Chronic amiodarone effects on epicardial conduction and repolarization in the isolated porcine heart.

Amiodarone is a potent antiarrhythmic agent with complex chronic effects, notably on repolarization and conduction, that are not fully understood. Its low arrhythmogenic potential has been related to a lack of increase in repolarization dispersion. Since its effects are not documented in pigs we conducted a mapping study of activation and repolarization in isolated perfused porcine hearts. Amio20 female pigs (n = 7) received amiodarone 20 mg/kg per day over 4 weeks while Amio50 female pigs (n = 7) received 50 mg/kg per day over 4 weeks. Concentrations of the drug encompassed values found in clinical studies. Then, activation patterns and activation-to-recovery intervals (ARI) were mapped epicardially from 128 unipolar electrograms in isolated perfused hearts in corroboration of epicardial action potential recordings. Mean ARI was longer in Amio20 experiments compared to the seven control hearts (325 +/- 11 ms vs 288 +/- 5 ms at 1,000 ms), whereas ARI dispersion was not different, being comprised between 7 and 11 ms and generating smooth gradients. In Amio50 experiments, mean ARI was further prolonged (390 +/- 10 ms at 1,500 ms) with an exaggerated reverse rate dependence concomitant with a depressant effect on the plateau of the action potential. Again, ARI dispersion did not differ from controls. Finally, the drug depressed the maximal rate of depolarization (Vmax) and slowed conduction in a rate dependent and concentration dependent fashion. In conclusion, chronic amiodarone induces Class I and Class III antiarrhythmic effects in ventricular porcine epicardium that are concentration dependent but does not affect dispersion of repolarization. This may partly explain its low arrhythmogenic potential.

Action Potentials↗

[Determinants of survival after implantation of an automatic defibrillator. Report of 127 patients].

The authors present a retrospective and longitudinal study of the predictive factors of mortality in patients having an implanted automatic defibrillator. The population comprised 127 patients implanted between September 1988 and September 1997. There were 107 men with a mean age of 57.7 +/- 13 years. The left ventricular ejection fraction was 39.3%. The proportion of coronary patients was 68%; 20% of patients had atrial fibrillation and 5% were in Class III of the NYHA classification. The indications were: resuscitated cardiac arrest (N = 56) and poorly tolerated ventricular tachycardia (N = 71). The follow-up period was 30 +/- 25 months. There were 23 early and 10 late complications. Seventy-two patients had received an electric shock; 57 had an appropriate shock. There were 23 arrhythmic storms (ventricular arrhythmia requiring at least 2 shocks in less than 24 hours) in 17 patients. The operative mortality was 1.1%; at 1 year, the global survival was 93.9 +/- 2.2%; cardiac survival was 94.7 +/- 2.1%; survival without sudden death was 98.3 +/- 1.2%. Multivariate analysis isolated predictive factors for mortality; atrial fibrillation was predictive for global mortality; an ejection fraction < 30% and the fact of having received an appropriate shock were predictive of cardiac mortality; and an arrhythmic storm was predictive of sudden death.

Adult↗

[Infections secondary to the implantation of a pacemaker: update].

Pacemaker lead infection is a major complication of endovascular permanent pacing. The incidence is less than 1% but it is a frequent disease due to the high number of pacemaker implanted. The diagnosis is difficult due to the insidious symptoms. Pacemaker infection must be systematically considered in patients with a pacemaker and symptoms of infection. Several investigations are useful for the diagnosis particularly the transesophageal echocardiography, but all investigations have a low negative predictive value. All of the implanted material must be completely removed.

Decision Trees↗

Ventricular tachycardia originating from the posteroseptal process of the left ventricle with inferior wall healed myocardial infarction.

Ventricular tachycardia (VT) substrates may form in preferential locations and similar electrocardiographic patterns may be observed when ventricular activation starts from a particular site. We examined the role of the posterior inferior process of the left ventricle in the mechanism of VT occurring after inferior wall myocardial infarction. We reviewed isochronal maps of 40 VTs obtained at surgery in 13 patients, with a 128-electrode system using epicardial sock and endocardial balloon electrode arrays. Based on the epicardial to left endocardial relation we observed 7 tachycardias in 7 patients with onset of activation over the crux of the heart. This activation mimicked excitation through a posteroseptal accessory pathway. Endocardial activation maps showed breakthroughs occurring 6 to 40 ms later and did not give evidence in favor of macroreentry. In all but 1 VT, left-axis deviation was present (-30 to -75 degrees) with a positive concordance from leads V2 to V6 (QRS wave patterns were variable in V1). These tachycardias, which were clinical in 3 of 7 cases, were interpreted as arising from the posterior inferior process of the left ventricle and successfully ablated by left septal and epicardial cryolesions. In another patient, this concept was further validated by percutaneous radiofrequency ablation of a tachycardia with the previously described morphology. In conclusion, VT may originate from the posteroseptal process of the left ventricle with inferior wall healed myocardial infarction. Because these tachycardias can be successfully eliminated, their characteristic morphologies may provide clinical markers for the identification of patient candidates to surgical or nonsurgical ablative therapy.

Adult↗

Extraction of endocardial implantable cardioverter-defibrillator leads.

Despite a growing number of implantable cardioverter-defibrillator (ICD) lead removal indications, there is no consensus about extraction techniques. We applied our experience of pacemaker lead removal to ICD leads using a superior approach with a standard extractor kit, and an inferior approach with a lasso, or a surgical extraction. Fifteen leads were removed in 11 patients during 12 procedures (1 patient was referred twice): 11 right ventricular defibrillation leads, 3 right atrial coils, and 1 atrial lead implanted with a DDD-ICD. The indication for lead extraction was insulation failure (n = 4), conductor fracture (n = 2), abdominal pocket infection (n = 4), lead endocarditis (n = 1), and replacement of an atrial coil by an atrial lead for DDD-R pacing (n = 1). One patient had surgical extraction of 2 leads because of an endocarditis with large vegetations on a DDD-ICD. In 11 other cases, 5 leads were removed using a superior approach with a standard extraction kit and 8 leads were removed by a femoral approach using a lasso alone or added to a pigtail catheter. There was no failure of explantation. One extraction attempt failed with the superior approach but was successful with a secondary inferior approach. The main difficulties encountered were due to tight adherence of the proximal coil to the venous wall and to dislodgment of passive fixation leads from their endocardial insertion. One patient had subclavian vein thrombosis after intervention; no major complication was noted. Ten patients immediately underwent reimplantation. Two patients (1 with an endocarditis and 1 free of ICD therapy for 5 years) did not have reimplantation. During a 4- to 44-month follow-up, no late complication appeared. Thus, ICD lead explantation can be performed with a good success rate, with extraction techniques similar to those used for pacemaker leads.

Aged↗

Atrial fibrillation detection and R-wave synchronization by Metrix implantable atrial defibrillator: implications for long-term efficacy and safety. The Metrix Investigators.

BACKGROUND: The long-term efficacy of atrial fibrillation (AF) detection and R-wave synchronization are critical safety requirements for the development of an implantable atrial defibrillator (IAD) for treatment of AF. METHODS AND RESULTS: The long-term efficacy of the Metrix IAD for AF detection and R-wave synchronization was tested in 51 patients. The mean duration of follow-up was 259+/-138 days (72 to 613 days). AF detection tests were performed 2240 times during observed operation with 100% specificity and 92.3% sensitivity for differentiation between sinus rhythm and AF; 2219 episodes and their electrograms stored in the device during AF detection were analyzed. The positive predictive value of the AF detection algorithm was 97.4% (lower 95% confidence limit [CL], 94.5%) in the out-of-hospital setting. A total of 242 435 R waves were analyzed for R-wave synchronization. Of these, 49% were marked for synchronized shock delivery, 82% of sinus rhythm and 36% of AF R waves, respectively. All shock markers were properly synchronized and within the R wave (overall synchronization accuracy, 100%; lower 95% CL, 99.999%). Overall, 3719 shocks have been delivered via the IAD with no instance of unsynchronized shock delivery or any episode of proarrhythmia. The observed proarrhythmic risk was 0%, with an estimated maximum proarrhythmic risk of 0.084% per shock (95% upper CL). CONCLUSIONS: The Metrix IAD can appropriately detect AF with a high specificity and sensitivity and reliably synchronize within a suitable R wave for shock delivery to minimize the risk of ventricular proarrhythmia.

Aged↗

Biventricular pacing in patients with congestive heart failure: two prospective randomized trials. The VIGOR CHF and VENTAK CHF Investigators.

Epidemiologic studies suggest that 20-30% of patients diagnosed with symptomatic congestive heart failure (CHF) have intraventricular conduction disorders characterized by a discoordinate contraction pattern and wide QRS. Biventricular pacing is an emerging therapy allowing simultaneous electrical stimulation of the right and left ventricles with the use of an implantable pacing system. The aim of this article is to describe 2 prospective randomized multicenter trials examining the effects of biventricular pacing on functional capacity, quality of life, and hemodynamic status in patients with dilated cardiomyopathy and intraventricular delay. The VIGOR CHF Trial is designed to assess functional and symptomatic improvement in heart failure patients with biventricular pacing and without a concomitant indication for conventional bradycardia pacemaker therapy. To assess for potential placebo effects, patients are randomized to receive either biventricular pacemaker therapy or no pacing therapy for the first 6 weeks, after which both groups receive pacing therapy. The VENTAK CHF trial uses an implantable cardioverter defibrillator system (ICD) designed to provide chronic biventricular pacing therapy in addition to treating ventricular tachyarrhythmias. All patients receive conventional ICD and CHF therapy throughout the study and are randomized in a 2-period crossover design to receive either no pacing or biventricular pacing for 3-month intervals. Patient enrollment in both studies is ongoing, with a closed analysis. The unique designs of these trials provide the opportunity to study this therapy in high-risk patients who have been optimally treated for heart failure.

Adult↗

Factors affecting epicardial dispersion of repolarization: a mapping study in the isolated porcine heart.

OBJECTIVE: Non-uniform drug-induced prolongation of repolarization predominating in the midmyocardial (M) cell layers has been shown to be responsible for perpetuation of reentry, giving rise to torsade de pointes. However, the absence of M cells in immature animals, especially the pig, suggests other possible underlying mechanisms. We sought to examine, in this species, the effects of predisposing factors to torsade de pointes on the dispersion of epicardial repolarization and their contribution to arrhythmogenesis. METHODS: Computerized mapping of repolarization and activation was conducted on the epicardial surface in 29 Langendorff-perfused hearts of eight-week-old pigs. Activation-recovery intervals were measured simultaneously from 128 unipolar electrograms. RESULTS: Baseline iso-interval maps were dipolar (41%) or multipolar (59%). Dispersion of repolarization was reverse frequency-dependent but was unaffected by lowering [K+]o. DL-Sotalol (0.1 mmol/l) reinforced local gradients and thus increased epicardial dispersion, whereas intramural recordings did not demonstrate any predominant effect in midmyocardial layers. Phenylephrine (1 mumol/l) notably augmented DL-sotalol effects. After [Mg++]o lowering, although dispersion was not significantly increased, DL-sotalol was associated with the spontaneous occurrence of polymorphic ventricular tachycardia in seven out of nine experiments. When maps of repolarization of escape beats were compared with activation maps of first arrhythmic beats, an arc of functional dissociation was observed in the vicinity of a steep gradient of repolarization in two out of nine tachycardias. CONCLUSION: Epicardial dispersion of repolarization is increased by slow rates, DL-sotalol and phenylephrine but is not the only requirement for initiation of polymorphic ventricular tachycardia. In combination with other factors, it helps continuation of the arrhythmia in this model.

Adrenergic alpha-Agonists↗

Single center experience with femoral extraction of permanent endocardial pacing leads.

Between March 1995 and June 1997, 128 leads were extracted from the hearts of 28 women and 50 men, 69 +/- 15 years of age (mean +/- SD, range 22-92 years). The indications for the procedure were: Accufix leads in 18 patients (14%), dysfunction or incompatibility with ICD in 16 (12%), endocarditis on the lead in 41 (32%), pulse generator pocket infection in 28 (22%), and pulse generator and/or lead erosion in 25 patients (19%). The extraction was performed with a snare (lasso), via a femoral vein as a first approach in 116 leads, and as an alternate approach, after extraction from the original site of implantation had failed, in 12 leads. The leads had been implanted for 62 +/- 48 months (range 1-205 months). A Cook sheath was used in 7, and a femoral approach traction in 20 instances. Of the 128 leads, 122 (95%) were completely extracted, and 2 (2%) were partially extracted (the distal electrode remaining attached to the myocardium), and 4 (3%) could not be removed. Four complications occurred: 2 tears of the tricuspid valve without clinical consequences, one separation of the lead's distal electrode which migrated into the hypogastric vein, and one hemorrhage at the femoral puncture site. There was no death or serious complication caused by lead extraction in this series.

Adult↗

Extraction and reimplantation of defibrillation leads through a thrombotic subclavian vein.

Venous thrombosis is one of the most frequently encountered obstacles when reintervening on endocardial leads. We report on two patients with a ventricular defibrillator requiring lead replacement in whom a subclavian vein thrombosis was documented prior to the intervention. We recanalized the vein and replaced the lead through the same path to preserve the venous access.

Defibrillators, Implantable↗

Intraoperative computerized mapping of ventricular tachycardia: differences between anterior and inferior myocardial infarctions.

INTRODUCTION: Although direct ventricular tachycardia (VT) surgery has been shown to be effective for treatment of inferior myocardial infarction (MI), the differences in the arrhythmia substrates compared to anterior MI have not been systematically delineated. We sought to compare operative procedures and VT substrates between anterior and inferior MI locations. METHODS AND RESULTS: Computerized mapping was performed in 30 patients with a 128-electrode system using epicardial sock and transatrial left ventricular endocardial balloon arrays, followed by combined endocardial resection and cryoablation. At surgery, there were 51 and 34 different VTs in 18 patients with anterior MI and 12 patients with inferior MI, respectively. The proportion of aneurysms was lower in inferior MI (25% vs 78%, P = 0.008). Total activation times accounted for 65% +/- 23% and 50% +/- 22% of the VT cycle length in anterior and inferior infarcts, respectively (P = 0.005). Complete superficial reentry was identified in 12 VTs related to anterior infarcts and in only two VTs associated with inferior infarction (P = 0.038). Involvement of papillary muscles occurred in two patients with inferior MI. Patients with inferior infarcts received more cryolesions and required epicardial cryolesions or mitral valve replacement more frequently, and their operative mortality was greater (2/12 vs 0/18). Noninducibility rate (89.3%) and 2-year survival (76% +/- 8%) did not differ according to infarct location. CONCLUSION: VT associated with inferior MI can be ablated successfully; however, the substrate is more complex, with frequent participation of intramural layers rendering the ablative procedure more difficult.

Adult↗

Inadequate sympathovagal balance in response to orthostatism in patients with unexplained syncope and a positive head up tilt test.

AIM: To analyse the immediate response of heart rate variability (HRV) in response to orthostatic stress in unexplained syncope. SUBJECTS: 69 subjects, mean (SD) age 42 (18) years, undergoing 60 degrees head up tilt to evaluate unexplained syncope. METHODS: Based on 256 second ECG samples obtained during supine and upright phases, spectral analyses of low (LF) and high frequency (HF) bands were calculated, as well as the LF/HF power ratio, reflecting the sympathovagal balance. All variables were measured just before tilt during the last five minutes of the supine position, during the first five minutes of head up tilt, and just before the end of passive tilt. RESULTS: Symptoms occurred in 42 subjects (vasovagal syncope in 37; psychogenic syncope in five). Resting haemodynamics and HRV indices were similar in subjects with and without syncope. Immediately after assuming the upright posture, adaptation to orthostatism differed between the two groups in that the LF/HF power ratio decreased by 11% from supine (from 2.7 (1.5) to 2.4 (1.2)) in the positive test group, while it increased by 11.5% (from 2.8 (1.5) to 3.1 (1.7)) in the negative test group (p = 0.02). This was because subjects with a positive test did not have the same increment in LF power with tilting as those with a negative test (11% v 28%, p = 0.04), while HF power did not alter. A decreased LF/HF power ratio persisted throughout head up tilt and was the only variable found to discriminate between subjects with positive and negative test results (p = 0.005, multivariate analysis). During the first five minutes of tilt, a decreased LF/HF power ratio occurred in 33 of 37 subjects in the positive group and three of 27 in the negative group. Thus a decreased LF/HF ratio had 89% sensitivity, 89% specificity, a 92% positive predictive value, and an 86% negative predictive value. CONCLUSIONS: Through the LF/HF power ratio, spectral analysis of HRV was highly correlated with head up tilt results. Subjects developing syncope late during continued head up tilt have a decrease in LF/HF ratio immediately after assuming the upright posture, implying that although symptoms have not developed the vasovagal reaction may already have begun. This emphasises the major role of the autonomic nervous system in the genesis of vasovagal (neurally mediated) syncope.

Adolescent↗

[Complete atrioventricular block during temporal lobe epilepsy. Apropos of a case].

The authors report the case of a 37 years old woman with no previous medical history, admitted to hospital for investigation of unexplained syncope, sometimes associated with generalised fits. After standard non-invasive cardiovascular investigations, no diagnosis could be made. The tilt test induced a minor syncopal episode without reproducing the clinical symptoms. In view of the discordance between the induced and spontaneous symptoms, a neurological opinion was requested. During the recording of an electroencephalogram, syncopal atrioventricular block was observed, preceded by auditory hallucinations, reproducing exactly the clinical symptoms. Analysis of the sequence of events showed the conduction defect to arise after the onset of the epileptic fit, indicating a diagnosis of syncopal complete atrioventricular block complicating cryptogenic temporal epilepsy, and requiring specific treatment. This case illustrates the importance of close collaboration between cardiologists and neurologists in the management of cases of unexplained syncope.

Adult↗

[Mapping and radiofrequency ablation in different forms of right peri-atriotomy flutter].

Peri-atriotomy flutter is a possible complication of surgical atriotomy. This tachycardia in an indication for radiofrequency ablation. The aim of this study was to determine the mechanism of the flutter, evaluate the possibility of mapping and the role of radiofrequency ablation in its treatment. Eleven patients with a mean age of 45 years (26-70) were referred for ablation of atrial flutter observed on average 15 years after surgical atriotomy. In 7 patients (Group I), the ECG appearances before the procedure were that of a rare flutter. Endocavitary mapping showed a circuit limited to the free wall of the right atrium with a posterior caudo-cranial and an anterior cranio-caudal front. A series of radiofrequency applications joining the atriotomy scar to the inferior vena cava interrupted the flutter in all patients and created a bidirectional block around the atriotomy. In 4 patient (Group II), the ECG appearances were that of a common flutter. A series of radiofrequency ablations in the cavo-tricuspid isthmus led to sudden change in polarity of the F wave in all patients. Repeat mapping then showed a peri-atriotomy circuit identical to that described in Group I. The whole was interpreted as a figure-of-eight circuit. The primary success rate was 100%. There were no complications but the early recurrence rate remained high. This preliminary experience confirms the value of radiofrequency ablation in the treatment of peri-atriotomy flutter and shows ECG polymorphism related to a figure-of-eight reentry circuit.

Adult↗

[Ventricular tachycardia revealing viral myocarditis].

BACKGROUND: The first diagnostic hypothesis in a middle-aged patient presenting with inaugural ventricular tachycardia would be coronary artery disease. If the work-up lacks arguments for this etiology, other cardiac conditions may be involved (dilated cardiopathy, hypertrophic cardiopathy, valve disease arrhythmogenic dysplasia, long QT...). CASE REPORT: A 52-year-old male patient was referred for inaugural ventricular tachycardia. The initial work-up including echocardiography, coronography and the electrophysiologic study provided no explanation. The ventricular tachycardia was later attributed to viral myocarditis. DISCUSSION: Viral myocarditis should always be entertained in patients with unexplained ventricular tachycardia, particular if a viral context is present. In such cases, antibody-labeled scintigraphy is the choice exploration. This noninvasive technique provides determining diagnostic information and helps orient patient management.

Adrenergic beta-Antagonists↗

Single radiofrequency application to cure atrioventricular nodal reentry: arguments for the slow pathway origin of the high-low frequency slow potentials.

BACKGROUND: High-low frequency slow potentials are thought to be related to the slow AV pathway conduction. Their use was proposed to guide radiofrequency (RF) ablation of atrioventricular nodal reentrant tachycardia (AVNRT). The present study was designed to determine the prospective value of these high-low frequency slow potentials to guide AVNRT ablation using a single RF application. Single RF application could indeed reduce the size of the lesion created in the viciny of the specialized AV conduction system and shorten the radiation exposure and the overall duration of the procedure. RESULTS: Forty-one patients (14 men, 27 women, 45 +/- 16 years old) with AVNRT underwent slow pathway RF ablation guided by high-low frequency slow potentials. High-low frequency slow potentials were found in all patients along the tricuspid annulus and above the coronary sinus. Ablation was always performed in the posterior part of Koch's triangle. The mean A/V amplitude ratio of the successful site was 0.43 +/- 0.59. In 32 patients (78%) AVNRT was no longer inducible after a single RF application. Procedure and radiation times were 35 +/- 31 and 13 +/- 12 min respectively. Five patients required 2, 3 patients 3, and 1 patient 6 RF applications. The mean number of RF applications was 1.4 +/- 0.9 (median = 1). In the 32 patients who required only one RF application, 24 (75%) had an obvious dual AV nodal pathways with a jump before ablation, which completely disappeared in 18 of them (75%) after ablation. In the 6 remaining patients, who still had a jump after 1 RF application, there was no significant change in either conduction times or refractory periods concerning both the anterograde and retrograde AV conduction. No patient had PR interval purlongation. After a mean follow up of 11 +/- 5 months, recurrence was observed in a single patient who received 2 discontinued RF applications. CONCLUSION: Catheter-mediated ablation of AVNRT using high-low frequency slow potentials to localize the slow AV pathway is feasible and safe. Using this technique, a single RF application was successfull in 78% of patients, and slow pathway characteristics were completely eliminated in 75% of patients. The radiation time and the procedure duration were short. This suggest that, in patients with AVNRT, the choice of an appropriate RF target can reduce procedural duration.

Action Potentials↗

Inadvertent implantation of an ICD lead in the great cardiac vein.

We report an implantable cardioverter defibrillator (ICD) implanted with a single lead inadvertently introduced in the great cardiac vein. No venous lesion was caused by the shocks and the position of the lead remained stable. This case emphasizes the usefulness of different fluoroscopic views during ICD implantation.

Coronary Vessels↗