Use of a new fallback function to prevent endless-loop tachycardias: first clinical results. The Investigators of the Multicenter Study.

The methods used for preventing endless-loop tachycardias (ELTs) most often consist of initiating a long postventricular atrial refractory period (PVARP) with the sensing of every event likely to induce ELTs, such as sensed premature ventricular contractions (PVCs). A new fallback function may be useful to prevent the initiation of ELTs. A window of atrial rate acceleration detection (WARAD) is initiated with the sensing of every sinus event and equals 75% of the preceding PP interval. If an atrial event is sensed during this period, as are premature atrial contractions (PACs), no atrioventricular (AV) delay is initiated, but an atrial pulse output is delivered and a subsequent 31-msec AV delay is started. Theoretically retrograde P waves are premature compared to sinus rhythm. They are therefore detected as PACs, and do not initiate AV delay, thus prohibiting the induction of ELTs. This function was tested in six patients, using external or implanted Chorus 2 pacemakers. Short PVARP (203 msec) and high atrial sensibility were programmed. Retrograde conduction was induced either by inefficient atrial pacing or a long programmed AV delay. Two different dual chamber settings were tested: dual chamber pacing with the fallback function On or Off. In every situation, the function proved effective in preventing ELTs: the number of tachycardia episodes went from 124 with the function programmed Off to 5 with the function programmed On for comparable durations. More than 75 ELTs effectively prevented by fallback have been recorded.

Aged↗

[Environment and permanent cardiac pacing].

The increasing technological sophistication of cardiac pacemakers make them potentially more vulnerable to electrical interference. The clinical consequence are of variable importance depending on the type of pacemaker and the nature of the interference. Electrical interference is present in the domestic, industrial and, above all, the medical environment. Apart from controlling the sources of emission, prevention requires standards of protection for the casing and electronic circuitry. Patient education remains primordial.

Electric Countershock↗

Dynamic electrophysiology of ventriculoatrial conduction: implications for DDD and DDDR pacing.

The behavior of ventriculoatrial conduction (VAC) during exercise remains unknown. In order to determine its characteristics and the consequences it might have on dual chamber pacemaker technology and programming, 17 patients underwent an electrophysiological study (EPS) of atrioventricular conduction (AVC) and of VAC during a protocol including three steps: supine rest, upright position, and finally during cycloergometric exercise; the measurements were done at progressively increasing pacing rates. During a preimplantation EPS, Wenckebach points AVC-W and VAC-W and conduction times, AVCT and VACT (as a function of pacing rate), were measured in ten consecutive patients using temporary leads and an external device. In another study, AVCT, VACT, AVC-W, and VAC-W were measured by telemetric recordings under identical conditions in seven patients implanted earlier with a DDD pacemaker. A 1/1 VAC was observed in 7/17 patients (41%) at rest, and in 13/17 patients (76%) at the end of the protocol; VAC was never observed in 4/17 patients (23%), but occurred in six of the ten patients initially free, three standing at rest and three on exercise. For all patients, the VAC behavior remained of "nodal" type, indicated by a progressive increase in VACT as pacing rate rose up to the VAC-W point. Neither the existence of exercise-induced VAC nor the maximal VACT-W could be predicted from AVC or VAC data obtained at rest. However, at the same pacing rates, standing up and exercise induced a shortening effect on VACT, and improved the VAC-W by an average of 33%. These results suggest that the electrophysiological behavior of VAC does not obey any general rule and cannot be predicted individually. It would thus appear unwise to base pacemaker mediated tachycardia (PMT) protection solely on long postventricular atrial refractory period (PVARP) programming in DDD patients. This work also revealed the potential risks of a rate responsive auto-adaptive PVARP algorithm as proposed in certain new devices.

Adult↗

[Benefits and limits of single chamber atrial pacing with adaptive rate].

Twelve patients with isolated symptomatic sinus node dysfunction or bradycardia-tachycardia syndrome with atrial chronotropic incompetence during exercise testing were managed by single chamber rate responsive atrial pacing (AAIR) when AV conduction was normal, or by a dual chamber DDDR pacemaker programmed in the AAIR mode when AV conduction was abnormal, and followed up for 12.5 +/- 9.8 months. The patients were assessed clinically, by 3 monthly ECG and Holter recordings and comparative exercise tests in AAI and AAIR modes at the 6th month. One patient with an AAIR system was excluded at M21 because of symptomatic AV block requiring reimplantation of a DDD pacemaker. Ten of the 11 remaining patients are asymptomatic and have an excellent quality of life; one patient had invalidating symptoms on exercise attributed to the "AAIR pacemaker syndrome" which were corrected by reprogramming the pacemaker and modifying the medical therapy. The comparative exercise stress tests showed a significantly higher heart rate in the AAIR mode compared to AAI pacing at the initial and intermediate exercise levels (30 to 70 W); on the other hand, the heart rates were not significantly different at the highest exercise levels although in the AAI mode, the terminal acceleration sometimes occurred in junctional rhythm whereas it was usually an atrial paced rhythm in the AAIR mode. The total duration of exercise was longer in the AAIR mode (+22%; p less than 0.01) when the 8/11 patients with chronotropic incompetence during the baseline study were considered. The spike-R interval adapted normally to exercise in only one case: in the other patients, the interval remained constant or, in the worst of cases (N = 4), it increased paradoxically, to result in the "AAIR pacemaker syndrome": this phenomenon is observed mainly in patients treated by antiarrhythmics and/or betablockers. The AAIR mode would therefore seem to be a simple, effective and reliable method of treating patients with sinus node dysfunction and chronotropic incompetence; however, the failure of adaptation of the PR interval is a real limitation to its use and may constitute an argument in favour of the choice of a DDR pacemaker in these patients.

Adult↗