Computer model for glucose-limited growth of a single cell of Escherichia coli B/r-A. Reprinted from Biotechnology and Bioengineering, Vol. 26, Issue 3, Pp 203-216 (1984).

A computer model is described which is capable of predicting changes in cell composition, cell size, cell shape, and the timing of chromosome synthesis in response to changes in external glucose limitation. The model is constructed primarily from information on unrestricted growth in glucose minimal medium. The ability of the model to make reasonable quantitative predictions under glucose-limitation is a test of the plausibility of the basic biochemical mechanisms included in the model. Such a model should be of use in differentiating among competing hypotheses for biological mechanisms and in suggesting as yet unobserved phenomena. The last two points are illustrated with the testing of a mechanism for the control of the initiation of DNA synthesis and predictions on cell-width variations during the division cycle.

Computer Simulation↗

Developments in sensor-driven pacing.

This article reviews the recent major developments in the field of rate adaptive pacing. Including, the improved instrumentation of existing sensors, the use of multiple sensors to enhance sensor specificity or sensitivity, and the automation of sensor calibration. The physiologic benefits and programming of rate adaptive pacing are reviewed.

Algorithms↗

Efficacy and tolerability of continuous overdrive atrial pacing in atrial fibrillation.

Overdrive right atrial pacing has been used to prevent atrial fibrillation, but its efficacy in atrial fibrillation prevention and the patient tolerability and quality of life during high rate pacing remain uncertain. The objective of this study was to test the effects of a consistent atrial pacing algorithm that automatically paced the atrium at 30 ms shorter than the sinus P-P interval for atrial fibrillation prevention. Fifteen patients with sick sinus syndrome implanted with a Thera DR (model 7940 or 7960, Medtronic Inc.) were randomly programmed to rate adaptive dual chamber pacing (DDDR) or DDDR + consistent atrial pacing mode, each for an 8-week study period. The efficacy of consistent atrial pacing was assessed by the number of automatic mode switching and the number of premature atrial complexes. Symptoms and quality of life were assessed by the SF-36 quality of life questionnaire and an atrial fibrillation symptom checklist. The percentage of atrial pacing increased from 57 +/- 32% to 86 +/- 28%. Overall, there was no significant difference in the number of automatic mode switching episodes between DDDR and DDDR + consistent atrial pacing (47 +/- 90 vs 42 +/- 87, P > 0.05), but a significant reduction in premature atrial complexes by 74.7% (P < 0.001). There was no undue increase in atrial rate by the DDDR + consistent atrial pacing mode versus DDDR (63 +/- 13 vs 70 +/- 7 bpm). There was no significant difference in quality of life scores and symptom severity on frequency between the two modes of pacing, but a trend towards a lower frequency of symptoms in the DDDR + consistent atrial pacing mode compared with baseline (29.5 +/- 10.2 vs 25.1 +/- 9.7, P = 0.07). An algorithm that provides consistent atrial overdrive pacing can suppress atrial fibrillation triggering premature atrial complexes without the need to increase the overall atrial rate compared with conventional pacing. The algorithm appears to be well-tolerated, but further studies are needed to address the clinical impact of this atrial fibrillation prevention algorithm.

Aged↗

A comparative study on the behavior of three different automatic mode switching dual chamber pacemakers to intracardiac recordings of clinical atrial fibrillation.

Automatic mode switching (AMS) allows patients with dual chamber pacemakers who develop paroxysmal AF to have a controlled ventricular rate. The aim of this study was to (1) compare the rate-controlled behavior of three AMS algorithms in response to AF, in terms of speed and stability of response and resynchronization to sinus rhythm, and (2) compare the influence of pacemaker programming on optimal mode switching. We studied 17 patients (12 men, 5 women; mean age 59 +/- 15 years) who developed AF during electrophysiological study. Unfiltered bipolar atrial electrograms during sinus rhythm and AF were recorded onto high fidelity tapes and replayed into the atrial port of three dual chamber pacemakers with different mode switching algorithms (Thera, Marathon, Meta). The Thera pacemaker uses rate smoothing, and mode switches occur when mean sensed atrial rate exceeds the predefined AMS rate (MR). Marathon mode switches after a programmable number of consecutive rapid atrial events (NR). Meta DDDR monitors the atrial rate by a counter for atrial cycles faster than the programmed AMS rate. It increases or decreases the counter if the atrial cycle length is shorter or longer than the programmed AMS interval, respectively. Mode switch occurs when the AF detection criteria are met (CR). A total of 260 rhythms were studied. NR was significantly faster than MR and CR (latency 2.5 +/- 3 s vs 26 +/- 7 s vs 15 +/- 22 s, respectively, P < 0.0001). During sustained AF, MR resulted in the most stable and regular ventricular rhythm compared to NR or CR. In CR, ventricular rate oscillated between AMS and atrial tracking (cycle length variations: 44 +/- 2 s vs 346 +/- 109 s vs 672 +/- 84 s, P < 0.05). At resumption of sinus rhythm, MR resynchronized after 143 +/- 22 s versus 3.4 +/- 0.7 s for NR and 5.9 +/- 1.1 s for CR, resulting in long periods of AV dissociation when a VVI/VVIR mode is used after AMS. Programming of atrial refractory periods did not affect AMS response, although the speed of AMS onset can be adjusted by programming of onset criteria in the Meta DDDR. AMS algorithms differ in their ability to handle recorded clinical atrial arrhythmias. The rapid-responding algorithm exhibits rate instability, whereas slow responding algorithm shows a long delay in response and risk of AV dissociation. Thus different instrumentation of AMS may have clinical implications in patients with dual chamber pacemakers who develop AF.

Adult↗

Is automatic mode switching effective for atrial arrhythmias occurring at different rates? A study of the efficacy of automatic mode and rate switching to simulated atrial arrhythmias by chest wall stimulation.

Automatic mode switching (AMS) is a useful means to avoid rapid ventricular response during atrial fibrillation (AF), but AMS cannot occur if the detected atrial rate during AF is below the mode switching criteria. This may be the result of antiarrhythmic medications, or when the atrial events fall within the atrial blanking period, or if the atrial amplitudes during AF are too small to be sensed. We hypothesize that the addition of an automatic rate switching (ARS) algorithm may complement AMS response during AF with different detected atrial rates. We studied the Marathon DDDR pacemaker (Model 294-09, Intermedics Inc.) with the AMS and ARS algorithms that are independently programmable but can also operate in combination. AF sensed above the AMS rate (160 beats/min) will lead to VDIR pacing, whereas AF below AMS rate will be tracked at an interim rate as dictate by the ARS, at a ventricular response that is 20 beats/min above the sensor indicated rate. Atrial tachyarrhythmias were simulated by chest wall stimulation (CWS). CWS was applied to 33 patients (16 men, 17 women, mean age 69 +/- 11 years) with a Marathon DDDR pacemaker using an external pacer to simulate AF occurring at two rate levels: above the AMS rate (programmed at 160 beats/min) at 180 beats/min and below the AMS rate at 120 beats/min. The maximum, minimum, and mean ventricular rates during CWS in DDDR mode with AMS alone, ARS alone, and their combination were compared. During CWS at 120 beats/min, the AMS plus ARS setting showed a mean ventricular rate of 79 +/- 3 beats/min and 124 +/- 14 beats/min in the AMS setting alone (P < 0.01). With CWS at 180 beats/min, the mean ventricular rate in the AMS plus ARS setting compared to the AMS setting alone was not significantly different. However, the variation in ventricular pacing rate was 7 +/- 14 beats/min in the AMS plus ARS setting and 40 +/- 42 beats/min in the AMS setting (P < 0.05). In conclusion, AMS is effective for simulated atrial tachyarrhythmias sensed above the AMS rate. Combined AMS with ARS is useful to handle simulated atrial tachyarrhythmia at a slower rate and to avoid rate fluctuation during AMS. There is also a possibility that this can be applied to the naturally occurring atrial tachyarrhythmias.

Aged↗

Initial clinical experience with a new self-retaining left ventricular lead for permanent left ventricular pacing.

This study evaluated the performance of a new lead for permanent left ventricular (LV) pacing via the coronary sinus (CS) in four men and nine women (mean age = 71 +/- 13 years) with sick sinus syndrome. It consists of a 75-cm-long, 4.8-Fr, unipolar ventricular lead with a distal portion preshaped in an S curve to provide steerability and stability within the CS. Its efficacy and stability for permanent LV pacing were tested at implant, predischarge, and at 1, 3 and 6 months of follow-up. The lead was successfully implanted in 11/13 patients (85%) within a mean fluoroscopy time of 35 +/- 22 minutes. The final positions of the electrodes at the tip of the lead within venous tributaries of the CS were: (1) anterior (n = 2, 18%); (2) posterolateral (n = 5, 45%); and (3) the lateral (n = 4, 36%). Unsuccessful implants were due to unstable lead position (n = 1), or high pacing threshold (n = 1). There was no postprocedural lead dislodgment or significant changes in the R wave amplitude, LV pacing threshold and lead impedance up to 6 months of follow-up. In summary, this initial experience suggests that this new lead offers safe and reliable permanent LV pacing via the CS in the majority of patients and may be used in isolation or in conjunction with right ventricular pacing for biventricular synchronization.

Aged↗

Automatic optimization of resting and exercise atrioventricular interval using a peak endocardial acceleration sensor: validation with Doppler echocardiography and direct cardiac output measurements.

Peak endocardial acceleration (PEA) measured by an implantable acceleration sensor inside the tip of a pacing lead reflects ventricular filling and myocardial contractility. The contribution of the plateau phase of PEA as an indicator of optimal ventricular filling, hence of the appropriate atrioventricular interval (AVI) at rest and during exercise, was studied in 12 patients (age 69 +/- 6 years) with complete AV block and a PEA sensing DDDR pacemakers (Living 1 Plus, Sorin Biomedica). At a mean resting heart rate of 79 +/- 15 beats/min, the mean AVI optimized by PEA versus Doppler echocardiography (echo) were identical (142 +/- 37 vs 146 +/- 26 ms, P = 0.59). During submaximal exercise at a mean heart rate of 134 +/- 6 beats/min, AVI optimized by PEA was 135 +/- 37 ms. Cardiac output at rest, measured by the CO2 rebreathing method, was comparable with AVI determined by echo versus PEA (4.3 +/- 2.9 and 3.7 +/- 2.4 L/min, respectively), and increased to the same extent (8.0 +/- 3.9 vs 8.3 +/- 5.2 L/min) during submaximal exercise. In patients with AV block, AVI automatically set by PEA was comparable with AVI manually optimized by Doppler echocardiography and was associated with comparable exercise induced hemodynamic changes.

Aged↗

Experience with a single-pass, dual-electrode implantable atrial defibrillator lead for maintaining sinus rhythm in patients with recurrent atrial fibrillation.

The implantable atrial defibrillator is a new potential nonpharmacologic treatment for recurrent atrial fibrillation. The results of this study suggest that a simplified lead configuration, with a single-pass, dual-electrode atrial defibrillation lead can be used for both atrial fibrillation detection and defibrillation with an implantable atrial defibrillator.

Adult↗

Improved efficacy of mode switching during atrial fibrillation using automatic atrial sensitivity adjustment.

Automatic mode switching (AMS) during atrial fibrillation (AF) in a dual chamber pacemaker is dependent on the accurate detection of an atrial electrogram. As atrial amplitude is often reduced during AF compared with sinus rhythm, this may result in failure of the AMS and a rapid ventricular response. In addition, undersensing of AF may result in competitive atrial pacing that sustains AF. We hypothesize that the use of automatic atrial sensitivity adjustment (ASA) may enhance AF sensing in a dual chamber pacemaker. We studied the AMS response with and without ASA of the Marathon DDDR (model 294-09, Intermedics, Inc.) pacemaker in 10 patients with paroxysmal AF. Intracardiac atrial electrograms during sinus rhythm and induced AF were recorded onto an analog tape recorder. They were replayed into the pacemaker to assess the AMS response at various starting atrial sensitivities from 3.5 to 0.8 mV with ASA activated and without. Atrial amplitude was reduced during AF. The higher the initial atrial sensitivity, the better is the AMS response and the lower the incidence of AF undersensing. The percentage of AMS before ASA ranged from 2.1% at an atrial sensitivity 3.5 mV to 95.6% at highest sensitivity of 0.5 mV (P < 0.05). After 10 minutes of ASA, the AMS response was improved from 1.7% to 50.6% and from 9.5% to 50.9% at starting atrial sensitivities of 3.5 mV and 2.5 mV, respectively (P < 0.05 in both instances). Undersensing during AF was also significantly reduced after ASA from 70% to 10% at a sensitivity of 3.5 mV and from 33.8% to 10.8% at 2.5 mV. There was no increase in oversensing. In four patients with paroxysmal AF with an implanted pacemaker, ASA improved AMS response in patients with a low implant atrial amplitude. In conclusion, efficacy of mode switching and AF sensing are dependent on the programmed atrial sensitivity, which can be enhanced with the use of ASA, particularly when P wave sensing during AF is borderline.

Adult↗

Resin-ionomer restorative materials for children: a review.

Hybrid restorative materials comprising resins and components of conventional glass ionomers have been widely introduced and accepted by the dental profession in recent years. These include the resin-modified glass ionomer cements and the polyacidmodified resin composites or compomers. They are developed in an attempt to overcome the problems of traditional restoratives, such as moisture sensitivity and reduced early strength, while at the same time maintaining their clinical advantages of command setting, adhesion to tooth structures, adequate strength to occlusal load, fluoride release and aesthetics. This paper reviews the development, composition and properties of these new materials. Their clinical performance appears to be promising and they should be considered as good alternatives to amalgam and other conventional restorative materials in the future.

Biocompatible Materials↗

An integrated dual sensor system automatically optimized by target rate histogram.

The use of combined sensors and advanced algorithms using different principles can improve rate performance over a single sensor system. Combinations of sensors and more sophisticated algorithms, however, invariably increase the complexity of pacemaker programming. An automatically optimized combined minute ventilation and activity DDDR pacemaker was developed to minimize repeated sensor adjustment. The device used subthreshold (below cardiac stimulation threshold) lead impedance to detect lead configuration at implantation automatically, followed by "implant management," including setting of lead polarity and initiation of DDDR pacing. Automatic sensor adaptation was achieved by programming a "target rate histogram" based on the patient's activity level and frequency of exertion, and the rate profile optimization process matched the recorded integrated sensor response to the target rate histogram profile. In nine patients implanted with the DX2 pacemakers, the implant management gave 100% accuracy in the detection of lead polarity. Rate profile optimization automatically increased the pacing rate during exercise between discharge and 3-month follow-up (hall walk: 78 +/- 3 vs 98 +/- 3 beats/min, and maximal treadmill exercise: 89 +/- 6 vs 115 +/- 5 beats/min, P < 0.001) with a significant increase in exercise duration during maximal exercise (7.18 +/- 1 min vs 9.56 +/- 2 min, P = 0.05). The accuracy of rate profile optimization versus manual programming was assessed at 1 month, and there was no significant difference between pacing rate kinetics and maximal pacing rate between the two methods of programming. In conclusion, pacemaker automaticity can be initiated at implantation and the self-optimized rate adaptive response appeared to be comparable to that derived from a manual programming procedure, which may reduce the need to perform time consuming sensor programming.

Aged↗

Cardiac output is a sensitive indicator of difference in exercise performance between single and dual sensor pacemakers.

Although multisensor pacing may compensate the inadequacy of rate adaptation in a single sensor system, the clinical role of multisensor driven rate adaptive pacing remains unclear. We compared the performance between single sensor and dual sensor driven pacemakers using exercise cardiac output (CO) as a marker of cardiac performance. Eight patients with a mean age of 63 +/- 3 years implanted with a dual sensor pacemaker driven by combined activity (ACT) and QT interval sensors were studied in the ACT-, QT- only and the dual QT + ACT-VVIR modes. Patients performed submaximal and maximal exercise tests with CO assessed by carbon dioxide rebreathing method. Comparing the HR response based on the change in metabolic workload, the ACT-VVIR "overpaced," the QT-VVIR "underpaced," and the QT + ACT-VVIR achieved the best approximation to normal. The percentages of CO increase in ACT-VVIR and QT + ACT-VVIR modes over resting CO were higher at 1 minute of exercise (295 +/- 85% and 165 +/- 49%, respectively) compared to the QT-VVIR mode (81 +/- 40%, P < or = 0.05). During exercise, stroke volume changes from baseline were similar between ACT-VVIR and QT + ACT-VVIR modes, but a compensatory increase in stroke volume occurred in the QT-VVIR mode during submaximal exercise (50 +/- 11 mL vs 24 +/- 17 mL in the QT + ACT-VVIR and 14 +/- 4 in ACT-VVIR, P < or = 0.003). There was no difference in the maximal exercise workload, exercise duration and CO at the submaximal and maximal exercise between the 3 sensor modes. Thus, exercise capacity is a poor indicator of sensor performance while CO measurement is a sensitive indicator of sensor mode differences especially at low workload exercise. The ACT-VVIR gave the fastest increase in CO at start of exercise at the expanse of overpacing, whereas the "under-paced" QT-VVIR compensated for the slower rate increase by utilizing contractility reserve during submaximal exercise. Dual sensor pacing, by achieving the best heart rate to workload relationship, provided a CO response without overpacing or using contractility reserve during exercise.

Adaptation, Physiological↗

Programmed atrial sensitivity: a critical determinant in atrial fibrillation detection and optimal automatic mode switching.

Automatic mode switching (AMS) prevents tracking of paroxysmal atrial fibrillation (AF) in dual chamber pacing. The correct detection of AF can be affected by the programmed atrial sensitivity (AS). We prospectively studied the relationship between AS, AF undersensing, and AMS, using unfiltered bipolar intracardiac atrial electrograms recorded from 17 patients during sinus rhythm (SR) and in AF. Overall, 780 rhythms were recorded and replayed onto three dual chamber pacemaker models using different AMS algorithms (Thera DR 7940, Marathon DDDR 294-09, and Meta DDDR 1254), and the ventricular responses were measured. AS was randomly programmed in steps from the highest available AS to half of the mean atrial P wave amplitude (PWA), and the percentage of appropriate AMS responses (defined as a ventricular pacing rate at the expected AMS mode) were recorded. AMS efficacy was related to the programmed AS settings in an exponential manner. At low AS settings, a higher percentage of tests were associated with absence of, or with intermittent AMS and tracking of AF, whereas at higher AS, oversensing of noise during SR occurred. An optimal AS measured approximately 1.3 mV, representing about one-third of the PWA measured during SR, although oversensing of SR and undersensing of AF continued to occur in 14% of tests and time, respectively, due to the high variation in PWA during AF. Thus, a fixed AS cannot eliminate AF undersensing without inviting noise oversensing, suggesting the need for automatic adjustments of AS, or the use of a rate-limiting algorithm to prevent rate oscillation during intermittent AF sensing. In conclusion, AMS functions of existing pacemakers were significantly limited by the undersensing of AF and oversensing of noise. Proper adjustment of the AS is important to enable effective AMS during AF.

Algorithms↗

Interference of cellular phones with implanted permanent pacemakers.

BACKGROUND AND HYPOTHESIS: Occasional reports have suggested that cellular phones may interfere with permanent pacemakers. Our investigation sought to determine systematically the effects of commercially available cellular phones on the performances of different pacing modes and sensing lead configurations of permanent implanted pacemakers. METHODS: We conducted the study in 29 patients implanted with single- or dual-chamber bipolar rate-adaptive permanent pacemakers (a total of nine different models and six different sensors: minute ventilation, activity sensing using either accelerometer or piezoelectric crystal, QT and oxygen saturation sensing) from four different manufacturers. Three different cellular phones with analog or digital coding with maximum power from 0.6 to 2 W were used to assess the effect of pacemaker interference. Each cellular phone was positioned at (1) above the pacemaker pocket, (2) the ear level ipsilateral to the pacemaker pocket, and (3) the contralateral ear level. Surface electrocardiograms, intracardiac electrograms, and marker channels were recorded where possible during the following maneuvers at each position: (1) calls made by a stationary phone to cellular phone, and (2) calls made from the cellular phone to a stationary phone. A total of eight different pacing modes [DDD(R), VDD(R), AAI(R) and VVI(R)] in both unipolar and bipolar sensing configurations was tested. RESULTS: Interference was demonstrated during cellular phone operation in 74 of 2,418 (3.1%) episodes in eight patients. Three types of interference were observed: inhibition of pacing output, rapid ventricular tracking in DDD(R) or VDD(R) mode, and asynchronous pacing. All were observed only with the cellular phone positioned above the pacemaker pocket. Interference occurred prior to and after the termination of the ringing tone of the cellular phone in 57% of cases. Cellular phones with either digital or analog technology could cause interference. Unipolar atrial lead was most susceptible to interference (relative frequency of interference: unipolar 1.8%, bipolar 0.4%, p < 0.05; atrial 2.9%, ventricular 1%, p < 0.05). There was no sensor-driven rate acceleration during all tests. In all patients, reprogramming of the sensitivity level successfully prevented cellular phone interference. CONCLUSIONS: Commercially available cellular phones can cause reversible interference to implanted single- or dual-chamber permanent pacemakers. The effect is maximal with high atrial unipolar sensitivity, especially in single pass VDD(R) systems. Both digital and analog cellular phones can lead to interference. Pacemaker interference can occur prior to a warning sign (ringing tone) of the phone and may have significant implications in patient safety.

Adult↗

Comparative evaluation of acute and long-term clinical performance of two single lead atrial synchronous ventricular (VDD) pacemakers: diagonally arranged bipolar versus closely spaced bipolar ring electrodes.

Floating P wave sensing can be derived from bipolar atrial electrodes with different electrode configurations, although the relative clinical efficacy of these methods of atrial sensing has not been studied. We evaluated 32 sex and age matched patients with advanced AV block who received AV synchronous pacers using either a single lead with diagonally arranged bipole (Unity VDDR, Model 292, Intermedics Inc.) or closely spaced bipolar complete ring electrodes (Thera VDD, Model 8948, Medtronic Inc.). The total surface area of the atrial electrodes were 17.2 and 25 mm2, and the highest programmable atrial sensitivities were 0.1 and 0.25 mV, respectively. Atrial electrogram amplitude and sensing threshold were evaluated at implant and at each follow-up clinic visit (1, 3, and 6 months). Stability of atrial sensing was assessed during physical maneuvers, treadmill exercise test, and Holter recording. Atrial electrogram amplitude at implantation was higher in the Thera VVD (2.08 +/- 0.79 vs 1.45 +/- 0.59 mV in Unity VDDR; P < 0.05), but the value of atrial sensing threshold was lower during follow-up than Unity VDDR. P wave undersensing was additionally observed with both pacemakers during physical maneuvers and exercise testing (6%-19% of patients). Two and four patients had atrial undersensing on Holter in the Unity VDDR and Thera VDD, respectively, and the percentage P wave undersensing were 0.88% +/- 2.41% versus 3.63% +/- 8.16%, respectively. Reprogramming of the atrial sensitivity in the Unity VDDR and the use of investigational software allowing 0.18 mV atrial sensitivity to be programmed in the Thera VDD substantially reduced the percentage of P wave undersensing on Holter to 0.46% +/- 1.67% and 0.10% +/- 0.24%, respectively. Beginning at discharge with a programmed atrial sensitivity level at least twice the sensing margin, the mean atrial sensitivity level was reprogrammed from 0.29 to 0.26 mV for Unity VDDR and 0.33 to 0.24 mV for Thera VDD at 6 months. There was no incidence of atrial oversensing. Despite differences in atrial amplitudes at implantation between the diagonally arranged bipole and closely spaced full ring single lead systems, the clinical performances of atrial sensing were similar at an appropriately high atrial sensitivities. The absence of atrial oversensing suggests that single pass VDD pacemakers should probably be programmed at the highest available atrial sensitivity to ensure adequate P wave sensing as guided by physical maneuvers and Holter recording to minimize the need of subsequent reprogramming.

Aged↗

New integrated sensor pacemaker: comparison of rate responses between an integrated minute ventilation and activity sensor and single sensor modes during exercise and daily activities and nonphysiological interference.

A dual sensor DDDR pacemaker (DX2 Model 7970, Medtronic Inc.) has integrated the rate response of minute ventilation (MV) and activity (ACT) sensors. False rate acceleration by the ACT (constrained upper rate) and MV (cross-checked by ACT) is reduced. We examined the rate response profile and rate kinetics of the automatically optimized integrated sensor by comparing with the projected rate response of ACT and MV sensors alone in nine patients. After 1 month of sensor optimization using rate profile optimization (RPO), patients underwent maximal and submaximal treadmill exercises and performed activities of daily living (ADL). The integrated sensor mode gave a faster speed of rate response with a shorter delay time, time to 50% rate response and time to 90% of rate response compared to the MV sensor during hall walk (0.37 +/- 0.08, 0.7 +/- 0.09, 1.43 +/- 0.19 vs 1.11 +/- 0.1, 1.75 +/- 0.14, 2.91 +/- 0.17 min; P < 0.05). The average maximal sensor rates were significantly more proportional for the integrated sensor mode compared with either the ACT or MV mode. There was no significant difference in both the maximal pacing rate among the three sensor modes during maximal exercise and the rate decay during recovery. During interference studies by arm swinging (30-40 swings/min) and external tapping of the pacemakers (2 taps/s), there was only a moderate increase in pacing rate by 13 +/- 9, 16 +/- 5 beats/min. Hence, the new integrated sensor with the automatic rate profile optimization algorithm resulted in improved rate response profiles during submaximal exercise and ADL compared to the individual sensor response, and the sensor blending and cross-checking algorithm made the pacemaker relatively immune to false triggering of both the ACT and MV sensors.

Activities of Daily Living↗