Search PubMedSearch

Biomedical subjects

S Del Giudice

Publications and source records attributed to S Del Giudice.

4 recordsLinked to original sources

[Early peak of CPK in acute myocardial infarct: a marker of clinical instability?].

The evaluation of the CPK-peak time (CPK-p) during Acute Myocardial Infarction (AMI) is now considered as a reliable method to identify ischemic myocardial tissue reperfusion both spontaneous and pharmacologically-induced. The purpose of this study is to assess the clinical significance of this index over a non selected group of patients (pts) affected by a first episode of AMI looking for some variables possibly connected with it. This study includes 114 pts hospitalized in our Unit Coronary Care (UCC) and diagnosed as affected by AMI and not treated with anticoagulant and/or fibrinolytic drugs. They were divided according to CPK-p into 2 groups: group A (23 pts, 18M 5F, mean age 64.2 +/- 10.1y; CPK-p 11.9 +/- 3.3h, AMI Anterior 14/AMI Inferior 9) and group B (91 pts, 85M 6F, mean age 64 +/- 10.3y; CPK-p 25.7 +/- 4.5h, AMI Anterior 50/AMI Inferior 41). Moreover, a third group C has been studied including pts with similar clinical characteristics who underwent thrombolysis by intravenous infusion of Streptokinase (48 pts, 39M 9F, mean age 62.7 +/- 10.6y; CPK-p 15.2 +/- 7h, AMI Anterior 28/AMI Inferior 20). For each pt CKP-p has been evaluated as well as the pre-UCC time (T-pc), the maximum value of released CPK (CPK-max), the incidence of new coronary events such as angina, re-AMI, sudden death detected between the 1st (NEC-I) and the 6th month (NEC-II) after the acute event.(ABSTRACT TRUNCATED AT 250 WORDS)

Angina Pectoris

[Non-invasive evaluation with continuous Doppler of the systolic pressure of the right ventricle in patients with tricuspid insufficiency].

Tricuspid regurgitation (TR) is detected by Doppler echocardiography in a high proportion of patients with right ventricle pressure or volume overload. Continuous wave Doppler (CW) provides a noninvasive estimation of the transtricuspid systolic pressure gradient, applying the modified Bernoulli formula to the maximum velocity of the TR jet. The purpose of this study was to test the accuracy of the CW prediction of systolic right ventricular pressure (RVPs), obtained adding a clinical estimate of the mean right atrial pressure (RAPm) to the Doppler derived pressure gradient. The study population consisted of 22 adult patients with Doppler proved TR, undergoing right heart catheterization (cath) for mitral valve disease (12 pts), atrial septal defect (8 pts), dilated cardiomyopathy (1 pt) or pulmonary hypertension (1 pt). Two studies were duplicated after nifedipine administration. TR was graded by pulsed Doppler flow mapping as mild in 7, moderate in 11, severe in 4 pts. RAPm was estimated clinically from the inspection of neck veins pulsatility (mmHg = pulsatility cm+5/1.3). At CATH RVPs ranged from 27 to 80 (46 +/- 17) mmHg, RAPm from 0 to 13 (6 +/- 3) mmHg. RVPs Doppler prediction showed a close correlation with CATH (r .97, SEE 4.2 mmHg), with a slight mean underestimation (-2 +/- 4 mmHg) (Fig. 3, Tab. I). The discrepancies between CW and CATH ranged from -9 to +10 mmHg, almost entirely due to inaccuracy of the RAPm clinical estimate (r .48, see 3.8 mmHg) (Fig. 4, Tab. I).(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent

Investigation of temperature fields around embedded cryoprobes.

The temperature fields around cryoprobes were investigated analytically and experimentally. Two cryoprobes were employed: a spherically shaped general purpose probe utilizing liquid nitrogen and a cylindrical "glaucoma" probe utilizing the Joule-Thomson effect in gaseous CO2. Both probes were operated by commercial cryostats. The analytical solutions included a one-dimensional integral solution for the general purpose cryoprobe, and finite element solutions for both cryoprobes. Both solutions were based on the enthalpy method. Analytical and experimental results compared reasonably well. Deviations of these results are believed to be due, mainly, to the incomplete specification of the boundary conditions on the surface of the cryoprobe.

Cryosurgery