Search PubMed⌕ Search

Biomedical subjects

S H Perlstein

Publications and source records attributed to S H Perlstein.

15 recordsLinked to original sources

Bilateral optic disc neovascularization in association with retinitis pigmentosa.

Bilateral neovascularization of the optic disc developed in a 16-year-old Hispanic girl with retinitis pigmentosa. The neovascularization regressed in both eyes over 1 year without treatment. Ocular and systemic evaluation failed to reveal a recognized cause for the neovascularization. To our knowledge this is only the third case reported of this unusual association.

Adolescent↗

Spontaneous remission of glaucoma in scleromalacia perforans: a case report.

Spontaneous resolution of glaucoma in a patient with scleromalacia perforans is described. Fluorophotometric measurements established the presence of normal aqueous production. The reduced intraocular pressure is ascribed to either autolysis of the trabecular meshwork and/or maximization of the uveoscleral pathway.

Aged↗

A new technique of visual field evaluation for unilateral ptosis.

A technique of uniocular visual field testing under binocular viewing conditions for evaluation of unilateral ptosis is described. The eye with the nonptotic lid is covered with a red filter, and both eyes fixate the white fixation light while a green test light is used. The resultant field reveals the true functional field loss due to the ptosis and avoids changes due to the patient elevating his brow.

Aged↗

New techniques in fundus examination: II. A new simplified technique for binocular indirect ophthalmoscopy.

A new technique of binocular indirect ophthalmoscopy uses a Finhoff transilluminator, held between the observer's eyes, as the light source. The light is focused in the patient's dilated pupil through a condensing lens in a darkened room and the image is seen stereoscopically. The advantages and limitations of this technique and the optical principles are highlighted.

Fundus Oculi↗

A new technique for portable gonioscopy.

We have developed a new technique for low-power gonioscopic examination of the anterior chamber angle. We use X4 binocular loupes for magnification and a portable halogen-streak retinoscope as the light source focused on a gonioscopic lens.

Bed Rest↗

A new technique for portable slit examination.

A new technique is presented for obtaining a portable low-power slit view of the cornea and anterior chamber by using a halogen streak retinoscope as the light source and binocular loupes or an aspheric + 20 diopter lens for magnification.

Anterior Chamber↗