Search PubMed⌕ Search

Biomedical subjects

S J Hazelwood

Publications and source records attributed to S J Hazelwood.

6 recordsLinked to original sources

Osteonal effects on elastic modulus and fatigue life in equine bone.

We hypothesized that recently formed, incompletely mineralized, and thus, relatively deformable osteons in the equine third metacarpus enhance in vitro load-controlled fatigue life in two ways. Macroscopically, there is a compliance effect, because reduced tissue elastic modulus diminishes the stress required to reach a given strain. Microscopically, there is a cement line effect, in which new osteons and their cement lines more effectively serve as barriers to crack propagation. We studied 18 4 x 10 x 100 mm beams from the medial, lateral, and dorsal cortices of metacarpal bones from 6 thoroughbred racehorses. Following load-controlled fatigue testing to fracture in 4 point bending, a transverse, 100 microm thick, basic fuchsin-stained cross-section was taken from the load-bearing region. The number and diameter of all intact (and thus recently formed/compliant) secondary osteons in a 3.8 x 3.8 mm region in the center of the section were determined. The associated area fraction and cement line length of intact osteons were calculated, and the relationships between these variables, elastic modulus (E), and the logarithm of fatigue life (logN(F)) were analyzed. As expected, logN(F) was negatively correlated with E, which was in turn negatively correlated with intact osteon area fraction and density. (LogN(F))/E increased in proportion to intact osteon density and nonlinearly with cement line density (mm/mm(2)). These results support the hypothesis that remodeling extends load-controlled fatigue life both through the creation of osteonal barriers to microdamage propagation and modulus reduction.

Animals↗

Do microcracks decrease or increase fatigue resistance in cortical bone?

Fatigue of cortical bone produces microcracks; it has been hypothesized that these cracks are analogous to those occurring in engineered composite materials and constitute a similar mechanism for fatigue resistance. However, the numbers of these linear microcracks increase substantially with age, suggesting that they contribute to increased fracture incidence among the elderly. To test these opposing hypotheses, we fatigued 20 beams of femoral cortical bone from elderly men and women in load-controlled four point bending having initial strain ranges of 3000 or 5000 microstrain. Loading was stopped at fracture or 10(6) cycles, whichever occurred first, and microcrack density and length were measured in the loaded region and in a control region that was not loaded. We studied the dependence of fatigue life and induced microdamage on initial microdamage, cortical region, subject gender and age, and several other variables. When the effect of modulus variability was controlled, longer fatigue life was associated with higher rather than lower initial crack density, particularly in the medial cortex. The increase in crack density following fatigue loading was greater in specimens from older individuals and those initially having longer microcracks. Crack density increased as much in specimens fatigued short of the failure point as in those that fractured, and microcracks were, on average, shorter in specimens with greater numbers of resorption spaces, a measure of remodeling rate.

Adult↗

Osteon pullout in the equine third metacarpal bone: effects of ex vivo fatigue.

An important concept in bone mechanics is that osteons influence mechanical properties in several ways, including contributing to toughness and fatigue strength by debonding from the interstitial matrix so as to "bridge" developing cracks. Observations of "pulled out" osteons on fracture surfaces are thought to be indicative of such behavior. We tested the hypothesis that osteon pullout varies with mode of loading (fatigue vs. monotonic), cortical region, elastic modulus, and fatigue life. Mid-diaphseal beams from the dorsal, medial, and lateral regions of the equine third metacarpal bone were fractured in four point bending by monotonic loading to failure under deflection control, with or without 10(5) cycles of previous fatigue loading producing 5000 microstrain (15-20% of the expected failure strain) on the first cycle; or sinusoidal fatigue loading to failure, under load or deflection control, with the initial cycle producing 10,000 microstrain (30-40% of the expected failure strain). Using scanning electron microscopy, percent fracture surface area exhibiting osteon pullout (%OP.Ar) was measured. Monotonically loaded specimens and the compression side of fatigue fracture surfaces exhibited no osteon pullout. In load-controlled fatigue, pullout was present on the tension side of fracture surfaces, was regionally dependent (occurring to a greater amount dorsally), and was correlated negatively with elastic modulus and positively with fatigue life. Regional variation in %OP.Ar was also significant for the pooled (load and deflection controlled) fatigue specimens. %OP.Ar was nearly significantly greater in deflection controlled fatigue specimens than in load-controlled specimens (p=0.059). The data suggest that tensile fatigue loading of cortical bone eventually introduces damage that results in osteonal debonding and pullout, which is also associated with increased fatigue life via mechanisms that are not yet clear.

Animals↗

A mechanistic model for internal bone remodeling exhibits different dynamic responses in disuse and overload.

Bone is a dynamic tissue which, through the process of bone remodeling in the mature skeleton, renews itself during normal function and adapts to mechanical loads. It is, therefore, important to understand the effect of remodeling on the mechanical function of bone, as well as the effect of the inherent time lag in the remodeling process. In this study, we develop a constitutive model for bone remodeling which includes a number of relevant mechanical and biological processes and use this model to address differences in the remodeling behavior as a volume element of bone is placed in disuse or overload. The remodeling parameters exhibited damped oscillatory behavior as the element was placed in disuse, with the amplitude of the oscillations increasing as the severity of disuse increased. In overload situations, the remodeling parameters exhibited critically sensitive behavior for loads beyond a threshold value. These results bear some correspondence to experimental findings, suggesting that the model may be useful when examining the importance of transient responses for bone in disuse, and for investigating the role fatigue damage removal plays in preventing or causing stress fractures. In addition, the constitutive algorithm is currently being employed in finite element simulations of bone adaptation to predict important features of the internal structure of the normal femur, as well as to study bone diseases and their treatment.

Animals↗

Total knee replacement with interlocking stems: a preliminary report.

Revision total knee replacements or primary total knee replacements with large amounts of bone loss frequently require long-stemmed prostheses to stabilize the components. The hypothesis of the current study was that long-stemmed prostheses can be fixed with interlocking screws, provide a successful outcome, avoid extensive stress-shielding, and allow easy revision in the future. Ten patients with a minimum 2-year followup were studied. Outcomes were studied preoperatively and postoperatively using the Short Form-12 questionnaires, physical examinations, and radiographs. Complications were recorded. Ability to do activities of daily living, strenuous work, and sedentary work were recorded on a 10-point analog scale. Results indicated that 80% of stems well-fixed as shown on serial radiographs, functional outcome scores postoperatively improved significantly from preoperatively, pain was improved significantly, and positive bone remodeling without stress-shielding was seen in 80% of patients, but 20% had significant stress-shielding in the metaphysis. Complications included two periprosthetic fractures for which the patients did not require revision surgery, and one infection. Long-stemmed total knee components with interlocking fixation seem to be a reasonable alternative when large bone defects exist in the femur or tibia.

Adult↗

The relationship between basic multicellular unit activation and origination in cancellous bone.

Activation frequency is often used as a measure of basic multicellular unit (BMU) activity in cancellous bone. However, activation frequency expresses the rate of BMU appearance in a histologic slide and not the rate of origination, which is a more physiologic indicator of remodeling activity and is necessary for the development of BMU-level bone remodeling simulations. Using identical assumptions to those for calculating the activation frequency, it is shown that the origination frequency in cancellous bone is equal to the activation frequency divided by the total distance traveled by the BMU and its width.

Bone Development↗