On the statistics of ultrasonic spectral parameters.

Several factors affect the accuracy and precision of ultrasonic spectrum analysis, which is used for characterization of normal and diseased tissue in a variety of organs. For example, averaging procedures and the sequence of operations affect the accuracy and precision of spectrum analysis. Averaging procedures and logarithmic conversion (i.e., conversion to dB) introduce a constant bias that affects spectral amplitudes and the values of intercept and midband fit; the bias depends on the sequencing of the log conversion and averaging as well as the number of independent spectra or spectral parameters that are averaged. We derive expressions that permit correction of such biases. Furthermore, we show that standard deviations for slope and midband-fit estimation can be minimized by averaging spectra before dB conversion and before computing spectral parameters by linear regression. Experimental results using phantoms agree remarkably with theoretical predictions for the data window functions studied in this article, Hamming and rectangular.

Humans↗

A novel and robust method for rapid strain estimation in elastography.

In elastography, change in signal shape from tissue deformation and nonaxial tissue motion reduce correlation between the pre- and postcompression echo signals. Appropriate global temporal stretching of postcompression signals can reduce the decorrelation. Adaptive stretching performs a search for the stretch factor that maximizes the correlation between the pre- and postcompression echo signal segments at each data window location. Adaptive stretching is robust but computation intensive. In contrast, global stretching is fast but performs well only in areas where local strains are close to the applied strain. We developed a method that strikes a balance between the speed of global stretching and the performance of adaptive stretching. In this method, several strain maps are computed by performing global stretching with a range of different stretch factors. The area in each computed strain image with strain values closely corresponding to the uniform stretch factor will contain 'good quality' strain estimates. To produce a single elastogram at the end, we identify the strain map with the maximum correlation at each location and the strain value in that strain map at that location is chosen for the combined map. Results from data generated by finite-element simulation and phantom experiments demonstrate that the described strain estimator is significantly less susceptible to signal degradation than conventional strain estimators.

Algorithms↗

Adaptive spectral strain estimators for elastography.

In conventional elastography, internal tissue deformations, induced by external compression applied to the tissue surface, are estimated by cross-correlation analysis of echo signals obtained before and after compression. Conventionally, strains are estimated by computing the gradient of estimated displacement. However, gradient-based algorithms are highly susceptible to noise and decorrelation, which could limit their utility. We previously developed strain estimators based on a frequency-domain (spectral) formulation that were shown to be more robust but less precise compared to conventional strain estimators, In this paper, we introduce a novel spectral strain estimator that estimates local strain by maximizing the correlation between the spectra of pre- and postcompression echo signals using iterative frequency-scaling of the latter; we also discuss a variation of this algorithm that may be computationally more efficient but less precise. The adaptive spectral strain estimator combines the advantages of time- and frequency-domain methods and has outperformed conventional estimators in experiments and 2-D finite-element simulations.

Algorithms↗

Implementation issues in ultrasonic flow imaging.

This article addresses several implementation issues in ultrasonic flow imaging. We discuss frequency-dependent scattering and attenuation, use of interpolation for computation intensive methods and implications of the use of chirps to increase bandwidth. We also discuss wall filtering issues; our observations show that the butterfly search estimator may be capable of detecting flow in the vicinity of strong stationary scatterers (clutter) without additional processing such as wall-filtering. Illustrative examples are given for simulated and experimental data.

Algorithms↗

Radiation-force technique to monitor lesions during ultrasonic therapy.

This report describes a monitoring technique for high-intensity focused ultrasound (US), or HIFU, lesions, including protein-denaturing lesions (PDLs) and those made for noninvasive cardiac therapy and tumor treatment in the eye, liver and other organs. Designed to sense the increased stiffness of a HIFU lesion, this technique uniquely utilizes the radiation force of the therapeutic US beam as an elastographic push to detect relative stiffness changes. Feasibility was demonstrated with computer simulations (treating acoustically induced displacements, concomitant heating, and US displacement-estimation algorithms) and pilot in vitro experimental studies, which agree qualitatively in differentiating HIFU lesions from normal tissue. Detectable motion can be induced by a single 5 ms push with temperatures well below those needed to form a lesion. Conversely, because the characteristic heat diffusion time is much longer than the characteristic relaxation time following a push, properly timed multiple therapy pulses will form lesions while providing precise control during therapy.

Animals↗

Emerging ultrasound technologies for early markers of disease.

Ultrasound has been a popular clinical imaging modality for decades. It is well established as a means of displaying the macroscopic anatomy of soft-tissue structures. While conventional ultrasound methodologies (i.e., B-mode and Doppler methods) are well proven and continue to advance technically on a daily basis, e.g. by extending into higher frequencies and taking advantage of harmonic phenomena in tissues, fundamentally new ultrasound technologies also are emerging and offer exciting promise for making significant improvements in the clinical imaging of disease. These emerging methods include spectrum analysis, elasticity imaging, contrast-agent methods, and advanced flow detection and measurement techniques. Each provides independent information and, used alone, each can provide powerful new imaging capabilities; combined with each other, their capabilities may be even greater in many applications; and all in principle can be used in concert with other imaging modalities to offer the possibility of further improvements in disease detection, evaluation, and monitoring.

Contrast Media↗