Search PubMed⌕ Search

Biomedical subjects

S J Erickson

Publications and source records attributed to S J Erickson.

At least 73 records · Page 4Linked to original sources

Color Doppler flow imaging.

The performance requirements and operational parameters of a color Doppler system are outlined. The ability of an operator to recognize normal and abnormal variations in physiologic flow and artifacts caused by noise and aliasing is emphasized. The use of color Doppler flow imaging is described for the vessels of the neck and extremities, upper abdomen and abdominal transplants, obstetrics and gynecology, dialysis fistulas, and testicular and penile flow imaging.

Abdomen↗

MR imaging in fibromatosis: results in 26 patients with pathologic correlation.

Fibromatoses are a diverse group of soft-tissue lesions that have been inconsistently categorized and treated. The purpose of our study was to establish the range of appearances of fibromatoses on MR images and perform a pathologic correlation to explain the variable signal-intensity patterns. During a 3-year period, 26 patients with deep fibromatoses were examined with MR. The MR images were evaluated for signal-intensity characteristics, and findings were correlated retrospectively with the pathologic diagnoses. The results showed that the MR appearance of fibromatoses is similar to that of other soft-tissue lesions, and the signal intensities vary greatly from lesion to lesion and within lesions themselves. The fibromatoses were either hyperintense, isointense, hypointense, or of mixed signal intensity relative to adjacent skeletal muscle. The hypointense areas appear to be zones of hypocellularity and dense collagen deposition. Microscopically all of the lesions invaded adjacent structures, but the MR appearances of the margins varied and were judged to be well demarcated (n = 14), intermediate (n = 5), or poorly demarcated (n = 6). Our experience shows that fibromatoses have a variable MR appearance no different from that of other soft-tissue lesions, and this variability reflects the composition and cellularity of the lesions.

Adult↗

Color Doppler sonography in the evaluation of erectile dysfunction: patterns of temporal response to papaverine.

Most studies of duplex Doppler sonography for the assessment of erectile dysfunction involve determination of peak systolic velocities 5 min after intracavernosal injection of papaverine. The purpose of this study was to determine the effect of the timing of Doppler measurements of flow after papaverine injection for establishing the presence of arterial and venous abnormalities. Color Doppler sonography was performed in 75 patients for evaluation of vasculogenic impotence. After intracavernosal injection of 60 mg of papaverine, measurements of peak systolic and end-diastolic velocities were obtained in each cavernosal artery at 5-min intervals for a total of 30 min. A peak systolic velocity of less than 25 cm/sec was used as the threshold for arterial insufficiency. An end-diastolic velocity of greater than 5 cm/sec was used to predict venous incompetence. Scanning was performed for direct assessment of dorsal venous flow. Thirty patients were subsequently evaluated by cavernosometry and cavernosography. In most patients (76%), maximum response to papaverine was achieved within the first 5 min. In eight patients, significant increases in systolic velocity were seen only after 5 min. In 10 patients, significant changes in end-diastolic velocity between 5 and 30 min resulted in diagnostic reclassification. Data acquisition for 30 min significantly improved the sensitivity (95%) and specificity (83%) for the prediction of venous incompetence in patients with correlative cavernosography. Transient, early dorsal vein flow was noted in normal subjects. Persistent dorsal vein flow had an 80% sensitivity and 100% specificity for venous incompetence. Our results suggest that, when using color Doppler sonography, gathering data for 30 min may improve the prediction of vasculogenic impotence.

Adult↗

CT of acquired abnormalities of the spleen.

Imaging considerations and features when assessing acquired abnormalities of the spleen with CT are described. Indexes of normal size and the implications of splenomegaly are discussed, as well as the CT appearances and types of neoplasia, cysts, traumatic injuries, infarction, and inflammatory changes.

Abscess↗

Color Doppler sonographic imaging in the assessment of upper-extremity deep venous thrombosis.

Color Doppler flow imaging with linear-array transducers was performed in 130 extremities in 91 patients with suspected upper-extremity deep venous thrombosis. Thrombi were detected in 39 studies (30%). Eighty-four patients had either imaging examinations (22 studies comprising venography in 20 patients, CT in one, and MR imaging in one) or clinical follow-up (99 studies) for correlation. In studies with imaging correlation, the sensitivity of the Doppler studies was 78% and the specificity was 92%. There were two false-negative examinations in which the proximal subclavian vein either could not be imaged or the anatomy was distorted. There was one false-positive color Doppler diagnosis of deep venous thrombosis in a case of partial obstruction of the subclavian vein caused by extrinsic compression. There were no known additional errors in color Doppler imaging in patients who had clinical follow-up. Four cases of isolated superior vena cava or proximal innominate vein obstruction were missed by color Doppler imaging. Color Doppler flow imaging is an accurate, noninvasive method for the evaluation of upper-extremity deep venous thrombosis. Other imaging tests may be required when the color Doppler study is negative and central venous thrombosis is suspected.

Adolescent↗

Diagnosis of ectopic pregnancy: endovaginal vs transabdominal sonography.

During a 25-month period, 193 women with the clinical diagnosis of suspected ectopic pregnancy had transabdominal and endovaginal sonograms. Most had quantitative determinations of serum human chorionic gonadotropin (HCG). Endovaginal sonography was diagnostic of ectopic pregnancy in 23 (38%) of the 60 patients with surgically proved ectopic pregnancies: transabdominal sonography was diagnostic in 13 patients (22%). All 83 intrauterine pregnancies were identified with endovaginal sonography, compared with 34 identified with transabdominal sonography. Endovaginal sonography was somewhat more helpful in the diagnosis of missed abortion and blighted ovum. Eighty endovaginal sonograms were classified as indeterminate as compared with 141 transabdominal studies. This indeterminate group included patients with complete abortions, ectopic pregnancies without sonographic evidence of an extrauterine gestation, incomplete abortions, and patients with subsequent negative serum levels. As in prior reports, endovaginal sonography was superior to transabdominal sonography in the evaluation of suspected ectopic pregnancies. Overall, endovaginal sonography was diagnostic in 113 patients, whereas transabdominal sonography was diagnostic in 52 patients. The finding of an extrauterine fetal pole or embryo was diagnostic for an ectopic pregnancy. Pelvic fluid, the appearance of the endometrium, and a single positive serum HCG determination were not helpful in making the diagnosis of ectopic pregnancy.

Abdomen↗

MR imaging of the tarsal tunnel and related spaces: normal and abnormal findings with anatomic correlation.

The tarsal tunnel syndrome may be caused by extrinsic or intrinsic pressure on the posterior tibial nerve or its terminal branches. The specific symptoms depend on the extent of nerve involvement, and compression distal or proximal to the tarsal tunnel may result in variants of the syndrome. To define better the capability of MR imaging for evaluating this entity, we performed MR imaging on three normal subjects and correlated the images with cryomicrotome sections. Six patients with symptoms suggestive of tarsal tunnel syndrome also were studied with MR. In all normal subjects, MR images showed the flexor retinaculum and the structures passing deep to the retinaculum: the tibialis posterior tendon, flexor digitorum longus tendon, flexor hallucis longus tendon, and the posterior tibial neurovascular bundle. The medial calcaneal sensory branch(es) and the medial and lateral plantar nerves also were delineated. Mechanical causes of compression were shown in all six symptomatic patients. The pathologic entities included two neurilemomas, tenosynovitis involving all three tendons, a ganglion cyst arising from the flexor hallucis longus tendon sheath, posttraumatic fibrosis, and post-traumatic fibrosis with associated posttraumatic neuroma. The MR findings were confirmed surgically in five cases. MR imaging can accurately depict the contents of the tarsal tunnel and the courses of the terminal branches of the posterior tibial nerve. In our small series, MR imaging accurately showed the lesions responsible for tarsal tunnel syndrome.

Ankle↗

Radiologic imaging of splenic anomalies.

Knowledge of the anatomy, embryology, and congenital anomalies of the spleen is needed in order to avoid pitfalls in the interpretation of abdominal imaging studies such as CT and sonography. For this reason, this pictorial essay illustrates the anatomy, embryology, and radiologic images of congenital anomalies of the spleen.

Adult↗

Color Doppler evaluation of arterial stenoses and occlusions involving the neck and thoracic inlet.

Color Doppler flow imaging is a new technique providing simultaneous display of a gray-scale tissue and a color-flow vascular image. We demonstrate its ability to predict accurately occlusions of numerous vessels, including the internal carotid, external carotid, common carotid, subclavian and innominate arteries. Alterations in flow direction and changes in spectral wave form provide useful clues to the presence of these occlusions. The cases are correlated with angiographic findings and functional flow diagrams of the hemodynamic changes involved.

Arterial Occlusive Diseases↗

Thrombosis at venous insertion sites after inferior vena caval filter placement.

Color Doppler flow imaging or compression ultrasound (US) was used to prospectively determine frequency of thrombosis at 54 venous insertion sites (47 in common femoral veins, seven in right internal jugular veins) after percutaneous placement of Greenfield filters for interruption of the inferior vena cava. Fifty-one filters were successfully placed in 51 patients with a dilator set or a balloon angioplasty catheter. Nine focal thrombi were detected in the common femoral vein (19%) and one in the right internal jugular vein (14%). Use of dilators induced eight thrombi (24%), compared with two (10%) from balloon catheters. The left common femoral vein had a high frequency of thrombosis, regardless of dilation technique (five of nine). Of nine patients with acute common femoral vein thrombosis, four became symptomatic within 10 days after the procedure. Patients may remain asymptomatic or have delayed symptoms; thus, US is valuable for determining patients at risk of thrombosis of the common femoral vein.

Catheterization↗

Color Doppler flow imaging of the normal and abnormal orbit.

Twenty-six normal orbits (16 subjects) and seven patients with suspected orbital disease were studied with color Doppler flow imaging CDFI). Arterial structures consistently identified included the ophthalmic artery, central retinal artery, and posterior ciliary branches. The terminal lacrimal branch was seen in the majority of orbits (n = 19). Venous structures consistently seen included the central retinal vein and venae vorticosae; the superior ophthalmic vein was identified in the majority of normal orbits (n = 22). Response of the superior ophthalmic vein to the Valsalva maneuver was assessed in six of the normal subjects (12 orbits). Retrograde flow was typically seen during the maneuver and accentuated antegrade flow after cessation of the maneuver. Pathologic entities correctly diagnosed with CDFI included a dural arteriovenous malformation (AVM) with spontaneous carotid-cavernous fistula, an orbital AVM, and superior ophthalmic vein thrombosis. Vascular lesions were excluded in two patients with orbital masses. Bilaterally enlarged superior ophthalmic veins were identified in a patient with unilateral symptoms suggestive of a varix; CDFI results were confirmed with computed tomography, but orbital venograms were interpreted as normal. These findings suggest that CDFI may be helpful in the evaluation of suspected vascular orbital disease.

Adult↗

Stenosis of the internal carotid artery: assessment using color Doppler imaging compared with angiography.

The percentage of diameter stenosis of the internal carotid artery was estimated directly from color Doppler images obtained in both longitudinal and transverse planes and compared with the results of digital subtraction angiography in 49 patients (95 carotid arteries). Peak systolic velocity measurements were obtained by placing the sample volume in the highest-velocity flow stream with the angle-correction cursor parallel to the color-encoded lumen. Arterial stenoses were categorized on a grade 1-5 scale: 1 = 0-15%, 2 = 16-49%, 3 = 50-75%, 4 = 76-99%, and 5 = occlusion. Percent diameter stenosis could not be determined in 12 color Doppler flow imaging studies (13%) due to calcified plaque. Of the remaining 83 arteries evaluated by both techniques, the respective categories by color Doppler flow imaging/angiography were grade 1 (16/26), grade 2 (25/24), grade 3 (30/19), grade 4 (5/8), and grade 5 (7/6). Percent diameter stenosis determined by color Doppler flow imaging was greater than by angiography in 25% and less than by angiography in 4%. Peak systolic velocity measurements did not separate the hemodynamically insignificant (less than 50% diameter stenosis) grade 1 and grade 2 lesions, but were in agreement in 86% of grades 3-5 stenotic categories, as determined by measurements from the color Doppler flow image. A direct measurement of percent diameter stenosis from the color Doppler flow image was possible in 87% of cases. Peak systolic velocity provided correlative diagnostic information when assessing hemodynamically significant lesions.

Angiography↗

Renal imaging in long-term dialysis patients: a comparison of CT and sonography.

Patients undergoing long-term dialysis are subject to cyst formation, hemorrhage, and neoplasia in their native kidneys. Detection of these complications with incremental dynamic CT and detection with sonography were compared prospectively in 41 patients (79 kidneys) who had been undergoing dialysis intermittently for 3 or more years. Acquired cystic kidney disease (five or more cysts per kidney) was identified in 59% of kidneys by use of CT and in 18% by use of sonography. CT showed a complete renal contour definition in all cases, sonography did so in only 57%. Three solid renal tumors (2- to 4-cm diameter) were identified with both techniques with no false-negative evaluations. Four benign hemorrhagic cysts were identified with combined CT (hyperdense mass) and sonography (benign cysts). CT provided the best anatomic image quality and was more accurate for detection of acquired cystic kidney disease. CT and sonography were equivalent for detection of solid tumors. Our results suggest that dynamic contrast-enhanced CT scanning with the supplemental use of sonography is the best imaging regimen for the evaluation of suspected acquired cystic kidney disease and its potential complications.

Adolescent↗

Pseudoaneurysms complicating pancreatitis: detection by CT.

Complications of pancreatitis such as pseudocyst formation and abscess are well known to radiologists. Secondary formation of pseudoaneurysms has not been emphasized in the radiologic literature. The great morbidity and mortality associated with pseudoaneurysms emphasize the importance of early detection. Three patients are described whose angiographically proved pseudoaneurysms were demonstrated on contrast material-enhanced abdominal CT scans obtained for evaluation of pancreatitis. A homogeneously enhancing structure within or adjacent to a pancreatic pseudocyst or contiguous with a vascular structure should be considered highly suspicious for an associated pseudoaneurysm.

Aneurysm↗

Effects of halogenated organic compounds on photosynthesis in estuarine phytoplankton.

Chlorine oxidants (chlorine gas, sodium hypochlorite, and calcium hypochlorite) are used as biocides to control fouling in seawater cooled power generating plants and to kill pathogens in sewage effluents entering estuarine waters. Organisms killed include algae, fungi, bacteria, barnacles, oysters, and clams. Use of these chemicals in saline waters results in the formation of halogenated by-products (JOHANNESSON 1958, DUURSAM & PARSI 1976, DOVE 1973). BEAN et al, (1978), in a study of chlorinated seawater, identified eighteen organic compounds generated by chlorination. Due to rapid substitution of bromine for chlorine, brominated rather than chlorinated by-products are formed (FARKAS et al. 1949, GALAL-GORCHEV & MORRIS 1965, MACALADY et al. )977, SUGAM & HELZ 1977). The effects of these chlorinated by-products on estuarine phytoplankton are not known. Experiments in this study examined singly the effects of fifteen commercially available compounds on photosynthesis by estuarine phytoplankton.

Hydrocarbons, Halogenated↗