Search PubMed⌕ Search

Biomedical subjects

S J Thomas

Publications and source records attributed to S J Thomas.

At least 19 recordsLinked to original sources

Human papillomavirus and head and neck cancer: a systematic review and meta-analysis.

It has been suggested that the link between human papillomavirus (HPV) and head and neck squamous cell carcinoma (HNSCC) is specific to carcinoma of the tonsil. We systematically reviewed studies that tested for HPV16 exposure in anatomically defined sites in the head and neck and a control group. The association between HPV16 and cancer was strongest for tonsil (OR: 15.1, 95% CI: 6.8-33.7), intermediate for oropharynx (OR: 4.3, 95% CI: 2.1-8.9) and weakest for oral (OR: 2.0, 95% CI: 1.2-3.4) and larynx (OR: 2.0, 95% CI: 1.0-4.2). To investigate heterogeneity, further stratification by method of HPV16 detection, suggested that variation in the magnitude of the HPV-cancer association with cancer site was restricted to studies using ELISA: among studies using PCR, the magnitude of the summary odds ratios was similar across the four sites. The association between HPV16 infection and HNSCC in specific sites suggests the strongest and most consistent association is with tonsil cancer, and the magnitude of this association is consistent with an infectious aetiology. However, the method of viral detection may be an important source of heterogeneity. Resolution of this issue will require further studies using both methods, examining associations separately in different sites.

Carcinoma, Squamous Cell↗

Margins between clinical target volume and planning target volume for electron beam therapy.

When growing a clinical target volume (CTV) to a planning target volume (PTV), it is necessary to determine suitable margins, based on the systematic and random uncertainties. For electron therapy, where treatments are usually given with single fields, the factors affecting the margin are very different in the direction of the incident beam from those in the perpendicular directions, since set-up errors do not affect the depth of the 90% isodose. For a typical case, the perpendicular margins are three times the margin in the direction of the incident beam. This gives rise to problems with volume growing algorithms if the beam axis is not aligned with a cardinal axis.

Algorithms↗

14-azacamptothecin: a potent water-soluble topoisomerase I poison.

On the basis of an analysis of luotonin A and its D-ring deaza analogue as topoisomerase I poisons and topoisomerase I-dependent cytotoxic agents, a novel analogue of the structurally related antitumor antibiotic camptothecin (CPT) was prepared. 14-Azacamptothecin was found to have much greater aqueous solubility than CPT, to inhibit topoisomerase I-mediated DNA relaxation more efficiently than CPT, and to stabilize the covalent binary complex to almost the same extent. 14-Aza CPT was found to be slightly less active than CPT in mediating cytotoxicity toward yeast expressing human topoisomerase I, possibly as a consequence of its greater off-rate from the CPT-topoisomerase I-DNA ternary complex.

Camptothecin↗

Palatability and glucose, insulin and satiety responses of chickpea flour and extruded chickpea flour bread eaten as part of a breakfast.

OBJECTIVE: To determine the effect of adding chickpea flour or extruded chickpea flour to white bread on palatability and postprandial glycaemia, insulinaemia and satiety. DESIGN: A randomised, single-blind, cross-over study of four 50 g available carbohydrate breakfasts. SETTING: School of Exercise and Nutrition Sciences, Deakin University. SUBJECTS: In all, 12 healthy subjects were recruited through posted notices. Totally, 11 (nine male, two female) completed the study (mean+/-s.e.m.; age 32+/-2 y; body mass index, 24.7+/-0.8 kg/m(2)). INTERVENTION: After overnight fasting, subjects consumed a control (white) bread (WB) breakfast twice, a chickpea bread (CHB) breakfast once and an extruded chickpea bread (EXB) breakfast once. Palatability and postprandial blood glucose, insulin and satiety responses were determined. Following this, food intakes from an ad libitum buffet and for the remainder of the day were assessed. RESULTS: A trend towards a lower incremental area under the curve (IAUC) of glucose for the CHB breakfast compared to the WB breakfast was observed (P=0.087). The IAUC of insulin and insulinaemic index (II) of the CHB breakfast were higher (P<0.05) than for the WB breakfast. No differences in glycaemic index (GI), satiety response, food intake or palatability were observed. CONCLUSIONS: CHB and EXB demonstrated acceptable palatability. CHB demonstrated some hypoglycaemic effect compared to WB, but neither CHB nor EXB demonstrated effects on satiety or food intake. The hyperinsulinaemic effect of CHB observed in this study requires further investigation.

Adult↗

Radiotherapy for glioma during pregnancy: fetal dose estimates, risk assessment and clinical management.

Cancer in pregnancy is relatively uncommon, but constitutes a major problem. We report the measurement of scatter dose to the fetus and the estimated fetal risk from that exposure in an illustrative case of a patient, 20 weeks pregnant, with a grade 3 anaplastic astrocytoma. A clinical decision was made to withhold radiotherapy, if possible, until after delivery. Sequential magnetic resonance imaging (MRI) showed no progression during the pregnancy. In the event, she was managed conservatively until the successful completion of her pregnancy. In case radiotherapy was required, an estimation of the fetal risk was made. Phantom measurements were undertaken to assess the likely fetal dose. Film badges were used to estimate the scattered radiation energy. Measurements were made on a Varian 600C at 6 MV and Asea Brown Boveri (ABB) accelerator at 8 and 16 MV. Doses were measured at 30, 45 and 60 cm from the isocentre; the fetus was assumed to lie at about 60 cm and not closer than 45 cm from the isocentre. Estimated doses to the position of the fetus were lowest with the 6 MV Varian accelerator. Using this machine without additional abdominal shielding, the estimated dose on the surface at 45 cm from the tumour volume was 2.2 cGy for a tumour dose of 54 Gy; using the ABB accelerator, the dose varied between 49-59 cGy. The energy of scattered radiation was in the range 208-688 keV, so that additional shielding would be practical to further reduce the fetal dose. The risk of cancer up to the age of 15 years attributable to radiation is 1 in 1700 per cGy, of which half will be fatal (i.e. 1 in 3300 per cGy). A dose of 2.2 cGy adds a risk of fatal cancer by the age 15 years of only 1 in 1500. Because the addition of shielding might halve the fetal dose, this risk should be reduced to 1 in 3000. For comparison, the overall UK risk of cancer up to the age 15 years is 1 in 650. In conclusion, careful choice of linear accelerator for the treatment of a pregnant woman and the use of additional shielding is valuable, as this can dramatically affect fetal dose.

Adult↗

Effectiveness of sodium hypochlorite in preventing inoculation of periapical tissues with contaminated patency files.

The aim of this study was to analyze the effectiveness of 5.25% sodium hypochlorite (NaOCI) in preventing inoculation of periapical tissues with contaminated patency files. Twenty-eight extracted human permanent teeth with single canals were used in the study. Group I teeth were filled with NaOCl, and #15 stainless steel files contaminated with Streptococcus sanguis (ATCC #10556) were allowed to pass through the NaOCI into the culture medium. The teeth in group II were also filled with NaOCl, but the contaminated files used in group II canals were immersed in NaOCl for 10 s prior to being placed into the canals and cultured. The negative control group used sterile files (0% growth), the first positive control group used contaminated patency files in teeth with empty canals (100% growth), and the second positive control group placed contaminated files into broth next to teeth filled with NaOCl (to evaluate potential chlorine leakage; 100% growth). The experimental results showed no positive growth of S. sanguis for groups I and II, indicating that the NaOCl present in the canal after irrigation was sufficient to kill the test organism.

Dental Alloys↗

Equivalent diameters of elliptical fields.

The equivalent field method is well established as a means of performing dose calculations in rectangular and irregular fields. There is, however, no consensus on the equivalent diameter (D) of elliptical fields, despite their common applications in kilovoltage radiotherapy. Measurements have been performed on 15 elliptical fields and 6 circular fields, comprising all possible combinations of 3 cm, 4 cm, 5 cm, 6 cm, 9 cm and 12 cm diameters, using 150 kV X-rays, with a half-value thickness of 8 mmAl. Equivalent diameters were calculated by a number of methods, including the equal area, ratio of perimeter to area, 2AB/(A+B) and sector integration. The best agreement with measurement was obtained using sector integration, which agreed with measurements within the limits of experimental error. The formula D=2AB/(A+B) was the best of the analytic formulae; at shallow depths it gave predictions of dose within better than 0.5%, whilst at 5 cm deep its greatest error was 1.6%. The equal area formula (D = square root AB) gave the worst predictions, with errors up to 5% at shallow depths, and 9% at a depth of 5 cm.

Humans↗

Capacity and demand models for radiotherapy treatment machines.

Models to predict the number of linear accelerators (linacs) required usually assume that capacity needs to equal demand. Queuing theory shows that capacity needs to exceed mean demand, to avoid the build-up of waiting times. A model has been developed, using Monte-Carlo modelling, to calculate the percentage of spare capacity required to keep waiting times to treatment short. For a matched pair of linacs, in a department that closes on bank holidays and compensates for category 1 patients by treating twice before or after the break, about 10% spare capacity is required to ensure that 86% of patients are able to start radiotherapy within a week of completing the treatment planning process. If a machine is booked as a single (unmatched machine), an additional 3% spare capacity is needed. If all bank holidays in the year are worked, then about 3% less is needed.

Algorithms↗

Aerotolerance of an endodontic pathogen.

The purpose of this study was to determine the length of time it takes to kill obligate anaerobic bacteria in a root canal exposed to room air or 3% hydrogen peroxide. Twenty-five extracted, human, permanent teeth with single canals were used. All teeth were contaminated with the anaerobe, Porphyromonas endodontalis (ATCC #35406), and were divided into five groups of five teeth each. Group I was exposed to 5 min of atmospheric air. Group II was exposed to 3% hydrogen peroxide for 5 min. Group III was exposed to 45 min of atmospheric air. Group IV was exposed to 3% hydrogen peroxide for 45 min. Group V, the control teeth, never left the anaerobic gas chamber. The results showed that atmospheric air exposure for up to 45 min is inadequate for eliminating P. endodontalis. The groups that were exposed to hydrogen peroxide showed no growth of bacteria.

Aerobiosis↗

Accuracy of a relocatable stereotactic radiotherapy head frame evaluated by use of a depth helmet.

In high precision radiotherapy, the more accurately the patient can be relocated, the smaller the clinical to planning target volume margin can be, with reduction in the volume of normal tissue irradiated. The Gill-Thomas-Cosman (GTC) relocatable stereotactic head frame provides immobilization of the patient which is highly reproducible. A depth helmet and measuring probe were used to confirm the accuracy of relocation of 31 patients treated in the GTC frame. The measurements were processed in a spreadsheet developed to calculate the size of the patient's displacement as a vector. Twenty-seven patients received fractionated stereotactically-guided conformal radiotherapy, and 4 single fraction stereotactic radiosurgery, amounting to 564 measurement episodes. The accuracy was extremely good, and considerably more accurate than standard thermoplastic head shells. Ninety-two percent of the displacement vectors were less than 2 mm, and 97% less than 2.5 mm. Considering each dimension separately, the largest mean displacement was 0.4 mm in the superior-inferior direction. Accuracy was constant through a fractionated course for most patients, but prediction based on measurements from the first few fractions was not reliable. Results were dependent on patient selection, with worse reproducibility in patients with neurological deficits, or difficulty cooperating. The depth helmet measurements detected a loosened mouth bite in one patient and allowed repositioning to be verified without the need for the simulator. Total treatment time, including use of the depth helmet to verify treatment position, is quicker (mean 15.7 min) than using portal films. The depth helmet, used in conjunction with the vector displacement spreadsheet, provides a simple way to define the CTV-PTV margin. For fractionated stereotactic radiotherapy we use a 3 mm CTV-PTV margin. This system could assist technology transfer to centres starting stereotactic radiotherapy using the GTC frame.

Brain Neoplasms↗

The effect of prolonged euglycemic hyperinsulinemia on lean body mass after severe burn.

BACKGROUND: The hypermetabolic response to burn increases protein catabolism. Euglycemic hyperinsu-linemia with exogenous insulin maintains muscle protein by continued stimulation of net protein synthesis. Our aim was to determine the effect of euglycemic hyperinsulinemia over the entire hospitalization on muscle anabolism by investigating lean body mass (LBM) as the primary endpoint. METHODS: Eighteen subjects between the ages of 2 and 18 with burns of more than 40% were prospectively randomized into 2 groups, a control (n = 9) and a treatment group (n = 9). The treatment group was given continuous intravenous insulin at a rate of at least 1.5 microU/kg/min to maintain serum glucose levels between 100 to 140 mg/dL. Treatment was instituted 24 to 48 hours after arrival and continued until the patient's injury was 95% healed. All patients received continuous enteral feeding. Patients underwent body composition studies by dual-energy x-ray absorptiometry (DEXA) scan on postoperative day 6 after initial burn excision and when 95% healed. RESULTS: Nutritional intakes were not different between groups. In the control, subjects continued catabolism resulted in peripheral muscle wasting and centripetal obesity with diminished truncal LBM. The treatment group had improvement in lean body mass (P =.004) and bone mass (P =.025). The treatment group also had less peripheral muscle wasting with overall increases in upper/lower extremity LBM (P =.005). Hospital length of stay in days per percent of total body surface area burned was decreased in the insulin group (control = 1.03 +/- 0.1 vs 0.7 +/- 0.9 for insulin patients; P <.05). CONCLUSIONS: Euglycemic hyperinsulinemia throughout the hospital course mitigates muscle catabolism and preserves lean body mass.

Adult↗

Absorbed dose behind eye shields during kilovoltage photon radiotherapy.

The absorbed dose at the position of the lens of the eye under lead or tungsten eye shields during kilovoltage photon radiotherapy is critically dependent not so much on the thickness of the eye shield itself as on the size of the treatment field and the diameter of the shield used. Whilst dose from primary photons is easily attenuated to relatively insignificant levels by a few millimetres of lead or tungsten, scattered photons from outside the shielded area can provide over 25% of the prescribed dose. Since backscatter factors do not increase monotonically with photon energy, it is not safe to assume that the highest photon energy used will provide the highest dose. A simple method to estimate the dose under an eye shield based on tabulated backscatter factors is shown. Measurements under commercially available eye shields were made to verify the expression and to determine the attenuation of primary photons. Predicted and measured absorbed dose under the eye shields were found to agree to within 1% of the prescribed dose. The relative dose due to primary photons beneath the eye shields was found to be less than 0.1% and 0.5 (+/-0.1)% for the 150 kV and 260 kV beams, respectively. This is considerably less than the dose from backscattered radiation.

Eye Protective Devices↗

Survival of a free flap after vascular disconnection at 9 days.

It is not known how long it takes for a radial forearm free flap to develop its own independent blood supply from its recipient bed. This article describes a case in which vascular disconnection of the pedicle happened at 9 days postoperatively and yet the graft survived via its own independent blood supply.

Adult↗

Analysis of gene expression during myc oncogene-induced lymphomagenesis in the bursa of Fabricius.

The transcriptional effects of deregulated myc gene overexpression are implicated in tumorigenesis in a spectrum of experimental and naturally occurring neoplasms. In follicles of the chicken bursa of Fabricius, myc induction of B-cell neoplasia requires a target cell population present during early bursal development and progresses through preneoplastic transformed follicles to metastatic lymphomas. We developed a chicken immune system cDNA microarray to analyze broad changes in gene expression that occur during normal embryonic B-cell development and during myc-induced neoplastic transformation in the bursa. The number of mRNAs showing at least 3-fold change was greater during myc-induced lymphomagenesis than during normal development, and hierarchical cluster analysis of expression patterns revealed that levels of several hundred mRNAs varied in concert with levels of myc overexpression. A set of 41 mRNAs were most consistently elevated in myc-overexpressing preneoplastic and neoplastic cells, most involved in processes thought to be subject to regulation by Myc. The mRNAs for another cluster of genes were overexpressed in neoplasia independent of myc expression level, including a small subset with the expression signature of embryonic bursal lymphocytes. Overexpression of myc, and some of the genes overexpressed with myc, may be important for generation of preneoplastic transformed follicles. However, expression profiles of late metastatic tumors showed a large variation in concert with myc expression levels, and some showed minimal myc overexpression. Therefore, high-level myc overexpression may be more important in the early induction of these lymphomas than in maintenance of late-stage metastases.

Animals↗

A tool to measure radiotherapy complexity and workload: derivation from the basic treatment equivalent (BTE) concept.

Radiotherapy workload is poorly represented by simple parameters of patients, fractions or fields treated because these do not contain any measure of treatment complexity. However, complexity is increasing and there is an urgent need to quantify this. We have evaluated the basic treatment equivalent (BTE) model as a measure of radiotherapy workload and complexity. Radiotherapy treatment times, from the patient entering to exiting the treatment room maze, were measured for 1298 treatment sessions on 269 patients. The data were used to assess the original model and derive three new models for predicting treatment duration. The most complicated, the 'Addenbrooke's complex model', contained two additional predictor variables, including 'site/technique', in a linear additive form. Before the study, the department used a standard treatment appointment time of 10 minutes. However, 50% of the measured treatments took longer than 10 minutes, (mean 10.9). Summed over the working day, this discrepancy indicates that a standard 10-minute appointment is a poor basis for scheduling radiotherapy. The original BTE model was effective in predicting treatment times, although this was improved by refinement of the model. The Addenbrooke's complex model correctly predicted 70% of treatment times to within 2 minutes (55% for the original BTE model), 80% to within 2.5 minutes and 95% to within 4.7 minutes. The percentage of the variation in observed times accounted for by the model is 59.4%. The models can represent radiotherapy complexity, can improve scheduling on linear accelerators, and are likely to be applicable to other departments. They are thus tools to assess the impact of changes in complexity from new techniques, trial protocols (e.g. the Medical Research Council prostate radiotherapy trial RTO1), and possible time saving from advanced technology such as multileaf collimators (MLCs) or automated machine set-up. The replacement of manually-lifted shielding blocks by MLCs should save 1.1-1.5 minutes for a three- or four-field pelvic plan (i.e. 12%-13%). The models could also be used to aid planning for future linear accelerator provision and for costing radiotherapy treatment.

Efficiency, Organizational↗

How much surplus capacity is required to maintain low waiting times?

Random fluctuations in demand make it impossible to see all patients in a very short time scale unless capacity exceeds the mean demand. We describe a model to estimate the capacity levels required as a function of mean demand. Random fluctuations were assumed to follow a Poisson distribution. A Monte Carlo analysis was used to model variations in length of waiting times. To see patients without a waiting list the capacity must exceed mean demand by an amount proportional to the square root of the mean; if capacity equals mean demand, then actual demand will exceed capacity almost half the time. The smaller the mean demand, the greater the percentage increase in capacity that is required. Thus, subdivision of numbers, for subspecialization or fast-tracking, demands greater overall capacity. When multiple serial steps are required, each step must have spare capacity if a waiting list is to be avoided. When capacity is only slightly greater than mean demand, random fluctuations mean that targets can be met for long stretches of time, but these are interspersed with periods when the waiting list rises substantially. Allowing a small waiting time (2-4 weeks) considerably reduces the excess capacity required. Targets such as the 2-week wait for cancer referrals can be achieved only if resource levels are set to give considerably more patient slots per week than mean demand. The level of spare capacity required depends on the level of demand and the maximum waiting time permitted. Without surplus capacity, waiting targets cannot be met. To meet the 2-week waiting target, capacity must exceed mean demand by two patient slots per week for 99% success, or by one slot per week for 90% success.

Efficiency, Organizational↗