Thyroid function testing evaluated on three immunoassay systems.

Total thyroxine (TT4), tracer uptake, thyroid-stimulating hormone (TSH), and free T4 (FT4) testing was examined in the ACS 180, Abbott IMx, and Stratus II systems. TSH sensitivity studies demonstrated that the ACS and IMx are second-generation assays; the Stratus showed between first- and second-generation performance. Except for one control below the detection limit, TSH imprecision was 3-10%. TSH accuracy was adequate for all systems. TT4 imprecision was 4-7%, except for the lowest control with the Stratus (18%). TT4 method agreement showed bias of about 20% between the systems. TT4 accuracy was compromised at the low end for the Stratus II, but was satisfactory otherwise. FT4 imprecision was 20% for the Stratus, < 5% for the IMx and 6% for the ACS. Uptake assays showed imprecision of 5-10%. The laboratory diagnosis indicated by each system's FT4 and calculated FT4 Index results were compared to determine diagnostic accuracy. In routine specimens, different clinical classifications were observed for 25% of specimens with the ACS, 19% with the Stratus, and 7% with the IMx; in the altered protein group, the Stratus showed 9% discordant results, the ACS showed 3%, and the IMx 0%. Of the three systems examined here, the Abbott IMx system showed the best overall performance.

Humans

Creatine kinase MM and MB isoforms in patients receiving thrombolytic therapy and acute angiography. TAMI Study Group.

Creatine kinase isoforms markers, including MB2 concentration, MB2/MB1 and MM3/MM1 ratios, and MT index (based on the "tissue" M subunits), were measured in serial specimens from 207 patients receiving thrombolytic therapy followed by acute angiography. The slope of release showed a significant relation (P < 0.05) between MB2 concentrations and patency, graded as TIMI 0 through TIMI 3; with regard to the precatheterization/baseline ratio, the MB2 concentrations, the MM3/MM1 ratio, and the MT index were all significantly related to graded patency (P < 0.004). Patients having patency graded as either TIMI 2/3 (Open) or TIMI 0/1 (Closed) showed highly significant differences (P < 0.03) in the slope of release and precatheterization/baseline ratio for all markers except the MB2/MB1 ratio. Defining Open as TIMI 3 and Closed as TIMI 0/1/2 showed very similar results. Despite these significant differences between the Open and Closed groups after thrombolytic therapy, none of the C index calculations (areas under ROC curves) for any of the isoform markers--either alone or combined--exceeded 0.70, suggesting that these markers have limited diagnostic utility for assessing patency.

Aged

Eight compact analysis systems evaluated for measuring total cholesterol.

We examined the analytical performance of eight compact systems for measuring total cholesterol: AccuMeter, Cobas Ready, Discovery f2, DT60, L-D-X, Reflotron, QCA, and Vision. We determined average bias at two decision levels, the mean absolute bias, and the percentage of results differing from the comparison method results by > 8.9% allowable total error limit for multiple reagent lots. Average bias was < 3% for all lots tested for AccuMeter, Discovery f2, and DT60, but > 3% for one or more lots or sample types tested with the other systems. Of results from each reagent lot, > 95% were within the 8.9% total error specifications with Discovery f2, DT60, and QCA, whereas the performance of L-D-X, Vision, and Reflotron depended on reagent lot and (or) sample type. Of all results from each lot tested with AccuMeter and Cobas Ready, > 5% exceeded the total allowable error limit. We determined imprecision for five systems: Cobas Ready, Discovery f2, and QCA had CVs < 3%, whereas CVs for AccuMeter and L-D-X were > 3% but < 5%.

Bias