Search PubMed⌕ Search

Biomedical subjects

S Garrigue

Publications and source records attributed to S Garrigue.

At least 37 records · Page 2Linked to original sources

Effects of multisite biventricular pacing in patients with heart failure and intraventricular conduction delay.

BACKGROUND: One third of patients with chronic heart failure have electrocardiographic evidence of a major intraventricular conduction delay, which may worsen left ventricular systolic dysfunction through asynchronous ventricular contraction. Uncontrolled studies suggest that multisite biventricular pacing improves hemodynamics and well-being by reducing ventricular asynchrony. We assessed the clinical efficacy and safety of this new therapy. METHODS: Sixty-seven patients with severe heart failure (New York Heart Association class III) due to chronic left ventricular systolic dysfunction, with normal sinus rhythm and a duration of the QRS interval of more than 150 msec, received transvenous atriobiventricular pacemakers (with leads in one atrium and each ventricle). This single-blind, randomized, controlled crossover study compared the responses of the patients during two periods: a three-month period of inactive pacing (ventricular inhibited pacing at a basic rate of 40 bpm) and a three-month period of active (atriobiventricular) pacing. The primary end point was the distance walked in six minutes; the secondary end points were the quality of life as measured by questionnaire, peak oxygen consumption, hospitalizations related to heart failure, the patients' treatment preference (active vs. inactive pacing), and the mortality rate. RESULTS: Nine patients were withdrawn from the study before randomization, and 10 failed to complete both study periods. Thus, 48 patients completed both phases of the study. The mean distance walked in six minutes was 22 percent greater with active pacing (399+/-100 m vs. 326+/-134 m, P<0.001), the quality-of-life score improved by 32 percent (P<0.001), peak oxygen uptake increased by 8 percent (P<0.03), hospitalizations were decreased by two thirds (P<0.05), and active pacing was preferred by 85 percent of the patients (P<0.001). CONCLUSIONS: Although it is technically complex, atriobiventricular pacing significantly improves exercise tolerance and quality of life in patients with chronic heart failure and intraventricular conduction delay.

Angiotensin-Converting Enzyme Inhibitors↗

HLA-DR expression on lymphocyte subsets as a marker of disease activity in patients with systemic lupus erythematosus.

A major problem in the management of SLE patients is to predict a flare or to distinguish between active and quiescent disease. Serological markers are widely used to assess disease activity, but many patients have close to or normal values for these parameters while exhibiting obvious disease-related signs and symptoms. This study aimed to determine which serological parameters, among ESR, ANA and anti-dsDNA antibody titres, CH50 and the HLA-DR expression on circulating T-lymphocyte subsets, best reflected the development of SLE flares. Sixty SLE patients were included, 34 with quiescent disease throughout the entire follow-up period and 26 who experienced an SLE flare defined as having active disease. According to univariate analysis, all parameters were significantly higher for patients with active disease, with the percentage of CD8+DR+ cells being the most significant parameter (P = 10-7). Multivariate logistic regression analysis identified three independent variables enabling the identification of a lupus flare: CH50, the CD8+DR+ and CD4+DR+ cell percentages among total lymphocytes. The CD8+DR+ cell percentage is the biological parameter most significantly associated with a flare (P < 0.001), even more powerful than CH50 (P < 0.01). HLA-DR expression on CD8+ lymphocytes clearly coincided with disease evolution in seven patients enrolled as having quiescent disease, but who experienced one flare during follow-up that subsequently resolved. The percentage of circulating CD8+DR+ lymphocytes appears to be a biological marker which accurately reflects disease activity. A larger prospective study is needed to demonstrate the real efficacy of this marker in predicting an exacerbation in SLE patients.

Adolescent↗

Transvenous left atrial and left ventricular pacing in Ebstein's anomaly with severe interatrial conduction block.

The implantation of permanent pacemakers in patients with congenital heart disease can be challenging. This report describes the complexity of pacemaker implantation in a patient with Ebstein's disease, tricuspid valve replacement, and right atrial abnormalities like severe intra- and interatrial conduction block that prevented dual chamber pacing from conventional sites. This case illustrates the promising possibility to circumvent the interatrial conduction block with single left atrial pacing instead of biatrial pacing which was not suitable here.

Cardiac Pacing, Artificial↗

Validation by serial standardized testing of a new rate-responsive pacemaker sensor based on variations in myocardial contractility.

AIMS: Preliminary studies have shown that peak endocardial acceleration (PEA), measured by a micro-accelerometer at the right ventricular apex, is highly correlated with left ventricular contractility (dp/dt max). Furthermore, changes in PEA are closely correlated with sinus node rate changes during exercise and during pharmacological interventions. Peak endocardial acceleration has, therefore, been used to drive a rate-responsive DDD pacemaker. This study compared the chronotropic performance of such devices implanted in 14 patients suffering from chronotropic incompetence with that observed in 18 control subjects in normal sinus rhythm. METHODS AND RESULTS: Five standardized daily life activities (hall walk, climbing up and down stairs, squatting and hyperventilation) and two types of exercise (Bruce treadmill protocol and bicycle ergometry) were performed in a random order after individual programming of each pacemaker. For each test, a correlation coefficient was calculated between changes in PEA and variations in paced rate, between instantaneous variations in heart rate monitored by telemetry and continuous measurement of heart rate by the pacemaker, and between sensor-driven rate in patients and normal sinus rhythm in controls. The variations in paced heart rate were closely correlated with those observed in subjects with normal sinus rhythm, and proved to be sensitive, specific, rapid and independent of the type of exercise. After optimal programming of the sensor, PEA modulates the heart rate as expected during normal sinus rhythm. CONCLUSIONS: In this study, a single PEA sensor successfully restored chronotropic response in a population of paced patients with severe chronotropic incompetence. Peak endocardial acceleration can be monitored on a beat-to-beat basis, in parallel with heart rate, and the pacemaker can be accurately programmed with a single exercise test.

Aged↗

Electrophysiological breakthroughs from the left atrium to the pulmonary veins.

BACKGROUND: The extent of ostial ablation necessary to electrically disconnect the pulmonary vein (PV) myocardial extensions that initiate atrial fibrillation from the left atrium has not been determined. METHODS AND RESULTS: Seventy patients underwent PV mapping with a circumferential 10-electrode catheter during sinus rhythm or left atrial pacing. After assessment of perimetric distribution and activation sequence of PV potentials, ostial ablation was performed at segments showing earliest activation, with the end point of PV disconnection. A total of 162 PVs (excluding right inferior PVs) were ablated. PV potentials were present at 60% to 88% of their perimeter, but PV muscle activation was always sequential from a segment with earliest activation (breakthrough). Radiofrequency (RF) application at this breakthrough eliminated all PV potentials in 34 PVs, whereas a secondary breakthrough required RF applications at separate segments in 77; in others, >2 segments were ablated. A median of 5, 6, and 4 bipoles from the circular catheter were targeted in the right superior, left superior, and inferior PVs, respectively, to achieve PV disconnection. Early recurrence of arrhythmia was observed in 31 patients as a result of new venous or atrial foci or recovery of previously targeted PVs, most related to a single recovered breakthrough that was reablated with local RF application. CONCLUSIONS: Although PV muscle covers a large extent of the PV perimeter, there are specific breakthroughs from the left atrium that allow ostial PV disconnection by use of partial perimetric ablation.

Angiography↗

Mapping-guided ablation of pulmonary veins to cure atrial fibrillation.

Catheter ablation of triggers inducing paroxysms of atrial fibrillation (AF) is an emerging therapy for this common arrhythmia. In a series of 225 consecutive patients with AF resistant to multiple drugs, 96% presented with triggering foci originating from 1 or multiple pulmonary veins (PV), independently of whether or not the patient had ectopy or structural heart disease. The present article describes the mapping and ablation techniques applicable to individual patients: (1) criteria to define an arrhythmogenic PV; (2) use of provocative maneuvers; and (3) the role of circumferential mapping catheters to provide extent, distribution, and activation of PV muscle as well as monitoring distal PV potentials (PVP) during ablation. Radiofrequency ablation can be performed by targeting the PVP during sinus rhythm (right PV) or left atrial pacing (left PV) with the procedural endpoint of PVP elimination, which is more effective in predicting a successful outcome than suppression of acute ectopy. Complete elimination of AF is presently obtained in 70% of patients, allowing interruption of arrhythmias and in use anticoagulants. It is anticipated that continued technologic improvements will improve and facilitate this technique of curative treatment of AF.

Atrial Fibrillation↗

Mapping and ablation of left atrial flutters.

BACKGROUND: Typical right atrial isthmus-dependent flutters have been described in detail, but very little is known about left atrial (LA) flutters. METHODS AND RESULTS: We performed conventional and 3D mapping of the LA for 22 patients with atypical flutters. Complete maps in 17 patients demonstrated macroreentrant circuits (n=15) with 1 to 3 loops rotating around the mitral annulus, the pulmonary veins, and a zone of block or a silent area. In 2 patients, a small reentry circuit with a zone of markedly slow conduction was identified. Linear ablation performed across the most accessible part of the circuit cured 16 patients (73%) with a follow-up of 15+/-7 months. CONCLUSIONS: LA reentrant tachycardias are related to individually varying circuits and are amenable to mapping guided radiofrequency ablation.

Adult↗

Electrophysiological end point for catheter ablation of atrial fibrillation initiated from multiple pulmonary venous foci.

BACKGROUND: The end point for catheter ablation of pulmonary vein (PV) foci initiating atrial fibrillation (AF) has not been determined. METHODS AND RESULTS: Ninety patients underwent mapping during spontaneous or induced ectopy and/or AF initiation. Ostial PV ablation was performed by use of angiograms to precisely define targeted sites. Success defined by elimination of AF without drugs was correlated with the procedural end point of the abolition of distal PV potentials. A total of 197 arrhythmogenic PV foci (97%)-single in 31% and multiple in 69%-and 6 atrial foci were identified. A discrete radiofrequency (RF) application eliminated the PV potentials in 9 PV foci, whereas 2 foci from the same PV required RF applications at separate sites in 19 cases. In others, a wider region was targeted with progressive elimination of ectopy. In 49 patients, multiple sessions were necessary owing to recurrent or new ectopy. The clinical success rates were 93%, 73%, and 55% in patients with 1, 2, and > or =3 arrhythmogenic PV foci. Recovery of local PV potential and the inability to abolish it were significantly associated with AF recurrences (90% success rate with versus 55% without PV potential abolition). PV stenosis was noted acutely in 5 of 6 cases, remained unchanged at restudy, and was associated with RF power >45 W. CONCLUSIONS: Multiple PV foci are involved in initiation of AF, and elimination of PV muscle conduction is associated with clinical success.

Adult↗

Prospective randomized comparison of irrigated-tip versus conventional-tip catheters for ablation of common flutter.

BACKGROUND: Radiofrequency (RF) ablation of common flutter requires the creation of a complete ablation line to produce bidirectional conduction block in the cavotricuspid isthmus. An irrigated-tip ablation catheter has been shown to be effective in patients in whom conventional ablation has failed. This randomized study compares the efficacy and safety of this catheter with those of a conventional catheter for de novo flutter ablation. METHODS AND RESULTS: Cavotricuspid ablation was performed with a conventional (n=26) or an irrigated-tip catheter (n=24). RF was applied for 60 minutes with a temperature-controlled mode: 65 degrees C to 70 degrees C up to 70 W with a conventional catheter or 50 degrees C up to 50 W (with a 17-mL/min saline flow rate) with the irrigated-tip catheter. The end point was the achievement of bidirectional isthmus block, and a crossover was performed after 21 unsuccessful applications. Procedural ablation parameters as well as number of applications, x-ray exposure, procedure duration, impedance rise, and clot formation were compared for each group. A coronary angiogram was performed before and after each ablation for the first 30 patients. Complete bidirectional isthmus block was achieved for all patients. Four patients crossed over from conventional to irrigated-tip catheters. The number of applications, procedure duration, and x-ray exposure were significantly higher with the conventional than with the irrigated-tip catheter: 13+/-10 versus 5+/-3 pulses, 53+/-41 versus 27+/-16 minutes, and 18+/-14 versus 9+/-6 minutes, respectively. No significant side effects occurred, and the coronary angiograms of the first 30 patients after ablation were unchanged. CONCLUSIONS: Irrigated-tip catheters were found to be more effective than and as safe as conventional catheters for flutter ablation, facilitating the rapid achievement of bidirectional isthmus block.

Aged↗

Atrial fibrillation: role of arrhythmogenic foci.

UNLABELLED: Atrial fibrillation, the most common of all sustained cardiac arrhythmias can be cured by Surgical atriotomies or linear RF catheter ablation. We have investigated the role of focal RF ablation in paroxysmal atrial fibrillation. METHODS: sixteen patients with focal atrial fibrillation (extrasystoles, atrial tachycardia and atrial fibrillation due to the same focus firing irregularly at different rates) and 45 with common AF initiated by extrasystolic foci were included. The ablation site was determined on the basis of earliest bipolar activity relative to a stable atrial electrogram reference or to the P wave onset during atrial fibrillation initiation. RESULTS: All the patients with focal atrial fibrillation were treated with a mean of 5 +/- 4 RF applications delivered on a right atrial site (n = 4) or on a pulmonary venous site (n = 13), (one patient had 2 foci). Sixty nine foci (located in the pulmonary veins in 94%) were identified in the 45 patients with common atrial fibrillation initiated by extrasystoles. They were ablated with a mean of 4.5 +/- 2 RF applications. Using a mean follow up of 8 +/- 6 months, 28/45 (62%) were cured without antiarrhythmic drugs. CONCLUSION: Pulmonary veins play an important role in paroxysmal atrial fibrillation. They are the most frequent source of focal atrial fibrillation and of initiating foci amenable to RF ablation.

Adult↗

Intermediate-term results of biventricular pacing in heart failure: correlation between clinical and hemodynamic data.

Biventricular (BV) pacing acutely improves the hemodynamic status of patients with chronic heart failure (CHF) and wide QRS complex. Long-term data are few. This study examined the relationship between hemodynamic and clinical status of BV-paced CHF patients over an intermediate duration of follow-up. Forty-seven patients (mean age 64 +/- 11 years, 19% women, LVEF 0.23 +/- 0.07) with QRS > or = 140 ms received a DDD-BVP device for management of CHF due to ischemic disease in 21 (45%) patients. Clinical, electrocardiographic, exercise testing, and hemodynamic measurements were followed over an 8-month period. Seven patients died during the study, four patients suddenly. A significant decrease in NYHA class, from 3.3 +/- 0.6 before implantation, to 2.5 +/- 0.57 months after device implantation (P < 0.01) was measured, although 23% of patients reported no symptomatic improvement. Paced QRS narrowing by BVP was unchanged throughout follow-up (166 +/- 28 vs 159 +/- 23 ms, P = NS). Maximal VO2 values did not change (15.7 +/- 5 vs 16 +/- 8 mL/kg per min, P = NS). Echocardiographic parameters showed that the degree of mitral regurgitation was significantly decreased during BV pacing compared with no pacing (1.8 +/- 1.0 before implantation vs 1.3 +/- 0.7, P < 0.01). The radionuclide LVEF was not statistically different during no pacing, versus BV pacing at 3 months or 8 months after pacemaker implantation (24 +/- 9 vs 26 +/- 11 vs 25 +/- 10%, respectively, P = NS). Of nine patients whose QRS duration was prolonged by BV pacing, two were not hemodynamically and clinically improved at the end of follow-up. Patients not improved by BV pacing had the same degree of QRS shortening (203 +/- 39 vs 167 +/- 26 ms, P < 0.01) as patients who were clinically improved during follow-up (193 +/- 40 to 171 +/- 24 ms, P < 0.01). In multivariate analysis, ischemic heart disease (P = 0.025), absence of mitral regurgitation regression (P = 0.01), and older age (P = 0.04) predicted the absence of improvement by BV pacing. By standard noninvasive measures, intermediate-term BV pacing was associated with no objective hemodynamic improvement, though more than three fourths of the patients reported being clinically improved. A global improvement in left ventricular function by BV pacing may become apparent only over longer periods of observations. Patients with CHF unimproved by BV pacing are more likely to suffer from ischemic heart disease and less likely to have BV pacing induced regression of mitral regurgitation, regardless of changes in QRS duration.

Blood Flow Velocity↗

Hemodynamic assessment of right, left, and biventricular pacing by peak endocardial acceleration and echocardiography in patients with end-stage heart failure.

Multisite ventricular pacing acutely improves the hemodynamic status in heart failure, though longer-term observations require invasive procedures. The hemodynamics of multisite ventricular pacing were assessed by echocardiography and peak endocardial acceleration (PEA) measured by a pacemaker sensor. PEA variations are highly correlated with those of dP/dt. Thirteen end-stage heart failure patients (left ventricular ejection fraction < 0.30) with a QRS > or = 140 ms received a DDD PEA sensor-driven pacemaker allowing right (RV), left (LV) and biventricular (BV) pacing. Ten days after implantation, standard echocardiographic parameters and variations in PEA were measured after 20 minutes at each pacing mode. The aortic systolic preejection time interval was statistically comparable between RV and LV pacing (218 +/- 24 vs 219 +/- 34 ms; P = NS), and significantly shorter with BV pacing (198 +/- 27 ms; P = 0.013). Aortic ejection duration was nonsignificantly shorter during BV pacing than during LV pacing (-.061, P = 0.09). The aortic velocity time integer increased during LV pacing versus RV pacing (+21%, P < 0.05) and during BV pacing versus RV pacing (+37%, P = 0.05). As a result, the values of the PEA variations over a 15-minute period were significantly greater during LV pacing and BV pacing versus RV pacing (+43%, P < 0.05, and +38%, P = 0.05, respectively) and were statistically comparable between BV pacing and LV pacing (9% for LV pacing, P = NS). During various ventricular pacing configurations, PEA measurements were consistent with echocardiographic data, showing comparable hemodynamic effects of BV and LV pacing. The PEA sensor is a promising tool for long-term hemodynamic monitoring and serial evaluation of the effects of multisite ventricular pacing in heart failure patients.

Cardiac Pacing, Artificial↗

Mid-term follow-up of endocardial biventricular pacing.

Biventricular (BV) pacing is a promising treatment of end-stage heart failure. This article describes our experience with a strictly endocardial BV pacing system in patients with severe congestive heart failure. Three women and eight men (age 65 +/- 9 years) with drug-resistant end-stage CHF underwent implantation of an endocardial BV pacing system. In the first seven patients, the left ventricular lead was placed via a combined femoral and internal jugular approach. In the last four patients, the transseptal puncture was directly performed via the right internal jugular vein with a dedicated kit. The procedure was successful in all 11 patients. The acute left ventricular and BV thresholds were 1.3 +/- 0.6 V and 2.4 +/- 1 V, respectively. The QRS duration decreased from 214 +/- 57 to 176 +/- 25 ms. A functional improvement was noted in ten patients with a decrease in mean NYHA functional class from 3.7 +/- 0.5 before, to 2.6 +/- 0.9 after system implantation. A significant decrease in pulmonary capillary wedge pressure and increase in cardiac output were measured in eight patients. During follow-up, four patients died from CHF (n = 3) or ventricular fibrillation (n = 1). Under oral anticoagulation, no thromboembolic event was observed but one transient ischemic attack occurred in one patient whose anticoagulation was interrupted. Endocardial BV pacing is technically feasible and appears safe, though further studies are needed before it is used on a longer scale.

Aged↗

Multiple sources initiating atrial fibrillation from a single pulmonary vein identified by a circumferential catheter.

The pulmonary veins are the predominant source of ectopic activity initiating AF. The reproducibility of intrapulmonary vein activation during ectopic activity and/or initiation of multiple AF episodes was examined. Eighty-nine pulmonary veins (PVs) among 29 patients undergoing radiofrequency ablation of AF were studied with a 15- to 20-mm diameter, circumferential PV catheter equipped with ten electrodes and a deflectable shaft. Local electrograms were recorded simultaneously during sinus rhythm, ectopic activity, or AF onset, spontaneously or induced via the catheter left in a stable position. Fifty-four arrhythmogenic veins were identified, 39 showing isolated ectopy, and 8 displayed repetitive ectopy (in salvos). The earliest site of activation and the sequence of intra-PV activation during isolated ectopy was identical to that observed during consecutive ectopic complexes in 77% and variable in 23% during isolated ectopy. The earliest activity was sometimes limited to a single bipole. During repetitive ectopy and AF initiation, multiple sources and/or variable activation patterns were noted in 53% of instances, indicating the presence of multiple arrhythmogenic foci within the same PV. Simultaneous electrogram recordings with a circumferential PV catheter identified the presence of multiple arrhythmogenic foci within a single PV.

Atrial Fibrillation↗

Concealed left pulmonary vein potentials unmasked by left atrial stimulation.

Pulmonary vein potentials (PVPs), though obvious during ectopic activity, are frequently invisible during sinus rhythm when they need to be distinguished from left atrial (LA) potentials to perform successful ablation procedures. Thirty-six patients with paroxysmal atrial fibrillation underwent circumferential PV mapping with a circular ten-electrode catheter during sinus rhythm, and during pacing from the right atrium, proximal and distal coronary sinus (CS), and LA. Ablation was performed at the ostium of the PV, the procedural endpoint consisting of electrical disconnection of the PV from the LA. A total of 93 PVs (excluding the right inferior PV) were mapped. During sinus rhythm, distinct right PVPs were present in all instances, while they were concealed within the electrograms recorded from the left inferior and superior PV in 23 (64%) patients. Distal CS or LA appendage pacing unmasked and separated left PV from LA potentials by a mean of 19 +/- 14 ms; the LA-to-left-PV potential interval measured 36 +/- 14 ms. The number of deflections also increased from 2.1 +/- 0.7 during sinus rhythm to 3 +/- 1.4 during LA stimulation. However, in the right superior PV, pacing caused overlapping of atrial potentials with right superior PVPs. RF ablation of the left PVPs was performed during distal or LA pacing in 23 patients, while in the right superior PV it was performed during sinus rhythm eliminating all, including unmasked, left PVPs, providing proof of their PV origin. Distal CS or LA pacing is required to recognize left PVPs in approximately 2/3 of patients and facilitates RF ablation.

Atrial Fibrillation↗