Search PubMed⌕ Search

Biomedical subjects

S Hayase

Publications and source records attributed to S Hayase.

At least 73 records · Page 4Linked to original sources

The mean circulatory pressure, reproducibility of its measurements and the effect of phenylephrine with a note on the effect of pentobarbital.

With 7 repeated measurements of the mean circulatory pressure (MCP) over a course of 35 minutes in one and the same dog, and also with paired measurements of MCP 10 minutes apart in 6 other dogs, the MCP was shown to be stable and reproducible in anesthetized, open-chest and vagus-intact dogs. Administered to 7 dogs with initial mean arterial blood pressure as low as 64 mmHg in dose of 20 mug/kg intravenously, phenylephrine nearly doubled the mean arterial blood pressure, total peripheral resistance and the MCP, indicating a marked vasoconstrictor effect on the resistance and capacitance blood vessels of the systemic circulation. The effect was transient and there were signs of tachyphylaxis. Influence of a cardiotoxic dose of pentobarbital on the peripheal circulation was discussed.

Animals↗

Evaluation of the significance of scintillation angiocardiography for determination of the left ventricular volume.

A method for the determination of the left ventricular volume by scintillation angiocardiography following a peripheral venous injection of a radioactive isotope was described. Salient points in its methodology were as follows: 1. This volume study was composed of non-gated scintillation angiocardiography and cumulative gated scintiphotography. 2. The non-gated scintillation data were stored into video recording system. 3. The gated scintiphotography was performed during a play-back of non-gated scintillation data, opening the gate at desired points of time during a cardiac cycle. 4. The left ventricular scintillation image was photographied in life-size on x-ray film by superimposing, 10-20 times, the gated image of the several consecutive heart beats during the "left ventricular phase" of the dilution of intravenously injected radionuclide. For validation of this method, the stroke volume obtained with this method was compared with that obtained by precordial radionuclide dilution curve recordable during the non-gated scintillation angiocardiography, and also with that obtained by non-simultaneous radiocardiography. It was concluded that the present method may be sufficiently accurate for clinical use.

Adolescent↗

[Pericarditis].

Explore the source record for details and available documents.

Adult↗