Search PubMed⌕ Search

Biomedical subjects

S Caroli

Publications and source records attributed to S Caroli.

At least 19 recordsLinked to original sources

Levels and risk assessment for humans and ecosystems of platinum-group elements in the airborne particles and road dust of some European cities.

Traffic is the main source of platinum-group element (PGE) contamination in populated urban areas. There is increasing concern about the hazardous effects of these new pollutants for people and for other living organisms in these areas. Airborne and road dusts, as well as tree bark and grass samples were collected at locations in the European cities of Göteborg (Sweden), Madrid (Spain), Rome (Italy), Munich (Germany), Sheffield and London (UK). Today, in spite of the large number of parameters that can influence the airborne PGE content, the results obtained so far indicate significantly higher PGE levels at traffic sites compared with the rural or non-polluted zones that have been investigated (background levels). The average Pt content in airborne particles found in downtown Madrid, Göteborg and Rome is in the range 7.3-13.1 pg m(-3). The ring roads of these cities have values in the range 4.1-17.7 pg m(-3). In Munich, a lower Pt content was found in airborne particles (4.1 pg m(-3)). The same tendency has been noted for downtown Rh, with contents in the range 2.2-2.8 pg m(-3), and in the range 0.8-3.0 and 0.3 pg m(-3) for motorway margins in Munich. The combined results obtained using a wide-range airborne classifier (WRAC) collector and a PM-10 or virtual impactor show that Pt is associated with particles for a wide range of diameters. The smaller the particle size, the lower the Pt concentration. However, in particles <PM-10, some of the highest values correspond to the fraction <0.39 microm. Considering an average Pt content in all particles of approximately 15 pg m(-3), which is representative for all countries and environmental conditions, the tracheobronchial fraction represents approximately 10% and the alveolar fraction approximately 8% of the total particles suspended in air. However, from the environmental risk point of view, an exposure to PGEs in traffic-related ambient air is at least three orders of magnitude below the levels for which adverse health effects might theoretically occur (of approx. 100 ng m(-3)). Therefore, today inhalation exposure to PGEs from automotive catalysts does not seem to pose a direct health risk to the general population. Even though the data available today indicate no obvious health effects, there are still a number of aspects related to PGEs and catalysts that justify further research. First, continual monitoring of changes in PGE levels in air and road dust is warranted, to make sure that there is no dramatic increase from today's levels. Secondly, more detailed information on the chemical composition of the PGE-containing substances or complexes leaving the catalyst surface and the size distribution of the PGE-containing particles released during driving will facilitate a more in-depth human risk assessment.

Air Pollutants↗

Environmental risk of particulate and soluble platinum group elements released from gasoline and diesel engine catalytic converters.

A comparison of platinum-group element (PGE) emission between gasoline and diesel engine catalytic converters is reported within this work. Whole raw exhaust fumes from four catalysts of three different types were examined during their useful lifetime, from fresh to 80,000 km. Two were gasoline engine catalysts (Pt-Pd-Rh and Pd-Rh), while the other two were diesel engine catalysts (Pt). Samples were collected following the 91441 EUDC driving cycle for light-duty vehicle testing, and the sample collection device used allowed differentiation between the particulate and soluble fractions, the latter being the most relevant from an environmental point of view. Analyses were performed by inductively coupled plasma-mass spectrometry (ICP-MS) (quadrupole and high resolution), and special attention was paid to the control of spectral interference, especially in the case of Pd and Rh. The results obtained show that, for fresh catalysts, the release of particulate PGE through car exhaust fumes does not follow any particular trend, with a wide range (one-two orders of magnitude) for the content of noble metals emitted. The samples collected from 30,000-80,000 km present a more homogeneous PGE release for all catalysts studied. A decrease of approximately one order of magnitude is observed with respect to the release from fresh catalysts, except in the case of the diesel engine catalyst, for which PGE emission continued to be higher than in the case of gasoline engines. The fraction of soluble PGE was found to represent less than 10% of the total amount released from fresh catalysts. For aged catalysts, the figures are significantly higher, especially for Pd and Rh. Particulate PGE can be considered as virtually biologically inert, while soluble PGE forms can represent an environmental risk due to their bioavailability, which leads them to accumulate in the environment.

Air Pollutants↗

Platinum-group elements: quantification in collected exhaust fumes and studies of catalyst surfaces.

Automotive catalytic converters, in which Pt, Pd and Rh (platinum-group elements; PGEs) are the active components for eliminating several noxious components from exhaust fumes, have become the main source of environmental urban pollution by PGEs. This work reports on the catalyst morphology through changes in catalyst surface by scanning electron microscopy/energy dispersive X-ray spectroscopy (SEM/EDX) and laser-induced breakdown spectrometry (LIBS) from fresh to aged catalytic converters. The distribution of these elements in the fresh catalysts analysed (Pt-Pd-Rh gasoline catalyst) is not uniform and occurs mainly in a longitudinal direction. This heterogeneity seems to be greater for Pt and Pd. PGEs released by the catalysts, fresh and aged 30,000 km, were studied in parallel. Whole raw exhaust fumes from four catalysts of three different types were also examined. Two of these were gasoline catalysts (Pt-Pd Rh and Pd-Rh) and the other two were diesel catalysts (Pt). Samples were collected following the 91,441 EUDC driving cycle for light-duty vehicle testing. The results show that at 0 km the samples collected first have the highest content of particulate PGEs and although the general tendency is for the release to decrease with increasing number of samples taken, exceptions are frequent. At 30,000 km the released PGEs in gasoline and diesel catalysts decreased significantly. For fresh gasoline catalysts the mean of the total amount released was approximately 100, 250 and 50 ng km(-1) for Pt, Pd and Rh, respectively. In diesel catalysts the Pt release varied in the range 400-800 ng km-1. After ageing the catalysts up to 30,000 km, the gasoline catalysts released amounts of Pt between 6 and 8 ng km(-1), Pd between 12 and 16 ng km(-1) and Rh between 3 and 12 ng km(-1). In diesel catalysts the Pt release varied in the range 108-150 ng km(-1). The soluble portion of PGEs in the HNO3 collector solution represented less than 5% of the total amount for fresh catalysts. For 30,000 km the total amount of soluble PGEs released was similar or slightly higher than for 0 km.

Electrochemistry↗

Reference values for selected trace elements in serum of term newborns from the urban area of Rome.

Reference values for Al, Cd, Co, Cu, Li, Mn, Mo, Ni, Rb, Se and Zn, and indicative intervals for Sb are proposed in serum from cord blood of 143 term newborns of the urban area of Rome. On the basis of the eligibility criteria adopted, only babies with gestational age > 37 weeks and body weight at the delivery > 2500 g, i.e., "normal" term infants, were included in this study. With the exception of Cd, Li, Ni and Sb, experimental data for each of the other analytes were found to approach a normal distribution. The estimated references values (in ng/ml) were the following: Al, 1. 12-6.79; Cd, 0.10-0.52; Co, 0.20-0.43; Cu, 140-691; Li, 0.31-2.23; Mn, 0.79-3.26; Mo, 0.36-1.56; Ni, 0.20-3.15; Rb, 196-1302; Sb, 0. 10-1.48 (indicative range); Se, 20.2-69.7; and Zn, 318-1405. For several elements, the information available in the relevant literature does not allow adequate comparisons to be performed. This was actually possible only for Cu, Se and Zn. The correlations between the weights at birth (BW), gestational ages (GA) and elemental concentrations were elucidated. As expected, significant positive correlations were found for Cu and Se with GA and BW, respectively. Strong mutual associations were observed for several other elements, but their interpretation is still debatable.

Birth Weight↗

Activity of cisplatin and ICI 182,780 on estrogen receptor negative ovarian cancer cells: cell cycle and cell replication rate perturbation, chromatin texture alteration and apoptosis induction.

The activity of cisplatin (CP, range of concentrations 0.25-1 microg/ml), the pure steroidal antiestrogen compound ICI 182,780 (range of concentrations, 0.01-10 microM) and various combinations of, was investigated on an estrogen receptor negative ovarian cancer cell line (A2780 WT) and its CP-resistant derivative subline (A2780 CP3). CP markedly reduced A2780 WT cell growth but marginally affected A2780 CP3, whereas ICI 182,780 was effective on both cell lines. CP but not ICI 182,780 provoked a significant blockade in late S/G(2) phase in both cell lines, particularly in the parental line. Measuring the number of rounds of cell replications showed that CP diminished the cell replication rate of both cell lines, particularly in A2780 WT. Conversely, ICI 182,780 reduced the cell replication rate of A2780 CP3 but not A2780 WT cells. Both drugs provoked apoptosis in A2780 WT cells, as assessed by the appearance of large (50-300 kbp) DNA fragmentation. However, laser scanning cytometry showed that only CP induced a measurable alteration of chromatin texture in A2780 WT but not in A2780 CP3 cells. The combination CP and ICI 182,780 resulted in a synergistic inhibitory activity of cell growth with a CP potentiation up to 4 and 11-fold in A2780 WT and A2780 CP3 cells, respectively. This reflected an enhanced reduction of the cell replication rate and did not involve perturbations of the cell cycle other than those provoked by CP alone. Apoptosis induction and the level of CP-DNA adducts were not influenced by adding ICI 182,780 to CP in both cell lines.

Antineoplastic Combined Chemotherapy Protocols↗

Assessment of reference values for elements in human hair of urban schoolboys.

Hair samples of youngsters (3-15 years of age) from several urban areas of Rome were analyzed to determine the content of 19 minor and trace elements with the aim of assessing Reference Values (RVs). Thirteen essential elements were taken into account, Ca, Co, Cr, Cu, Fe, Mg, Mn, Mo, Ni, P, Se, V and Zn. On the other hand, Al, As, Cd, Pb, Sr and Ti were also evaluated on the basis of their potential toxicity. Procedures were developed for the collection, storage and pre-analytical treatment of samples. Measurements were performed by inductively coupled plasma atomic emission spectrometry. Subgroups were formed according to age and sex. Significant differences were found for certain elements depending on age and sex. This was the case, e.g., for Ca which showed a mean value of 336 mg/kg for males and of 537 mg/kg for females. The sex-dependent pattern for this element was also apparent when the three age subgroups of 3-6, 7-10 and 11-15 years were compared. The overall RVs obtained (mg/kg) are as follows Al, 10.2; As, 0.09; Ca, 450; Cd, 0.23; Co, 0.67; Cr, 0.99; Cu, 22.1; Fe, 19.0; Mg, 28.0; Mn, 0.35; Mo, 0.43; Ni, 1.49; P, 195; Pb, 7.11; Se, 0.77; Sr, 1.20; Ti, 0.79; V, 1.22; and Zn 150.

Adolescent↗

Reference values for chromium, nickel and vanadium in urine of youngsters from the urban area of Rome.

In the assessment of human health risk, the obtainment of reference values in biological tissues and/or fluids is crucial to estimate the type and magnitude of occupational and environmental exposure. In this context, urine is the major excretion route for many noxious substances that have entered the organism and can be viewed as one of the most useful materials for biomonitoring campaigns. In this study, reference concentration ranges for Cr, Ni and V in urine were achieved in a sub-population of 131 youngsters, aged 6-10, attending primary schools in the urban area of Rome. Subjects under drug therapy or affected by any pathological diseases were not included in this investigation. Strict precautions against contamination or loss of the analytes of interest were adopted for all steps. Determinations were performed by means of high resolution inductively coupled plasma mass spectrometry. In general, the natural log-transformed concentration data for the three elements investigated conformed to a satisfactorily normal distribution. The estimated reference ranges were as follows (microg g(-1) creatinine): Cr, 0.07-0.76; Ni, 0.20-1.23; V, 0.02-0.22. The sex of the youngsters was tentatively treated as a statistical explanatory variable using the Fischer F-test on variance.

Child↗

Minor and trace element content of two typical Italian sheep dairy products.

The concentration ranges in milk and cheese of a number of metallic elements relevant to the health of the consumer are dependent upon animal species, feeding, time of year, environmental conditions and manufacturing processes. We have measured the concentrations of selected trace elements--Al, Ba, Cd, Co, Cr, Cu, Fe, Mg, Mn, Ni, Pb, Pt, Sr and Zn--in raw ewes' milk and typical ewes' milk cheeses. Samples of milk, curd, whey, cheese after moulding, cheese after salting, commercial cheese (Pecorino), Ricotta, scotta and brine were analyzed for seven complete cycles of cheese production. Samples of curd, whey, brine and waste product (i.e. scotta) were collected and analysed in addition to the cheese and milk to assess the distribution of each element in the main product, by-products and waste products during cheesemaking. Quantitative determinations were performed mainly by inductively coupled plasma atomic emission spectrometry. There were considerable differences among the trace element contents of raw ewes' milk and related products, indicating that manufacturing processes play a key role in the distribution of minor and trace elements. Two different approaches were used to assess the dietary intake of these elements associated with the consumption of Pecorino and Ricotta, and whether this had any nutritional or toxicological implications. The results indicated no toxicological risk and showed that, on the contrary, Pecorino may be a good source of several essential elements.

Animal Feed↗

cis-Diamminedichloroplatinum(II) given in low-dose continuous infusion with concurrent radiotherapy to patients affected by inoperable lung carcinoma: a pharmacokinetic approach.

The pharmacokinetics of cis-diamminedichloro platinum(II) (cisplatin), given as a continuous infusion with concurrent radiotherapy to patients with locally advanced inoperable non-small-cell lung carcinoma, was investigated in 16 cases. The regimen, repeated for 6 consecutive weeks, consisted of weekly 10-Gy radiotherapy given in five fractions from Monday to Friday, and concurrent 100-h infusion of cisplatin delivered at a daily dose of 4 mg/m2 by a central venous catheter and a portable pump. Throughout the weeks of therapy the platinum levels were determined in plasma and in ultrafiltered plasma by respectively inductively coupled plasma atomic emission spectrometry and inductively coupled plasma mass spectrometry. Mean levels of platinum in plasma ([Pt]tot ) increased from the 1st to the 6th week of infusion, while mean levels of platinum in ultrafiltered plasma ([Pt]uf), 110 microg/l, showed no marked variation throughout the therapy. [Pt]uf ranged from 16% to 22% of the total Pt. Mean levels of Pt in ultrafiltered plasma were of the same order of magnitude as those found to be active in vitro as radiopotentiators. Pt decay levels were measured for 24 h at the end of the 1st and 5th weeks of infusion, allowing the calculation of the Pt half-life and the area under the decay curves. The mean value of the area under the decay curve, plotting [Pt]tot against time (AUC), in the range 0-24 h from the end of the 5th week of infusion, was about twice that from the end of the 1st week; by contrast, the mean AUC values did not vary for the [Pt]uf against time curves. The mean values of the alpha half-life of Pt in the ultrafiltered plasma were in accordance with those published in the literature; however, an unexpected very long beta half-life was found (more than 100 h). Thus it was suggested that Pt species other than free cisplatin were present in the ultrafiltered plasma; such species probably involve metal bound to low-molecular-mass proteins. Throughout the therapy, the toxic effects in all patients were negligible, and 75% of them had an objective locoregional reduction of disease. In only 2 cases was progression of disease observed within the irradiated area. On the basis of these data, it can be concluded that cisplatin at a level of 110 microg/l in the ultrafiltered plasma, in the reported scheme of continuous intravenous infusion, has an enhancing effect on radiation and avoids concentration peaks of platinum not bound to protein.

Adult↗

Use of the stable isotope 65Cu test for the screening of Wilson's disease in a family with two affected members.

BACKGROUND/AIMS: An improved method for the study of copper metabolism in Wilson's disease, using a stable, rather than radioactive, copper isotope (65Cu) has recently been described. We report on the use of this method for the study of a family with two members affected by Wilson's disease. SUBJECTS: The family comprised parents and four siblings: one 20-year-old male and three females, aged 22, 17 and 5 years, respectively. The boy and the 17-year-old girl both presented with liver cirrhosis. Diagnosis of Wilson's disease was suggested by elevated liver copper content and/or low caeruloplasmin levels and Kayser-Fleischer ring. METHODS: All family members were given an oral dose of 3 mg of 65Cu. Blood samples were taken at 0, 1, 2, 6, 24, 48, and 72 hours. In 4 subjects, additional blood samples were drawn at 7, 14 and 21 days after dosage. The ratio 65Cu:63Cu in serum was determined in all samples by means of Inductively Coupled Plasma Mass Spectrometry. RESULTS: The diagnosis of Wilson's disease was confirmed in the two symptomatic members by the unequivocal decrease observed in the 65Cu percent enrichment, which approached zero by 72 hours. In contrast, Wilson's disease could be definitely excluded in both siblings, one of whom only 5 years old, on the evidence of net secondary peaks, showing normal incorporation of 65Cu into caeruloplasmin. These findings were later confirmed by genetic analysis. Parents, who carried defective genes with different mutations, also showed different abnormalities of copper metabolism. CONCLUSIONS: The oral test with the stable copper isotope 65Cu is a safe, non invasive option able to exclude Wilson's disease in patients with a difficult diagnosis or in a presymptomatic stage. However, positive tests must still be confirmed by copper dosage in liver biopsies, as heterozygotes can present with severe alterations of copper metabolism, without developing symptoms of the disease. The use of this test in conjunction with genetic analysis on a larger number of heterozygous subjects may add to the understanding of the Wilson's disease defect.

Adolescent↗

The role of hypoxic stop-flow perfusion and high dose chemotherapy in the treatment of regionally advanced colorectal cancer.

The primary or secondary forms of colorectal cancers involving local structures or spreading in the abdomen or pelvic area without extra-regional metastases are identified as regionally advanced colorectal cancers (RACRC). They are unresectable and thus radiotherapy and chemotherapy are the fundamental treatment methods. However, these regimens have failed to check the diffusion of tumor satisfactorily in most forms of RACRC. The abdominal and pelvic regions can be isolated from corporal circulation by temporary occlusion of the aorta and cava and perfused with high doses of chemotherapeutic drugs. The hypoxic abdominal or pelvic stop-flow method for delivering high-dose antiblastic agents to these body districts to avoid toxicity by chemofiltration has been suggested. This study examines the possibility of using this method to treat various forms of RACRC.

Abdominal Neoplasms↗

Iron overload in patients with chronic viral hepatitis: how common is it?

OBJECTIVES: To establish the prevalence of increased hepatic iron content in patients with hepatitis C virus-related chronic hepatitis and to assess the accuracy of serum iron and ferritin in detecting tissue iron overload. METHODS: Serum iron, serum ferritin, and hepatic iron content were determined in 81 consecutive patients undergoing liver biopsy for chronic ALT elevation and hepatitis C virus infection. Moreover, in a subgroup of 28 patients, outcome of a 6-month course of interferon (IFN) treatment (6 million U of recombinant IFN, three times weekly) was determined after a mean follow-up of 24 +/- 6 months and the outcome was compared with the pretreatment values of hepatic iron content. RESULTS: Elevated serum iron or ferritin levels were detected in approximately 40% of patients, but elevated hepatic iron content was observed in only eight patients (10%). One of these patients had a hepatic iron index > 1.9, indicating hemochromatosis. Liver iron content and serum iron levels were not correlated. No differences in hepatic iron content were observed among patients with a sustained response to IFN (seven patients), short-term responders (seven patients), or nonresponders (14 patients). CONCLUSIONS: Ten percent of patients with chronic hepatitis C have elevated hepatic iron content. These patients cannot be identified using serum markers of iron status. The relationship between liver iron and response to IFN treatment requires further prospective investigations.

Adult↗

Tamoxifen synergizes the antiproliferative effect of cisplatin in human ovarian cancer cells: enhancement of DNA platination as a possible mechanism.

We investigated the chemosensitizing activity of tamoxifen (TAM) on estrogen receptor negative ovarian cancer cell lines sensitive (A2780 WT) and resistant to cisplatin (CP) (A2780 CP3). Our results showed that the treatment of both cell lines with the association TAM + CP (concentration range 0.01-1 microN and 0.1-1 microgram/ml, respectively) results in a synergistic antiproliferative activity and a complete reversal of the acquired CP-resistant phenotype. We demonstrated that in A2780 cells the addition of TAM to CP treatment is able to significantly enhance at every tested CP dose (P < 0.001) the amount of platinum (Pt) bound to the DNA. Since Pt-DNA levels in the genome are clearly related to the growth inhibitory effect of CP (correlation value = 0.97, P < 0.001) in our experimental model, we hypothesized that TAM could act synergistically with CP and overcome the acquired CP-resistance by enhancing Pt binding to the DNA. We suggest that, from a clinical point of view, TAM may be usefully included in CP-based chemotherapy regimens for ovarian cancer patients since plasma concentrations of the drug capable of in vitro CP resistance modulation are achievable in vivo. A prospective clinical trial to verify the clinical usefulness of combined TAM + CP treatment in ovarian cancer patients refractory to prior Pt-based chemotherapy is now underway in our department.

Antineoplastic Agents↗

The Role of Chirocephalus diaphanus in the Early Recognition of Environmental Pollution by Trace Elements

A study was undertaken to evaluate whether the fairy shrimp Chirocephalus diaphanus (Crustacea: Anostraca) could be considered as a species capable of biomonitoring environmental contamination by accumulating trace elements. This preliminary investigation aimed at assessing the levels of As, Cd, Cu, Hg, Pb, Se, and Zn in natural waters as well as in adults and cysts of fairy shrimps sampled from five different sites in central Italy. Trace elements were determined by inductively coupled plasma (ICP)-based spectrometry. In particular, ICP-mass spectrometry (ICP-MS) was resorted to in most cases due to its high detection power. Pretreatment of samples (adults and cysts) consisted basically in the HNO3-assisted microwave digestion of the material. The highest levels of trace elements were found in the anostracan cysts, with concentration ranges (μg/g) of 0.464-3.11 for As, up to 0.820 for Cd, 2.62-13.0 for Cu, 0.011-0.213 for Hg, 0.966-8.46 for Pb, 0.295-2.45 for Se, and 16.4-50.4 for Zn. On the other hand, the lowest concentrations were found in natural waters, with values close to the ICP-MS detection power for some elements. These data are probative of a bioconcentration process, the extent of which is proportional to the environmental level of each element. This may turn out to be useful in planning biological monitoring and assessing ecotoxicological consequences which might ensue from the diffusion of the exploitation of such organisms in aquaculture.

Journal Article↗

Stability of Mercury Dilute Aqueous Solutions: An Open Issue

In the framework of the activities of the European Commission Reference Laboratory (CRL) for residues at the Istituto Superiore di Sanita a number of analytical quality control trials on determination of trace analytes are being carried out. As regards trace elements it soon became apparent that the stability of Hg dilute aqueous solutions is rather unsatisfactory. An investigation was thus undertaken to ascertain the conditions under which the concentration of this metal does not appreciably change. Mercury solutions were prepared in high purity deionized water in the concentration range 1-10 ng g-1 and the effect of various amounts of HNO3 and K2Cr2O7 (alone or in combination) was elucidated by measuring the variations with time in the actual concentration of Hg. Determinations were performed by both inductively coupled plasma atomic emission spectrometry and inductively coupled plasma mass spectrometry. Results show that solutions added with 5% (w/w) HNO3 and 0.01% (w/w) K2Cr2O7 do not undergo any significant alteration in the nominal content of the analyte for at least 1 month. Similar conclusions are reached in the case of solutions enriched in CaCO3, NaCl, NaNO3, KH2PO4, KNO3, and Mg(NO3)2.6H2O to mimic acid digests of meat samples. The improvement ensuing from the adoption of this approach on the performance of the Hg analytical quality control trials is discussed in detail.

Journal Article↗