Search PubMed⌕ Search

Biomedical subjects

S F Stewart

Publications and source records attributed to S F Stewart.

31 records · Page 2Linked to original sources

Increase of rat serum prolactin by adenosine analogs and their blockade by the methylxanthine aminophylline.

The administration of the stable adenosine analogs N6-[(R)-methyl-2-phenylethyl]adenosine (R-PIA; 0.01-1.0 mg/kg i.p.) and 1-(6-amino-9H-purin-9-yl)-1-deoxy-N-ethyl-beta-D-ribofuronamide (NECA; 0.01-1.0 mg/kg i.p.) caused a dose-related (NECA) or biphasic (R-PIA) increases in rat serum prolactin. The S-isomer of PIA was inactive up to 4 mg/kg i.p. The methylxanthine aminophylline (10 and 30 mg/kg i.p.) antagonized the R-PIA- and NECA-induced elevation of prolactin suggesting an adenosine receptor-mediated effect. The dopaminergic agents L-dopa and bromocriptine antagonized the R-PIA and NECA-induced increase in serum prolactin. Haloperidol (a dopamine antagonist) and alpha-methyl-p-tyrosine (a catecholamine synthesis inhibitor) potentiated the R-PIA-induced effects. R-PIA and NECA did not displace 3H-haloperidol from rat striatal membranes nor effect in vitro prolactin release from rat anterior pituitary cells grown in culture. Based upon these findings it is postulated that R-PIA and NECA may be increasing prolactin secretion in part by inhibiting central dopamine release, although other mechanisms may also be operating.

Adenosine↗

Wheelchair cushion effect on skin temperature, heat flux, and relative humidity.

For patients subject to decubitus ulcers, wheelchair cushions should be prescribed with knowledge of the cushion's effect on the thermal as well as mechanical environment of the skin. To define thermal effects that may be encountered during routine use, tests werr made on 24 commercially available cushions. Skin temperature, heat flux and relative humidity were measured under the ischial tuberosities of a normal 24-year-old man during a 1-hour period of sitting on each cushion. After 1 hour, skin temperatures increased by means of 3.4 C and 2.8 C on foams and viscoelastic foams and there were slight decreases in heat flux as compared with control values in air. On gels, skin temperatures remained constant and heat flux increased, while water "floatation" pads caused a mean skin temperature decreased of 2.7 C along with a marked increase in heat flux. Relative humidity at the skin cushion interface increased by 10.4%, 22.8% and 19.8% on foams, gels and water floatation pads, as compared with room air values. Representative cushions from each of the general types (foam, viscoelastic foam, gel and water floatation) also were subjected to 2-hour tests which indicated the measured parameters continued to change asymptotically.

Adult↗

Changes in pituitary hormone secretions and corpora lutea following PGF2alpha administration to PMS/hCG-stimulated rats.

Pseudopregnancy was induced in 26 day old female rats by giving 30 IU of PMS followed 56 hours later with 5 IU of hCG. Day 1 of pseudopregnancy was considered established 72 hours after PMS administration. Pseudopregnancy lasted 14 to 15 days. Ovarian weights increased for 4 to 8 times due to treatment. Histological examiniation of the corpora lutea (CL) of pseudopregnancy suggested luteolysis began on day 6 and extended to day 8. A "new" crop of CL appeared on day 9 suggesting the duration of pseudopregnancy was supported by more than one generation of CL or by CL maturing at different rates. Twice daily administration of 1 mg PGF2alpha on days 5 to 8 prevented the appearance of the "new" CL on day 9, and increased signs of luteolysis in the initially formed CL. Lower doses (0.01 and 0.1 mg, b.i.d., X 4 days) delayed the appearance of "new" CL until day 10. Blood samples withdrawn between 0930 and 1100 hours were analysed for FSH, LH and prolactin. Animals treated with 0.01 and 0.1 mg of PGF2alpha, b.i.d., X 4 days had increased LH values on day 8, thus the PG appeared luteotrophic. Rats treated with 1 mg of PGF2alpha, b.i.d., X 4 days had decreased LH values on day 7 and the CL showed subsequent luteolysis. FSH levels were relatively constant during pseudopregnancy. However, all doses of PGF2alpha reduced FSH levels on day 7. An associated decrease in uterine weight occurred, possibly due to reduced follicular development. Prolactin levels fell in response to PGF2alpha treatment which undoubtedly contributed to the observed luteolysis. The signs of early cessation of pseudopregnancy were: increased serum FSH on days 9 and 10; increasing uterine weight; and the reappearance of follicular growth. These data suggest that PGF2alpha reduced the duration of pseudopregnancy primarily by inhibiting the secretion of FSH, LH and prolactin.

Animals↗

A comprehensive cardiovascular waveform analysis program for IBM-compatible personal computers.

Computerized cardiovascular waveform processing has become a necessary and fundamental tool in the analysis of physiologic data. The availability of numerous commercial data-analysis programs has significantly enhanced the efficiency of waveform analysis. Many such programs come with their own programming language, which enables the researcher to create an application program suited to a specific series of calculations. Once written, an application program can significantly increase the efficiency with which data from a specific experiment can be analyzed. However, creating or modifying a program for each new experimental protocol can be time-consuming, especially in the error-detection and verification stages. Single-purpose programs also prove somewhat inflexible to unexpected changes in experimental formats. These problems suggested the need for a more flexible program, but one that is nevertheless specifically suited to the analysis of cardiovascular signals. This need led to the development of a program designed in collaboration with surgeons and physiologists. This program addresses some important analysis problems in cardiovascular research, and allows the user to survey and manipulate cardiovascular waveforms in an intuitive and spontaneous manner.

Algorithms↗

In vitro quantification of regurgitant jet flow by color Doppler ultrasound and conservation of momentum.

Prosthetic valve regurgitant jets can be imaged with color Doppler ultrasound (CDU), but clinical quantitation remains elusive. An equation based on an integrated conservation of momentum analysis was implemented for CDU quantitation of regurgitation. This was compared with a simple, non-CDU momentum balance analysis recently reported that requires only a pulsed Doppler ultrasound (PDU) reading within the jet and a continuous wave Doppler (CWD) reading of the orifice velocity. For in vitro steady flows, the simple, non-CDU method was accurate only with PDU readings taken 5 cm from the orifice; flows were underestimated when readings 1 and 3 cm from the orifice were used. The CDU method was accurate, even when flows calculated from readings between 0.5 and 6.0 cm from the orifice were averaged together.

Blood Flow Velocity↗

In vitro ultrasound characterization of a polyurethane trileaflet valve.

Polyurethane synthetic trileaflet valves were compared with commercial prostheses in vitro, in a pulse duplicator using ultrasound to characterize the flow velocities and patterns. Flow-pressure drop behavior was in the middle range of other prosthetic valves. Diastolic regurgitant jets were located by color Doppler ultrasound, and there appeared to be some leakage through the leaflet fold at the commissure. Nevertheless, the closing volumes and closed valve leakage volumes were, on average, lower than other prosthetic valves. Systolic 20 Hz spectral oscillations detected with pulsed Doppler and continuous wave Doppler were attributed to leaflet flutter in the open valve.

Aortic Valve↗

A computerized physiologic pulse duplicator for in-vitro hydrodynamic and ultrasonic studies of prosthetic heart valves.

A physiologic pulse duplicator for the simultaneous in-vitro hydrodynamic and ultrasonic evaluation of aortic prosthetic heart valves is described. The system is interfaced to a personal computer, which provides greater efficiency over manual techniques in system calibration, data acquisition, and analysis. The data analysis program aids selection of start and end systole and calculates pressure difference across the valve, the closing and regurgitant volumes, flow rates, and the Gabbay and Swanson performance indices. The pulse duplicator is designed to accommodate the ultrasonic measurement of fluid velocities, including pressure difference via the Bernoulli equation, and color-flow imaging. In tests of 19-mm, 23-mm, and 27-mm Bjork-Shiley spherical occluder valves, continuous-wave Doppler ultrasound was found to overestimate by about 50% the pressure difference measured directly by pressure transducers, a finding that is clinically important.

Aortic Valve↗