Unexpected ICD pulse generator failure due to electronic circuit damage caused by electrical overstress.

Because it is a lifesaving device, the unexpected failure of an ICD can be catastrophic. We report ICD electronic circuit failure due to electrical overstress damage (EOS) to the high voltage hybird circuit and other electronic components in a series of ICD pulse generator models. Data were obtained from the Multicenter Registry of Pacemaker and ICD Pacemaker and Lead Failures, and from the manufactures' adverse event reports, that were in the FDA's Manufacturer and User Facility Device Experience (MAUDE) database. Of 16 nonbattery Guidant/CPI ICD pulse generator failures reported to the registry, 6 (38%) have been confirmed by the manufacturer to be EOS related, and Guidant/CPI has reported 273 such failures to the FDA as of 12/29/00. The signs of failure included loss of telemetry and inability to deliver therapy, and some patients have experienced serious adverse events. Hybrid circuit damage may have occurred during capacitor charging or reform, and the majority appears to have happened during normal ICD function. While the incidence of this problem is unknown, a management strategy should be adopted that includes routine follow-up every 3 months and device evaluation after a shock or exposure to external defibrillation or electrosurgical devices. This study suggests that additional data are needed to determine the incidence of this problem, and that our present methods for monitoring the performance of ICD's following market release are inadequate.

Defibrillators, Implantable↗

Combined cardiomyopathy and skeletal myopathy: a variant with atrial fibrillation and ventricular tachycardia.

This article describes a family characterized by combined cardiomyopathy and nonspecific skeletal myopathy who present in the third to fifth decades with cardiac manifestations but earlier have evidence of subtle skeletal muscle dysfunction. They differ from previously defined syndromes and potentially represent a different genetic expression or mutation. Cardiomyopathy presents with atrial arrhythmias including AF and atrial flutter. Life-threatening ventricular tachyarrhythmias occur next with onset of ventricular dysfunction. Electrophysiological study revealed sustained monomorphic VT. Affected family members benefitted from an ICD and progression to congestive heart failure (CHF) occurred late. Skeletal myopathy continues with marked progressive muscle weakness and inability to ambulate without assistance. Genetic analysis is currently ongoing. Neurological evaluation in all three family members revealed nonspecific myopathy affecting the psoas and iliopsoas muscles. Atrophy and wasting of the facial and temporalis muscles were common. Skeletal muscle biopsy revealed myofiber atrophy consistent with myopathy.

Atrial Fibrillation↗

Demonstration of myocardial ischemia by an internal loop recorder.

An internal loop recorder (ILR) implanted to evaluate syncope was activated during an episode of chest pain. Analysis of the recorded event revealed a marked increase in the amount of ST-segment depression over baseline. In addition to rhythm analysis, the ILR may be able to assess myocardial ischemia. Further refinements of filtering may make analysis more accurate.

Electrocardiography↗

Transvenous pacemaker insertion ipsilateral to chronic subclavian vein obstruction: an operative technique for children and adults.

Subclavian vein occlusion limits insertion of pacing electrodes in children and adults. The concern is greatest in children with a long-term need for pacing systems necessitating use of the contralateral vein and potential bilateral loss of access in the future. We describe an operative technique to provide ipsilateral access in chronic subclavian vein occlusion in five consecutive pediatric (n = 4, mean age 6.5 years) and adult (n = 1, age 70 with bilateral subclavian vein occlusion) patients in whom this condition was noted at the time of pacemaker or ICD implant. Occlusion was documented by venography. Pediatric cardiac diagnoses included complete heart block in all patients, tetralogy of Fallot in three, and L-transposition of the great vessels in one. Percutaneous brachiocephalic (innominate) or deep subclavian venous access was achieved by a supraclavicular approach using an 18-gauge Deseret angiocath, a Terumo Glidewire, and dilation to permit one or two 9-11 Fr sheaths. Electrode(s) were positioned in the heart and tunneled (pre- or retroclavicularly) to a pre- or retropectoral pocket. Pacemaker and ICD implants were successful in all without any complication of pneumothorax, arterial or nerve injury, or need for transfusion. Inadvertent arterial access did not occur as compared with prior infraclavicular attempts. One preclavicularly tunneled electrode dislodged with extreme exertion and was revised. Ipsilateral transvenous access for pacemaker or ICD is possible via a deep supraclavicular percutaneous approach when the subclavian venous obstruction is discovered at the time of implant. In children, it avoids the use of the contralateral vein that may be needed for future pacing systems in adulthood. This venous approach provides access large enough to allow even dual chamber pacing in children and can be accomplished safely.

Aged↗

Safety and tolerability of an aggressive tilt table test protocol in the evaluation of patients with suspected neurocardiogenic syncope.

Safety and tolerability of a one-step tilt table test with high dose (5 micrograms/min) isoproterenol (ISO) without intermediate stages were evaluated in a symptomatic population of 300 patients referred for clinical syncope, near syncope, or dizziness. ISO has been used as a provocative test but remains controversial. A population of 118 male and 182 female patients with a mean age of 45 (range 5-90) years underwent 300 tests. Heart rate and blood pressure were monitored continuously. A positive test was one in which clinical symptoms were reproduced or hemodynamic criteria met. Patients were initially supine for 5 minutes followed by head upright tilt (HUT) to an angle of 80 degrees for 10 minutes. Negative tests were repeated with an infusion of ISO at a rate of 5 micrograms/min. HUT was positive in 133 (44.3%) of 300 tests. With a 10-minute HUT alone, only 17 (5.7%) of 300 of tests were positive. Of the initial negative tests, 273 of 283 were tested with ISO. With ISO, 116 (42.5%) of 273 were positive. ISO in high dose (5 micrograms/min) was used in 264 of 273 patients, while low dose (1.0-2.5 micrograms/min) was used in 9 of 273 under special circumstances. High dose ISO was tolerated in 164 (62.1%) of 264 patients, reduced in 87 (33%) of 264, and discontinued in 11 (4.2%) of 264. Reasons for reduction included tachycardia (40 patients), nausea (31 patients), chest pain (2 patients), arrhythmia (5 patients), or other (9 patients). Adverse effects resolved within 1 minute of dose reduction. This one-step high dose ISO protocol reproduced neurocardiogenic syncope in symptomatic patients who tested negative without ISO and was safe, tolerated, and expeditious.

Adolescent↗

Multicenter evaluation of implantable cardioverter defibrillator testing after implant: the Post Implant Testing Study (PITS).

To reassess the function of the implantable cardioverter defibrillator (ICD) many electrophysiology centers perform a second test after the initial test at implant. A prospective multicenter study evaluated the necessity and yield of routine postimplant defibrillator testing. The results of 843 postimplant defibrillator tests were collected from 31 centers. The 764 routine tests in which ventricular fibrillation was successfully induced were analyzed. Variables examined included patient age, presenting arrhythmia, underlying heart disease, left ventricular ejection fraction, defibrillator age, make and model of ICD, electrode system, defibrillation threshold, polarity, and waveform. The overall failure rate was 3.1% (24/764). Units tested later than 365 days after implant tended to have a higher failure rate than those tested within the first month or the next eleven months (6.5%, 3.0%, 2.3%, respectively, P = 0.374). The failure rate was higher in patients with left ventricular ejection fraction < 40% than those with higher ejection fractions (3.8% vs 2.0%, P = 0.167). These trends did not reach statistical significance. No other baseline characteristic was associated with higher failure rates. Routine testing of ICDs reveals an overall failure rate of 3.1%. While the rate was low, defibrillator failure places the patient at high risk for sudden cardiac death. As any failure in this population is associated with a high risk of sudden cardiac death, routine defibrillator testing may be justified.

Adolescent↗

Shear syndrome: the worst case scenario of crush syndrome.

Shear syndrome is described as a complication of crush syndrome. In addition to compression of and injury to the electrode, complete transection occurs. In this case, the free end migrated to the pulmonary artery with the potential for further complications.

Aged↗

Long-term patency (9 1/2 years) and atherosclerosis of a polytetrafluoroethylene (Gortex) coronary artery bypass graft.

The patency of a polytetrafluoroethylene (Gortex) graft 9 1/2 years after coronary artery bypass graft surgery (CABG) is demonstrated. While this material is not commonly used as a conduit because of limited success in the past, this case demonstrates that, given the right circumstances, long-term patency is possible. Since available conduits for CABG are quite often limited, viable alternatives may be lifesaving and require further evaluation. In addition to mechanical considerations such as size, length, and material, anticoagulation and strict management of hyperlipidemia may be critical.

Aged↗

Electromagnetic interference and ICD discharge related to chiropractic treatment.

Electromagnetic interference is well known to cause false sensing in ICDs. Sources may include instrumentation involved with acupuncture, arc welding, electrocautery, diathermy, electrolysis, and transcutaneous electric nerve stimulator units as well as power lines. Patients with ICDs are cautioned to avoid exposure to these sources.

Adult↗

Alternative locations for internal defibrillator electrodes.

Successful defibrillation is described in two patients in whom the defibrillating electrode was positioned in the coronary sinus and right ventricular outflow tract as alternative sites. Internal cardiac defibrillation has been successful with single or multiple endocardial electrodes, epicardial patch electrodes, and subcutaneous surface electrodes (patch, array) in varying combinations and recently with an active can electrode. While the traditional location of the endocardial electrode has been the right ventricular apex, we describe two patients in whom defibrillation was successful in alternate locations, the coronary sinus and the right ventricular outflow tract.

Aged↗

Pacing induced ventricular fibrillation in internal cardioverter defibrillator patients: a new form of proarrhythmia.

Current model internal cardioverter defibrillators (ICDs) have cardioversion, defibrillation, pacemaker, and telemetry function. Telemetry documents arrhythmia and facilitates therapeutic adjustments. We report two cases of pacing induced VF terminated by the defibrillator, with the device responsible for both initiation and correction of the arrhythmia.

Arrhythmia, Sinus↗

Pacemaker Twiddler's syndrome.

Twiddler's syndrome may result from pulse generator manipulation or from spontaneous rotation due to movement around an inadequately secured electrode. In this case, the electrode became coiled in the right ventricular outflow tract.

Electrodes↗

Prediction of sudden cardiac arrest: risk stratification by anatomic substrate.

The prognostic importance of coronary artery anatomy to specific outcomes including ventricular tachycardia/fibrillation was evaluated in 372 consecutive patients undergoing cardiac catheterization at University Hospital at Stony Brook between 1981 and 1984. The hypothesis that proximal left anterior descending artery narrowing before the first septal perforator had a specific relationship to survival was again tested in this cohort. The population was prospectively followed for 8 years, with all clinical management decisions made independently by the patient's primary or referring physician. Multivariate statistical and life table analyses were performed after comprehensive follow-up. Significant narrowing in the proximal left anterior descending artery was associated with an increased risk of sudden cardiac death (p = 0.0002). Abnormalities of contractility in the diaphragmatic segment of the left ventricle in addition to an elevation of the left ventricular end-diastolic pressure and the presence of congestive heart failure (p < 0.05) were other contributory variables. Outcome in patients with proximal left anterior descending coronary artery disease who underwent aortocoronary artery bypass to the artery demonstrated improved survival (p < 0.05). Risk stratification of patients at high risk for sudden cardiac death is possible and may allow identification for an aggressive approach or interventional trials.

Adult↗