The Niebauer-Cutter prosthesis in excision arthroplasty of the trapezium.

Sixteen patients had excision arthroplasty of the trapezium, using the Niebauer-Cutter prosthesis. The average period of postoperative follow-up was thirteen months. All patients had severe preoperative disabilities and the majority were relieved from resting pain and pain during active use of their hands. The postoperative range of motion with regard to the palmar and radial abduction was found to be satisfactory, while varying degrees of limitation of circumduction was the rule. There was no correlation between the patients' own judgment of the postoperative benefits and the objectively measured range of motion. One patient had a luxation of the prosthesis, while another had a subluxation when opposing the thumb. This frequency of luxation/subluxation seems to be less than that experienced with the other common type of prosthesis, the Swanson prosthesis. Although it is obvious that the ideal prosthesis for treatment of disabilities in the carpometacarpal joint of the thumb is still not available, it was concluded that the Niebauer-Cutter prosthesis is the best choice at the present.

Arthritis, Rheumatoid↗

Inverse relationships between coronary blood flow obstruction and platelet reactivity in stable angina pectoris.

This study investigates relationships between platelet reactivity and coronary blood flow obstruction in stable angina pectoris. Consented were 36 patients with single-vessel disease. The subjects were divided into two groups. One group (n=14) had less severe (<=80%) and the second group (n=22) had severe coronary flow impairment (90%). Before elective coronary angiography platelet in vitro reactivity in venous whole blood was determined using a flow cytometry technique. A thrombin-receptor activating peptide (TRAP-6) (0.77 and 0.06 g/l) and ADP (8.5 and 1.7 micromol/l) were used to activate platelets. The number of fibrinogen positive cells (%) i.e., activated platelets after stimulation was employed as experimental parameter. Less severe flow obstruction was associated with more reactive platelets. When stimulating with 0.77 g/l TRAP-6 the number of activated platelets was 64+/-15 (SD)%. The corresponding value for the group with severe flow obstruction was 40+/-17(SD)%. The difference is significant (P<0.001). 0.06 g/l TRAP-6 yielded similar results (P<0.01). Also when using 8.5 micromol/l ADP to challenge platelets less severe flow obstruction was associated with enhanced reactivity (P<0.01). 1.7 micromol/l ADP generated comparable results (P<0.05). Thus, in stable angina pectoris coronary flow obstruction is inversely related to platelet reactivity.

Adenosine Diphosphate↗

Inverse relationship between platelet density and reactivity alterations at coronary angiography.

This work investigates relationships between platelet density and reactivity. 21 individuals subject to coronary angiography were studied. Peak platelet density was analyzed using a newly developed electronic device. The apparatus measures light transmission through test tubes containing density-separated platelets, thus allowing an estimation of the platelet distribution in the gradient. A flow cytometry technique was used for determining platelet reactivity after stimulating with ADP. Platelet counts, mean platelet volumes, peak platelet density and platelet reactivity were determined immediately before (day 1) and 24 h after cardiac catheterization (day 2). For all parameters changes during the day of angiography were compared with platelet density alterations. The subjects were divided into two groups according to density changes at angiography. Group 1 individuals showed density alterations (i.e. day 2 - day 1 value) > or = -8 x 10(-5) kg/l. In contrast, group 2 subjects either displayed density changes < -8 x 10(-5) kg/l or grossly disturbed platelet density patterns on day 2. Before angiography both groups had similar platelet counts and volumes. Then platelet reactivity when stimulating with ADP did not differ significantly between the two groups. After angiography, the number of fibrinogen-positive cells when stimulating with ADP rose by 6 +/- 8% for group 2 patients. The corresponding figure for group 1 was -1 +/- 6%. The difference was significant (p = 0.01). No such relationships were found when comparing density alterations and changes of platelet counts and volumes. We conclude that in this study platelet density alterations at coronary angiography are inversely related to variations of platelet reactivity.

Adenosine Diphosphate↗

Radiologic findings after fundoplication compared with a pH reflux test and symptoms.

In a follow-up after fundoplication, 61 patients underwent a double contrast examination of the stomach and a radiologic examination to detect any gastro-oesophageal reflux. The radiologic findings were compared with pH reflux test and symptoms. Gastro-oesophageal reflux was found in 7 patients at radiologic examination. None of these patients had an adequate fundoplication at a double contrast examination of the stomach and all had symptoms indicating reflux. Recurrence of gastro-oesophageal reflux may be shown at the radiologic examination and predicted by the morphologic appearances at the double contrast examination.

Deglutition Disorders↗

Radiologic diagnosis of gastro-oesophageal reflux.

In 149 patients, a standardized radiologic method for the detection of gastro-oesophageal reflux was applied and compared with the results obtained at endoscopy and by a manometric reflux test. Radiologic reflux was recorded in 53 patients, of whom 25 had reflux without abdominal compression and 51 with compression. At least one of the other two types of examination disclosed pathologic conditions in all but 2 of 53 patients. Oesophagitis was significantly more severe among the patients with reflux observed at radiography. The presence of hiatal incompetence with reflux only to the hiatal hernia but not to the oesophagus was not a strong indicator of gastro-oesophageal reflux disease. Hiatal hernia was present in a significantly larger number of the patients with reflux at radiography than in those without reflux. Increased width of the hiatus gave stronger evidence for reflux disease than in patients with a normal hiatus. Thus, the width of the hiatus also had a bearing on the diagnosis of gastro-oesophageal reflux disease.

Adult↗

Radiologic diagnosis of gastro-oesophageal reflux. Comparison of barium and low-density contrast medium.

It has been proposed that the high density of ordinary barium suspensions may complicate the radiologic diagnosis of gastro-oesophageal reflux. For this reason P-contrast was developed (Ferring AB); a contrast medium with the same density as water (1 g/cm3). A comparison of P-contrast and barium (Mixobar Ventrikel 400 mg/ml) was performed in 82 patients. All patients were examined with both contrast media and the findings were compared with those at reflux test at manometry, endoscopy and 24-hour pH monitoring. Another 40 patients and 15 symptom-free controls were examined with two different amounts of barium, 100 ml and 200 ml, to study if the radiologic diagnosis of reflux varied with the volume of contrast medium administered. P-contrast was found to have no advantages over barium for the diagnosis of gastro-oesophageal reflux. The outcome of the radiologic examination was not influenced by the different volumes of barium used.

Barium↗

Radiologic diagnosis of gastro-oesophageal reflux by means of graded abdominal compression.

The aim of the study was to ascertain whether abdominal compression by a standardized technique increases the reliability of the radiologic diagnosis of gastro-oesophageal reflux. Eighty-eight patients were examined by means of a manometric reflux test, 24-hour measurements of pH and endoscopy. The radiologic examination was performed with and without graded abdominal compression, the patient at the same time turning from side to side. When abdominal compression was included the result of the radiologic examination was positive in 31 patients. In the absence of abdominal compression reflux was detected in 11 of these patients. In one patient reflux was detected only without compression. All these 31 patients had one more test positive and in 27 at least 2 more tests were positive. Another 21 patients had reflux disease as indicated by at least 2 of the 3 other tests. The compression technique seems to yield no false positive responses, and proved to be significantly more reliable than examinations without compression.

Abdomen↗