Search PubMed⌕ Search

Biomedical subjects

S Holme

Publications and source records attributed to S Holme.

At least 19 recordsLinked to original sources

The use of a bacteria detection system to evaluate bacterial contamination in PLT concentrates.

BACKGROUND: Random-donor PLTs (RDPs) are functional at 7 days. Nevertheless, since the mid-1980s, concern for bacterial contamination has caused the storage period to be reduced to 5 days. The ability of a bacteria detection system (BDS, Pall) to determine bacterial contamination and permit extension of the PLT shelf life to 7 days was assessed. STUDY DESIGN AND METHODS: Blood was collected into CP2D and leukoreduced RDPs were prepared. Upon arrival at the hospital, a 2- to 3-mL aliquot was removed from each RDP and introduced into the Pall BDS pouch with a sterile docking device. The pouch was incubated at 37 degrees C for 24 hours and then the oxygen content was measured to determine bacterial contamination. Additionally, the RDPs were pooled and an aliquot was removed for culture with standard manual techniques. CCIs were calculated 1 hour after infusion. RESULTS: A total of 12,062 individual RDPs were tested. The Pall BDS detected bacteria in 5 units. All of these were positive on repeat sampling. Propionibacterium acnes, coagulase-negative Staphylococcus, and Bacillus species were confirmed by manual technique in 3 units, one could not be identified, and one was negative. Aliquots from PLT pools were positive in 80 of 2201 pools when tested by manual methods. Of these, 79 were false-positives and 1 unit contained coagulase-negative Staphylococcus. The Pall BDS was easy to use and required less than 5 minutes for all manipulations. After 7 days of storage, the PLTs gave an average CCI of 16 x 10(11)+/- 3.39 x 10(11) 1 hour after transfusion (n = 9). CONCLUSIONS: The Pall BDS permits evaluation of RDPs for bacterial contamination. Culture-negative PLTs were successfully transfused in our institution up to and including 7 days after storage with good CCIs.

Bacillus↗

On-pump versus off-pump coronary artery bypass: independent risk factors and off-pump graft patency.

OBJECTIVE: Current knowledge on off-pump coronary artery bypass (OPCAB) generally stems from single surgeons' experience or from series where OPCABs constituted a minor fraction of coronary operations. The present center decided to venture as far into OPCAB as possible during 1999. The present series thus represents the average surgeon's experience. METHODS: During 1999, 533 patients underwent coronary artery bypass grafting using cardiopulmonary bypass (CPB) in 368 and OPCAB in 165 including the circumflex artery (CX) area in 91. Coronary arteriography was performed before discharge in the first 103 OPCAB patients. RESULTS: The CPB and OPCAB groups differed as regards left ventricular ejection fraction (53+/-13 versus 57+/-11, P < 0.0001) and frequency of triple-vessel or left main stem disease (84 versus 32%, P < 0.0001) but were comparable as regards diabetes (12%), prior myocardial infarct (57%), unstable angina (21%), and previous heart surgery (3%). Using multivariate analyses, 30-day mortality (1.3%), P-creatine kinase myocardial band (CKMB) > 80 microg/l (11.1%), re-sternotomy for bleeding (4.5%) or dehiscense (1.7%), transitory cerebral ischemia and stroke (1.7%), supraventricular tachycardia (27.4%), and hospital stay (mean 8 days) were unrelated to off- versus on-pump surgery as well as to OPCAB in triple-vessel disease. CX branches < or = 1mm, > or = 5 distal anastomoses, prior heart surgery, right coronary artery (RCA) branches < or = 1.5mm, 8-21 days old myocardial infarct, female gender, and preoperative acute arrhythmia (among others) were identified as independent risk factors for mortality or increased CKMB in all 533 patients. The latter five risk factors were reproduced in the OPCAB group isolated. The patency in the 103 OPCABs was 95.3, 91.8, and 85.3% in the left anterior descending artery (LAD), CX, and RCA, respectively. Patency was inversely related to diameter of the grafted vessel in the LAD and CX areas, unlike the RCA area. CONCLUSIONS: The results after beating heart surgery were good also in patients with triple-vessel disease, but specific gains relative to on-pump surgery could not be shown. The independent risk factors in the OPCAB group may indicate relative contraindications for OPCAB grafting.

Adult↗

In vivo and in vitro characteristics of double units of RBCs collected by apheresis with a single in-line WBC-reduction filter.

BACKGROUND: A novel apheresis procedure for a blood separator (MCS+, Haemonetics) enables the collection of 2 WBC-reduced RBC units in a single donation by using one disposable set with one in-line WBC-reduction filter (RC2H, Pall Corp.). The objective of this study was to evaluate the filtration performance in connection with different prefiltration RBC storage conditions and with the in vitro and in vivo storage quality of the filtered units. STUDY DESIGN AND METHODS: Sixty-six 2-unit RBC collection and gravity-filtration procedures were completed at three sites, resulting in 132 RBC units. Filtration of the double RBC units was performed at room temperature (RT) within 8 hours of collection (n = 36) and under refrigeration (1-6 degrees C) for up to 24 hours (n = 10) and 72 hours (n = 20) before filtration. RBC quality was compared to that of nonfiltered apheresis RBC units (n = 10). RESULTS: Median filtration time was 6.5 and 14 minutes for units stored at RT and under refrigeration, respectively. All 132 RBC units had residual WBC counts <0.4 x 10(6). The refrigerated units showed a greater mean log reduction in WBCs: 5.06 +/- 0.16 (24 hour) and 4.74 +/- 0.48 (72 hour), respectively, than did RT units: 4.47 +/- 0.28 (p<0.05). RBC loss was less than 12 percent in all cases (mean, 7.8 +/- 1.8%). Minimal differences in volume were observed between the paired RBC units. In vitro RBC storage characteristics of the filtered units were as expected and similar to those of the nonfiltered units. For RBC units held at RT (n = 24), the mean in vivo 24-hour recovery was 81.8 +/- 8.4 percent (double-label). CONCLUSION: Satisfactory filter performance in terms of WBC removal and RBC loss was observed with all 66 procedures, irrespective of storage conditions before filtration.

Blood Component Removal↗

Improved removal of white cells with minimal platelet loss by filtration of apheresis platelets during collection.

BACKGROUND: Filtration of apheresis platelets to remove white cells (WBCs) requires operator intervention after the collection procedure (postcollection filtration), which may cause variable and unsatisfactory filter performance (WBC removal and platelet loss). The MCS+ LN9000 apheresis system filters platelets through a WBC-reduction filter during each collection cycle (continuous filtration) at a flow rate of 15 to 25 mL per minute. Apheresis platelets obtained by continuous filtration were evaluated in terms of platelet loss, WBC removal, and platelet storage properties and then were compared to unfiltered apheresis platelets and to apheresis platelets that underwent postcollection filtration. Two WBC-reduction filters were tested (LRF6 and LRFXL). STUDY DESIGN AND METHODS: In 70 apheresis platelets, postcollection filtration was performed by using the LRF6 at flow rates of 80 mL per minute (n = 30) and 50 mL per minute (n = 30) and the LRFXL at 50 mL per minute (n = 10). One hundred fifty-eight apheresis platelets underwent continuous filtration through the LRF6 (n = 58) or the LRFXL (n = 100). Unfiltered apheresis platelets (controls) (n = 30) were obtained by the same collection protocol. RESULTS: Estimated platelet loss with continuous filtration was 7 percent for the LRFXL and 3 percent for the LRF6. A reduction in the filtration flow rate from 80 to 50 mL per minute with postcollection filtration through the LRF6 resulted in markedly lower WBC levels, with 10 percent versus 57 percent of the apheresis platelets having WBC counts <1 x 10(5), respectively. Additional improvements in WBC removal were found with continuous filtration; 85 percent of the apheresis platelets filtered with the LRF6 and 100 percent of the apheresis platelets filtered with the LRFXL had WBC counts <1 x 10(5). CONCLUSIONS: Continuous or postcollection filtration of freshly collected apheresis platelets resulted in minimal platelet loss. Better WBC removal from apheresis platelets was obtained with continuous filtration than with postcollection filtration, likely because of the slower flow rate. Platelet storage quality was not affected by filtration.

Blood Preservation↗

Viability and in vitro properties of AS-1 red cells after gamma irradiation.

BACKGROUND: Irradiation has been shown to adversely affect both in vivo 24-hour recovery (recovery [%]) and in vitro properties of stored red cells (RBCs). There is uncertainty as to how these changes are related to the day of irradiation and the length of storage after irradiation. STUDY DESIGN AND METHODS: Four protocols used day of irradiation and storage time after irradiation as the independent variables. At the conclusion of the storage period, viability was measured with radiolabeled RBCs as the recovery and the long-term survival time for RBCs that were circulating beyond 24 hours. In addition, in vitro values including RBC ATP, hemolysis level, and supernatant potassium were measured. Each subject donated 2 units of whole blood (CPD) and received autologous irradiated and untreated control RBCs (AS-1) on two separate occasions. RESULTS: Reduced recovery in irradiated units was noted when compared to that in control units, and the reduction was most apparent with long periods of storage after irradiation, irrespective of the day of irradiation. With irradiation on Day 1 of storage and a total storage period of 28 days, mean +/- SD recovery (single label) was 84.2 +/- 5.1 percent for control RBCs and 78.6 +/- 5.9 percent for irradiated RBCs (n = 16; p<0.01). With irradiation on Day 14 and storage through Day 42, the recoveries were 76.3 +/- 7.0 percent for control RBCs and 69.5 +/- 8.6 percent for irradiated RBCs (n = 16; p<0.01). Less reduction in recovery was observed with shortening of the postirradiation storage time. When the total storage period was reduced to 28 days after Day 14 irradiation, the recoveries were not significantly different. With an additional 2-day storage period after irradiation on Day 26, the recoveries were also comparable. Long-term survival times for control and irradiated RBCs were not significantly different in any of the four protocols. RBC ATP levels and hemolysis were minimally, but significantly influenced by irradiation. Supernatant potassium levels, however, were substantially increased after irradiation in each of the four protocols. CONCLUSION: Irradiation has only a small effect on the properties of RBCs treated and stored according to the utilized protocols. Longer storage times after irradiation resulted in progressively reduced recovery while long-term survival remained unaffected.

Blood Preservation↗

A multi-laboratory evaluation of in vitro platelet assays: the tests for extent of shape change and response to hypotonic shock. Biomedical Excellence for Safer Transfusion Working Party of the International Society of Blood Transfusion.

BACKGROUND: There is no consensus regarding the use of specific in vitro tests for the assessment of the quality of platelet components. A literature review found that the platelet discoid shape as measured photometrically by the extent of shape change (ESC) and hypotonic shock response (HSR) correlated well with in vivo viability. The purpose of this study was to determine whether multiple research laboratories can perform the ESC and HSR assays in an accurate, reproducible manner, with acceptable sensitivity and comparable results. STUDY DESIGN AND METHODS: Eleven laboratories conducted five identical experiments, each with a different unit of platelet-rich plasma (PRP). For each experiment, 2 half-units of PRP were prepared and stored overnight: 1 half-unit at 20 to 24 degrees C in CPD (CPD-PRP) and the other at 1 to 6 degrees C with 2 mg per mL of EDTA (cold EDTA-PRP) added to produce spherical platelets with reduced HSR. Platelet suspensions having different proportions of the two PRPs were prepared and evaluated in duplicate by ESC and HSR assays, and morphologically scored by microscopy. One-way ANOVA and Duncan multiple-range tests were performed to determine significant differences in assay results for suspensions having different proportions of CPD-PRP. RESULTS: Comparable ESC (mean range: 20-28% for CPD-PRP and 1-6% for cold EDTA-PRP) and HSR (mean range: 58-81% for CPD-PRP and 12-31% for cold EDTA-PRP) measurements were obtained by nine laboratories. Duplicate testing showed high reproducibility of ESR and HSR results /in all laboratories. A 25-percent difference in the proportion of CPD-PRP (indicative of a difference of approximately 25% in the proportions of discoid and spherical platelets) was detected with a sample size of five (p<0.05) for both the ESC and HSR assays. A high correlation was found for the ESC assay and morphology score (r = 0.93, n = 345). CONCLUSION: Multiple laboratories were able to obtain comparable results with the ESC and HSR tests. They were able to show that the tests can be performed in an accurate, reproducible manner and with acceptable sensitivity.

Blood Platelets↗

Storage and quality assessment of platelets.

Platelet concentrates stored for 5 days under currently optimal conditions at 22 C demonstrate approximately a 20-30% loss of viability as determined by CCI measurements in thrombocytopenic patients and radiolabeling studies with healthy volunteers. The functionality of platelets is substantially lost during storage. This loss appears, for most part, to be reversible upon infusion. In view of this, stored platelets should be acceptable for prophylactic treatment of thrombocytopenic patients in whom immediate hemostatic function is not critical. However, whether stored platelets are functionally adequate for immediate arrest of perioperative bleeding in surgical patients remain uncertain. Currently, a fully adequate and appropriate test that evaluates the hemostatic function of a stored platelet product is not available. In view of this, a desired goal in research and development of new platelet products may then be to attain a platelet product that is similar to fresh platelets in various haemostatic functions. Whether this is an obtainable or relevant goal remains to be seen.

Adult↗

Evaluation of in vivo and in vitro quality of apheresis-collected RBC stored for 42 days.

BACKGROUND AND OBJECTIVES: New technological developments make it possible to collect red blood cells (RBCs) by apheresis, which allows for better product consistency and has the potential for improved RBC quality. The purpose of these studies was to evaluate the quality and consistency of units of RBCs collected by apheresis using the MCS+(R) machine (Haemonetics Corp., Braintree, Mass., USA). MATERIALS AND METHODS: Two studies were performed. In study 1 (n = 10), using containers and CP2D/AS-3 solutions from Medsep Corp. (Covina, Calif. USA), one-unit apheresis RBCs were compared to manually collected RBCs in a random crossover design. In study 2 (n = 12), 6 subjects had one unit collected, while the remaining 6 subjects had two units of RBCs collected with comparison to previously manually collected RBCs from the same donors. Haemonetics containers and solutions were used in study 2. RESULTS: Low RBC volume variability was found for the apheresis collections with a standard deviation of only 6 ml difference between actual and target volumes. Combining the data from the two studies (n = 21 pairs), at 42 days of storage, the apheresis units showed slightly lower hemolysis (0.44+/-0.26 vs. 0.61+/-0.50%), lower supernatant potassium levels (50+/-3 vs. 53+/-3 mEq/l), and improved tolerance to osmotic shock (47+/-3 vs. 49+/-3%) as compared to manual units (p < 0.05). There was no statistically significant difference in RBC ATP (3.0+/-0.6 vs. 2.9+/-0.5 micromol/g Hb) or in 24-hour percent recoveries (81+/-6 for apheresis vs. 81+/-4% for apheresis red cells). Apheresis RBC quality was not affected by the manufacturer (Haemonetics vs. Medsep) of solutions and containers. CONCLUSIONS: RBC units collected by apheresis demonstrated low variability in volume of RBC mass collected, and showed similar RBC properties as compared to manually collected RBCs after processing and after 42 days of storage.

Adolescent↗

Cost effectiveness of day and inpatient psychiatric treatment: results of a randomised controlled trial.

OBJECTIVE: To compare direct and indirect costs of day and inpatient treatment of acute psychiatric illness. DESIGN: Randomised controlled trial with outcome and costs assessed over 12 months after the date of admission. SETTING: Teaching hospital in an inner city area. SUBJECTS: 179 patients with acute psychiatric illness referred for admission who were suitable for random allocation to day hospital or inpatient treatment. 77 (43%) patients had schizophrenia. INTERVENTIONS: Routine inpatient or day hospital treatment. MAIN OUTCOME MEASURES: Direct and indirect costs over 12 months, clinical symptoms, social functioning, and burden on relatives over the follow up period. RESULTS: Clinical and social outcomes were similar at 12 months, except that inpatients improved significantly faster than day patients and burden on relatives was significantly less in the day hospital group at one year. Median direct costs to the hospital were 1923 pounds (95% confidence interval 750 pounds to 3174 pounds) per patient less for day hospital treatment than inpatient treatment. Indirect costs were greater for day patients; when these were included, overall day hospital treatment was 2165 pounds cheaper than inpatient treatment (95% confidence interval of median difference 737 pounds to 3593 pounds). Including costs to informants when appropriate meant that day hospital treatment was 1994 pounds per patient cheaper (95% confidence interval 600 pounds to 3543 pounds). CONCLUSIONS: Day patient treatment is cheaper for the 30-40% of potential admissions that can be treated in this way. Carers of day hospital patients may bear additional costs. Carers of all patients with acute psychiatric illness are often themselves severely distressed at the time of admission, but day hospital treatment leads to less burden on carers in the long term.

Adolescent↗

Studies on platelets exposed to or stored at temperatures below 20 degrees C or above 24 degrees C.

BACKGROUND: Platelet concentrates (PCs) may be subjected to temperatures outside 20 to 22 degrees C during shipping or storage, which may have an adverse effect on platelet quality. STUDY DESIGN AND METHODS: These studies systematically evaluated the effect of short-term exposure (< or = 24 hours) of platelets to temperatures above 22 degrees or below 20 degrees C as part of standard 5-day PC storage at 22 degrees C, as well as the effect of long-term storage (5 days) at 24 and 26 degrees C. For the short-term exposure studies, up to 6 units of Day 1 standard PCs were mixed, split, and returned to the containers. Test units were then stored without agitation in an incubator at a specific temperature (4, 12, 16, or 18 degrees C) for various times up to 24 hours, after which they were stored with agitation at 22 degrees C. One unit acted as control and was stored at 20 to 22 degrees C throughout the 5-day storage period. Loss of platelet discoid shape was determined photometrically by the extent of shape change assay, by an increase in apparent platelet size by morphologic evaluation, and by swirling. RESULTS: A gradual loss of platelet discoid shape occurred at temperatures below 20 degrees C. For similar periods, a greater difference between test and control PCs was observed in units held at 4 degrees C than in those held at 16 degrees C. The data were fitted to an equation to relate platelet discoid shape (% of control) to exposure temperature and time. Assuming that a 20-percent decrease or more in the extent of shape change assay represents a significant loss in platelet viability, the equation predicts that such a loss occurs when the platelets are exposed to 16 degrees C for > or = 16 hours, to 12 degrees C for > or = 10 hours, or to 4 degrees C for > or = 6 hours, whereas exposure to 18 degrees C for < or = 24 hours has no significant effect. Storage for 5 days at temperatures < or = 26 degrees C was not associated with any significant reduction in platelet discoid shape or other measures of platelet quality. CONCLUSION: There was a gradual loss of platelet discoid shape at exposure temperatures < 20 degrees C, which worsened as temperatures decreased and exposure times increased to 24 hours. This relationship can be described in an equation that could be used as a guideline for allowable exposure conditions.

Blood Platelets↗

The expression of p-selectin during collection, processing, and storage of platelet concentrates: relationship to loss of in vivo viability.

BACKGROUND: Recent studies suggested that platelet activation with surface expression of p-selectin on stored platelets may be related to a loss of viability. At present, there has been no thorough investigation of the extent or significance of p-selectin expression during the collection, processing, and storage of platelet concentrates (PCs) under various conditions. STUDY DESIGN AND METHODS: Platelet surface expression of p-selectin (CD62) was determined on fixed platelet samples using fluorescein-conjugated monoclonal antibodies. Platelet viability was assessed by autologous transfusion of platelets stored for 5 days and labeled with either 51Cr or 111in. RESULTS: Little (2-10%) platelet expression of p-selectin was found in whole blood and platelet-rich-plasma preparations, whereas PCs showed a substantial increase in p-selectin expression to levels of 20 to 30 percent. Both fresh PCs and those stored for 5 days, obtained with one cell separator (MCS, Haemonetics) showed substantially lower levels of p-selectin expression than PCs from two other cell separators (Spectra, COBE, and CS-3000 with TNX-6, Baxter Healthcare). Exposure of platelets to EDTA, cold, or a pH below 6.2, conditions that are known to result in the loss of viability upon transfusion, produced substantial and irreversible p-selectin expression. PCs with a pH of 6.2 to 6.8 (conditions in which no loss of viability has been demonstrated) also showed pronounced p-selectin expression, which returned to control values after incubation at 37 degrees C in plasma at pH 7.0 to 7.2. With storage under current conditions the in vivo studies (n = 61) demonstrated a rather poor correlation between p-selectin expression and the percentage of recovery (r = -0.25) but a somewhat better correlation with survival (r = -0.42). Better correlations were observed with the extent of shape change, lactate, and hypotonic shock response. CONCLUSION: These studies show that p-selectin expression on the platelet surface is a predictor of platelet viability, although the extent of shape change and the hypotonic shock response may be more sensitive.

Blood Platelets↗

Addition of L-carnitine to additive solution-suspended red cells stored at 4 degrees C reduces in vitro hemolysis and improves in vivo viability.

BACKGROUND: The role of L-carnitine (LC) as the requisite carrier of long-chain fatty acids into mitochondria is well established. Human red cells (RBCs), which lack mitochondria, possess a substantial amount of LC and its esters. In addition, carnitine palmitoyl transferase, an enzyme that catalyzes the reversible transfer of the acyl moiety from acyl-coenzyme A to LC is found in RBCs. It has recently been shown that LC and carnitine palmitoyl transferase play a major role in modulating the pathway for the turnover of membrane phospholipid fatty acids in intact human RBCs, and that LC improved the membrane stability of RBCs subjected to high shear stress. RBC membrane lesions occur during storage at 4 degrees C; this study investigated whether the addition of LC (5 mM) to a standard RBC preservative solution (AS-3) affected cellular integrity with 42 days' storage. STUDY DESIGN AND METHODS: A paired (n = 10) crossover design was used for RBCs stored in AS-3 with and without LC. Both in vitro RBC properties reflective of metabolic and membrane integrity and in vivo measures of cell viability (24-hour percentage of recovery and circulating lifespan) were measured at the end of the storage. In addition, the turnover of membrane phospholipid and long-chain acylcarnitine fatty acids and the carnitine content of control and LC-stored RBCs were measured. RESULTS: It was shown that LC was irreversibly taken up by RBCs during storage, with a fourfold increase at 42 days. Furthermore, as found by the use of radiolabeled palmitate, the stored RBCs were capable of generating long-chain acylcarnitine. The uptake of LC during storage was associated with less hemolysis and higher RBC ATP levels and by a significantly greater in vivo viability for LC-stored RBCs than for control-stored RBCs: a mean 24-hour percentage of recovery of 83.9 +/- 5.0 vs. 80.1 +/- 6.0 percent and a mean lifespan of 96 +/- 11 vs. 86 +/- 14 days, respectively (p < 0.05). CONCLUSION: A beneficial effect of the addition of LC to RBCs stored at 4 degrees C was evident. This effect may be related to both biophysical and metabolic actions on the cell membrane.

Adenine↗

Aurin tricarboxylic acid inhibits adhesion of platelets to subendothelium.

Aurin-tricarboxylic acid (ATA) is a polycarboxylated compound which binds to high molecular weight multimers of von Willebrand factor (vWf), effectively preventing binding of vWf to platelet membrane GPIb. By this mechanism, ATA inhibits shear-induced platelet aggregation as well as ristocetin-induced platelet aggregation/agglutination, both of which require interaction of platelets and vWf. Although it is reasonable to assume that ATA might also interfere with platelet adhesion, the effects of ATA on this aspect of platelet function have not been described. We report effects of ATA on adhesion of freshly prepared radiolabeled platelets to subendothelium of everted rabbit aorta utilizing a model which permits observations at varying shear rates. Using concentrations of ATA that inhibited aggregation induced by either ristocetin or the more potent agonist, thrombin, ATA was found to inhibit adhesion of platelets in a dose-dependent manner. In addition, ATA was found to inhibit platelet aggregation in response to the agonists ristocetin or thrombin. The inhibitory effect of ATA on thrombin-induced aggregation was completely erased by washing and resuspension in a thrombin-free medium, indicating that ATA does not have any lasting effects on the platelet response to thrombin. In plasma coagulation tests, using either the prothrombin time, activated partial thromboplastin time of thrombin time, ATA prolonged clotting times in a dose-dependent manner.

Animals↗

Pseudothrombocytopenia in plateletpheresis donors.

BACKGROUND: EDTA pseudothrombocytopenia (PTCP) is an in vitro artifact in which the anticoagulation of blood with EDTA is associated with in vitro agglutination of platelets, resulting in a spuriously low platelet count. In apheresis donors, whole-blood samples for complete blood counts are routinely drawn into tubes anti-coagulated with EDTA. STUDY DESIGN AND METHODS: Records of apheresis donors were examined to identify persons in whom the postdonation counts were less than 100 x 10(9) per L. Identified donors were studied to confirm the presence of PTCP by drawing blood samples into EDTA, heparin, and trisodium citrate for serial platelet counts at room-temperature incubation. Platelet counts in citrated plasma were measured before and after the addition of EDTA. A single HLA-matched component from an identified PTCP donor was monitored for response by corrected count increment in the recipient. RESULTS: A total of nine donations were identified, involving 2 donors from a population of 945 donors (prevalence 0.2%). On testing, both donors were confirmed to have PTCP. The addition of EDTA to citrated plasma did not affect the platelet count. Response in a recipient to an HLA-matched component showed an acceptable corrected count increment. CONCLUSION: PTCP may occur in plateletpheresis donors and result in needless medical referral or donor deferral. PTCP does not appear to alter the yield content of the component or to be passively transferred to a recipient.

Blood Donors↗

At(a-) phenotype: description of a family and reduced survival of At(a+) red cells in a proposita with anti-Ata.

BACKGROUND: There is a paucity of data on the August (At) blood group antigen and clinical significance of anti-Ata. STUDY DESIGN AND METHODS: A proposita with the At(a-) phenotype was identified by the finding of anti-Ata in the cord blood eluate of her fifth live infant. Family members were studied, and a small aliquot of 51Cr-labeled At(a+) red cells was transfused to determine survival. RESULTS: There was no evidence of hemolytic disease of the newborn, as determined by the normal hemoglobin and bilirubin and normal clinical conditions. Six of seven siblings were tested, and two At(a-) female siblings were identified. In contrast to the proposita, neither sister had detectable anti-Ata in her serum, although each has had only one pregnancy. A monocyte monolayer assay performed on serum from the proposita gave a result of 20-percent hemolysis (normal, <3%), which is consistent with a clinically significant antibody. Transfusion of a small volume of allogeneic red cells that were phenotypically matched with the proposita, except for Ata, resulted in a 1-hour survival of 95 percent, but a 24-hour survival of only 18 percent, of the transfused cells. The survival pattern was exponential, which is characteristic of a non-complement-binding IgG antibody. CONCLUSION: Despite the absence of hemolytic disease of the newborn, this example of anti-Ata would appear to be a clinically significant antibody for the purposes of transfusion practice. Therefore, approaches to the management of clinical situations in which transfusion is required or likely should focus on the availability of autologous cells or frozen allogeneic At(a-) red cells.

Black People↗

In vitro and in vivo effects of prestorage filtration of apheresis platelets.

BACKGROUND: The effect of prestorage filtration on the quality of apheresis platelet concentrates stored for transfusion is undetermined. STUDY DESIGN AND METHODS: Investigation of 11 plateletpheresis components used a concurrent paired-study design. On the day of collection, each component was equally divided into two suspensions; one half was filtered, and the other half was not. Each suspension was stored for 5 days. In vitro testing was performed on the day of collection (Day 0) for cell counts and on Day 5 for measurements of lactate, glucose, blood gases, pH, platelet ATP, hypotonic stress ratio, extent of shape change in response to ADP, tissue necrosis factor alpha, interleukin 8, interleukin 1 alpha, interleukin 1 beta, interleukin 6, and platelet surface glycoproteins by flow cytometry. At the end of the 5-day period, a sample was taken from each of the two suspensions, radiolabeled with either 51Cr or 111In, and transfused concurrently. Posttransfusion samples were drawn for measurements of recovery and platelet survival and for functional assessment of the ex vivo ability of the circulating radiolabeled platelets to aggregate in response to ADP. RESULTS: The apheresis component had a mean platelet yield of 3.2 +/- 0.4 x 10(11) and a white cell yield ranging from 1 x 10(5) to 1 x 10(8), with a median of 2 x 10(7). Filtration resulted in a platelet loss of approximately 10 percent and a variable 2 to 3 log10 reduction in white cell content. No significant differences between filtered and unfiltered suspensions in paired t tests that would likely have an impact on platelet quality were observed in the in vitro tests. The in vivo recovery and survival were highly similar and not statistically different in filtered and unfiltered paired suspensions: the mean difference was 1.2 +/- 4.0 percent for recovery and 7.0 +/- 15 hours for survival. The functional assessment by aggregation to ADP showed no difference between filtered and unfiltered suspensions. A small decrease in tumor necrosis factor alpha and interleukin 8 was evident in the filtered suspension as compared to levels in the unfiltered suspensions. CONCLUSION: Prestorage white cell reduction in apheresis components resulted in WBC reduction by several log10 with no evident adverse effect on platelet viability or function.

Blood Platelets↗

White cell-reduced platelet concentrates prepared by in-line filtration of platelet-rich plasma.

BACKGROUND: The importance of white cell (WBC) reduction in platelet concentrates (PCs) for component quality is undetermined. STUDY DESIGN AND METHODS: Eleven paired components, each derived from one of two whole-blood units given by a single donor on the same day, were studied. One PC was WBC reduced by filtration with an in-line, integral, prototype filter, and the other was produced from unfiltered platelet-rich plasma (PRP) by a standard method. In vitro tests performed on Day 1 and Day 5 were blood gases, plasma lactate, glucose, platelet ATP, mean platelet volume, morphology score, hypotonic stress ratio, extent of shape change in response to ADP, and beta-thromboglobulin. After 5 days of storage, each component pair was labeled with 51Cr or 111In and transfused for the estimation of percent recovery and survival. RESULTS: PCs using the in-line, prototypic filter had a platelet loss of approximately 15 percent and a variable 1 to 3 log10 reduction (average, 95%) in WBC content. The variation in filter WBC removal was related to PRP WBC content and indicated that the filter did not have the capacity for a 3 to 4 log10 removal when PRP WBC content exceeded 1 x 10(8). The in vitro and in vivo measures of platelet quality showed no meaningful differences between filtered and unfiltered PCs by paired t test. The mean differences in posttransfusion percent recoveries and survivals were 0.9 +/- 2.9 percent and 4 +/- 13 hours, respectively. Additional studies were performed using a larger filter with improved capacity. Those studies (n = 18) showed a significant improvement in filtration time and platelet yield and a consistent 3 to 4 log10 reduction in WBCs. Filtration time was 6.6 +/- 2.7 minutes, total PC WBCs were 9.6 +/- 4.6 x 10(4), and total PC platelets were 7.8 +/- 1.8 x 10(10) (mean +/- SD). CONCLUSION: Prestorage filtration of PRP and the preparation of filtered platelets do not result in any significant beneficial or adverse effect on subsequent platelet quality. With the large-capacity filter, consistent WBC reduction and good platelet yields are achieved.

Blood Donors↗