Assessment of thermal tissue ablation with MR elastography.

An important part of thermal ablation therapy is the assessment of the spatial extent of tissue coagulation. In this work, the mechanical properties of thermally-ablated tissue were quantitatively evaluated using magnetic resonance elastography (MRE). This study shows that the mechanical properties of focused ultrasound ablated tissue are significantly different from normal tissue, and the difference can be imaged and measured using MRE. Repeated experiments revealed a reproducible pattern of tissue mechanical property change during thermal ablation in ex vivo bovine muscle. This pattern may reflect changes in intrinsic tissue structure and could be used to evaluate tissue coagulation during thermal ablation therapy. Magn Reson Med 45:80-87, 2001.

Animals↗

Effect of windowing and zero-filled reconstruction of MRI data on spatial resolution and acquisition strategy.

Standard, MR spin-warp sampling strategies acquire data on a rectangular k-space grid. That method samples data from the "corners" of k-space, i.e., data that lie in a region of k-space outside of an ellipse just inscribed in the rectangular boundary. Illustrative calculations demonstrate that the data in the corners of k-space contribute to the useful resolution only if an interpolation method such as a zero-filled reconstruction is used. The consequences of this finding on data acquisition and data windowing strategies are discussed. A further implication of this result is that the spatial resolution of images reconstructed with zero-filling (but without radial windowing) is expected to display angular dependence, even when the phase- and frequency-encoded resolutions are identical. This hypothesis is experimentally verified with a slit geometry phantom. It is also observed that images reconstructed without zero-filling do not display the angular dependence of spatial resolution predicted solely by the maximal k-space extent of the raw data. The implications of these results for 3D contrast-enhanced angiographic acquisitions with elliptical centric view ordering are explored with simulations.

Filtration↗

Steady-state preparation for spoiled gradient echo imaging.

While spoiled gradient echo sequences provide a rapid means of acquiring T(1)-weighted images, it is often desirable that the magnetization be in the steady state to avoid artifacts. For some applications, this requires many "dummy" repetitions of the pulse sequence prior to data collection, delaying image acquisition. A method is presented in which a saturation pulse, followed by a prescribed recovery period, places longitudinal magnetization levels of all materials near steady state, ready for data acquisition much sooner than when employing only dummy repetitions to achieve steady state. Effects of transverse coherences are studied using configuration theory. The method is shown to be effective in both phantom studies and in vivo applications, including real-time imaging, multiphase cardiac imaging, and triggered contrast-enhanced angiography. Magn Reson Med 45:653-661, 2001.

Humans↗

Dependence of venous enhancement on the field of view in 3D contrast-enhanced MRA using the elliptical centric view order.

The dependence of venous suppression on the acquisition field of view (FOV) in elliptical centric 3D contrast-enhanced magnetic resonance angiography (CE-MRA) is studied theoretically and experimentally. It is hypothesized that a reduced FOV in an arterial phase acquisition results in improved venous suppression. An expression is derived linking the k-space representation of a vein to venous return time and acquisition parameters. For a y x z FOV reduction from 24 cm x 7.2 cm to 18 cm x 3.6 cm, equivalent voxel size, and venous return times ranging from 0-7 s, the mean improvement in venous suppression ranged from 7.0% for the 19-mm-diameter vein to 32.1% in the 6-mm-diameter vein, assuming a step function-shaped venous enhancement profile. Decreased venous enhancement with reduced FOV is also observed for scans with equivalent acquisition times, although the degree of suppression is dependent on the shape of the venous enhancement curve.

Carotid Artery, Common↗

Embedded MR fluoroscopy: high temporal resolution real-time imaging during high spatial resolution 3D MRA acquisition.

A method termed "embedded fluoroscopy" for simultaneously acquiring a real-time sequence of 2D images during acquisition of a 3D image is presented. The 2D images are formed by periodically sampling the central phase encodes of the slab-select direction during the 3D acquisition. The tradeoffs in spatial and temporal resolution are quantified by two parameters: the "redundancy" (R), the fraction of the 3D acquisition sampled more than once; and the "effective temporal resolution" (T), the time between temporal updates of the central views. The method is applied to contrast-enhanced MR angiography (CE-MRA). The contrast bolus dynamics are portrayed in real time in the 2D image sequence while a high-resolution 3D image is being acquired. The capability of the 2D acquisition to measure contrast enhancement with only a 5% degradation of the spatial resolution of the 3D CE-MR angiogram is shown theoretically. The method is tested clinically in 15 CE-MRA patient studies of the carotid and renal arteries.

Feasibility Studies↗

Carotid artery: elliptic centric contrast-enhanced MR angiography compared with conventional angiography.

PURPOSE: To determine the accuracy of elliptic centric contrast material-enhanced magnetic resonance (MR) angiography by using conventional angiography as the reference standard. MATERIALS AND METHODS: Fifty patients were examined prospectively with contrast-enhanced MR angiography and conventional angiography. The two examinations were performed within 1 week of each other. Two patients underwent conventional angiography of only one carotid artery, which yielded 98 arteries for comparison. RESULTS: With conventional angiography as the reference standard and by using a 70% threshold for internal carotid arterial diameter stenosis, maximum intensity projection (MIP) images had a sensitivity of 93.3%, specificity of 85.1%, and accuracy of 87.6%, whereas reformatted transverse source images had a sensitivity of 83.3%, specificity of 97.0%, and accuracy of 92.8%. Interobserver variability for conventional angiograms was 0.97, for MIP images was 0.91, and for source images was 0.90. The contrast-enhanced MR angiographic technique had a sensitivity of 88.9% and specificity of 58.1% for the presence of irregularity and/or ulceration. All 50 examinations were triggered appropriately so that minimal or no venous signal intensity was depicted. CONCLUSION: Contrast-enhanced elliptic centric three-dimensional MR angiography offers high-spatial-resolution, venous-suppressed images of the carotid arteries that appear to be adequate to replace conventional angiography in most patients examined prior to carotid endarterectomy.

Aged↗

High-spatial-resolution contrast-enhanced MR angiography of the renal arteries: a prospective comparison with digital subtraction angiography.

PURPOSE: To evaluate a high-spatial-resolution three-dimensional (3D) contrast material-enhanced magnetic resonance (MR) angiographic technique for detecting proximal and distal renal arterial stenosis. MATERIALS AND METHODS: Twenty-five patients underwent high-spatial-resolution small-field-of-view (FOV) 3D contrast-enhanced MR angiography of the renal arteries, which was followed several minutes later by more standard, large-FOV 3D contrast-enhanced MR angiography that included the distal aorta and iliac arteries. For both acquisitions, MR fluoroscopic triggering and an elliptic centric view order were used. Two readers evaluated the MR angiograms for grade and hemodynamic significance of renal arterial stenosis, diagnostic quality, and presence of artifacts. MR imaging results for each patient were compared with those of digital subtraction angiograms. RESULTS: The high-spatial-resolution small-FOV technique provided high sensitivity (97%) and specificity (92%) for the detection of renal arterial stenosis, including all four distal stenoses encountered. The portrayal of the segmental renal arteries was adequate for diagnosis in 19 (76%) of 25 patients. In 12% of the patients, impaired depiction of the segmental arteries was linked to motion. CONCLUSION: The combined high-spatial-resolution small-FOV and large-FOV MR angiographic examination provides improved spatial resolution in the region of the renal arteries while maintaining coverage of the abdominal aorta and iliac arteries.

Aged↗

Contrast-enhanced magnetic resonance angiography of the cervical vessels: experience with 422 patients.

BACKGROUND AND PURPOSE: Contrast-enhanced magnetic resonance angiography (CEMRA) permits acquisition of high-spatial-resolution, venous-suppressed, 3D MR angiograms of the cervical carotid and vertebral arteries. In this study, an elliptic centric-view ordering with either MR fluoroscopic triggering or test bolus timing was used. The use of CEMRA of the cervical vessels has changed our clinical practice and is replacing conventional angiography for the evaluation of most carotid and vertebral artery diseases. METHODS: We retrospectively reviewed our experience with the use of CEMRA performed in 422 patients from January through December 1999. RESULTS: CEMRA was performed to evaluate transient ischemic attack and ischemic stroke in 239 patients, asymptomatic carotid bruit in 88 patients, and other neurological symptoms in 95 patients. Carotid endarterectomies were performed in 97 patients (103 procedures), and conventional angiography was performed in 12 of these patients. CEMRA was used to evaluate for the presence of an arterial dissection in 85 of the 239 patients with transient ischemic attack and ischemic stroke. Of this group, 32 patients had cervical arterial dissection, and pseudoaneurysm was detected in 11 of these patients. Compared with ultrasonography of the cervical vessels, CEMRA provided additional information in 43 of 422 patients and led to changes in the decision as to whether to perform carotid endarterectomy in 5 patients. CONCLUSIONS: Use of CEMRA permits noninvasive evaluation of patients suspected of having carotid or vertebral disease and avoids the potential complications of conventional angiography.

Adolescent↗

Autocorrection of three-dimensional time-of-flight MR angiography of the Circle of Willis.

OBJECTIVE: The purpose of this study was to investigate the efficacy of a retrospective adaptive motion correction technique known as autocorrection for reducing motion-induced artifacts in high-resolution three-dimensional time-of-flight MR angiography of the circle of Willis. MATERIALS AND METHODS: Ten consecutive volunteers were imaged with an unenhanced gradient-recalled echo three-dimensional time-of-flight MR angiography sequence of the circle of Willis. Each volunteer was asked to rotate approximately 2 degrees after completion of one third and one half of the acquisition in the axial, sagittal, and oblique planes (45 degrees to the axial and sagittal planes). A single static data set was also acquired for each volunteer. Unprocessed and autocorrected maximum-intensity-projection images were reviewed as blinded image pairs by six radiologists and were compared on a five-point image quality scale. RESULTS: Mean improvement in image quality after autocorrection was 1.4 (p < 0.0001), 1.1 (p < 0.0001), and 0.2 (p = 0.003) observer points (maximum value, 2.0), respectively, for examinations corrupted by motion in the axial, oblique, and sagittal planes. All three axes had statistically significant improvement in image quality compared with the uncorrected images. Changes in image quality after the application of the autocorrection algorithm to static angiogram data were not statistically significant (mean change in score = -0.13 points; p = 0.29). CONCLUSION: Autocorrection can reduce artifacts in motion-corrupted MR angiography of the circle of Willis without distorting motion-free examinations.

Artifacts↗

Image metric-based correction (autocorrection) of motion effects: analysis of image metrics.

Magnetic resonance (MR) imaging of the shoulder necessitates high spatial and contrast resolution resulting in long acquisition times, predisposing these images to degradation due to motion. Autocorrection is a new motion correction algorithm that attempts to deduce motion during imaging by calculating a metric that reflects image quality and searching for motion values that optimize this metric. The purpose of this work is to report on the evaluation of 24 metrics for use in autocorrection of MR images of the rotator cuff. Raw data from 164 clinical coronal rotator cuff exams acquired with interleaved navigator echoes were used. Four observers then scored the original and corrected images based on the presence of any motion-induced artifacts. Changes in metric values before and after navigator-based adaptive motion correction were correlated with changes in observer score using a least-squares linear regression model. Based on this analysis, the metric that exhibited the strongest relationship with observer ratings of MR shoulder images was the entropy of the one-dimensional gradient along the phase-encoding direction. We speculate (and show preliminary evidence) that this metric will be useful not only for autocorrection of shoulder MR images but also for autocorrection of other MR exams.

Algorithms↗

MR imaging of shear waves generated by focused ultrasound.

This study has shown that magnetic resonance elastography (MRE) can detect shear waves excited by focused ultrasound (FUS) in both gel phantoms and ex vivo muscle. Good agreement was shown between the shear modulus measured from MRE images generated using FUS and that using previously reported MRE techniques. The shear wave displacement amplitude at the FUS focus was studied and found to be proportional with both FUS ultrasonic pulse intensity and the FUS modulation pulse period over the range tested.

Animals↗

Prospective multiaxial motion correction for fMRI.

Corruption of the image time series due to interimage head motion limits the clinical utility of functional MRI. This paper presents a method for real-time prospective correction of rotation and translation in all six degrees of rigid body motion. By incorporating an orbital navigator (ONAV) echo for each of the sagittal, axial, and coronal planes into the fMRI pulse sequence, rotation and translation can be measured and the spatial orientation of the image acquisition sequence that follows can be corrected prospectively in as little as 160 msec. Testing of the method using a computerized motion phantom capable of performing complex multiaxial motion showed subdegree rotational and submillimeter translational accuracy over a range of +/-8 degrees and +/-8 mm of motion. In vivo images demonstrate correction of simultaneous through-plane and in-plane motion and improved detection of fMRI activation in the presence of head motion.

Artifacts↗

Rapid autocorrection using prescan navigator echoes.

Autocorrection is an adaptive motion correction algorithm that does not require an in vivo measurement of the motion record. A novel method for ensuring convergence of this algorithm when motion is severe is presented. A limited number of navigator echoes are acquired before the imaging sequence to obtain a "snapshot" of the object. Phase differences between the navigator and image k-space data are used as an estimate of motion-induced phase shifts in the image, followed by autocorrection. In phantom data a six-fold reduction in computation time compared to autocorrection alone was realized. These results indicate that this navigator/autocorrection combination may be useful for reducing motion artifacts and computation time for MR exams when motion along the image phase encoding axis is severe.

Algorithms↗

On the cause of increased aliasing in the slice-select direction in 3D contrast-enhanced magnetic resonance angiography.

The combination of short repetition times and large flip angles typically used in 3D contrast-enhanced magnetic resonance angiography (3D CE MRA) can significantly alter the expected shape of the slab profile for unenhanced tissues, which can cause increased aliasing in the slice select direction. In this work, this increased slice select aliasing is demonstrated and explained from both theoretical and experimental points of view. The effect is due to the Ernst angle of unenhanced background tissue occurring on the falling edges of the flip angle profile that has been set for the significantly reduced T(1) of contrast-enhanced blood. The deleterious aliasing effects are magnified substantially when the chosen volume is placed close to surface coil reception with the slice select direction perpendicular to the coil axis. Magn Reson Med 44:336-338, 2000.

Animals↗

Interactive fast spin-echo imaging.

It is shown that a spin-echo sequence may be used to acquire T(2)-weighted, high-resolution, high-SNR sections at quasi-real-time frame rates for interactive, diagnostic imaging. A single-shot fast spin-echo sequence was designed which employs driven equilibrium to realign transverse magnetization remaining at the final spin echo. Driven equilibrium is shown to improve T(2) contrast at a given TR, or conversely to reduce TR by approximately 1000 msec and thus increase temporal resolution while maintaining a given level of contrast. Wiener demodulation of k-space data prior to reconstruction is shown to reduce blurring caused by T(2)-decay while constraining noise often associated with other inverse filters. Images are continuously acquired, reconstructed, and displayed at rates of one image every one to two seconds, while section position and contrast may be altered interactively. The clinical utility of this method is demonstrated with applications to dynamic pelvic floor imaging and interactive obstetric imaging.

Computer Systems↗

Simultaneous image acquisition utilizing hybrid body and phased array receiver coils.

In clinical MR imaging the design and selection of receiver coil is an important step in ensuring the highest image quality. Often this choice is based on selecting a receiver coil characterized by high spatial uniformity such as the body and head volume receiver coils or a surface coil (or array of coils) that provide high signal-to-noise ratio (SNR). In the past, it has been difficult to accomplish both high SNR and spatial uniformity as both coil types achieve one of these characteristics at the expense of the other. The purpose of this study was to achieve both high SNR and spatial uniformity through the simultaneous acquisition of the MR signal using the body and a surface coil array. Results indicate that this hybrid system can provide uniformity and SNR values comparable to those achieved by the body and surface coil arrays, respectively.

Humans↗

Determination of appropriate RF blocking impedance for MRI surface coils and arrays.

Surface and phased array receiving coils in MRI typically require that RF excitation be accomplished using the body coil. This process requires that the receiving coils contain blocking circuitry to increase the overall circuit impedance during RF excitation and withstand the electromotive force induced by the applied electromagnetic field. The aim of this study was to determine the optimal impedance range required during RF excitation based on an assessment of image quality. The experimental results are fit by an exponential model and establish criteria that can be applied for general receiver coil design.

Biophysical Phenomena↗

Dual-echo breathhold T(2)-weighted fast spin echo MR imaging of liver lesions.

The purpose of this study was to develop a multi-shot dual-echo breathhold fast spin echo technique (DFSE) and compare it with conventional spin echo (T2SE) for T(2)-weighted MR imaging of liver lesions. The DFSE acquisition (EffTE1/EffTE2/TR = 66/143/2100 ms) imaged 5 sections per 17 s breathhold. T2SE imaging (TE1/TE2/TR = 60/120/2500 ms) required 16:55 (min:s) for 14 sections. Both techniques used a receive-only phased-array abdominal multicoil and provided 192 x 256 effective resolution. The results showed first and second echo relative DFSE/T2SE contrast values for 27 representative lesions (15 consecutive patients) were 1.08 +/- 0.05 and 1.16 +/- 0.09 (mean +/- STD mean), respectively. Corresponding CNR values were 1.12 +/- 0.09 and 0.97 +/- 0.12. Overall DFSE was comparable-to-superior to T2SE for lesion sizing and image artifact. DFSE lesion detection was inferior to T2SE's in several patient studies because of decreased conspicuity of lesions located near multicoil edges and because of poor breathhold-to-breathhold reproducibility and lack of breathholding. However both DFSE (and T2SE) provided lesion detection rated to be of diagnostic quality for all patient studies. In conclusion, we found that DFSE provides diagnostically useful dual-echo T(2)-weighted MR liver images in a greatly decreased acquisition time.

Adult↗