Search PubMed⌕ Search

Biomedical subjects

S Fanconi

Publications and source records attributed to S Fanconi.

At least 73 records · Page 4Linked to original sources

[Pediatric emergencies].

We describe the most frequent emergencies in pediatrics and discuss their differential diagnosis and therapy. Dyspnea, shock, coma, convulsions, infectious CNS affections, head injury and burns are reported in detail. The importance of correct diagnosis and correct clinical assessment is emphasized, as they influence therapy and further management of the patients.

Brain Diseases↗

[The collecting principle in pediatrics and neonatology].

Quality medical care during transport of critically ill pediatric and neonatal patients is only possible if the referring hospital and the regional center cooperate closely. The experience of physicians and nurses involved is of great importance, and the choice of the transporting team should depend on the medical status of the patient and the skills of the physicians and nurses or paramedics. Critically ill children and neonates should be transported by specialized teams. Our statistics from the last 12 years show an increasing number of transports, with the majority of patients being referred from peripheral hospitals.

Child↗

Three cases of neonatal herpes simplex virus infection presenting as fulminant hepatitis.

We report three cases of neonatal herpes simplex virus (HSV) infection presenting as fulminant hepatitis. None of the patients had clear risk factors for HSV infection and they all died. Antiviral treatment for HSV is currently available but must be administered early in the course of the disease before irreversible liver tissue damage is present. Since the diagnosis may be difficult to establish, we wish to draw the attention of clinicians to the presentation of neonatal HSV infection and suggest that in such cases viral cultures, including culture of liver tissue, should be obtained early and antiviral treatment administered while awaiting the culture results.

Acute Disease↗

Transcutaneous carbon dioxide pressure for monitoring patients with severe croup.

In a prospective investigation of 17 children with severe croup, we analyzed the effect of epinephrine inhalations and mild sedation with chloral hydrate on transcutaneous carbon dioxide pressure (tcPCO2), pulse oximetry measurements, and croup scores. There was a highly significant reduction (p less than 0.001) in the tcPCO2 values and croup scores after inhalation of epinephrine. The changes in the tcPCO2 values correlated with the clinical findings. Mild sedation also significantly improved the croup scores but failed to influence the tcPCO2 values. There was not statistically significant difference in pulse oximetry saturation, fraction of administered oxygen, heart rate, or respiratory rate before and after inhalation of epinephrine or chloral hydrate administration. Monitoring tcPCO2 appears to be a reliable and objective tool for managing patients with upper airway obstruction, whereas croup scores may be misleading.

Blood Gas Monitoring, Transcutaneous↗

Pulse oximetry for hypoxemia: a warning to users and manufacturers.

Pulse oximetry represents a major advance in patient monitoring, but measurement below 70 to 80% saturation has important limitations. Several authors have tested pulse oximetry at low saturations with conflicting results. A review of these data indicates that every patient with a pulse oximeter value below 75 to 80% SaO2 should have one or more invasive measurements of the arterial SaO2 in order to avoid undetected severe hypoxemia.

Animals↗

Hyperoxemia in newborn infants: detection by pulse oximetry.

Pulse oximetry has been proposed as a noninvasive continuous method for transcutaneous monitoring of arterial oxygen saturation of hemoglobin (tcSO2) in the newborn infant. The reliability of this technique in detecting hyperoxemia is controversial, because small changes in saturation greater than 90% are associated with relatively large changes in arterial oxygen tension (PaO2). The purpose of this study was to assess the reliability of pulse oximetry using an alarm limit of 95% tcSO2 in detecting hyperoxemia (defined as PaO2 greater than 90 mm Hg) and to examine the effect of varying the alarm limit on reliability. Two types of pulse oximeter were studied alternately in 50 newborn infants who were mechanically ventilated with indwelling arterial lines. Three arterial blood samples were drawn from every infant during routine increase of inspired oxygen before intratracheal suction, and PaO2 was compared with tcSO2. The Nellcor N-100 pulse oximeter identified all 26 hyperoxemic instances correctly (sensitivity 100%) and alarmed falsely in 25 of 49 nonhyperoxemic instances (specificity 49%). The Ohmeda Biox 3700 pulse oximeter detected 13 of 35 hyperoxemic instances (sensitivity 37%) and alarmed falsely in 7 of 40 nonhyperoxemic instances (specificity 83%). The optimal alarm limit, defined as a sensitivity of 95% or more associated with maximal specificity, was determined for Nellcor N-100 at 96% tcSO2 (specificity 38%) and for Ohmeda Biox 3700 at 89% tcSO2 (specificity 52%). It was concluded that pulse oximeters can be highly sensitive in detecting hyperoxemia provided that type-specific alarm limits are set and a low specificity is accepted.

Blood Gas Analysis↗

[Cerebral problems in pediatric intensive care].

This paper presents a review of different methods enabling the monitoring of cerebral function in neonatal and paediatric intensive care. EEG, evoked potentials, conventional radiological studies, computerized tomography, ultrasound, intracranial pressure measurements, nuclear magnetic resonance, Doppler ultrasound, radioisotope studies, angiography, infra-red spectral analysis and last, but not least, clinical examination produce information regarding the neurological state of the patient which must be critically analysed in order to ensure optimal management of the case. Unfortunately, and in spite of impressive progress in non-invasive monitoring of the cerebral function, we are still forced to make important medical and ethical decisions without precise information about the neurological state of our patients.

Brain Damage, Chronic↗

Dexamethasone therapy and endogenous cortisol production in severe pediatric head injury.

A prospective randomised study was performed on 25 children aged 1.4 to 15.8 years with severe head injury (Glasgow Coma Scale less than or equal to 7) to determine the clinical effectiveness and the impact on endogenous cortisol production of high-dose steroid therapy. Thirteen patients (group 1) received dexamethasone 1 mg/kg/day during the first 3 days and 12 (group 2) not. All patients were treated with a standardized regimen. Urinary free cortisol was measured by radioimmunoassay, and the clinical data were recorded at hourly intervals. Outcome was assessed 6 months later using the Glasgow Outcome Scale. We found a higher frequency of bacterial pneumonias in the dexamethasone-treated patients (7/13 versus 2/12). Group 1 showed a suppression of endogenous cortisol production from day 1 to day 6. In group 2, mean free cortisol was up to 5-fold higher than under basal conditions. The results in group 2 showed that the endogenous steroid production reacts adequately to the stress of severe head injury. It probably is sufficient to elicit maximum glucocorticoid effects. There was no other statistically significant difference in the clinical and laboratory data between the two groups. We conclude that dexamethasone in high doses suppresses endogenous cortisol production up to 6 days and may increase the risk of bacterial infection without affecting the outcome or the clinical and laboratory data.

Adolescent↗

Transcutaneous carbon dioxide and oxygen tension in newborn infants: reliability of a combined monitor of oxygen tension and carbon dioxide tension.

We evaluated a new combined sensor for monitoring transcutaneous carbon dioxide tension (PtcCO2) and oxygen tension (PtcO2) in 20 critically ill newborn infants. Arterial oxygen tension (PaO2) ranged from 16 to 126 torr and arterial carbon dioxide tension (PaCO2) from 14 to 72 torr. Linear correlation analysis (100 paired values) of PtcO2 versus PaO2 showed an r value of 0.75 with a regression equation of PtcO2 = 8.59 + 0.905 (PaO2), while PtcCO2 versus PaCO2 revealed a correlation coefficient of r = 0.89 with an equation of PtcCO2 = 2.53 + 1.06 (PaCO2). The bias between PaO2 and PtcO2 was -2.8 with a precision of +/- 16.0 torr (range, -87 to +48 torr). The bias between PaCO2 and PtcCO2 was -5.1 with a precision of +/- 7.3 torr (range, -34 to +8 torr). The transcutaneous sensor detected 83% of hypoxia (PaO2 less than 45 torr), 75% of hyperoxia (PaO2 greater than 90 torr), 45% of hypocapnia (PaCO2 less than 35 torr), and 96% of hypercapnia (PaCO2 greater than 45 torr). We conclude that the reliability of the combined transcutaneous PO2 and PCO2 monitor in sick neonates is good for detecting hypercapnia, fair for hypoxia and hyperoxia, but poor for hypocapnia. It is an improvement in that it spares available skin surface and requires less handling, but it appears to be slightly less accurate than the single electrodes.

Blood Gas Monitoring, Transcutaneous↗

Pulse oximetry and transcutaneous oxygen tension for detection of hypoxemia in critically ill infants and children.

We tested the performance of transcutaneous oxygen monitoring (TcPO2) and pulse oximetry (tcSaO2) in detecting hypoxia in critically ill neonatal and pediatric patients. In 54 patients (178 data sets) with a mean age of 2.4 years (range 1 to 19 years), arterial saturation (SaO2) ranged from 9.5 to 100%, and arterial oxygen tension (PaO2) from 16.4 to 128 mmHg. Linear correlation analysis of pulse oximetry vs measured SaO2 revealed an r value of 0.95 (p less than 0.001) with an equation of y = 21.1 + 0.749x, while PaO2 vs tcPO2 showed a correlation coefficient of r = 0.95 (p less than 0.001) with an equation of y = -1.04 + 0.876x. The mean difference between measured SaO2 and tcSaO2 was -2.74 +/- 7.69% (range +14 to - 29%) and the mean difference between PaO2 and tcPO2 was +7.43 +/- 8.57 mmHg (range -14 to +49 mmHg). Pulse oximetry was reliable at values above 65%, but was inaccurate and overestimated the arterial SaO2 at lower values. TcPO2 tended to underestimate the arterial value with increasing PaO2. Pulse oximetry had the best sensitivity to specificity ratio for hypoxia between 65 and 90% SaO2; for tcPO2 the best results were obtained between 35 and 55 mmHg PaO2.

Adolescent↗

Is pulse oximetry reliable in detecting hyperoxemia in the neonate?

We tested the hypothesis that hyperoxemia defined as arterial PO2 above 12 kPa can be detected by pulse oximetry using 95% oxygen saturation as the upper limit. Thirty artificially ventilated neonates with an indwelling arterial catheter were studied registrating transcutaneous oxygen saturation (Ohmeda Biox 3700 Pulse Oximeter) and transcutaneous PO2 continuously during a 4-hour period and measuring arterial oxygen saturation and PO2 intermittently. 46 episodes of arterial hyperoxemia were observed. Pulse oximetry had a sensitivity of 30%, detecting 14 of these 46 hyperoxemic episodes, and a specificity of 93%. The accuracy for separating hyperoxemia from normoxemia by pulse oximetry could be improved by shifting the cut-off point from 95% to 92%. With this optimal cut-off point sensitivity was 70% and specificity 62%. We conclude that pulse oximetry is not reliable for detection of hyperoxemia.

Blood Gas Monitoring, Transcutaneous↗

Dexamethasone therapy and cortisol excretion in severe pediatric head injury.

Glucocorticoids are used in an attempt to reduce brain edema secondary to head injury. Nevertheless, their usefulness remains uncertain and contradictory. In a randomized study of 24 children with severe head injury, urinary free cortisol was measured by radioimmunoassay. Twelve patients (group 1) received dexamethasone and 12 (group 2) did not. All patients were treated with a standardized regimen. In group 1 there was complete suppression of endogenous cortisol production. In group 2 free cortisol was up to 20-fold higher than under basal conditions and reached maximum values on days 1-3. Since the excretion of cortisol in urine reflects the production rate closely and is not influenced by liver function and barbiturates, the results in group 2 show that the endogenous production of steroids is an adequate reaction to severe head injury. Exogenous glucocorticoids are thus unlikely to have any more beneficial effects than endogenous cortisol.

Adolescent↗

Intratracheal suctioning in sick preterm infants: prevention of intracranial hypertension and cerebral hypoperfusion by muscle paralysis.

In a prospective nonrandomized study, using each baby as his or her own control, we compared intracranial pressure (anterior fontanel pressure as measured with the Digilab pneumotonometer), cerebral perfusion pressure, BP, heart rate, transcutaneous Po2, and transcutaneous Pco2 before, during, and after endotracheal suctioning, with and without muscle paralysis, in 28 critically ill preterm infants with respiratory distress syndrome. With suctioning, there was a small but significant increase in intracranial pressure in paralyzed patients (from 13.7 [mean] +/- 4.4 mm Hg [SD] to 15.8 +/- 5.2 mm Hg) but a significantly larger (P less than .001) increase when they were not paralyzed (from 12.5 +/- 3.6 to 28.5 +/- 8.3 mm Hg). Suctioning led to a slight increase in BP with (from 45.3 +/- 9.1 to 48.0 +/- 8.7 mm Hg) and without muscle paralysis (from 45.1 +/- 9.4 to 50.0 +/- 11.7 mm Hg); but there was no significant difference between the two groups. The cerebral perfusion pressure in paralyzed infants did not show any significant change before, during, and after suctioning (31.5 +/- 9.1 mm Hg before v 32.0 +/- 8.7 mm Hg during suctioning), but without muscle paralysis cerebral perfusion pressure decreased (P less than .001) from 32.8 +/- 9.7 to 21.3 +/- 13.1 mm Hg. Suctioning induced a slight decrease in mean heart rate and transcutaneous Po2, but pancuronium did not alter these changes. There was no statistical difference in transcutaneous Pco2 before, during, and after suctioning with and without muscle paralysis.(ABSTRACT TRUNCATED AT 250 WORDS)

Blood Gas Monitoring, Transcutaneous↗

Kenny syndrome: evidence for idiopathic hypoparathyroidism in two patients and for abnormal parathyroid hormone in one.

We report three unrelated patients with Kenny syndrome. Clinical symptoms included severe dwarfism, with internal cortical thickening and medullary stenosis of the tubular bones, normal bone age, macrocephaly, absent diploic space, delayed closure of the anterior fontanel, and normal intelligence; two of the patients had hyperopia and papillary edema. The patients also had episodic hypocalcemic tetany and low serum levels of magnesium. In two patients the diagnosis of idiopathic hypoparathyroidism was established on the basis of undetectable serum parathyroid hormone (PTH) levels (N- and C-terminal RIAs); one of these had normal urinary cyclic adenosine monophosphate (cAMP) response to exogenous PTH. Circulating calcitonin was undetectable in either patient. In a third patient, who had abnormal body proportions, serum levels of PTH were increased in an RIA detecting predominantly intact PTH (N-RIA) and undetectable in another RIA recognizing carboxy-terminal fragments (C-RIA). Administration of PTH promptly increased urinary cAMP excretion. In this patient, serum levels of calcitonin were increased, whereas values for 25-OHD and 1,25(OH)2D were normal.

Abnormalities, Multiple↗