Phase-shifting point-diffraction interferometer developed by using the electro-optic effect in ferroelectric crystals.

A novel and simple phase-shifting point-diffraction interferometer using a z-cut lithium niobate wafer is proposed. The pinhole is realized by an optical lithography process, aluminum deposition, and subsequent lift-off on the surface of the wafer. The phase shifting is obtained by inducing the electro-optic effect along the z crystal axis. We demonstrate experimentally the possibility of retrieving an aberrated wavefront.

Journal Article↗

Tunable two-dimensional hexagonal phase array in domain-engineered Z-cut lithium niobate crystal.

An optical phase array with tunable phase step is demonstrated. The phase array consists of a two-dimensional hexagonal lattice of inverted ferroelectric domains fabricated on a Z-cut lithium niobate substrate. The electro-optically tunable phase step is obtained by the application of an external electric field along the z axis of the crystal via transparent electrodes. Theoretical analysis and experimental results are presented, showing that a tunable and flexible adaptive optical illuminator device can be realized by combining the electro-optic tunability with the Talbot effect. Generation of a multiplicity of light patterns is shown.

Journal Article↗

Quantitative phase-contrast microscopy by a lateral shear approach to digital holographic image reconstruction.

Combining the concept of lateral shear interferometry (LSI) within a digital holography microscope, we demonstrate that it is possible to obtain quantitative optical phase measurement in microscopy by a new single-image-processing procedure. Numerical lateral shear of the reconstructed wavefront in the image plane makes it possible to retrieve the derivative of the wavefront and remove the defocus aberration term introduced by the microscope objective. The method is tested to investigate a silicon structure and a mouse cell line.

Algorithms↗

Recovering correct phase information in multiwavelength digital holographic microscopy by compensation for chromatic aberrations.

We demonstrate experimentally that correct phase imaging without 2pi ambiguity is obtainable in digital holography by using a multiwavelength approach in the microscope configuration. We describe a general approach for removing chromatic aberrations and for controlling the pixel size of the reconstructed phase image in multiwavelength digital holography when the Fourier transform method is adopted for the numerical reconstruction of digital holograms. The retrieved phase is affected by the unavoidable, unwanted chromatic aberration. The correct phase can be obtained by evaluating the phase from the reference holograms reconstructed at different wavelengths to compensate for the chromatic aberration.

Algorithms↗

Two-dimensional mapping of electro-optic phase retardation in lithium niobate crystals by digital holography.

We demonstrate accurate two-dimensional mapping of the phase retardation induced by the electro-optic effect in lithium niobate crystals. Off-axis digital holography is used to investigate congruent z-cut crystals. The spatially resolved optical path difference is interferometrically measured while a linearly rising voltage ramp is applied to the crystal. This procedure provides information on the uniformity of crystals' electro-optic properties and offers the ability to detect the presence of defects that is of fundamental importance for reliable processing of photonic devices.

Journal Article↗

Time-resolved contrast function and optical characterization of spatially varying absorptive inclusions at different depths in diffusing media.

The role of a spatially varying absorptive inhomogeneity located at different depths within a turbid material has been investigated. This inhomogeneity has been characterized by a spatially dependent Gaussian distribution of its absorption coefficient. The present study has been performed calculating the time-resolved contrast function in the framework of the first-order perturbative approach to the diffusion equation for a slab geometry and a coaxial measurement scheme. The model has allowed us to take into account different locations of the inclusion along the source-detector axis. The accuracy of time-resolved contrast predictions has been analyzed through comparisons with results of the finite element method that has been used to numerically solve the diffusion equation. Recovery of the absorption perturbation parameter of the inhomogeneity for different axial positions has also been investigated.

Computer Simulation↗

Perturbation model to predict the effect of spatially varying absorptive inhomogeneities in diffusing media.

We develop a perturbation model to predict the effect of a spatially varying absorptive inhomogeneities in a diffusing slab. The model is based on a perturbation solution of diffusion equation derived for a refractive index mismatch between the scattering slab and the surrounding medium, through the use of the extrapolated boundary conditions. We show that the model allows to compute the time-dependent relative change in the transmitted signal resulting from the presence of the inclusion. We derive simplified expressions for the perturbed time-resolved transmittance that allows to implement an efficient fitting procedure for obtaining the optical properties of the absorptive inclusion. The accuracy of the predictions of the model was investigated through comparison with the results of the Finite Element Method to solve the time-dependent diffusion equation numerically. The procedure is used to obtain the absorption perturbation parameter of an absorptive inclusion characterized by spatially dependent Gaussian distribution of its absorption coefficient located at the midplane of a scattering slab.

Journal Article↗