Search PubMedSearch

Biomedical subjects

S Koehler

Publications and source records attributed to S Koehler.

7 recordsLinked to original sources

Experience with a mixed semantic/syntactic parser.

The value of the computerized medical record is derived in part from the availability of medical information in a coded form accessible to manipulation by processes designed for automated decision support, medical research, and computer assistance in the management of health care delivery. To meet these needs medical reports captured and stored as natural language documents must be encoded. Below we discuss an ongoing formative process aimed at developing a natural language understanding system for chest x-ray reports. Comparative data showing the progress of this process is presented.

Hospital Information Systems

Three-point transformation for integration of multiple coordinate systems: applications to tumor, functional, and fractionated radiosurgery stereotactic planning.

The accuracy of an optimized three-point transformation method and its usefulness for integrating multiple independent coordinate systems has been described. Such integration can be implemented to accomplish complex stereotactic procedures which may require the use of multiple image data sets and combinations of frame-based and frameless stereotactic systems. This report details the application of an optimized transformation for intracranial lesion biopsy and/or resection, radiofrequency pallidotomy for treatment of Parkinson's disease, and fractionated stereotactic radiosurgery in a total of 68 patients. For approach to intracranial lesions, a noninvasive definition of image coordinate systems with multiple radiodense scalp markers was cross-registered with a standard stereotactic guidance system. This method allowed for elective acquisition of stereotactic image sets without requiring head frame fixation until the time of the operative procedure. In planning pallidotomy procedures, spatial cross-registration of CT and MR image coordinates were performed to target the posteroventral pallidum. CT coordinates were defined by the standard picket fence algorithm while MR images were referenced with multiple scalp markers. The addition of MR data sets improved anatomic resolution in the regions of the basal ganglia and commissures. Fractionated radiosurgery was accomplished by cross-registration of CT, MR, and plain radiographs using BRW localizers coupled with multiple scalp markers. A daily check of target positioning was performed with the BRW angiograph localizer. The average calculated error was 2.83 mm with a standard deviation of 1.66 mm which remained within the average scan slice thickness of 3.63 mm. In all cases surgical targets were reached without complication.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult

Preliminary experience using an optimized three-point transformation algorithm for spatial registration of coordinate systems: a method of noninvasive localization using frame-based stereotactic guidance systems.

This study describes the use of an optimized three-point transformation algorithm to spatially cross-register a volumetric computerized tomographic scan or magnetic resonance image data set with the coordinate system of a stereotactic frame. This algorithm was tested for accuracy using a scanned phantom in which calculated targets, using the Brown-Roberts-Wells (BRW) frame picket-fence algorithm as a standard, could be compared to physical targets measured using a BRW arc and phantom. These target values were then compared to target values calculated with the optimized three-point algorithm. This method was used for target localization in 21 patients. Following this noninvasive localization method, the standard BRW stereotactic system was used for guidance. The application accuracy of this frameless localization technique was within the limits of the scan slice thickness in 16 of 21 cases, with an average error of 2.11 mm in an average scan slice thickness of 3.1 mm. Intracranial targets were successfully reached in all cases without morbidity or mortality. The algorithm can be customized to cross-register image data sets with the coordinate systems of a wide variety of stereotactic guidance systems. The method increases the convenience and flexibility of frame-based stereotactic guidance by providing a means of noninvasive localization that can be accomplished electively at a separate time from the guidance part of a stereotactic operative procedure.

Aged

A natural language understanding system combining syntactic and semantic techniques.

A large proportion of the medical record currently available in computerized medical information systems is in the form of free text reports. While the accessibility of this source of data is improved through inclusion in the computerized record, it remains unavailable for automated decision support, medical research, and management of medical delivery systems. Natural language understanding systems (NLUS) designed to encode free text reports represent one approach to making this information available for these uses. Below we describe an experimental NLUS designed to parse the reports of chest radiographs and store the clinical data extracted in a medical data base.

Bayes Theorem

Repeated dose administration of desmopressin acetate in uncomplicated cardiac surgery: a prospective, blinded, randomized study.

The effects of single or repeated doses of desmopressin on blood loss were examined in uncomplicated cardiac surgery, while assessing the potential for thrombogenic side effects. Seventy patients undergoing elective coronary artery bypass grafting (CABG) were studied. Patients were randomized into three blinded groups: Group I received DDAVP (0.3 micrograms/kg), IV, after cardiopulmonary bypass (CPB) and 12 hours later in the Intensive Care Unit (ICU); Group II, DDAVP (0.3 micrograms/kg), IV, after termination of CPB and saline (placebo) 12 hours later in the ICU; Group III, saline (placebo) IV after CPB and 12 hours later in the ICU. Blood loss and bleeding time decreased for Group I at 24 hours (P < 0.04) when compared to Group III; however, blood product replacement, as well as intraoperative and total blood loss at 36 hours, were not different among treatment and control groups. There were four myocardial infarctions recorded in Group I, two in Group II, and one in Group III. These differences were not found to be statistically significant. It is concluded that in routine CABG the prophylactic use of single or repeat dose DDAVP does not effectively decrease blood loss or blood product replacement.

Bleeding Time

Stereotactic localization and guidance using a machine vision technique.

Machine vision techniques (video cameras) can be used to determine the three-dimensional position of objects. This transformation can be accomplished with standard mathematical algorithms. Initial accuracy tests of stereotactic localization with video cameras were performed using a standard Brown-Roberts-Wells (BRW) phantom simulator coupled with the BRW angiographic localizer. Localization accuracy was within 1.5 mm. Potential applications of machine vision techniques include freehand stereotactic localization of the position and orientation of surgical instruments. With sufficient computer speed these techniques can be used for continuous monitoring of the position of instruments within the cranial vault.

Brain