Search PubMed⌕ Search

Biomedical subjects

S Kawata

Publications and source records attributed to S Kawata.

241 records · Page 14Linked to original sources

Fluorescence imaging with a laser trapping scanning near-field optical microscope.

We investigated fluorescence imaging using a near-field scanning optical microscope which uses a laser-stabilized gold nanoparticle as a near-field probe. This microscope is suitable for observations of biological specimens in aqueous solutions because the probe particle is held by a noncontact force exerted by a laser beam. Theoretical calculations based on Mie scattering theory are presented to evaluate the near-field enhancement by a gold particle of 40 nm diameter. We also present fluorescence images of a single fluorescent bead and discuss the near-field contribution to the fluorescence image in this type of microscope.

Journal Article↗

Evanescent field excitation and measurement of dye fluorescence in a metallic probe near-field scanning optical microscope.

We introduce a method of dye fluorescence excitation and measurement that utilizes a near-field scanning optical microscope (NSOM). This NSOM uses an apertureless metallic probe, and an optical system that contains a high numerical aperture (NA) objective lens (NA= 1.4). When the area which satisfies NA < 1 is masked, the objective lens allows for the rejection of possible transmitted light (NA < 1) through the sample. In such conditions, the focused spot consists of only the evanescent field. We found that this NSOM system strongly reduces the background of the dye fluorescence and allows for the measurement of the fluorescence intensity below the diffraction limit of the excitation source.

Journal Article↗

Applicability of deconvolution and nonlinear optimization for reconstructing optical images from near-field optical microscope images.

We have made a computer reconstruction of a nanometric optical image of a sample from an observed near-field optical image. The near-field microscope image used for investigation was obtained numerically in three dimensions with the finite-difference time-domain (FDTD) method. The sample is dielectric substrate containing nanometric two strips made of dielectric or metal. Deconvolution with non-negativity constraint is used to reconstruct the nanometric structure of dielectric strips, while nonlinear optimization is used to reconstruct the metallic strips. The difference in choice of reconstruction method between two samples comes from the difference in degree of interaction or multiple scattering of the sample structure and the probe. It is shown in the results, the resolution limit attainable in deconvolution is as fine as the size of aperture of probe.

Journal Article↗

Effects of chronic atenolol therapy on cardiovascular response to isometric exercise in essential hypertension.

Cardiovascular response to 2 min of isometric handgrip exercise at 50% of maximum voluntary contraction was studied echocardiographically in 10 essential hypertensives, before and during treatment with atenolol for a mean of 2 months. The patients responded with increases in heart rate, systolic and diastolic blood pressures, cardiac output and calculated triple product, no changes in stroke volume and total peripheral resistance, and decreases in ejection fraction, mean velocity of circumferential shortening and mean diastolic posterior wall velocity of the left ventricle before treatment. Chronic atenolol therapy attenuated the increases in heart rate, blood pressure and triple product, and the decreases in ejection fraction, mean velocity of circumferential shortening and mean diastolic posterior wall velocity of the left ventricle but resulted in a marked increase in total peripheral resistance. The pressure response and triple product rise in response to isometric handgrip exercise were also decreased. This suggests an obvious advantage to hypertensive patients who may, therefore, be protected from the risk of cardiovascular complications following isometric exercise.

Atenolol↗

Chondrosarcoma of the trachea. A case report and literature review.

The cytologic presentation of a case of chondrosarcoma of the trachea in a 72-year-old man is described. A mass detected on routine chest roentgenogram and defined by CT scan was used to make a touch imprint smear during partial tumor resection. The cytologic findings included round or polygonal cells with occasional binucleation, round hyperchromatic nuclei and prominent nucleoli, present in an amorphous pink-violet or light-blue background containing fragments of chondroid tissue. The histopathology was interpreted as a low-grade chondrosarcoma. Cartilaginous tumors of the trachea should be considered in the differential diagnosis of upper airway obstruction.

Aged↗

Liquid chromatographic determination of oxytetracycline in swine tissues.

A simple and rapid method was developed for determination of oxytetracycline (OTC) in swine muscle and kidney by liquid chromatography (LC). The method involved homogenization of sample in acetonitrile-1M imidazole buffer containing 10 mM disodium ethylenediaminetetraacetic acid (Na2.EDTA) and 50 mM magnesium acetate (15 + 85) with added hexane, centrifugation, removal of the hexane phase, and ultrafiltration of the supernatant. L-column ODS (150 x 4.6 mm) with a mobile phase of acetonitrile-1M imidazole buffer containing 50 mM magnesium acetate and 10 mM Na2.EDTA (10 + 90) was used for the LC separation. A fluorescence detector was used at an excitation wavelength of 380 nm and an emission wavelength of 520 nm. The calibration graph was linear from 1.25 to 200 ng OTC. Recoveries of OTC from swine tissue fortified at levels of 0.05-1.0 microgram/g ranged from 58.0 to 67.3%. The quantitation and detection limits were 0.05 and 0.04 microgram/g, respectively.

Acetonitriles↗