Experimental studies on intravenous regional analgesia using radioactive lidocaine.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to S Cotev.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Intravenous (IV) anesthesia titrated to continuous computer-processed electroencephalograms (EEGs) was studied in 32 consecutive patients undergoing cardiac surgery. Anesthesia was induced with fentanyl 50 micrograms/kg with no EEG monitoring (n = 16) or 25 to 50 micrograms depending on changes in EEG (n = 16). EEG, oxygen saturation by pulse oximeter, intra-arterial blood pressure (BP), central venous pressure (CVP), and pulmonary artery pressure (PAP) (n = 18) were monitored continuously. Cardiac output (CO), CVP, PAP, spectral-edge frequency for each hemisphere, and BP were recorded before induction, immediately before intubation, and 1 and 5 minutes after intubation. With EEG monitoring, intubation was performed when spectral-edge frequency decreased to 10 Hz or less. Recall and pain were investigated 2 to 12 weeks postoperatively. With EEG, the amount of fentanyl used before intubation was significantly lower (39.7 +/- 2 micrograms/kg; p less than 0.005) than without EEG (50 micrograms/kg). The decrease in BP (% change) was less with than without EEG; mean changes in BP between preinduction and preintubation were -7.4% +/- 3.8% and -16.5% +/- 3.1% and between preinduction and 1 minute after intubation 0.3% +/- 3.4% and -12.5% +/- 3.5%, respectively. Percent changes in mean BP between intubation and 1 minute after were 9.6% +/- 4.0% with EEG and 5.2% +/- 3.0% without EEG. No patient in either group had recall. The authors conclude that using EEG monitoring to estimate depth of anesthesia during induction and laryngoscopy may increase safety in high-risk patients undergoing cardiac surgery.
Explore the source record for details and available documents.
We report an evaluation of the effect of postive-end-expiratory-pressure (PEEP) on improving pulmonary oxygenating capacity in the adult respiratory distress syndrome (ARDS), when the latter is associated with generalized gram-negative sepsis. Fifty-seven cases treated in our RICU with PEEP ventilation (April 1972 to January 1975) were retrospectively reviewed. Oxygenating capacity improvement was evaluated in terms of the changes in PaO2/FIO2 and AaDO2 (FIO2 = 1.0). Both the short term (2-3 hours from the initiation of PEEP) and the overall effects of PEEP were evaluated. A mean PEEP of 5.6 cm H2O initially increased PaO2/FIO2 by a mean of 94 torr and decreased AaDO2 (FIO2 = 1.0) by 105 torr in the 28 nonseptic patients. In the 29 septic patients, 5.1 cm H2O PEEP initially increased PaO2/FIO2 by 32 torr and decreased AsDO2 (FIO2 = 1.0) by 38 torr. The differences between the septic and nonseptic patients were statistically significant (P less than 0.001). Likewise, the long-term effect of similar levels of PEEP was in increasing PaO2/FIO2 by 142 torr and by 75 torr in the nonseptic and septic patients, respectively. The final reduction in AaDO2 (FIO2 = 1.0) was 163 torr and 87 torr in the nonseptic and septic patients, respectively. These differences between patient groups were also statistically significant (P less than 0.02). Mortality during PEEP was 15/29 and 3/28 in the septic and nonseptic patients, respectively. Overall mortality in the septic and nonseptic groups was 18/29 and 5/28, respectively. We conclude that ARDS with sepsis constitutes a more severe pulmonary insult than ARDS without sepsis, and/or that generalized sepsis creates a more prolonged pulmonary insult that makes it less amenable to PEEP. Thus, high levels of PEEP may be needed to treat ARDS associated with sepsis.
An unusual placement of a "central" venous catheter in the porto-hemiazygous system of a cirrhotic patient in septic shock is described. The catheter was misinterpreted as being located in a central vein and served initially as a guide for volume replacement. The high central venous pressure recorded (22 cm H2O) in spite of signs of hypovolemia led to the introduction of a Swan-Ganz catheter which confirmed the presence of hypovolemia. The proper position of the central venous catheter, especially in cirrhotic patients, should not only be confirmed by plain chest x-ray but also by injection of contrast medium.
Overinflation of endotraceal-tube cuffs may seriously compromise the patient's airway, due to collapse of the wall of the endotracheal tube. Two case reports describe this complication, with x-ray demonstration of the hyperinflated cuffs.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
We present three patients with successful surgical repair of abdominal aortic aneurysms with signs of imminent rupture in octogenarians. The patients presented with evidence of severe left ventricular dysfunction and reduced compliance either before or during surgery. Extremely cautious delivery of fluids and of after-load reducing agents was employed under the guidance of measurements of cardiac output and filling pressures from a pulmonary arterial catheter inserted prior to surgery.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.