Osteolysis in cemented titanium alloy hip prosthesis.

We evaluated 132 consecutively implanted cemented titanium alloy stems (Ti6-Al7-Nb, SLS-88) after a mean follow-up of 6.6 years (range 5-7 years). Almost 30% of the stems showed significant osteolysis, mainly in the proximal stem area. The amount of osteolysis correlated significantly to a typical pain pattern: dull, circular, and occurring at rest. Six stems had already been revised, and another 7 stems were loose clinically and radiologically, which resulted in a Kaplan-Meier survivorship of 95% for stem revisions and 88% for stem failures (revisions plus loose stems). We found that smaller stem sizes tend to increase the development of osteolysis and loosening. Two factors seem to play a role in early loosening of cemented titanium alloy stems: i) increased elasticity of titanium, which leads in small stem sizes to micromotion between the stem and cement and to cement breakage, and ii) corrosion of the cemented titanium alloy stem and subsequent osteolysis in the adjacent bone. The combination of both factors (high elasticity plus corrosion) accelerates the degradation of the bone anchorage of the stem and initiates early loosening. We advise against the further use of cemented SLS-88 titanium alloy stems.

Adult↗

Heterotopic ossification in total hip arthroplasty: the significance for clinical outcome.

This study evaluates 706 patients with 835 primary total hip replacements documented in a prospective fashion in a multicenter study with respect to correlation between heterotopic ossification (HO) and clinical outcome. Only patients without prophylaxis against HO entered the study. The mean clinical and radiological follow-up was 3.1 years (+/- 0.7). Heterotopic ossification was noted in 47% of all total hips replaced. It was graded as mild (Brooker I) in 29.1%, moderate (Brooker II) in 12.7%, and severe (Brooker III and IV) in 5.2%. All clinical parameters investigated were significantly affected with the increasing amount of heterotopic ossification. The strongest correlation was found in flexion range and spreading distance. Both factors were significantly decreased with higher degrees of ossification. The other clinical parameters investigated, walking capacity, limp, and use of analgesics, were altered to a lesser extent and only with higher degrees of heterotopic bone formation. Finally, patient satisfaction was significantly influenced by the degree of heterotopic ossification and dropped from almost 90% good or excellent patient satisfaction in the non-ossification group to less than 30% in the group with severe ossification.

Aged↗

Nerve palsy after leg lengthening in total replacement arthroplasty for developmental dysplasia of the hip.

We reviewed 508 consecutive total hip replacements in 370 patients with old developmental dysplasia of the hip, to relate the amount of leg lengthening to the incidence of nerve palsies after operation. There were eight nerve palsies (two femoral, six sciatic), two complete and six incomplete. We found no statistical correlation between the amount of lengthening and the incidence of nerve damage (p = 0.47), but in seven of the eight hips, the surgeon had rated the intervention as difficult because of previous surgery, severe deformity, a defect of the acetabular roof, or considerable flexion deformity. The correlation between difficulty and nerve palsy was significant (p = 0.041). We conclude that nerve injury is most commonly caused by direct or indirect mechanical trauma and not by limb lengthening on its own.

Adult↗

Fatal cardiac tamponade associated with posterior spinal instrumentation. A case report.

STUDY DESIGN: Case report of a fatal complication of pedicle screw instrumentation and review of the literature. OBJECTIVE: To describe the clinical and postmortem findings in a 35-year-old man who sustained a T11 burst fracture that was managed by transpedicular posterior instrumentation and who died 12 days after surgery of cardiac tamponade caused by a prick injury of the right coronary artery. SUMMARY OF BACKGROUND DATA: Posterior pedicle screw instrumentation is considered a safe and effective method for stabilizing a spinal motion segment. Nevertheless, there are several rare but significant complications that may occur. This is the first report of a heart tamponade after transpedicular screw insertion. METHODS: A 35-year-old man was treated for a T11 burst fracture with posterior transpedicular stabilization. The surgery was uncomplicated. RESULTS: Twelve days after the intervention, the patient died of cardiogenic shock. Postmortem examination showed a heart tamponade of 350 mL blood originating in a prick injury of the right coronary artery. Histologic findings showed evidence that the injury was caused during surgery by a Kirschner wire. CONCLUSION: There are numerous possible intraoperative complications in posterior pedicle screw fixation, such as nerve root and spinal cord injuries. This case of a fatal heart tamponade after transpedicular screw insertion is rare. It shows that the surgeon must be aware of potential risks associated with such a procedure and have a comprehensive three-dimensional understanding of the anatomic structures involved.

Adult↗

[Missed compartment syndrome after anterior cruciate ligament-plasty following continuous peridural anesthesia].

In this article we report a case of an early postoperative compartment syndrome of the anterior tibial compartment with complete sensomotoric palsy of the peroneal nerve after arthroscopic-assisted replacement of the anterior cruciate ligament (ACL) of the knee. The tourniquet pressure was 360 mm Hg and operation time was 1.75 h. After the operation the leg was bandaged to avoid swelling of the leg and as antithrombotic prophylaxis. Analgesic therapy was by continuous epidural bupivacaine infusion. Increasing pain of the lower leg was suppressed by additional analgesia. Due to persistent pain despite regular analgesia, the patient was sent to a main hospital on the 3rd postoperative day, where an extremely painful and swollen anterior tibial compartment with intracompartmental pressure of over 100 mm Hg was found. The compartment was released immediately. Despite the appearance of severe muscle damage, no extensive débridement was done. At the second examination, at 48 h, there was minimal perfusion of the muscles without contraction and islands of ischemic necrosis. Clinically, there was complete palsy of the dorsiflexors of the foot. The case shows the danger of a compartment syndrome when tourniquet of the limb, arthroscopy and a firm bandage are combined. Continuous epidural analgesia masks the classic symptoms of compartment syndrome.

Adult↗

[Management of IIIB open tibial fractures by early osteosynthesis and local muscle flap].

From 1986 to 1994 18 patients with 19 IIIB open tibial fractures were treated following similar therapeutic management. This included early and radical primary debridement, early and wherever possible immediate internal fixation of the bone and coverage with a local muscle flap (hemisoleus or gastrocnemius). At the time of follow-up all fractures had consolidated clinically as well as radiographically. The mean time to bony union was 7 months (3-20). Twelve patients did not have any severe pain and were able to walk for more than 4 km. The time to return to work averaged 8 months. In 2 cases a permanent disability of 50% was established. Fourteen of 18 patients were satisfied with the function of the leg. On the other hand, 9 didn't like the aesthetic appearance and were inhibited because of it. The following complications occurred within a period of 2 years: non-union (3), flap necrosis (2), osteomyelitis (2), delayed union (4). The mean number of reoperations was 3 (0-8). In no case did an amputation have to be performed.

Adult↗

The value of preoperative planning for total hip arthroplasty.

To analyse the value and accuracy of preoperative planning for total hip replacement (THR) we digitised electronically and compared the hand-sketched preoperative plans with the pre- and postoperative radiographs of 100 consecutive primary THRs. The correct type of prosthesis was planned in 98%; the agreement between planned and actually used components was 92% on the femoral side and 90% on the acetabular side. The mean (+/- SD) absolute difference between the planned and actual position of the centre of rotation of the hip was 2.5 +/- 1.1 mm vertically and 4.4 +/- 2.1 mm horizontally. On average, the inclination of the acetabular component differed by 7 +/- 2 degrees and anteversion by 9 +/- 3 degrees from the preoperative plans. The mean postoperative leg-length difference was 0.3 +/- 0.1 cm clinically and 0.2 +/- 0.1 cm radiologically. More than 80% of intraoperative difficulties were anticipated. Preoperative planning is of significant value for the successful performance of THR.

Acetabulum↗

Bilateral total hip arthroplasty: one stage versus two stage procedure.

The purpose of this study was to determine if any differences existed in the early complication rate, short term clinical outcome, and total length of hospital stay between patients who had bilateral total hip arthroplasty performed under a single anesthetic (during 1 patient visit to the operating room) and patients who had the procedure performed under 2 anesthetics (during 2 patient visits to the operating room). Patients operated on bilaterally were divided into 3 groups: Group A (1 stage procedure)--hips that were operated on simultaneously (128 hips); Group B (2 stage procedure)--surgeries performed less than 6 weeks apart (126 hips); and Group C (2 stage procedure)--surgeries performed between 6 weeks and 6 months apart (256 hips). All patients were evaluated after an average followup of 1.5 years. There were no differences in operative, early local, or general complications among the 3 groups. In particular, no higher incidence of pulmonary embolism or deep vein thrombosis was found in the 1 stage group. Preoperatively, very stiff hips (total range of motion < 50 degrees) gained significantly more motion in the 1 stage group than in the 2 stage groups, whereas hips with better preoperative motion (total range of motion > 50 degrees) improved the most in Group B, without a significant difference occurring between Groups A and C. The degree of pain reduction was the same in all groups, but patients in the 1 stage group had a significantly better capacity for walking after their procedure. Average total hospital stay was 5 to 6 days less for the patients in Group A than those in the other groups, which, combined with using the operating room only once, resulted in a reduction of overall hospital costs by more than 30% when using the 1 stage procedure.

Adult↗

Non-union of the scaphoid. Revascularization of the proximal pole with implantation of a vascular bundle and bone-grafting.

Eleven patients who had an ununited fracture of the scaphoid associated with loss of the blood supply to the proximal fragment were managed operatively with a combination of an inlay corticocancellous bone graft from the iliac crest and implantation of the second dorsal intermetacarpal artery, its accompanying venae comitantes, and a thin cuff of perivascular tissue. The absence of the blood supply to the proximal pole was evidenced both by radiographic changes--which included increased bone density, absence of normal trabeculae, and cystic changes--and by failure to observe bleeding bone during the operation. There were ten men and one woman. The average duration of non-union was fourteen months (range, six to thirty-three months). Six patients had had previous unsuccessful operative attempts to obtain union. Eight non-unions were in the proximal one-third and three, at the waist of the scaphoid. Union was achieved in ten patients at an average of ten weeks postoperatively. According to the wrist-scoring system of the Mayo Clinic, at an average of five years (range, 2.5 to eleven years), three patients had a grade of excellent; three, good; three, fair; and two, poor. Four patients had subsequent reconstructive procedures; radial styloidectomy, styloidectomy and resection of osteophytes, radioscapholunate arthrodesis, and total wrist arthrodesis were performed in one patient each.

Adult↗

A comparative analysis of distraction rods versus Luque rods in thoracic spine fractures.

The findings of this study emphasize the importance of distraction in obtaining and maintaining reduction in upper thoracic fractures that are unstable and collapsing into kyphosis. It also shows that a Luque rectangle construct cannot fulfill this function adequately in this type of fracture. Thirty-four consecutive cases of surgically treated upper thoracic spine fractures were reviewed. Two patients died, and 4 were lost to follow-up, so after a minimum 6-month clinical and radiographic follow-up there were 11 patients in the Luque group and 17 in the distraction rod group. Preoperatively, there was no significant difference in age, sex, level of injury or severity of kyphosis between the two groups. The Luque stabilization took an average of 1 h longer. There was no difference in local, general or neurological complications between the groups. Pain at the final follow-up was the same according to analgesic use. The kyphosis in the Luque group increased progressively from preoperative to postoperative values continued and to increase. In the distraction rod group the postoperative kyphosis was improved compared with the preoperative values. At final follow-up the kyphosis had returned nearly to the preoperative values. The difference in the adequacy of the reduction as measured by percentage of anterior collapse between the two groups is highly statistically significant: distraction rod better postoperatively, P = 0.0114 (Student's t-test); distraction rod better at final follow-up, P = 0.0054 (Student's t-test).

Adult↗

[Axillo-femoral bypass: indications and results].

Axillofemoral bypass grafting is an accepted method for the treatment of vascular insufficiency of the lower limb. It is especially useful in high risk patients whose conditions preclude aortofemoral bypass grafting. The goal of our study is to evaluate whether the benefit of this operation outweigh the potential risks in the age group "sixty-plus". We performed 23 axillofemoral bypass grafting procedures (axillofemoral in 20, axillobifemoral in 3 cases) mainly be mean of 8 mm Dacrom prosthesis. The 30-day operative mortality rate was 8.7% and the cumulative 5-year patient survival rate was 52.2%. Overall the 1- and 5-year life table patency rate were 80% and 64%, respectively. The cumulative limb salvage was 90% and 72% at 1 and 5 years. We obtained an average reduction in Fontaine classification of 2 stages in the first year and 1.3 stages after 5 years. The comparison of the cumulative survival rate with the limb salvage rate indicates that advanced age should not be considered a contraindication to performing an axillofemoral bypass graft. The reduction in Fontaine stage means a remarkable improvement in quality of life.

Aged↗

[Long-term results with the cementless CLS stem in hip replacement].

OBJECTIVE: The present work aims at evaluating the clinical and radiological long-term results of the cementless CLS stem in hip replacement. METHOD: Sixty-six consecutively operated patients were examined clinically and radiologically at an average follow-up time of 10.7 (7.6 - 13.8) years. The clinical evaluation was done with the Merle d'Aubigné and the Harris hip scores. The radiological evaluation included the evaluation of radiolucencies as well as the occurrence of heterotopic ossifications. RESULTS: A total of four stems had to be revised (two infections, two periprosthetic fractures). No stem revision had to be done because of aseptic loosening. This results in a survival rate of 94.5% according to Kaplan-Meier. The mean Merle d'Aubigné scores increased from 9.0 preoperatively to 16.0 points at follow-up. The mean follow-up Harris hip score was 87.3 points. Periprothetic osteolytic zones were observed in 45% of the cases, particularly in the Gruen zones 1 and 7. These osteolytic zones were mainly found in connection with cementless polyethylene cups. CONCLUSION: The results of this study confirm the positive short and medium-term results with the CLS stem in a long-term process. The formerly described phenomenon of the residual thigh pain with cementless stems was clearly minimized.

Adult↗

Long-term results of arthroscopic meniscal repair. An analysis of isolated tears.

From 1984 through 1986 we performed 54 arthroscopic meniscal repairs on patients with anterior cruciate ligament-stable knees. We evaluated the repair results of 52 of these patients at an average followup of 7.5 years. In 40 patients the meniscal repairs had not failed and these patients were examined clinically and radiographically; in 25 cases, magnetic resonance imaging was also performed. Significantly more failures (P < or = 0.05) occurred when the rim width of the tear was greater than 3 mm and when the tear was repaired with resorbable sutures. Conversely, the following factors were found to favorably influence meniscal healing (P > 0.05); time from injury to surgery less than 8 weeks, patient age less than 30 years, tear length less than 2.5 cm, and tear in the lateral meniscus. The overall failure rate after 7.5 years was 27% (14 of 52); 64% (9 of 14) of the failures occurred in the first 6 months after repair. The clinical and radiographic evaluation of the successfully repaired knees showed that 90% (36 of 40) had normal knee function; the remaining 10% (4 patients) had nearly normal knee function. Magnetic resonance imaging, however, showed a persisting grade 3 or 4 lesion in 96% (24 of 25) of the successfully repaired menisci and is therefore not reliable in assessing meniscal healing.