Duration of action of atracurium when given by infusion to critically ill children.

The aim of the study was to investigate the offset time of atracurium when given by continuous infusion on a paediatric intensive care unit and to look for evidence of tolerance. Over a period of 8 months, 20 mechanically ventilated children had a steady-state infusion of atracurium discontinued to enable the assessment of their level of sedation. The offset time of atracurium was assessed by train-of-four (TOF) stimulation of the ulnar nerve. The initial TOF reading was documented as was the time taken to reach a TOF ratio of 0.9. Thirty-five assessments were carried out. The mean offset time of atracurium was 28.7 min (SEM 1.76 min, range 8-56 min). There was no correlation between the dose of atracurium at discontinuation and the offset time of the infusion. The duration of infusion was negatively correlated with the offset time of atracurium, and this effect was most prominent in children who had received infusions for longer than 48 h. When given by continuous infusion, the offset time of atracurium is very variable between individual patients. Infusions administered for longer than 48 h are associated with a significant reduction in the offset time as a result of increasing tolerance.

Adolescent↗

The effect of induced hypothermia on the duration of action of atracurium when given by infusion to critically ill children.

The aim of the study was to investigate the effect of induced hypothermia on the offset time of atracurium when given by continuous infusion to critically ill children. Over a period of 8 months, six mechanically ventilated children had a steady-state infusion of atracurium discontinued. The offset time of atracurium was assessed by train-of-four (TOF) stimulation of the ulnar nerve; recording the time taken to reach a TOF ratio of 0.9. Nine assessments were carried out. The mean offset time of atracurium was 82 min. This was significantly longer than in patients with temperatures within the normal physiological range. When considering all assessments, performed both in hypothermic and normothermic patients, there is a strong correlation between rectal temperature and the offset time of atracurium. Prolonged moderate hypothermia has a very significant effect on the offset time of atracurium when given by infusion to critically ill children.

Adolescent↗

Quality of sedation during mechanical ventilation.

The aim of the study was to determine the quality of sedation in ventilated patients on a general paediatric intensive care unit (PICU), including those treated with infusions of neuromuscular blocking agents. Twenty-eight ventilated children on a PICU had their level of sedation determined using an arousability scale dependent upon the response to tracheal suction. Observed levels of sedation were then compared to a predetermined desired level of sedation. A total of 81 assessments were performed and 90% were considered satisfactory. Thirty-two of these assessments were performed in 15 children following the temporary discontinuation of infusions of neuromuscular blocking agents; 97% of these assessments were considered satisfactory. A regime of continuous intravenous midazolam and morphine with additional oral sedation using chloral hydrate and antihistamines when required provides a satisfactory level of sedation for the majority of children ventilated on a PICU, including those treated with infusions of neuromuscular blocking agents.

Administration, Oral↗

Paradoxical embolism in a boy with cystic fibrosis and a stroke.

An 11 year old boy with cystic fibrosis suffered a stroke, producing right sided weakness. Four years previously a totally implantable venous access device (Port-a-Cath) had been inserted. Magnetic resonance angiography revealed a filling defect in the left middle cerebral artery. Transoesophageal echocardiography demonstrated a thrombus attached to the tip of the Port-a-Cath and also the presence of a patent foramen ovale. After an initial period of anticoagulation the defect was closed using a septal occlusion device introduced via a cardiac catheter. The boy's neurological signs completely resolved and he remains free from further thromboembolic episodes. Whilst pulmonary embolism has been described before in relation to a totally implantable venous access device, this is believed to be the first description of a paradoxical embolism in relation to such a device.

Catheterization, Central Venous↗