Background suppression with multiple inversion recovery nulling: applications to projective angiography.

We have developed a technique to accurately null the longitudinal magnetization (Mz) of background material. This suppression involves first saturating the longitudinal magnetization (Mz) of a region, and then applying several nonselective inversions. The inversions are timed relative to the saturation such that Mz is nulled across a broad range of T1 at a predetermined time after the initial saturation. B1 and B0 inhomogeneity, which could lead to inaccurate suppression, are dealt with by the combination of a multiple tip saturation sequence and four adiabatic inversion pulses. The suppression sequence can be used to form projective angiograms by selectively tagging the imaging region with the saturation pulse. After the inversions are played out, a projection taken through the tag region when Mz is nulled will only contain signal from blood that has flown into the region after the saturation. Since only two dimensions are acquired, the technique can acquire gated projection angiograms in reasonable scan times. Representative inflow MIR angiograms of the carotid arteries and renal arteries show excellent background suppression.

Carotid Arteries↗

A readout magnet for prepolarized MRI.

Conventional MRI systems rely on large magnets to generate a field that is both strong and extremely uniform. This field is usually produced by a heavy permanent magnet or a cryogenically cooled superconductor. An alternative approach, called prepolarized MRI (PMRI), employs two separate fields produced by two different magnets. A strong and inhomogeneous magnetic field is used to polarize the sample. After polarization, a weak magnetic field is used for readout. These fields can be produced by two separate resistive electromagnets that cost significantly less than a single permanent or superconducting magnet. At Stanford, the authors are constructing a PMRI prototype scanner suitable for imaging human extremities roughly 20 cm in diameter. With this system the authors hope to demonstrate comparable image quality to MRI with reduced system cost. The authors' initial work on low-frequency reception indicates that it will be possible to obtain comparable image signal-to-noise ratio to an MRI scanner operating at the same polarizing field strength. To reduce the capital cost of the system, the authors use resistive electromagnets. Here the authors discuss the full development of the readout magnet including important design considerations, shimming, and field plots. These encouraging results are an important step toward evaluating the cost effectiveness of PMRI.

Cost-Benefit Analysis↗

Novel approaches to low-cost MRI.

This paper presents a combination of speculative approaches, some related to earlier work and some apparently novel, which show great promise in providing a new class of MRI machines that would be considerably less expensive. This class would have advantages and disadvantages as compared to existing MRI, over and above that of low cost. The disadvantages include the apparent inability to perform classic spectroscopy, and limited flexibility in the area of selective excitation. The advantages include a fundamental immunity to inhomogeneity and susceptibility problems, the ability to create a wide class of machines that are designed for specific anatomy-related applications, the ability to design open machines for physician access, and improved capability for high speed imaging. Generic to all of the methods presented are a pulsed polarizing field and an oscillatory read-out bias field. The pulsed field initially polarizes the magnetic moments. Since it is not on during the readout operation it has negligible homogeneity requirements since changes in the field amplitude will merely shade the image intensity. During readout a relatively low bias field is used. To enable the use of a relatively inhomogeneous bias field, an oscillatory field is used that has a zero average value. This prevents any long-term buildup of phase errors due to a frequency error associated with inhomogeneity. Thus the average bias frequency will be determined solely by the frequency rather than the amplitude of the bias field. Three methods are described, all including the above features. The first two involve imaging in the laboratory frame, while the third involves imaging in the rotating frame. The second approach requires no RF excitation and the third approach uses RF bias and gradient signals. Some approaches to slice selection are described.

Costs and Cost Analysis↗

Two-dimensional selective adiabatic pulses.

Using the technique of separable k-space excitation, we have designed a two-dimensional selective adiabatic pulse that inverts magnetization from a square region in the xy plane with insensitivity to RF variations. We also have designed a two-dimensional adiabatic pulse that inverts selectively in frequency and in one spatial dimension. The pulses should be useful for both MR imaging and spectroscopy. We present experimental results to demonstrate that the two-dimensional adiabatic pulses are feasible on commercial MR imaging systems.

Humans↗

A reduced power selective adiabatic spin-echo pulse sequence.

We introduce a selective adiabatic pulse sequence suitable for generating selective spin-echoes for both MR imaging and spectroscopy. The technique is simple; one uses the echo generated by any pair of identical selective adiabatic inversion pulses. The nonlinear phase across the slice is compensated perfectly by the second pi pulse. This compensation is immune to RF inhomogeneity and nonlinearity. For imaging applications, we concentrate on a reduced-power version of the pulse sequence in which time is traded off variably for RF amplitude in the presence of a time-varying gradient. This technique, known as variable-rate excitation, mildly degrades the off-resonant slice profile when applied to amplitude-modulated pulses. We present theoretical explanations and experimental results that show that the variable-rate adiabatic pulses are immune to off-resonant degradation of the magnitude normally encountered in MR imaging.

Brain↗