A simpler endotracheal tube guide.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to S J Barker.
Explore the source record for details and available documents.
BACKGROUND: Although the effects of propofol on cerebral metabolism have been studied in animals, these effects have yet to be directly examined in humans. Consequently, we used positron emission tomography (PET) to demonstrate in vivo the regional cerebral metabolic changes that occur in humans during propofol anesthesia. METHODS: Six volunteers each underwent two PET scans; one scan assessed awake-baseline metabolism, and the other assessed metabolism during anesthesia with a propofol infusion titrated to the point of unresponsiveness (mean rate +/- SD = 7.8 +/- 1.5 mg.kg-1.h-1). Scans were obtained using the 18fluorodeoxyglucose technique. RESULTS: Awake whole-brain glucose metabolic rates (GMR) averaged 29 +/- 8 mumoles.100 g-1.min-1 (mean +/- SD). Anesthetized whole-brain GMR averaged 13 +/- 4 mumoles.100 g-1.min-1 (paired t test, P < or = 0.007). GMR decreased in all measured areas during anesthesia. However, the decrease in GMR was not uniform. Cortical metabolism was depressed 58%, whereas subcortical metabolism was depressed 48% (P < or = 0.001). Marked differences within cortical regions also occurred. In the medial and subcortical regions, the largest percent decreases occurred in the left anterior cingulate and the inferior colliculus. CONCLUSION: Propofol produced a global metabolic depression on the human central nervous system. The metabolic pattern evident during anesthesia was reproducible and differed from that seen in the awake condition. These findings are consistent with those from previous animal studies and suggest PET may be useful for investigating the mechanisms of anesthesia in humans.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
We have employed a genetic approach to study the resistance of tomato to the phytopathogenic bacterium Pseudomonas syringae pv tomato. Resistance to P. s. tomato depends upon expression of the Pto locus in tomato, which encodes a protein with similarity to serine/threonine protein kinases and recognizes pathogen strains expressing the avirulence gene avrPto. Eleven tomato mutants were isolated with altered resistance to P. s. tomato strains expressing avrPto. We identified mutations both in the Pto resistance locus and in a new locus designated Prf (for Pseudomonas resistance and fenthion sensitivity). The genetic approach allowed us to dissect the roles of these loci in signal transduction in response to pathogen attack. Lines carrying mutations in the Pto locus vary 200-fold in the degree to which they are susceptible to P. s. tomato strains expressing avrPto. The pto mutants retain sensitivity to the organophosphate insecticide fenthion; this trait segregates with Pto in genetic crosses. This result suggested that contrary to previous hypotheses, the Pto locus controls pathogen recognition but not fenthion sensitivity. Interestingly, mutations in the prf locus result in both complete susceptibility to P. s. tomato and insensitivity to fenthion, suggesting that Prf plays a role in tomato signaling in response to both pathogen elicitors and fenthion. Because pto and prf mutations do not alter recognition of Xanthomonas campestris strains expressing avrBsP, an avirulence gene recognized by all tested tomato cultivars, Prf does not play a general role in disease resistance but possibly functions specifically in resistance against P. s. tomato. Genetic analysis of F2 populations from crosses of pto and prf homozygotes indicated that the Pto and Prf loci are tightly linked.
OBJECTIVE: We wished to determine whether the individual bias (mean difference) and precision (standard deviation of the difference) values of 2 variables, arterial oxygen saturation (SaO2) and mixed venous oxygen saturation (SvO2), could be used to predict the bias and precision values of the combined dual oximetry variable (SaO2-SvO2). METHODS: We simultaneously measured SaO2 by pulse oximetry and arterial blood gas co-oximetry and SvO2 by fiberoptic reflectance oximetry pulmonary artery catheter and venous blood gas co-oximetry in 238 data sets from 55 patients. Three different methods were used to predict the standard deviation of the difference of (SaO2-SvO2) [s delta(SaO2-SvO2)]: simple sum, root mean square (RMS) error, and RMS error with correction term. We derived the equation for the RMS error with correction term because initial results showed that the simple sum and RMS error methods did not predict s delta(SaO2-SvO2) well. The correction term accounts for the non-independence of simultaneous SaO2 and SvO2 measurements. RESULTS: The observed overall bias of the SaO2, SvO2, and (SaO2-SvO2) measurement methods were 0.17, -1.76, and 1.94, respectively. The observed overall s delta(SaO2-SvO2) of the (SaO2-SvO2) measurement method was 5.12. The simple sum method overestimated the actual s delta(SaO2-SvO2) by 38%, the RMS error method differed from the actual s delta(SaO2-SvO2) by 3%, and the RMS error with correction term method matched the actual s delta(SaO2-SvO2). CONCLUSION: The bias of a (SaO2-SvO2) measurement method is simply the bias of the SaO2 measurement method less the bias of the SvO2 measurement method. s delta(SaO2-SvO2) is best predicted by the derived equation, RMS error with correction term. The same principles and equations also apply to other situations in which 2 variables with the same dimensions are combined into 1 variable, such as (PaCO2-EtCO2) gradients and perfusion-pressure gradients. Although the difference between the s delta(SaO2-SvO2) predicted by the RMS error equation and the derived RMS error equation with correction term was small, the difference may be significant for other combined variables.
Anaesthetic residents used bag valve mask (BVM) or mouth mask (MM) ventilation, both with an O2 flow of 15 l min-1 to ventilate 30 ASA I or II anaesthetised patients for 4 min prior to endotracheal intubation. Mean nasopharyngeal O2 was higher with BVM (BVM 95% (S.D. 3%) MM 54% (S.D. 12%)). End tidal CO2 (ETCO2) was similar in both groups (ETCO2% at 4 min: BVM 4.65 (S.D. 0.84) MM 4.53 (S.D. 0.54)) but respiratory rate was faster with BVM (BVM 17 min-1 (S.D. 5) MM 12 min-1 (S.D. 4)). Peak (Paw) and mean (Paw) airway pressures were higher with MM and MM produced significant expiratory pressure [cmH2O: BVM Paw 16.7 (S.D. 5.3) Paw 4.2 (S.D. 2.1) MM: Paw 20.9 (S.D. 5.2) Paw 7.8 (S.D. 2.1)) minimum expiratory pressure: MM 2.4 (S.D. 1.1) BVM 0.2 (S.D. 0.4). Gastric insufflation was detected in two MM and two BVM patients. This tended to be more severe with MM ventilation. Although MM ventilation has some important disadvantages it can be used effectively by resuscitators with little or no experience in its use.
BACKGROUND: We describe the anesthetic management for a new surgical procedure: laser ablation of emphysematous bullae via thoracoscope. Although thoracoscopy is not new, this is the first description of a series of patients with bilateral, chronic lung disease who underwent long periods of one-lung ventilation (OLV) during thoracoscopic therapy. METHODS: Twenty-six laser ablation procedures were performed in 22 patients. The patients were elderly (mean age 63 yr) with a large incidence of coexisting cardiovascular disease. Most required chronic home oxygen therapy. Patients were monitored invasively, and hemodynamic data were recorded every 5 min. Arterial blood gas analyses were performed every 15 min. Comparisons were made between three intraoperative periods: two-lung ventilation (TLV) before thoracoscopy, OLV during thoracoscopy, and TLV after thoracoscopy. RESULTS: All patients survived the operation despite a mean OLV duration of 170 min, but several experienced serious intraoperative problems, such as hypoxemia or hypotension. Hypoxemia was treated with nondependent lung continuous positive airway pressure and dependent lung positive end-expiratory pressure. In all patients the lungs were adequately ventilated, but bronchopleural fistulae occurred upon return to TLV in every case. The resulting air leaks, often 50% of inspired tidal volume, required the use of a pressure-cycled ventilator to maintain oxygenation. Postoperative air leaks greater than 50% of inspired tidal volume usually required subsequent surgical correction, while smaller leaks resolved spontaneously. Mechanical ventilation was required for an average of 5 days. Eighty-four percent have survived at least 6 months, and nearly all survivors report symptomatic improvement. CONCLUSIONS: Ablation of bullae appears to provide symptomatic improvement, and thoracoscopy might be better tolerated than thoracotomy, especially in patients with severe bullous emphysema.
BACKGROUND: Previous studies have shown that pulse oximeters whose sensors are positioned improperly may yield erroneously low saturation (SpO2) values on normoxemic subjects. The behavior of oximeters with malpositioned sensors during hypoxemia has not been studied. The current study is aimed at determining the behavior of several different pulse oximeters over a wide range of arterial oxygen saturation (SaO2). METHODS: In each of 12 healthy volunteers, a radial artery cannula was inserted, and eight different pulse oximeters, five of which had malpositioned sensors, were applied. Subjects breathed controlled mixtures of nitrogen and oxygen to slowly vary their SaO2 from 100% to 70%. Arterial blood samples were analyzed and pulse oximeter data were recorded at five stable SaO2 values for each subject. RESULTS: The oximeters with malpositioned sensors vary greatly in their behavior, depending on both the actual SaO2 and the manufacturer and model. One oximeter underestimated saturation at all SaO2 values, while three others underestimated at high SaO2 and overestimated at low SaO2. Linear regression analysis shows a decrease in the slope of SpO2 versus SaO2 in most cases, indicating a loss of sensitivity to SaO2 changes. Between-subject variation in response curves was significant. CONCLUSIONS: The calibration curves of the pulse oximeters studied were changed greatly by sensor malpositioning. At low SaO2 values, these changes could cause the oximeter to indicate that a patient was only mildly hypoxemic when, in fact, hypoxemia was profound. It is recommended that sensor position be checked frequently and that inaccessible sensor locations be avoided whenever possible.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
To determine the effect of increasing supplementary oxygen flow during ventilation with the Laerdal pocket mask 24 subjects ventilated a modified recording mannikin for four 90 s periods using the mask with oxygen flows of 5 l, 10 l, 15 l and 20 l.min-1. Oxygen concentration increased and carbon dioxide concentration decreased with increasing oxygen flow. Tidal volume also increased with oxygen flow. The delivered oxygen concentrations were lower than previously reported at all four rates; however, mask function improved with increasing flow up to 20 l.
A new technique of thoracoscopic laser ablation of pulmonary bullae suitable for patients with multiple bullae and diffuse emphysema was developed and assessed in 22 patients. 20 of 22 patients survived. Pre-operative and postoperative functional evaluation is available for the 11 patients followed up for more than a month; at 1 to 3 months postoperatively there were increases in FVC (mean 2.0 litres pre-operatively to 2.7 litres postoperatively, p less than 0.001), in FEV1 (0.74 to 1.06 litres, p = 0.01), and in maximum exercise treadmill times (5.4 min to 8.0 min, p less than 0.01). Postoperative air leaks lasted a mean of 13 days and usually resolved spontaneously. Other complications were bleeding (1 patient) and unilateral acute lung injury (1 patient). These results suggest that selected patients with diffuse emphysema and pulmonary bullae may benefit from thoracoscopic carbon dioxide laser ablation.
Explore the source record for details and available documents.
The accuracy of pulse oximetry (for pulse hemoglobin oxygen saturation [SpO2]) and mixed venous oximetry (for mixed venous hemoglobin oxygen saturation [SvO2]) was assessed during progressive normovolemic anemia in dogs. Splenectomized mongrel dogs under general anesthesia were monitored with a three-wavelength pulmonary artery oximeter catheter (10 dogs) and a pulse oximeter (11 dogs). Data were collected while fractional inspired oxygen concentration (FIO2) was varied from 1.00 to 0.05 in seven steps. The dogs then underwent isovolemic hemodilution, and the FIO2 was again varied. This sequence continued until data no longer could be obtained. The accuracy of each device was assessed by determining the bias (the average difference between the continuous monitor oximeter and the bench oximeter) and the precision (the standard deviation of the difference). For the three-wavelength Oximetrix catheter (for hemoglobin oxygen saturation denoted here SoxO2), the overall bias (SoxO2 - SvO2) and precision were -0.7 +/- 8.6% for the 193 data points. The accuracy as assessed by bias and precision for SoxO2 was similar for hematocrits of 40-15%. (Bias +/- precision was 2.1 +/- 5.7% for hematocrits greater than 40%, and -1.1 +/- 7.5% for hematocrits of 15% to 19%). At hematocrits between 10 and 14%, the precision worsened to 12%, and for hematocrits less than 10% the bias +/- precision was -11.5 +/- 11.8%. The overall SpO2 accuracy was 0.2 +/- 7.6% for 178 points. The pulse oximeter's accuracy was similar, down to hematocrits of 10%. Below 10%, the bias and precision worsened to -5.4 +/- 18.8%.(ABSTRACT TRUNCATED AT 250 WORDS)
Transcutaneous oxygen tension (PtcO2) is often used to monitor neonates and infants in special care units and the operating room. The transcutaneous index (TCI = PtcO2/arterial oxygen tension [PaO2]) is known to depend both on age and on cardiac index but is assumed to be independent of other physiologic variables. In this study we have shown that TCI also depends upon arterial carbon dioxide tension (PaCO2). Five young pigs were anesthetized and paralyzed and their lungs mechanically ventilated while they were monitored with PtcO2 electrodes and serial arterial blood gas analyses. For a 45 degrees C PtcO2 sensor, the mean TCI during normocapnia was 0.78, whereas during hyperventilation (PaCO2 = 20 mmHg) the mean TCI was reduced 65%, to 0.27. The corresponding TCI values for a 43 degrees C sensor were 0.33 and 0.065, representing an 80% decrease in TCI during hyperventilation. Hypoventilation had little effect upon TCI as long as hypoxemia was avoided. Twelve awake adult volunteers with radial artery cannulas were monitored with PtcO2 sensors at several body sites and two sensor temperatures. For a 44 degrees C sensor on the chest, the mean TCI decreased from 0.77 at normocapnia to 0.60 at a PaCO2 of 17 mmHg, a 22% change. For the same sensor on the foot, TCI decreased from 0.63 to 0.32, a 49% change. For a 42 degrees C sensor under the same conditions, the corresponding TCI decreases were 51 and 64%. Six of the volunteers were also monitored with laser-Doppler skin blood flow probes located on the chest, hand, and foot.(ABSTRACT TRUNCATED AT 250 WORDS)
Miniaturized sensors based upon the principles of optical fluorescence can measure the pH, PCO2, and PO2 of liquid or gas media. A prototype of a three-component fiberoptic sensor has been developed for intraarterial application by CDI, 3M Health Care, Irvine, California. We report the first study of this continuous intraarterial monitor in patients undergoing surgical procedures under general anesthesia. Fourteen patients participated in the study. The fiberoptic sensor was calibrated before insertion and then passed through an existing 18-gauge radial artery cannula. Blood samples were drawn at frequent intervals through the same cannula for in vitro blood gas analysis. For each of the 87 arterial blood gas samples obtained, the in vitro values of pHa, PaCO2, and PaO2 were compared with simultaneous readings from the fiberoptic sensor. For pHa, the mean error (error = fiberoptic value minus in vitro value) or "bias" of the fiberoptic data was -0.032 and the standard deviation of error or "precision" was 0.042. For PaCO2, the bias was -3.8 mm Hg and the precision was 4.7 mm Hg. For PaO2, the bias was -9.0 mm Hg and the precision was 23.3 mm Hg. For PaO2 values less than 175 mm Hg, the bias was -8.5 mm Hg and the precision was 8.3 mm Hg. Expressed in terms of percentage errors, the bias +/- precision values were -11.5% +/- 13.3% for PaCO2, and -6.2% +/- 10.0% for PaO2. The duration of the surgical procedures ranged from 1.6 to 8 h with an average of 4.2 h.(ABSTRACT TRUNCATED AT 250 WORDS)