Search PubMed⌕ Search

Biomedical subjects

S Carerj

Publications and source records attributed to S Carerj.

At least 19 recordsLinked to original sources

Ibutilide for cardioversion of atrial flutter: efficacy of a single dose in recent-onset arrhythmias.

AIM: Ibutilide is particularly effective in rapid termination of atrial flutter (AFL) with few adverse effects. Despite the recommendation of 2 infusions, cardioversion may occur up to 70 minutes after a single dose. We investigated the feasibility, efficacy and safety of a single dose ibutilide treatment of AFL in a single-center, observational study. METHODS: Fifty-nine consecutive patients (44 males, mean age 70 +/- 12), referred to our CCU for paroxysmal AFL (mean arrhythmia duration 10 +/- 18 days), were treated with 1 mg ibutilide. In case of inefficacy, a 2nd dose could be administered 10 to 60 minutes later on the basis of the ECG examination for QTc prolongation and AFL cycle variations. Successful cardioversion was defined as sinus rhythm (SR) restoration within 2 hours. RESULTS: Forty-four patients (75%) converted to SR after ibutilide, 31 with single dose (53%, Group 1), and 13 with double dose (22%, Group 2). AFL duration was shorter in Group 1 (4 +/- 5 vs 16 +/- 29 days). The mean time to the 2nd dose administration was 34 +/- 11 minutes in responders, 51 +/- 23 minutes in non-responders. Only 3 (5%) significant adverse events, all observed after a single dose, occurred. CONCLUSION: Ibutilide is highly effective and safe, in a monitored environment, for rapid termination of AFL. Recent onset AFL may be terminated with a single infusion in many cases; yet, cardioversion should be waited for no more than 30 minutes after the end of the 1st dose, before administering the 2nd one, in order not to reduce the possibility of SR restoration.

Adult↗

Tilt-induced pseudosyncope.

Using the head-up tilt test (HUTT) we evaluated 986 consecutive patients affected by unexplained syncope. In 266 patients the test induced bradycardia and/or hypotension resulting in syncope or presyncope, thus allowing a diagnosis of neurally mediated syncope. In three other patients (0.3% of the entire population and 1% of the all positive tests) HUTT provoked loss of consciousness despite no significant change in heart rate and/or blood pressure. In all three cases unconsciousness was prolonged and no pathological finding was present except lack of response. This phenomenon has been defined as 'pseudosyncope' and related to psychiatric illness. Pseudosyncope induced by HUTT reproduced the clinical events, so the test outcome was considered a true positive response. Our experience suggests that HUTT may contribute to the recognition of psychiatric disorder in some patients affected by unexplained syncope.

Adolescent↗

[Thrombo-embolic risk evaluation in patients with atrial fibrillation. Role of echocardiography].

Atrial fibrillation (AF) is the most common observed cardiac arrhythmia and is the most frequent condition associated with thromboembolic events in patients with or without mitral valve disease. The source of cardiac emboli is the left atrium, the left atrial appendage or, less frequently, the left ventricle. Emboli may also originate from aortic atherosclerotic plaques. It is important to identify patients at risk in order to perform the appropriate therapy. Risk stratification is multiparametric, being based on clinical, laboratory, and echocardiographic data. Several trials have pointed out the role of echocardiography in the evaluation of anatomic and functional parameters associated with thromboembolic risk. Transthoracic echocardiography (TTE) does not provide sufficient information regarding posterior cardiac structures, being its sensitivity in detecting thrombi relatively low (33-72%). Transesophageal echocardiography (TEE) in contrast, has an almost 100% sensitivity; this technique is, therefore, mandatory in patients with AF for an adequate prevention of thromboembolism. The echocardiographic information joined with clinical features allow to stratify, in a proper way, the risk of every single patient.

Atrial Fibrillation↗

[Pathophysiology of congestive heart failure].

Pathophysiology of congestive heart failure (CHF) has undergone a remarkable evolution during the last two decades. CHF is now regarded especially as a neurohormonal disease and not only as a cardiocirculatory impairment. Many studies have emphasized that an abnormal neuroendocrine activation precedes the development of clinically recognized heart failure and plays an important pathogenetic role in progression of this disease. In patients with CHF, moreover, circulating levels of some neurohormonal factors have an independent negative prognostic value. More recently immunological and molecular biology studies have also demonstrated the negative effects exerted by some cytokines and by apoptosis. Correction of neurohormonal disorder is the rationale of therapeutical approach to patients with CHF and appears the only way to significantly decrease mortality. In this review the role of neuroendocrine activation in the pathophysiology of CHF is analyzed.

Angiotensin II↗

[Detection of left ventricular endocardial border with tissue harmonic imaging].

BACKGROUND: Ultrasonic wave propagation in human tissues is not linear. As a consequence, harmonic waves, whose frequency is a multiple (harmonic) of the emitted frequency, are generated. Tissue Harmonic Imaging (THI) processes only the second harmonic frequency in order to improve the signal-to-noise ratio of the received signal. The study was aimed at investigating the impact of THI on the detection of the Left Ventricular (LV) endocardial border. Attention was paid to determine which LV walls were analysed more clearly with THI rather than with conventional Fundamental Frequency Imaging (FFI). METHODS: We compared the FFI and the THI visualization of the 16 LV segments and of the 6 LV walls in 30 consecutive patients by scoring the images as bad, sufficient or good. The equipment used was a GE Vingmed System Five (Orten, Norway). RESULTS: Images were good in 85% of segments explored with THI, whereas FFI provided good images in 47% of segments (p<0.001). From the apical window, visualization of the apex, lateral wall and anterior wall significantly improved with THI; using the parasternal approach, imaging of posterior wall was definitely better with THI than with FFI. CONCLUSIONS: THI enhances both endocardial visualization and global image quality. Tech-nical development, however, increases the diagnostic possibilities of echocardiography but does not substitute the operator's experience.

Echocardiography↗

QRS complex voltage changes associated with supraventricular tachycardia.

INTRODUCTION: The aim of this study was to evaluate the changes in ventricular complex voltage associated with narrow QRS supraventricular tachycardia (SVT). METHODS AND RESULTS: One hundred forty-five patients undergoing catheter ablation for SVT, 85 with AV nodal reentrant tachycardia (AVNRT) and 60 with AV reentrant tachycardia (AVRT) due to a concealed accessory pathway, were studied. Four consecutive tachycardia beats and four consecutive sinus beats were analyzed, excluding the last tachycardia complex and the first sinus one. For each of the 12 leads, the QRS complex voltage was measured, and the results of four beats were averaged both in SVT and in sinus rhythm (SR). The sum (sigma) of the QRS voltages measured in the 12 leads during SVT (sigmaSVT) and SR (sigmaSR) were calculated, as well as the QRS axis during SVT and SR. QRS complex voltage was significantly increased during SVT, with respect to SR, in leads II, III, aVR, aVF, and V2 to V6. In addition, sigmaSVT was significantly greater than sigmaSR. Only lead V1 showed a significant voltage decrease during SVT. These voltage changes were almost identical in patients with AVNRT and patients with AVRT. No relationship was found between tachycardia rate and QRS voltage variation. The QRS axis showed a significant shift during SVT, from 55.8 degrees to 64.5 degrees. CONCLUSION: QRS voltage increase occurs in reentrant SVT, independent of the underlying reentrant circuit. The phenomenon likely depends on tachycardia-related reduced ventricular filling. This could result in displacement of the heart in such a way that the left ventricle becomes closer to the precordial electrodes (proximity effect). Alternatively, decreased intracavitary blood mass could diminish the intracardiac short-circuiting of potentials, resulting in augmented transmission of cardiac vectors to the body surface.

Adolescent↗

Advanced A-V block with apparent A-V junctional escape complexes because of dual A-V nodal pathways.

We report a patient with second degree A-V block in whom several sinus impulses were conducted over the slow A-V nodal pathway, resulting in P-R intervals so prolonged to suggest a diagnosis of intermittent advanced A-V block with A-V junctional escape complexes. However, the "escape" cycles were markedly irregular, and moreover, "escape" complexes often occurred with R-R cycles shorter than those ended by conducted sinus beats. These observations suggested that no escape mechanism was present. The marked variability of P-R intervals was a manifestation of dual A-V nodal pathways: short P-R intervals expressed conduction over the fast pathway, whereas long P-R intervals corresponded to sinus impulses conducted over the slow pathway.

Aged↗

[The second tissue harmonic signal: from physics principles to clinical application].

The second harmonic signals received from organs are due to the non linear properties of tissue which cause distortion of the transmitted signal and are not primarily caused by the transmission of a harmonic frequency. The velocity of ultrasound propagation depends on the density of the insonified material. During the compression phase, the tissue becomes denser, and the ultrasound waves travel faster through the tissue than during the rarefaction phase; the compression phase tends to overtake the rarefaction phase. The ultrasound waveform thus, undergoes a distortion that becomes greater as the distance from the transducer increases. Due to these effects, the tissue tends to generate harmonics and hence shifts energy from the fundamental to the harmonic bands. There are several reasons why harmonic tissue imaging increases the signal-to-noise ratio and facilitates interpretation. In technically difficult patients, there is often a diffuse haze due to distortion of the transmitted beam by shallow surface layers or to reverberations between the skin and ribs. These distortions and reverberations consist almost entirely of ultrasound energy at the fundamental frequency. When the returned signal is filtered at the harmonic so as to reject the fundamental frequency, the clutter and haze are removed and the image becomes more clear and defined. A further reason for the decrease in artifacts and clutter is the side-lobe level reduction in the second harmonic beam. Thus, harmonic beams are narrower and have lower side-lobe levels than fundamental ones. There are several clinical applications of harmonic tissue imaging. These include the correct definition of endocardial borders resulting in an improved assessment of left ventricular function at rest as well as during stress testing, the delineation of the left atrial appendage, the detection of atrial right to left shunting, and left atrial spontaneous echo contrast. Moreover, improved endocardial visualization leads to better endocardial tracking with acoustic quantification and to more segments being interpretable with the anatomic M-mode.

Acoustics↗

[Cardiologic diagnosis of pulmonary embolism: echocardiography].

Pulmonary embolism (PE) represents the third more frequent cardiovascular disease following the acute coronary artery disease and stroke. The most important predisposing clinical condition for PE is represented by the deep-vein thrombosis. The clinical diagnosis of PE has a very low accuracy; so the clinical suspect has to be necessarily directed towards the performance of diagnostic procedures. Among the most used procedures, the echocardiography has a diagnostic role but also a prognostic one. Moreover, it offers precious informations useful to perform the most suitable treatment. The echocardiography features which suggest the presence of pulmonary embolism are: right ventricle and atrium dilatation, right ventricular hypokinesia, systolic flattening of the interventricular septum, tricuspid regurgitation, pulmonary artery dilatation, disappearance or reduction of the inspiratory collapse of the inferior vena cava and presence of eventual embolic sources. According to the involvement degree of right ventricular function, it is generally possible to identify a different survival. The subgroup of patients with moderate or severe right ventricular dysfunction shows a high in hospital and within 1 year death rate. For this reason the right ventricular dysfunction degree together with the hemodynamic stability, are the most important parameters in the therapeutic choice. If there is no right ventricular dysfunction a treatment with heparin is indicated. In presence of right ventricular dysfunction and hemodynamic instability, the thrombolytic treatment is necessary. If the patient is hemodynamically stable, a transesophageal echocardiography is recommended; in case of central thrombosis the thrombolytic therapy or surgery are needed, while if no embolic material is shown the heparin treatment is advisable.

Aged↗