Tricuspid valve replacement with the St. Jude Medical valve: 19 years of experience.

OBJECTIVE: The choice of the valve substitute in the tricuspid position remains controversial. A St. Jude Medical valve is a choice of valve substitute and its lower thrombogenicity and excellent hemodynamic performance have been reported even in the tricuspid position. However, little is known of the long-term durability of the St. Jude Medical valve in the tricuspid position. Our long-term experience of tricuspid valve replacement showed the higher thrombogenicity than we had expected, therefore, this study was done to reconsider our strategy for valve choice. METHODS: This study reviewed 23 patient who underwent 25 tricuspid valve replacements with the St. Jude Medical valves from 1980 to 1997. The mean age was 40 years. Eleven patients (48%) were men. There were four in-hospital deaths (17%). The remaining 19 patients were all alive and followed from 2.2 to 19.0 years (mean 11.8 years). RESULTS: The overall survival, including hospital mortality, was 83%, 10 and 15 years after surgery. Valve thrombosis occurred in six patients. Freedom from valve thrombosis was 78 and 70%, 10 and 15 years after surgery, respectively. The linearized rate of the valve thrombosis was 2.9%/patient-years. Six patients required reoperation. The mean interval to reoperation was 9.5 years. Freedom from reoperation was 83% and 75%, 10 and 15 years after surgery, respectively. The linearized rate of the reoperation was 2.8%/patient-years. No structural valve deterioration was found. Echocardiographic study showed that the function of the St. Jude Medical valve without valve-related complications was well maintained. CONCLUSIONS: The higher thrombogenicity of the St. Jude Medical valve in the tricuspid position altered our choice of valve substitutes from the St. Jude Medical valve to a bioprosthesis which is lack of need for anticoagulant therapy except for juvenile patients who are able to maintain potent anticoagulant therapy.

Adolescent↗

Cerebral tissue oxygen saturation during percutaneous cardiopulmonary support in a canine model of respiratory failure.

Percutaneous cardiopulmonary support (PCPS) has come to be applied for cardiopulmonary resuscitation and in the management of severe respiratory failure as well as severe heart failure. We investigated cerebral tissue oxygen saturation during PCPS in a canine model of respiratory failure using near-infrared spectroscopy. Animals were mechanically ventilated with 10% oxygen to make a respiratory failure model. Perfusion with PCPS was performed via the left femoral artery and switched to that via the right axillary artery. Cerebral tissue oxygen saturation was 54.2 +/- 3.4% during PCPS via the femoral artery and was 82.3 +/- 4.6% during PCPS via the axillary artery (p = 0.001). Hepatic tissue oxygen saturation was not significantly different. LV dP/dt max increased significantly after switching to the axillary blood supply (p = 0.001). Conventional PCPS may not have the capability of supporting cerebral circulation under severe respiratory failure without organic heart disease.

Analysis of Variance↗

Eccentric roller type total artificial heart creating interatrial shunt.

Creating an interatrial shunt to achieve left-right flow balance and modification of the blood chambers to improve the basic performance of the device were performed in developing an eccentric roller type total artificial heart (ERTAH). Smaller blood chambers reduce friction loss and increase durability and energy efficiency. We changed the left blood chamber volume of 60 ml to 40 ml and the right blood chamber volume of 53 ml to 35 ml compared with previous types. Designs of inlet and outlet ports were modified to prevent backflow. In the mock circulatory system, redesigning the blood chambers resulted in a 20% increase in energy efficiency, about a two-fold increase of cardiac output and improved durability compared to the previous type. In an animal experiment, the ERTAH operated at a driving rate of 160 rpm with a left flow rate of 6.0 L/min and a right flow rate of 5.4 L/min. Interatrial shunt flow rate was 250-400 ml/min.

Animals↗

Biocompatibility of heparin-coated extracorporeal bypass circuits: new heparin bonded bioline system.

Biocompatibility of a new type of heparin-coated cardiopulmonary bypass equipment, the Bioline, was evaluated in coronary artery bypass surgery cases. The heparin-coated (H) group (n = 15; Quadrox Bioline oxygenator/reservior and Carmeda BioMedicus BP-80 centrifugal pump) was compared with the nonheparin-coated (N) group (n = 12; uncoated, otherwise similar oxygenator, centrifugal pump, tubing, and filter set). Both groups used full systemic heparinization. The peak values of neutrophil elastase, C3a, IL-6, and IL-8 at 2 h after cardiopulmonary bypass (CPB), and C3a levels at the end of CPB and at 2 h after CPB were significantly reduced in the H group compared with those of the N group. However, no statistically significant intergroup differences were observed in thrombin-antithrombin complex, D-dimer, beta-thromboglobulin, or platelet factor-4. No significant differences were observed in hemostasis time, postoperative 12 h blood loss, required amount of blood transfusion, or intubation time. In conclusion, the Bioline demonstrated partially improved biocompatibility, in terms of leukocyte and complement activation, and proinflammatory cytokine production. However, it did not improve platelet activation, coagulation, or fibrinolysis cascade under full systemic heparinization. As a result, the clinical beneficial impact seemed to be the minimum.

Aged↗

Obstruction of St Jude Medical valves in the aortic position: significance of a combination of cineradiography and echocardiography.

BACKGROUND: Obstruction of the St Jude Medical valve (St Jude Medical, Inc, St Paul, Minn) is a rare but serious complication. METHODS: Cineradiographic and echocardiographic evaluations of aortic St Jude Medical valves were simultaneously performed on 54 patients, with no signs of prosthetic valve dysfunction late after surgery. RESULTS: Although closing angles of the leaflets corresponded closely with the manufacturer data, restricted opening of the leaflets (opening angle >/= 20 degrees ) was found in 16 (group D) of the 54 patients by means of cineradiography. The opening angles were equal to or less than 14 degrees in the other 23 patients (group N) and between 15 degrees and 19 degrees in the remaining 15 (group M). Doppler-derived transprosthetic pressure gradients were significantly higher (P =.03) and the velocity index was significantly lower (P =.003) in group D than in group N. However, no significant differences were found in those values between group N and group M. Replacement of the aortic St Jude Medical valves was performed in 5 of the 16 patients, and the remaining 11 have been followed up because of relatively low pressure gradients. The cause of restricted leaflet movement was pannus formation without thrombosis in 4 patients and valve thrombosis with pannus formation in one. CONCLUSIONS: Reduced valve orifice area and restricted opening of the leaflets resulting from excess growth of pannus probably led to obstruction of the aortic St Jude Medical valves. A combination of cineradiography and echocardiography makes it possible to provide an accurate and detailed diagnosis of obstruction of the valve.

Adolescent↗

Plasma exchange for hyperbilirubinemia following implantation of a left ventricle assist system: a case report.

A 49-year-old patient with end-stage dilated cardiomyopathy underwent implantation of a left ventricular assist system (LVAS). Although the systemic circulation seemed to be improved, the serum total bilirubin (Tbili) level increased sharply in the early postoperative period (preoperative Tbili, 5.7 mg/dl; postoperative day 3, 33.6 mg/dl). Plasma exchange (PE) was performed 7 times from postoperative day 4, and the Tbili level decreased to 16.3 mg/dl by postoperative day 11. Thereafter, serum Tbili normalized concomitant with improved circulatory condition. The cause of the hyperbilirubinemia was considered to be temporary right ventricular dysfunction or hepatic sinusoid endothelial dysfunction. The liver function was recoverable, so PE had been effective in this case. Unfortunately, the patient suffered a midbrain infarction and ultimately died. From this experience, PE is recommended if it is judged that liver function can be preserved and circulation is adequate, but its implementation should not be delayed. It is essential that LVAS is implanted before damage occurs to end-organ function and thus prevent hyperbilirubinemia.

Cardiomyopathy, Dilated↗

[Hemodynamic assessment of the Carpentier-Edwards pericardial valve compared with the St. Jude Medical valve in the aortic position using dobutamine-stress echocardiography].

To assess the hemodynamic performance of the prosthetic valve in the aortic position, we examined dobutamine-stress echocardiography (DSE) to the patients underwent AVR with CEP valve or SJM valve. In 23 mm size, there were no significant differences between CEP group and SJM group in Peak velocity of the aortic jet (PV), peak pressure gradient (PPG) and effective orifice area (EOA). On the other hand, in 21 mm size, PV and PPG of the CEP group were significantly lower than those of the SJM group after DSE. The EOA of the CEP group was significantly larger than that of the SJM group after DSE. Our results suggest that the hemodynamic function of the CEP valve is superior to that of the SJM valve especially in small aortic annuli.

Aged↗

Newly designed eccentric roller type total artificial heart.

We have produced an eccentric roller type total artificial heart (ERTAH). As the first step in the development of this ERTAH, we conducted simulations such as a numerical simulation, a mock test, and an acute animal experiment using DeBakey roller pumps to analyze the left-right balance during its operation. The next step was redesigning the blood chambers to improve energy efficiency and implanting the ERTAH with an interatrial shunt into an animal for evaluation of the in vivo performance of the device. In the simulations, shunt flow through the bronchial arteries was approximately 500-600 ml/min, and the interatrial resistance was varied from 2.9-7.7 mmHg.min/liter. Redesigning the blood chambers resulted in the mock test in a 20% increase in energy efficiency, about a two-fold increase in cardiac output and improved durability compared to the previous type in the mock test. In the animal experiment the ERTAH operated with a left flow rate of 6.0 liters/min and a right flow rate of 5.4 liters/min. The interatrial shunt flow rate was 250-400 ml/min. Creating an interatrial shunt is a useful method for balancing the blood flow between the left and right heart of the ERTAH. A decrease in friction resistance and the prevention of backward flow resulted in an increase in energy efficiency, cardiac output, and improved durability, in spite of downsizing the blood chambers.

Animals↗

A case report of surgical treatment of quadricuspid aortic valve associated with regurgitation.

A case of a 65-year-old woman who had a quadricuspid aortic valve associated with aortic regurgitation is reported. The patient had severe aortic regurgitation and four equally divided aortic cusps. The valve abnormality was detected by a transesophageal echo and an aortography. The incomplete aortic valve was excised and replaced by a St. Jude Medical prosthesis. Although this case had no coronary abnormality, a coronary displacement is often reported in quadricuspid aortic valve cases. In order to perform an operation safely, accurate information which is obtained by a non-invasive examination of the transesoph-ageal echo is quite valuable as it can indicate the need for further preoperative examinations of the coronary arteries.

Aged↗

ATS prosthetic valve motion: an in vitro analysis.

BACKGROUND AND AIM OF THE STUDY: We have reported clinical findings that normally functioning open pivot ATS valves did not open completely. In order to analyze features of the ATS valve motion more precisely, in vitro tests were conducted. METHODS: Opening angles and pressure gradients of the ATS valve were measured and compared with those of the St. Jude Medical (SJM) valve under steady flow, but with various outlet configurations. Second, opening angles of the two valves were measured under pulsatile conditions in two different outflow configurations: (i) a 'straight outlet' where the leaflets did not extend into the tapering outflow chamber, and (ii) an 'abrupt enlargement outlet' where the leaflets extended directly into the enlarged outflow space. Third, flow visualization studies were made under steady flow conditions in the straight and abrupt enlargement outlet conduits, respectively. RESULTS: Under steady flow conditions, opening of the ATS valve was restricted in most outflow configurations; only when the outlet angle was 0 degrees did the valve open fully. The SJM valve opened completely in all downstream configurations. Despite restricted opening in the ATS valve, the pressure gradient was similar in both valves. Under pulsatile conditions, both valves opened fully in the straight outlet; however, in the abrupt enlargement outlet the ATS valve opened incompletely and the SJM valve completely. Substantial turbulent flow was observed at the outside of the leaflet and corners of the conduit, notably with the ATS valve. CONCLUSION: This study showed that the ATS valve did not open fully except when the outflow was straight, and the leaflet did not extend into an enlarged downstream chamber. Structural features of the ATS, such as its axis being located close to the straight edge and its leaflets extending further downstream from the ring orifice, may cause this unique valve behavior.

Heart Valve Prosthesis↗

Concentric wear of the Delrin disc in a Bjork-Shiley heart valve prosthesis: report of two cases.

We report herein the cases of two patients who received replacement of aortic Bjork-Shiley Delrin (BSD) valves that had been implanted for over 20 years following the development of aortic regurgitation (AR) resulting from wear of a Delrin disc. Case 1 was a 61-year-old woman in whom echocardiography revealed marked left ventricular dilatation and moderate AR 23 years after an aortic valve replacement (AVR) with a 21-mm BSD valve. Case 2 was a 51-year-old woman in whom echocardiography revealed marked dilation of the right atrium and moderate AR 23 years and 8 months after an AVR with a 21-mm BSD valve, as well as a mitral valve replacement with a 3M Starr-Edwards (SE) ball valve and tricuspid annuloplasty. In both patients, the BSD valves were replaced with other mechanical valves at reoperation. Examination of the explanted BSD valves showed that the Delrin discs contained increases in the radial gaps and strut indentation grooves on the inflow and outflow surfaces. The type and magnitude of the wear on the Delrin discs in these valves were consistent with data reported in the literature for this valve design after similar implant duration.

Aortic Valve↗

The use of gelatin-resorcin-formalin glue in acute aortic dissection type A.

OBJECTIVES: The Gelatin-resorcin-formalin (GRF) glue is widely used in the surgical treatment of dissecting aneurysms. This paper is focused on our experience with the GRF glue in cases, operated for acute aortic dissection type A. METHODS: Between September 1990 and December 1997, 164 patients were operated on for acute aortic dissection type A. In 148 patients GRF was used to reinforce the dissected layers proximal (n = 106) or distal (n = 144) of the grafted aortic segment. An intervention at the aortic valve was necessary in 93 instances. In 111 patients, an open distal anastomosis for replacement of the proximal aortic arch was performed. Thirty-seven additional patients underwent subtotal or total aortic arch replacement. RESULTS: Early postoperative mortality was 26.2% (43/164 patients). Another 16 patients died late postoperatively. Actuarial survival rates are 69.9% at 1 year, 62.5% at 3 years, 59.4% at 5 years and 56.1% at 7 years, post-operatively. Twenty-two reoperations were performed in 20 patients (16.5%). Nine of these patients had developed complications in aortic segments that underwent reconstruction by use of GRF during the primary intervention. Aortic root redissection was found in 7/9 patients intraoperatively, whereas 1/9 patients presented with a rupture near the distal graft to aortic anastomosis. CONCLUSIONS: The introduction of GRF glue has greatly facilitated the reconstruction of dissected aortic wall layers adjacent to the vascular graft. However, the use of the adhesive for aortic root reconstruction in acute aortic dissection type A may bear a significant risk of late postoperative proximal aortic redissection. Complications associated with the GRF glue are likely to be due to the toxic effects of the formalin component. Therefore, care should be taken that the amount of formalin administered to the glue components remains as low as possible.

Acute Disease↗

Recovery from lymphocytopenia following extracorporeal circulation: simple indicator to assess surgical stress.

This study investigated whether the lymphocyte count is a useful indicator to assess surgical damage following extracorporeal bypass. In Study 1, to investigate the correlation between extracorporeal circulating time (ECCT) and lymphocyte counts, 40 elective CABG patients were studied retrospectively. The lymphocyte recovery ratio (LRR), which represented the actual lymphocyte count divided by the preoperative lymphocyte count, was determined preoperatively, and on postoperative day (POD) 1, POD 3, and POD 5. In Study 2, the correlation between the interleukin-8 (IL-8) level and LRR was examined prospectively in elective CABG patients (n = 20). We measured the LRR and serum IL-8 levels preoperatively and during extracorporeal circulation (ECC) at 5 min, at the end of ECC, and 1, 3, and 12 h following ECC termination. Study 1 showed that the LRR decreased until POD 1 and gradually increased thereafter. The LRR had a negative correlation with the ECCT. In Study 2, the IL-8 level demonstrated a time course opposite to that of the LRR; it increased until 3 h after ECC termination and declined thereafter. There was a significant negative correlation between the LRR on POD 3 and the IL-8 level at 3 h after ECC termination. In summary, long-term ECC induced significant and prolonged lymphocytopenia. The LRR had a negative correlation with IL-8. These results indicated that the LRR may represent the degree of surgical stress following ECC; therefore, the counting of lymphocytes can be a quite useful bedside monitor to assess surgical damage and prognosis.

Coronary Artery Bypass↗

Flow balance between the left and right cardiac output of an eccentric roller type total artificial heart.

We have made an eccentric roller type total artificial heart (ERTAH). The ERTAH is a positive-displacement device comparable to a DeBakey roller pump. Its left and right outputs are determined by the size of its blood chambers, and the ratio of its left and right output is almost constant. We focused on an interatrial shunt to achieve left-right balance. We have conducted numerical simulation, a mock test, and an acute animal experiment to analyze left-right heart balance during ERTAH operation. Numerical simulation was performed under conditions in which the flow of the left artificial heart was fixed at 6 L/min, the flow of the right artificial heart was varied from 4.8 to 6 L/min, and the interatrial resistance was also varied. The relationship between the interatrial shunt flow rate and the output of the left and right artificial hearts was balanced when the flow of the right artificial heart was at 5.45 L/min. In a mock test, 2 DeBakey roller pumps were connected to the left and right sides of a Donovan mock circulatory system, and an interatrial shunt was created between the inlet ports of the left and right roller pumps. The interatrial resistance of the mock system was varied from 7.7, to 4.3, and to 2.9 mm Hg x min/L when the inner diameter of the interatrial shunt was 6, 8, and 10 mm, respectively. As in the mock test, 2 roller pumps were used to bypass the right and left hearts of a goat weighing 60 kg. The flow rate of the left heart was almost constant (4.7 L/min). The flow of the right heart was approximately 4.1 L/min when the interatrial shunt flow rate was zero. A leading consideration was that the left to left shunt through the bronchial arteries in this goat was approximately 0.6 L/min. In developing the ERTAH, we considered that creating an interatrial shunt between the inlet ports of the ERTAH as well as making a difference between the chamber volumes might be effective in balancing the left-right sides of the artificial heart.

Animals↗

Surgical treatment of a coronary artery fistula with concomitant saccular coronary artery aneurysm: a case report.

An extremely rare case of a coronary artery fistula with a concomitant saccular aneurysm is presented. A 65-year-old woman, who had a history of chest bruising 5 years earlier, suffered from chest pain, which was diagnosed as being due to left coronary artery-pulmonary artery fistulae concomitant with a giant saccular coronary artery aneurysm. Suture closure of the afferent coronary artery to the aneurysm, aneurysmorrhaphy, and transpulmonary closure of coronary artery-pulmonary artery fistulae were performed. The postoperative course was uneventful and the patient was well at 3 months after the operation. Because the risk of surgery appears to be less than the potential development of fatal complications, it is recommended for the treatment of coronary artery fistula with a concomitant saccular aneurysm.

Aged↗

Aortic valve replacement for aortic regurgitation caused by aortitis.

Between January 1984 and December 1998, 19 patients (16 with Takayasu's arteritis, 3 with non-Takayasu's aortitis) underwent surgical treatment for aortic regurgitation resulting from the aortitis. Of the 19 patients, 14 had aortic valve replacement (AVR) and 5 had aortic root replacement. One patient (5.3%) died of graft infection during the hospital stay. During the follow-up period, 1 (5.6%) of the 18 postoperative patients died of paravalvular leakage due to valve detachment, which also required redo-operations in 2 patients with non-Takayasu's aortitis. Both patients were operated on during the active phase of the inflammation without perioperative steroid therapy. Although transmural pledgeted sutures were used for replacement of the detached prosthetic valve in 1 of these 2 patients, disruption of the aortic wall resulted in recurrence of valve detachment. In the other patient, aortic root replacement was successfully performed with the Cabrol technique in the second operation. Perioperaitve steroid therapy plays an important role in preventing complications after AVR when the valve replacement is carried out during the active phase of the inflammation, and for patients with non-Takayasu's aortitis, aortic root replacement should be considered to reduce the tension on the suture line and the native aortic valve annulus.

Adult↗

MR findings in degenerated ovarian leiomyoma.

Leiomyoma is one of the rarest solid tumours of the ovary. We report a case of a degenerated ovarian leiomyoma associated with pregnancy. MR findings are identical to those of degenerated uterine leiomyoma and it is difficult to differentiate between them. Ovarian leiomyoma should therefore be included in the differential diagnosis of subserosal uterine leiomyoma.

Adult↗

Protective effects of pretreatment with ginsenosides on cardiac and coronary vascular function after hypothermic rat heart preservation.

Prevention of cardiac and vascular dysfunction with pretreatment has been accepted as an important factor in heart transplantation. Ginsenosides (GS) have been reported to have some beneficial effects on the cardiac and vascular system. We hypothesized that pretreatment with GS would result in an improvement of functional recovery after a 12 hour (hr) rat heart preservation. A Langendorff apparatus was applied to estimate the cardiac and vascular function in an isolated rat heart preparation. The hearts were preserved in University of Wisconsin solution at 0 degree C for 12 hr, after pretreatment with 0.9% sodium chloride or GS 100 mg/kg, respectively, in control (n = 9) and GS (n = 14) groups. After storage, the cardiac function, myocardial water content, and coronary vasodilatory response were evaluated. The GS group showed a significantly higher recovery percentage of cardiac function compared with the control group: aortic flow 81.4 +/- 21.4% versus 57.2 +/- 11.0% (p = 0.0052); coronary flow 81.4 +/- 14.5% versus 57.2 +/- 6.0% (p = 0.0001); +/- dp/dt max 72.5 +/- 16.1% and 66.0 +/- 16.1% versus 53.7 +/- 4.1% and 51.4 +/- 7.1% (p = 0.0027 and p = 0.0189) respectively. The GS group showed a lower increase in myocardial water content. With Langendorff perfusion, the endothelial and vascular smooth-muscle cell function were evaluated by an increasing percentage of coronary flow in response to acetylcholine chloride (0.3 x 10(-7) mol/liter) and nitroglycerin (0.5 x 10(-5) mol/liter). It was significantly higher in the GS group than that in the control group (19.2 +/- 8.8% and 28.0 +/- 14.1% versus 9.9 +/- 4.7% and 14.7 +/- 8.1%, p = 0.008 and p = 0.0187, respectively) at the first minute. These results suggest a protective effect on ventricular and coronary vascular function in the rats pretreated with Ginsenosides, indicating potential benefits for long-term heart preservation.

Animals↗