Search PubMed⌕ Search

Biomedical subjects

S Kasas

Publications and source records attributed to S Kasas.

14 recordsLinked to original sources

Exploring the mechanical properties of single vimentin intermediate filaments by atomic force microscopy.

Intermediate filaments (IFs), together with actin filaments and microtubules, compose the cytoskeleton. Among other functions, IFs impart mechanical stability to cells when exposed to mechanical stress and act as a support when the other cytoskeletal filaments cannot keep the structural integrity of the cells. Here we present a study on the bending properties of single vimentin IFs in which we used an atomic force microscopy (AFM) tip to elastically deform single filaments hanging over a porous membrane. We obtained a value for the bending modulus of non-stabilized IFs between 300 MPa and 400 MPa. Our results together with previous ones suggest that IFs present axial sliding between their constitutive building blocks and therefore have a bending modulus that depends on the filament length. Measurements of glutaraldehyde-stabilized filaments were also performed to reduce the axial sliding between subunits and therefore provide a lower limit estimate of the Young's modulus of the filaments. The results show an increment of two to three times in the bending modulus for the stabilized IFs with respect to the non-stabilized ones, suggesting that the Young's modulus of vimentin IFs should be around 900 MPa or higher.

Aluminum Oxide↗

Superficial and deep changes of cellular mechanical properties following cytoskeleton disassembly.

The cytoskeleton, composed of actin filaments, intermediate filaments, and microtubules, is a highly dynamic supramolecular network actively involved in many essential biological mechanisms such as cellular structure, transport, movements, differentiation, and signaling. As a first step to characterize the biophysical changes associated with cytoskeleton functions, we have developed finite elements models of the organization of the cell that has allowed us to interpret atomic force microscopy (AFM) data at a higher resolution than that in previous work. Thus, by assuming that living cells behave mechanically as multilayered structures, we have been able to identify superficial and deep effects that could be related to actin and microtubule disassembly, respectively. In Cos-7 cells, actin destabilization with Cytochalasin D induced a decrease of the visco-elasticity close to the membrane surface, while destabilizing microtubules with Nocodazole produced a stiffness decrease only in deeper parts of the cell. In both cases, these effects were reversible. Cell softening was measurable with AFM at concentrations of the destabilizing agents that did not induce detectable effects on the cytoskeleton network when viewing the cells with fluorescent confocal microscopy. All experimental results could be simulated by our models. This technology opens the door to the study of the biophysical properties of signaling domains extending from the cell surface to deeper parts of the cell.

Actins↗

Oscillation modes of microtubules.

Microtubules are long, filamentous protein complexes which play a central role in several cellular physiological processes, such as cell division transport and locomotion. Their mechanical properties are extremely important since they determine the biological function. In a recently published experiment [Phys. Rev. Lett. 89 (2002) 248101], microtubule's Young's and shear moduli were simultaneously measured, proving that they are highly anisotropic. Together with the known structure, this finding opens the way to better understand and predict their mechanical behavior under a particular set of conditions. In the present study, we modeled microtubules by using the finite elements method and analyzed their oscillation modes. The analysis revealed that oscillation modes involving a change in the diameter of the microtubules strongly depend on the shear modulus. In these modes, the correlation times of the movements are just slightly shorter than diffusion times of free molecules surrounding the microtubule. It could be therefore speculated that the matching of the two timescales could play a role in facilitating the interactions between microtubules and MT associated proteins, and between microtubules and tubulins themselves.

Animals↗

Interactions between synaptic vesicle fusion proteins explored by atomic force microscopy.

Measuring the biophysical properties of macromolecular complexes at work is a major challenge of modern biology. The protein complex composed of vesicle-associated membrane protein 2, synaptosomal-associated protein of 25 kDa, and syntaxin 1 [soluble N-ethyl-maleimide-sensitive factor attachment protein receptor (SNARE) complex] is essential for docking and fusion of neurotransmitter-filled synaptic vesicles with the presynaptic membrane. To better understand the fusion mechanisms, we reconstituted the synaptic SNARE complex in the imaging chamber of an atomic force microscope and measured the interaction forces between its components. Each protein was tested against the two others, taken either individually or as binary complexes. This approach allowed us to determine specific interaction forces and dissociation kinetics of the SNAREs and led us to propose a sequence of interactions. A theoretical model based on our measurements suggests that a minimum of four complexes is probably necessary for fusion to occur. We also showed that the regulatory protein neuronal Sec1 injected into the atomic force microscope chamber prevented the complex formation. Finally, we measured the effect of tetanus toxin protease on the SNARE complex and its activity by on-line registration during tetanus toxin injection. These experiments provide a basis for the functional study of protein microdomains and also suggest opportunities for sensitive screening of drugs that can modulate protein-protein interactions.

Antigens, Surface↗

Vitrification of cryoelectron microscopy specimens revealed by high-speed photographic imaging.

Cryoelectron microsopy is a widely used technique to observe biological material in an almost physiological, fully hydrated state. The sample is prepared for electron microsopy observation by quickly reducing its temperature to -180 degrees C. The high-speed cooling induces the formation of vitreous water, which preserves the sample conformation. However, the way vitrification occurs is still poorly understood. In order to better understand the phenomenon, we have used a stroboscopic device to visualize the interaction between the electron microscopy grid and the cryogen. By blocking the free fall of the plunger once the grid has penetrated the coolant by half its diameter, we have elucidated the way in which vitrification propagates. The findings were confirmed by numerical simulation. In addition, according to our observations, we now present an alternative way to prepare vitreous specimens. This new method, with the grid parallel to the liquid cryogen surface, decreases evaporation from the sample during its free fall towards the coolant and at the same time achieves a more uniform vitrification over the entire surface of the specimen.

Cryoelectron Microscopy↗

Nanomechanics of microtubules.

We have determined the mechanical anisotropy of a single microtubule by simultaneously measuring the Young's and the shear moduli in vitro. This was achieved by elastically deforming the microtubule deposited on a substrate tailored by electron-beam lithography with a tip of an atomic force microscope. The shear modulus is 2 orders of magnitude lower than the Young's, giving rise to a length-dependent flexural rigidity of microtubules. The temperature dependence of the microtubule's bending stiffness in the (5-40) degrees C range shows a strong variation upon cooling coming from the increasing interaction between the protofilaments.

Anisotropy↗

Examination of line crossings by atomic force microscopy.

Until now, the most widely used methods for the forensic examination of line crossings in documents were optical and electron microscopy. The combination of both techniques allows one in most cases to establish the sequence of lines. The recent development of scanning probe microscopy [1] gives an opportunity to complement or even replace the classical instruments used in this field. Scanning probe microscopes have been designed to study surfaces at high magnification. The aim of this study was to verify if their most popular member, the atomic force microscope (AFM) [2], can be applied to line crossing problems. The results show for the first time that AFM images present the same qualitative information obtained by scanning electron microscope (SEM) images and, consequently, allow the determination of the line crossing sequence under ambient conditions without vacuum and conductive coating of specimens.

Forensic Medicine↗

Direct observation of one-dimensional diffusion and transcription by Escherichia coli RNA polymerase.

The dynamics of nonspecific and specific Escherichia coli RNA polymerase (RNAP)-DNA complexes have been directly observed using scanning force microscopy operating in buffer. To this end, imaging conditions had to be found in which DNA molecules were adsorbed onto mica strongly enough to be imaged, but loosely enough to be able to diffuse on the surface. In sequential images of nonspecific complexes, RNAP was seen to slide along DNA, performing a one-dimensional random walk. Heparin, a substance known to disrupt nonspecific RNAP-DNA interactions, prevented sliding. These observations suggest that diffusion of RNAP along DNA constitutes a mechanism for accelerated promoter location. Sequential images of single, transcribing RNAP molecules were also investigated. Upon addition of 5 microM nucleoside triphosphates to stalled elongation complexes in the liquid chamber, RNAP molecules were seen to processively thread their template at rates of 1.5 nucleotide/s in a direction consistent with the promoter orientation. Transcription assays, performed with radiolabeled, mica-bound transcription complexes, confirmed this rate, which was about three times smaller than the rate of complexes in solution. This assay also showed that the pattern of pause sites and the termination site were affected by the surface. By using the Einstein-Sutherland friction-diffusion relation the loading force experienced by RNAP due to DNA-surface friction is estimated and discussed.

Adsorption↗

Escherichia coli RNA polymerase activity observed using atomic force microscopy.

Fluid tapping-mode atomic force microscopy (AFM) was used to observe Escherichia coli RNA polymerase (RNAP) transcribing two different linear double-stranded (ds) DNA templates. The transcription process was detected by observing the translocation of the DNA template by RNAP on addition of ribonucleoside 5'-triphosphates (NTPs) in sequential AFM images. Stalled ternary complexes of RNAP, dsDNA and nascent RNA were adsorbed onto a mica surface and imaged under continuously flowing buffer. On introduction of all four NTPs, we observed some DNA molecules being pulled through the RNAP, some dissociating from the RNAP and others which did not move relative to the RNAP. The transcription rates were observed to be approximately 0.5-2 bases/s at our NTP concentrations, approximately 5 microM. The RNA transcripts were not unambiguously imaged in fluid. However, in experiments using a small single-stranded (ss) circular DNA template, known as a rolling circle, transcripts up to 1 or 2 microns long could be observed with tapping mode AFM once the samples were dried and imaged in air. This confirmed our observations of the transcriptional activity of RNAP adsorbed onto mica. This work illustrates that the development of tapping-mode in fluid has made it possible to use AFM to follow biological processes at the molecular level and get new insights about the variability of activity of individual molecules bound to a surface.

Aluminum Silicates↗

A method for anchoring round shaped cells for atomic force microscope imaging.

More and more researchers are interested in imaging living (Henderson, 1994) or fixed cells in their natural environment using the atomic force microscope (AFM). However, the AFM tip interacts strongly with the sample, and its z range freedom is limited to a few micrometers. This means that the cells to be imaged have to be strongly attached to the substrate, and imaging is restricted to cells having a flattened shape. Here we propose a simple and inexpensive solution to overcome these limitations. The method we propose is trapping living round shaped cells in a Millipore filter with a pore size comparable to the dimensions of the cell. The highest part of some of the blocked cells protrude through the holes of the filter and can this way be easily observed using the AFM without detachment.

Micropore Filters↗

Further ultrastructural evidence that spirochaetes may play a role in the aetiology of Alzheimer's disease.

Recently it was reported that, at autopsy, in neuropathologically confirmed cases of Alzheimer's disease spirochaetes were found in blood and cerebrospinal fluid using dark-field microscopy. Moreover, the spirochaetes were isolated and cultured from brain tissue. We now show, using scanning electron microscopy and atomic force microscopy that the helically shaped microorganisms isolated and cultured from the Alzheimer brains possess axial filaments. This indicates that these microorganisms taxonomically indeed belong to the order Spirochaetales. A morphometric analysis reinforces this notion.

Alzheimer Disease↗

Observation of living cells using the atomic force microscope.

We used an atomic force microscope (AFM) to image samples immersed in a fluid in order to study the dynamic behavior of the membranes of living cells. AFM images of cultured cells immersed in a buffer were obtained without any preliminary preparation. We observed surface changes and displacements which suggest that the cells were still alive during the measurements. Some membrane details imaged with the AFM have also been observed using a scanning electron microscope and their dynamic behavior has been confirmed by microcinematography. We believe that the AFM will offer new insights into the exploration of dynamic changes affecting cell membranes.

Biophysical Phenomena↗

[Quantification of the intra-penile smooth muscle with a fuzzy logic algorithm].

We have developed a new computer program for tissue segmentation designed for the quantification of smooth muscle in the corpus cavernosum. The program uses digitalized images of stained histological sections taken with a CCD camera. The recognition of the different tissues is based on the examination of absorption of monochromatic light. The section is successively illuminated with light of three different wavelengths and the three absorption values and texture parameters are used for the identification of the tissue using a fuzzy algorithm.

Absorption↗

Discrete reduction patterns of parvalbumin and calbindin D-28k immunoreactivity in the dorsal lateral geniculate nucleus and the striate cortex of adult macaque monkeys after monocular enucleation.

We analyzed the immunohistochemical distribution of the two calcium-binding proteins, parvalbumin (PV) and calbindin D-28k (CB), in the primary visual cortex and lateral dorsal geniculate nucleus (dLGN) of monocularly enucleated macaque monkeys (Macaca fascicularis and Macaca nemestrina) in order to determine how the expression of PV and CB is affected by functional inactivity. The monkeys survived 1-17 weeks after monocular enucleation. The distribution pattern of each of the proteins was examined immunocytochemically using monoclonal antibodies and compared with that of the metabolic marker cytochrome oxidase (CO). We recorded manually the number of immunostained neurons and estimated the concentration of immunoreactive staining product using a computerized image-acquisition system. Our results indicate a decrease of approximately 30% in the labeling of PV-immunoreactive (ir) neuropil particularly in those layers of denervated ocular-dominance columns receiving the geniculocortical input. There was no change in the number of PV-ir neurons in any compartment irrespective of the enucleation interval. For CB-ir, we found a 20% decrease in the neuropil labeling in layer 2/3 of the denervated ocular-dominance columns. In addition, a subset of pyramidal CB-ir neurons in layers 2 and 4B, which are weakly stained in control animals, showed decreased labeling. In the dLGN of enucleated animals, PV-ir and CB-ir were decreased only in the neuropil of the denervated layers. From these results, we conclude that cortical interneurons and geniculate projection neurons still express PV and CB in their cell bodies after disruption of the direct functional input from one eye. The only distinct decrease of PV and CB expression is seen in axon terminals from retinal ganglion cells in the dLGN, and in the axons and terminals of both geniculocortical projection cells and cortical interneurons in the cerebral cortex.

Animals↗