Search PubMed⌕ Search

Biomedical subjects

S G Ruehm

Publications and source records attributed to S G Ruehm.

At least 37 records · Page 2Linked to original sources

Magnetic resonance imaging of atherosclerotic plaque with ultrasmall superparamagnetic particles of iron oxide in hyperlipidemic rabbits.

BACKGROUND: Based on the observation that ultrasmall superparamagnetic particles of iron oxides (USPIOs) are phagocytosed by cells of the mononuclear phagocytic system, the purpose of this study was to evaluate their use as a marker of atherosclerosis-associated inflammatory changes in the vessel wall before luminal narrowing is present. METHODS AND RESULTS: Experiments were conducted on 6 heritable hyperlipidemic and 3 New Zealand White rabbits. 3D MR angiography (MRA) of the thoracic aorta was performed on all rabbits by use of a conventional paramagnetic contrast agent that failed to reveal any abnormalities. One week later, all rabbits except 1 of the hyperlipidemic animals were injected with a USPIO contrast agent (Sinerem, Guerbet) at a dose of 1 mmol Fe/kg. 3D MRA data sets collected over the subsequent 5 days showed increasing signal in the aortic lumen. Whereas the aortic wall of the control rabbits remained smooth and bright, marked susceptibility effects became evident on day 4 within the aortic walls of hyperlipidemic rabbits. Ex vivo imaging of aortic specimens confirmed the in vivo results. Histopathology documented marked Fe uptake in macrophages embedded in atherosclerotic plaque of the hyperlipidemic rabbits. Electron microscopy showed multiple cytoplasmic Fe particles in macrophages. No such changes were seen in control rabbits or in the hyperlipidemic rabbit that had not received Sinerem. CONCLUSIONS: USPIOs are phagocytosed by macrophages in atherosclerotic plaques of the aortic wall of hyperlipidemic rabbits in a quantity sufficient to cause susceptibility effects detectable by MRI.

Animals↗

Dynamic 3D MR angiography of the pulmonary arteries in under four seconds.

Although 3D MRA has been shown to provide excellent depiction of the pulmonary arterial tree, its clinical use has been limited due to lengthy breath-holding requirements. Employing the newest gradient generation (1.5 T MR system, amplitude of 40 mT/m and a slew rate of 200 mT/m/msec), we evaluated a technique permitting the dynamic acquisition of 3D data sets of the entire pulmonary tree in under 4 seconds. Coronal image sets were collected using a repetition time of 1.64 msec and an echo time of 0.6 msec, resulting in an acquisition time of 3.74 seconds. Three volunteers and eight dyspneic patients with known or suspected pulmonary embolism underwent MRI of the pulmonary arteries. The pulmonary arterial tree was visible to a subsegmental level in all examined subjects. Regarding the presence of pulmonary emboli in four patients, there was complete concordance between MR angiographic findings and those of corroborative studies. We conclude that diagnostic MRA of the pulmonary vasculature can be obtained even in patients with severe respiratory distress.

Dyspnea↗

3D contrast-enhanced MR angiography of the run-off vessels: value of image subtraction.

The diagnostic gain associated with image subtractions was assessed regarding contrast-enhanced 3D magnetic resonance angiography (MRA) image sets of the pelvic and lower extremity arteries. The MRA strategy combined a dedicated vascular coil with a single injection, two-station protocol. Voxel-by-voxel signal intensity subtraction was performed on MRA image sets obtained before and during dynamic infusion of a para-magnetic contrast agent. Non-subtracted and subtracted MRA image sets were assessed for the presence of occlusive (four grades) disease, using DSA as the standard of reference. In addition, SNR and CNR were recorded for each vascular segment on both the non-subtracted and subtracted images. While CNR values of subtracted images exceeded those of non-subtracted images (P < 0.05), there was no difference in diagnostic performance. For the detection of hemodynamically significant disease, non-subtracted and subtracted MRA provided overall sensitivity and specificity of 90.2%/90.3% and 95.1%/95.6%, respectively. Concordance between non-subtracted and subtracted MRA was excellent (Kappa = 0.86).

Aged↗

Pulmonary arteriovenous malformation: Characterization with time-resolved ultrafast 3D MR angiography.

To avoid potentially deadly consequences from paradoxical emboli, early detection and accurate characterization of pulmonary arteriovenous malformations (AVMs) is highly desirable. We report on a patient with a suspected pulmonary AVM who underwent ultrafast time-resolved 3D MR angiography of the pulmonary arteries. The case documents the suitability of the MRA technique as a noninvasive alternative to computed tomographic angiography and digital subtraction angiography for accurate pre-therapeutic characterization of pulmonary AVMs.

Arteriovenous Malformations↗

Improved multi-station peripheral MR angiography with a dedicated vascular coil.

Delineation of small branch vessels can be crucial for assessing the peripheral arterial system of patients requiring surgical grafting. Thus signal-to-noise needs to be maximized. We evaluated the performance of a dedicated peripheral vascular coil in four subjects by comparing it to the body coil using DSA as the standard of reference. SNR and CNR values of the dedicated peripheral coil exceeded those obtained with the body coil by a mean of 398%, thus permitting improved delineation of the infrapopliteal arterial morphology.

Adult↗

0.5 M Gd chelate (Magnevist) versus 1.0 M Gd chelate (Gadovist): dose-independent effect on image quality of pelvic three-dimensional MR-angiography.

To compare the effect on image quality of a 1.0 M gadolinium (Gd) chelate to that of a conventional 0.5 M Gd chelate, five healthy volunteers and seven patients with angiographically documented aorto-iliac disease underwent a mono-station three-dimensional magnetic resonance angiography (MRA) exam (Siemens SONATA, Erlangen, Germany) twice, once using Gadovist 1.0 and the other time using Magnevist as the contrast agent. All subjects received a fixed volume of Gadovist 1.0, corresponding to a dose between 0.1 and 0.15 mmol/kg body weight followed by a saline flush. For the Magnevist exam, the contrast agent volumes and flow rates were doubled. For both quantitative and qualitative analysis of the angiographic data sets, the arterial tree was divided into nine segments. 1 M Gadovist 1.0-enhanced three-dimensional MRA data sets were characterized by significantly higher signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) values compared to 0.5 M Magnevist-enhanced images. The data revealed mean SNR/CNR increases exceeding 70% (P < 0.01). Although there was no statistically significant difference in the rating of image quality (P > 0.05), the Gadovist 1.0 exam led to better delineation of the arterial morphology, especially of small vessels.

Adult↗

Direct contrast-enhanced 3D MR venography.

Non-enhanced two-dimensional (2D) time-of-flight (TOF) MRA is well established for imaging of the deep venous system. However, based on the acquisition of multiple axial images, it can be time-consuming and often fails to delineate small superficial and perforating veins. The presented low-dose, direct-contrast-injection 3D MR venography technique allows rapid acquisition of high-quality MR venograms and can be employed for the display of the deep and superficial venous system of upper and lower extremity including pelvic and central thoracic veins. This article describes the employed technique and provides a comprehensive image-based overview of the various indications for direct-infusion 3D MR venography such as post-/thrombotic changes, varicosities, and assessment of the greater saphenous vein prior to bypass surgery.

Contrast Media↗

Three-dimensional dynamic MR hysterosalpingography: a preliminary report.

The aim of this study was to evaluate the feasibility of three-dimensional dynamic MR hysterosalpingography (3D MR HSG) for visualization of the cavum uteri and demonstration of bilateral fallopian tube patency as an alternative to conventional hysterosalpingography. Five infertile female patients underwent 3D dynamic MR HSG prior to conventional hysterosalpingography. The MR protocol consisted of axial T1-weighted spin-echo (SE), axial/coronal T2-weighted fast SE (FSE), and 3D MR angiography sequences before, during, and after injection of a diluted gadolinium solution into the cavum uteri via a balloon catheter. Positioning of the catheter was feasible in all patients. In one patient the catheter slipped out during MRI and in one patient the catheter was placed far in the cavum uteri. In three patients catheter position was optimal at the level of the cervical canal. Evaluation of pelvic anatomy, myometrium, and ovaries was possible in all patients on the basis of T1-weighted SE and T2-weighted FSE. Three-dimensional visualization of the dilated cavum uteri was possible in four patients. In these four patients 3D MR HSG also proved bilateral fallopian tube patency which was confirmed in each patient by conventional hysterosalpingography. Three-dimensional MR HSG is feasible and further research should be done to determine if this technique can evolve into an alternative technique to conventional hysterosalpingography with the advantages of no radiation and additional visualization of the uterus wall and ovaries.

Adult↗

[Contrast-enhanced 3D MR venography of central thoracic veins: preliminary experience].

PURPOSE: To evaluate the usefulness of three-dimensional (3D) gadolinium-enhanced magnetic resonance (MR) venography for evaluation of thoracic central veins. MATERIALS AND METHODS: Over a 4-month period, 14 patients with suspected central venous abnormalities were examined on a 1.5 T scanner (Magnetom Sonata, SIEMENS, Germany) by means of MR venography. A FLASH-3D sequence using the following parameters was employed: TR 1.6 ms, TE 0.6 ms, TA 3.74 s, flip: 15 degrees, slab thickness 110 mm, effective slice thickness: 2.75 mm, 40 partitions, FOV 360 mm, matrix 140 x 256. 10 s prior to imaging 20 ml of Gd-DOPTA (Multihance, BRACCO, Italy) were automatically injected (MEDRAD, Pittsburgh, USA) flushed by 20 ml of normal saline (flow 4 ml/s). Six 3D data sets were acquired in immediate succession in under 24 s. Results were corroborated with findings from duplex sonography. RESULTS: MR venograms were of diagnostic quality for all 14 patients. Compared to duplex sonography thromboses, post-thrombotic changes as well as functional compressions were reliably detected. Unsuspected findings were found in two patients. CONCLUSION: The outlined strategy allows for dynamic diagnostic imaging of central thoracic veins. Gadolinium-enhanced breath-hold 3D MR venography is easy to perform, well tolerated and highly accurate in assessing central venous pathology.

Adult↗

Dark lumen MR-colonography: initial experience.

PURPOSE: The aim of this study was to assess a new strategy of MR colonography for the detection of colonic polyps/malignancy. The technique is based on a rectal enema with water in combination with the intravenous application of a paramagnetic contrast agent. METHODS: Twelve subjects were included in this study either due to suspected colorectal tumors or for screening purposes. For MR colonography the colon was filled with approximately 3000 ml of tap water while Gadobenate dimeglumine (0.2 mmol/kg) was injected intravenously. A T1w GRE sequence was acquired before and 75 sec after the contrast administration only in prone position. Three patient underwent the "bright lumen" MRC as well. All MR examinations were performed at least five days prior to conventional colonoscopy and the results of both modalities were compared. RESULTS: The colonic filling with water resulted in a homogeneously low signal throughout the colonic lumen in all twelve subjects. Intravenous injection of gadolinium caused avid enhancement of the colonic wall. Similarly lesions arising from the colonic wall enhanced avidly. Dark lumen MR colonography correctly identified five polyps in four patients. Bright lumen MRC showed in one patient false positive results. CONCLUSION: The new MR colonography concept based on a dark colonic lumen and a bright, contrast enhanced colonic wall turned out to be a promising alternative to the traditional MRC based on a bright lumen concept. The new technique suggests a higher accuracy in detecting polyps, a better evaluation of other parenchymal organs as well as a reduced time needed for data acquisition and analysis.

Adult↗

Peripheral magnetic resonance angiography.

Peripheral vascular disease (PVD) is a common disorder in western society. Reflecting on the risks and costs of contrast arteriography, magnetic resonance angiography is a powerful noninvasive imaging modality for the diagnostic workup of patients with peripheral vascular disease. This article reviews the current state of the art of magnetic resonance angiography of the peripheral vasculature.

Contrast Media↗

Interstitial MR lymphography with gadoterate meglumine: initial experience in humans.

Magnetic resonance (MR) lymphography was performed in five healthy volunteers and three patients (two adults and one infant). Subcutaneous administration of gadoterate meglumine in the foot allowed visualization of draining lymph vessels and nodes. In one patient, an inguinal fluid collection could be characterized as a lymphocele. In the infant, a chylothorax was diagnosed. The authors conclude that interstitial MR lymphography with commercially available compounds is feasible.

Adult↗

Interstitial MR lymphography with a conventional extracellular gadolinium-based agent: assessment in rabbits.

PURPOSE: To evaluate gadoterate meglumine as a contrast agent for interstitial magnetic resonance (MR) lymphography in combination with an adapted fast three-dimensional (3D) MR sequence. MATERIALS AND METHODS: In 12 New Zealand White rabbits, 0.5 mL of undiluted gadoterate meglumine was injected subcutaneously into the dorsal foot pad (n = 9) or the foreleg (n = 3) bilaterally. Immediately after administration, a slight massage was performed at the injection site. Imaging was performed with a 3D spoiled gradient-recalled echo sequence (6.7/1.6 [repetition time msec/echo time msec]; field of view, 28.0 x 19.6; two signals acquired) similar to that used for 3D MR angiography. Thus, 3D maximum intensity projection images could be obtained. Images were obtained before injection and 5, 15, 30, 60, and 120 minutes after injection. RESULTS: In the hind legs, as many as four successive lymph node groups were depicted with maximum enhancement after 5-15 minutes for the popliteal lymph node group, 15-30 minutes for the inguinal lymph group, and 30-60 minutes for the iliac-paraaortal lymph node group; the iliac-paraaortal lymph node group was not consistently enhanced. In the forelegs, four successive lymph node groups, including axillary and mediastinal lymph node groups, showed marked gadolinium uptake, with maximum enhancement 5-15 minutes after injection. CONCLUSION: As a widely tested positive-enhancing T1 contrast agent with favorable safety features, gadoterate meglumine allows the depiction of three to four successive lymph node groups early after subcutaneous injection. With the sequence used, 3D MR lymphangiograms can be obtained.

Animals↗

MR evaluation of ventricular function: true fast imaging with steady-state precession versus fast low-angle shot cine MR imaging: feasibility study.

Short- and long-axis cine magnetic resonance (MR) images were obtained with a standard fast low-angle shot, or FLASH, sequence and a first-generation true fast imaging with steady-state precession (FISP) sequence on a 1.5-T MR imager. Contrast-to-noise ratios and volumetric left ventricular measurements were compared for manual and automatic segmentation. True FISP images were associated with significantly (P<.01) higher contrast-to-noise ratios and allowed better detection of the endocardial border. True FISP images were provided with short acquisition times and excellent contrast between the myocardium and the ventricular lumen.

Adult↗

Whole-body MR imaging in 30 seconds with real-time true FISP and a continuously rolling table platform: feasibility study.

A technique for whole-body magnetic resonance (MR) imaging in only 30 seconds was developed on the basis of a rolling table platform with integrated surface coils and real-time true fast imaging with steady-state precession. In five patients, all hepatic and pulmonary lesions with a diameter exceeding 8 mm were detected by using thoracic and abdominal helical computed tomography as the reference method. Whole-body MR imaging with real-time true fast imaging with steady-state precession is feasible and may be suitable for tumor screening and staging.

Adult↗

Surveillance of peripheral arterial bypass grafts with three-dimensional MR angiography: comparison with digital subtraction angiography.

OBJECTIVE: The purpose of this study was to use contrast-enhanced three-dimensional MR angiography to assess the patency of peripheral arterial bypass grafts of the lower extremity. SUBJECTS AND METHODS: The study included 39 patients with 45 lower limb grafts. Twenty-eight were saphenous vein grafts, 13 were expanded polytetrafluoroethylene, and two were Dacron grafts. Digital subtraction angiography correlation was available for 30 patients (31 grafts). MR angiography was performed on a 1.5-T system with a multichannel quadrature phased array peripheral vascular coil. The scanning delay was determined with a test bolus technique, using half-time to maximum signal intensity in the graft. Arterial imaging was accomplished with two three-dimensional MR angiography acquisitions with gadopentetate dimeglumine administered using an automated injector. The pelvic and femoral arteries were imaged, the MR table was repositioned, and the lower limb arteries were imaged. The three-dimensional MR angiography sequence used the following parameters: TR/TE, 5.2/1.5 msec; inversion time, 28 msec; flip angle, 30 degrees. The proximal anastomosis, graft, and distal anastomosis were characterized as normal, stenosed, occluded, or ectatic or aneurysmatic. RESULTS: Sensitivity and specificity values for MR angiography regarding the assessment of grafts were 100% for 87 evaluable segments for which digital subtraction angiography correlation was available: stenosis (n = 10), occlusions (n = 9), ectasia or aneurysms (n = 8). Six segments could not be assessed because of the presence of intravascular stents or metallic clips. CONCLUSION: Contrast-enhanced three-dimensional MR angiography is well suited for the characterization of arterial grafts, for planning subsequent vascular interventions, and for excluding further lesions.

Aged↗

MR colonography without colonic cleansing: a new strategy to improve patient acceptance.

OBJECTIVE: MR colonography permits accurate detection of colonic polyps larger than 8 mm. Patient acceptance remains limited because of the need for bowel cleansing. The aim of this study was to develop and assess a strategy obviating colonic cleansing by performing MR colonography in conjunction with fecal tagging based on the oral administration of barium. SUBJECTS AND METHODS: Six healthy volunteers and six patients with suspected colorectal tumors, undergoing conventional colonoscopy within 1 week of MR imaging, were included in this study. For fecal tagging, 200 mL of a barium-containing contrast agent was ingested with each of four principal meals preceding the examination. For MR colonography, the colon was filled with a barium and water mixture while gadobenate dimeglumine (0.2 mmol/kg) was injected IV. RESULTS: The combination of fecal tagging and colonic filling with barium resulted in a homogeneously low signal throughout the colonic lumen in all 12 subjects. IV injection of gadolinium caused avid enhancement of the colonic wall. Similarly, lesions arising from the colonic wall enhanced avidly. In the six evaluated patients, MR colonography correctly identified two colonic carcinomas in two patients and one polyp in each of another two patients. CONCLUSION: Fecal tagging obviates bowel cleansing and should, therefore, enhance patient acceptance for MR colonoscopy. Barium used as the tagging agent is promising because it is inexpensive, commercially available, and characterized by an excellent safety profile.

Adult↗

Contrast-enhanced MR angiography in patients with aortic occlusion (Leriche syndrome).

The diagnostic utility of contrast-enhanced three-dimensional magnetic resonance angiography (3D MRA) was retrospectively evaluated in 24 patients with Leriche syndrome. 3D MRA was performed either of the abdomen alone (n = 6), the abdomen and chest (n = 2), the abdomen and lower extremities (n = 12), or of all stations (n = 4). MRA image sets were evaluated regarding the location of the aortic occlusion, the presence of concomitant occlusive disease affecting the renal and visceral arteries, the type and extent of collateralization, and the level of the most proximal graftable arterial segments. Intravenous digital subtraction angiography was available for correlation in two patients, while surgical correlation was possible in 14 patients. MRA permitted classification of the level of aortic occlusion as juxtarenal (n = 8), infrarenal, and cranial to the origin of the inferior mesenteric artery (IMA; n = 11), and infrarenal but caudad to the IMA (n = 5). Extraanatomical grafts were displayed to similar advantage as collateral parietal and visceral pathways. Contrast-enhanced 3D MRA thus appears to be well suited for assessment of patients with suspected Leriche syndrome.

Aged↗