When vertical body position is simulated, conventional differential pressure valves show an absolutely unphysiological flow, which is 2-170 times the normal liquor production rate. Although this is compensated in part by the resistance of the silicon tubes, which may produce up to 94% of the resistance of the complete shunt system, a negative intracranial pressure (ICP) of up to 30-44 cmH2O is an unavoidable consequence, which can be followed by subdural hematomas, slit ventricles, and other well-known complications. Modern shunt technology offers programmable, hydrostatic, and "flow-controlled" valves and anti-siphon devices; we have tested 13 different designs from 7 manufacturers (56 specimens), using the "Heidelberg Valve Test Inventory" with 16 subtests. "Programmable" valves reduce, but cannot exclude, unphysiological flow rates: even in the highest position and in combination with a standard catheter typical programmable Medos-Hakim valves allow a flow of 93-232 ml/h, Sophy SU-8-valves 86-168 ml/h with 30 cmH2O. The effect of hydrostatic valves (Hakim-Lumbar, Chhabra) can be inactivated by movements of daily life. The weight of the metal balls in most valves was too low for adequate flow reduction. Antisiphon devices are highly dependent on external, i.e. subcutaneous, pressure which has unpredictable influences on shunt function, and clinically is sometimes followed by shunt insufficiency. Two new Orbis-Sigma valves showed relatively physiological flow rates even when the vertical position (30 cmH2O) was simulated. One showed an insufficient flow (5.7 ml/h), and one was primarily obstructed. These have by far the smallest outlet of all valves. Additionally, the ruby pin tends to stick. Therefore, a high susceptibility to obliterations and blockade is unavoidable. Encouraging results obtained in pediatric patients contrast with disappointing experiences in some German and Swedish hospitals, which suggests that our laboratory findings are confirmed by clinical results. The concept of strict flow limitation seems to be inadaequate for adult patients, who need a relatively high flow during (nocturnal) ICP crises. The problem of shunt overdrainage remains unsolved.

Adult↗

Combined microneurosurgical and endovascular "trapping-evacuation" technique for clipping proximal paraclinoidal aneurysms.

A method is described in which a combined endovascular and microneurosurgical approach is used for clipping aneurysms of the proximal paraclinoidal segment of the internal carotid artery. By temporary occlusion of the cervical carotid artery and continuously retrograde sucking of blood from the distal vessel via a double lumen ballon catheter, clip application to large and critically located aneurysms is facilitated applying decompression to the trapped arterial segment under intraoperative somatosensory-evoked potential (SEP) monitoring.

Journal Article↗

[Description of selected aspects of health services for elderly citizens by social services in Saxony].

The following analysis describes selected aspects of Saxonian social and medical care for people in need of help and elderly, via "community social service units". Almost 16% of people are older than 65 years in Saxonia, whereas the number of women is twice the number of men. To secure the social and medical care "community social service units" were founded partly from former municipal nursing stations of the former GDR and partly from newly founded institutions. Basic and medical care is an essential part of the supply in "community social service units". To approximate an all-embracing social and medical care, so-called "other tasks" complete the general service from a qualitative point of view.

Aged↗

Mood changes after surgery for tumors of the cerebral cortex.

OBJECTIVE: To identify cortical lesion sites associated with particular mood states. DESIGN: A prospective study of patients with tumors affecting the cerebral cortex. The patients were examined neuropsychologically 1 to 5 days preoperatively and 2 to 10 days, several months, and several years postoperatively. Only data from the preoperative and the first postoperative examination were considered in this report. SETTING: Neurosurgical department of the University of Heidelberg (Germany). PATIENTS AND SUBJECTS: A consecutive sample of 141 patients with brain tumors (84 female and 57 male) with cortical lesions caused by microsurgical tumor resection; 29 clinical control patients (having undergone surgery for slipped disks); and 18 normal control subjects. MAIN OUTCOME MEASURE: Preoperative and postoperative mood state as measured with an adjective checklist. RESULTS: (1) Patients with lesions of the ventral frontal cortex or lesions of the temporoparietal cortex reported postoperatively significantly (P < .01) worse mood states (anxiety/depression, irritability/anger, fatigue) than did patients in the other lesion and control groups. (2) A more detailed lesion analysis revealed that lesions of heteromodal frontal or parietal association cortexes, combined with paralimbic lesions, were responsible for the negative mood states. Lesions of the sensorimotor cortexes ameliorated the negative effects of heteromodal and paralimbic lesions. (3) Lesion laterality did not influence the mood states. CONCLUSIONS: Heteromodal cortexes may be especially concerned with emotionally relevant operations. A loss of these functions deprives limbic structures of one of their main sources of input and is therefore likely also to produce changes in feelings, that is, emotional states.

Adult↗