[Angiographic diagnosis of mitral valve prolapse: errors and limitations].

In order to assess the reliability of some recently proposed methods for angiographic diagnosis and quantification of mitral valve prolapse (MVP), the left ventricular silhouettes obtained by cineangiography in 48 patients with typical auscultatory and M-mode MVP findings were examined. The following methods were tested in 40 angiographic studies that were found to be of good technical quality: method of Farry et al. (1975), of Smith et al. (1978), of Engel et al. (1978), of Spindola-Franco et al. (1979). In 23 cases a two-dimensional echocardiographic study was also performed and Engel's angiographic criteria were utilized to quantify the MVP. The angiographic and echocardiographic data were correlated in 13 cases in which it was possible to obtain both good quality echocardiographic and adequate angiographic (end-systolic identification of the two mitral valve commissures) studies. The following conclusions can be drawn: a correct angiographic quantification of the extent of bulging requires both end-diastolic and end-systolic identification of both anterolateral and posteromedial commissures; in spite of the good quality of the angiographic studies a correct end-systolic identification of the two commissures is obtainable in less than 50% of cases, which obviously restricts considerably the applicability of any objective method; among the tested angiographic methods only the Engel's method (evaluation of the distance between the plane of the mitral valve and the most protruding point of the prolapsed leaflets) showed a satisfactory diagnostic sensitivity (75% in RAO projection, 89.5% LL projection, 100% utilizing both projections); angiography is not suitable for a quantitative classification of the MVP in mild, moderate and severe forms; such a possibility, on the contrary, seems to be offered by two-dimensional echocardiography provided that Engel's angiographic are adopted.

Adolescent↗

Two-dimensional echocardiographic evaluation of aneurysms of the descending thoracic aorta.

To determine the ability of two-dimensional echocardiography (2-D echo) to detect aneurysms and dissections of the descending thoracic aorta (DTA), we studied 15 patients, five with proved DTA dissections (group A) and 10 with proved aneurysms without dissection (group B), using 2-D echo in three recording positions: precordial, suprasternal and a modified apical. The DTA was visualized in 14 of 15 patients (93%); in each patient in group A, an intimal flap was recognized (in two patients only by the apical approach and in one patient by all approaches). The DTA was visualized in nine of 10 patients in group B; in each patient, the internal dimension of the DTA was enlarged (25-43 mm/m2). In one group B patient, aortic dissection was erroneously suspected because spurious echoes were present in the lumen; in another patient, 2-D echo failed to demonstrate a thrombotic stratification in the enlarged lumen. We conclude that 2-D echo using all available approaches appears to be a reliable technique for evaluating dissections and aneurysms of the DTA.

Adult↗

A digital network for long-distance echocardiographic image and data transmission in clinical trials: the CEDIM (Carnitina, Ecocardiografia Digitalizzata, Infarto Miocardico) study experience.

A special computer network has been specifically designed and realized to connect 36 Italian cardiological institutions to a central core laboratory. This network, which has been created to run the CEDIM Multicenter Trial (effects of L-carnitine on left ventricular function in patients with myocardial infarction assessed by digital echocardiography), enables automatic verification, via computer, 24 hours a day, of patient eligibility criteria, randomization, transmission, and filing of real-time left ventricular echocardiographic examinations. All the investigators participating in the CEDIM trial underwent several training courses as well as dummy run procedures to achieve optimal performance of all the operational procedures required for the network to function smoothly and correctly. This paper describes the aims of this special network, its technical characteristics, and the investigator training and dummy run procedures.

Clinical Trials as Topic↗

Detection of proximal stenosis of left coronary artery by digital transesophageal echocardiography: feasibility, sensitivity, and specificity.

To assess feasibility, sensitivity, and specificity of transesophageal echocardiography (TEE) in visualizing proximal left coronary artery segments (entire left main, proximal left anterior descending, and circumflex) and in identifying proximal coronary stenosis, 160 consecutive patients were studied. Each patient underwent TEE before coronary angiography; the echocardiographic images were digitized and reviewed in a continuous cineloop format. The entire proximal left coronary artery was adequately imaged in 111 patients (70%). A stenosis was considered to be present at TEE if hyperreflecting plaques narrowing the coronary lumen were observed. TEE observed the presence of a stenosis in 6 of 6, 50 of 63, and 13 of 24 patients with stenosis detected at angiography on the left main, left anterior descending, and circumflex, respectively, and 2 of 105, 5 of 48, and 14 of 87 patients without angiographically detectable coronary stenosis in corresponding coronary segments. Thus, sensitivity and specificity of TEE in identifying stenosis of the left main coronary artery, proximal left anterior descending artery, and proximal circumflex artery were 100% and 98%, 79% and 89%, 54% and 84%, respectively. In conclusion, TEE identification of the proximal left coronary artery is feasible in most patients. Accuracy in identifying significant proximal stenosis varies from segment to segment and is higher for the left main coronary artery.

Coronary Angiography↗