Search PubMed⌕ Search

Biomedical subjects

S C Manchanda

Publications and source records attributed to S C Manchanda.

At least 37 records · Page 2Linked to original sources

Percutaneous balloon mitral valvuloplasty using the Inoue balloon: analysis of echocardiographic and other variables related to immediate outcome.

To determine whether the mitral valve morphology influences the results of percutaneous balloon mitral valvuloplasty for mitral stenosis, two-dimensional echocardiography was performed before valvuloplasty in 126 patients (mean age 25.5+/-9.4 years) and in 30 normal controls. The 2D echocardiographic features of mitral valve leaflets: thickness, length and motion; diastolic mitral valvular excursion; chordal length; mitral annular diameter; subvalvular distance ratio; distance between mid mitral annulus to left ventricular apex, base and tip of papillary muscle and effective balloon dilating area, effective balloon dilating area/body surface area and effective balloon dilating diameter/mitral annular diameter were then correlated to the immediate post-valvuloplasty mitral valve area. For the total patients population, post-valvuloplasty valve area increased from 0.67+/-0.17 to 2.1+/-0.86 cm2 (P<0.0001), mean transmitral diastolic gradient decreased from 24.5+/-9.0 to 6.0+/-3.0 mm Hg (P<0.0001), mean left atrial pressure decreased from 29.7+/-6.2 to 12.7+/-4.8 mm Hg (P<0.0001), mean pulmonary artery pressure decreased from 44.8+/-14.2 to 25.4+/-9.5 mm Hg (P<0.0001) and cardiac index increased from 2.7+/-0.38 to 3.1+/-0.55 l/min/m2 (P<0.0001). The patients were divided into three groups on the basis of post-valvuloplasty mitral valve area. Group I had valve area <1.5 cm2, group II had valve area from 1.5 to 1.9 cm2 and group III had valve area > or =2.0 cm2. On comparison, no statistically significant difference was found in any of the echocardiographic variables in the three groups. On univariate, multivariate, multiple regression and discriminate function analysis, none of the variables were found to have significant influence on immediate result of valvuloplasty. There was no significant difference in the incidence of mitral regurgitation in any of the three groups. We conclude that the extent of mitral valvular and subvalvular deformity do not have a significant effect on the immediate outcome of mitral valvuloplasty using the Inoue balloon and it can be successfully performed in patients with severe subvalvular fibrosis. Unique balloon geometry and stepwise balloon sizing may explain these acceptable immediate results in severely deformed valves.

Adult↗

Critical appraisal of left ventricular function assessment by the automated border detection method on echocardiography. Is it good enough?

Many studies have attempted to validate the echocardiographic automated border detection (ABD) method for assessing left ventricular ejection fraction (LVEF) by comparing it with various echocardiographic and non-echocardiographic standards. The main basis of assessing its accuracy has been the coefficient of correlation. The fallacy of using coefficient of correlation for assessing agreement between two methods of measurement has been well emphasized in the literature. In the present study we used the Bland and Altman test for testing the accuracy of the ABD method. We compared the ABD method for LVEF assessment with the manual edge detection technique on echocardiography and with radionuclide ventriculography in 34 patients. The majority of patients (76%) had regional wall motion abnormality. The ABD method could be adequately performed in 25 (74%) patients. LVEF was significantly underestimated by the ABD method with very wide limits of agreement when compared with radionuclide ventriculography and the manual edge detection technique (-9.2+/-21.7 and -2.7+/-18.4 respectively, mean error+/-2 standard deviations). Stated simply, the ABD method could overestimate LVEF by 12.5 and 15.7 or underestimate by 30.9 and 21.1 when compared with radionuclide ventriculography and manual edge detection technique, respectively. This large error is by no means acceptable for clinical purposes. It is concluded that at the present stage, the ABD method cannot replace radionuclide ventriculography and manual edge detection technique for assessing LVEF.

Adult↗

Cardiac myxomas: clinical and echocardiographic profile.

We reviewed our clinical and echocardiographic experience in 70 consecutive patients with 73 cardiac myxomas, diagnosed over an 11 year period. There were 21 males and 49 females, ages ranged from 18 to 80 years. Only in 5.7% cases was the diagnosis of myxomas made clinically. 88.6% cases were initially diagnosed as having: mitral valve disease (70%), tricuspid valve disease (10%), ischemic heart disease (5.7%), cardiomyopathy (2.9%), and the remaining 5.7% were detected during family screening and follow-up. The mean duration of symptoms was 10.6 months. The commonest symptom was dyspnoea (80%), followed by constitutional symptoms (45.7%), embolization (30%), palpitation (25.7%), syncope (15.7%), pedal oedema (15.7%) and pain chest (12.9%). The sites of myxomas were as follows: left atrium, 58; right atrium, 9; and, biatrium, 3. All myxomas except 3 were attached to the interatrial septum. The site, size, shape, attachment, mobility, prolapse into ventricle, and surface characteristic of myxomas were accurately assessed by 2D-echocardiography and confirmed in all (65 of 70) who underwent surgery. When the morphological characteristic of myxomas were studied and correlated with clinical features large left atrial myxoma size was closely related with constitutional symptoms, congestive heart failure, with syncope and auscultatory findings suggestive of mitral valve disease, whereas smaller myxoma size and irregular surface were associated with embolization. Constitutional symptoms were only present in left atrial myxoma. Post-operative mean echocardiographic follow-up of 60 months showed no recurrence except in 2 with familial myxoma. We conclude that the majority of myxomas mimic many cardiovascular diseases and were detected in symptomatic patients, so a high index of clinical suspicion is important for its early and correct diagnosis. The size and appearance of the myxomas correlated with the presenting symptoms.

Adolescent↗

Long-term outcome of intracoronary microstent implantation: lesion matched comparison with Palmaz-Schatz stent.

We performed a lesion matched comparison of AVE Microstent and Palmaz-Schatz stent implants with 6 month follow-up angiography to compare the occurrence of restenosis. Thirty-three pairs of lesions were matched for lesion location, ACC/AHA lesion type, reference diameter, lesion length, and angiographic descriptors. Age, sex, clinical profile, and indication for stenting were comparable. Quantitative coronary analysis before and after the procedure was comparable in the two groups but minimum lumen diameter (MLD) at follow-up was less with Microstent--2.01 +/- 1.01 mm than Palmaz-Schatz stent--2.43 +/- 0.96 mm (P = 0.05). Binary restenosis was present in 33% and 21% and was diffuse in 55% and 29% of the two groups, respectively. Typical angina at follow-up was more frequent with Microstent (36%) than Palmaz-Schatz stent (15%; P = 0.038). When implanted in lesions of similar complexity, Microstent yields similar post procedure angiographic results but smaller MLD at follow-up and more frequent angina than Palmaz-Schatz stent.

Adult↗

Balloon aortic valvuloplasty in young adults by antegrade, transseptal approach using Inoue balloon.

Transvenous, transseptal, antegrade balloon aortic valvuloplasty (BAV) was successfully performed in 16 consecutive young adults with noncalcific aortic stenosis using Inoue balloon catheter. There were 13 males and three females, with a mean age of 20.4 +/- 5.8 years (range 14-30 years). All the patients had normal left ventricular systolic function. All procedures were performed electively by the antegrade technique, except the initial index case in whom, the stenosed aortic valve could not be crossed retrogradely. Dilatation was performed using stepwise technique keeping the balloon:annulus ratio < or = 100% in all the cases. Transaortic peak systolic gradient decreased from 113.4 +/- 42.6 (range 70-210) mm Hg to 11.2 +/- 9.2 (range 4-32) mm Hg; P = 0.0005. Following BAV, three patients developed grade 2+ aortic regurgitation, who were managed medically. None of the patients developed tamponade, vascular complications, excessive bleeding, or thromboembolism. Significant left to right atrial shunt (Qp/Qs > or = 1.5:1) was observed in one case. The average procedure time was 20 +/- 8 min (range 18-35 min). On follow-up (n = 11 patients) at 4 +/- 1.5 months (range 2-7 months) all the patients were asymptomatic. Doppler transaortic peak systolic gradient was found to be 15 +/- 10.3 mm Hg (range 4-36 mm Hg). Antegrade BAV technique using Inoue balloon for noncalcific aortic stenosis in young adults is safe, effective and may be technically advantageous.

Adolescent↗

Crosswire for recanalization of total occlusive coronary arteries.

Coronary angioplasty of total occlusions is technically difficult and is associated with limited success rates. The procedural outcome is mainly determined by the underlying pathological process. Recanalization of total occlusions is aimed at finding the passage with least resistance, without causing dissection or perforation. Several techniques have been advocated to improve the overall success rate. Recently, a new 0.014" Nitinol wire (Crosswire, Terumo) has been introduced as a tool, to achieve higher success rates for total occlusion angioplasty. The wire consists of an extremely flexible Nitinol-core, a platinum/iridium coil at the distal tip, and a hydrophilic polymer coating. Balloon angioplasty was attempted in 30 totally occluded coronary arteries with mean age of occlusion being 5 +/- 4 months (range 2-14 months). The initial five procedures were performed following failure of the conventional angioplasty guidewires. Subsequently, Cross-wire was used electively in all the cases. The lesion was crossed successfully in 90% (27/30) cases. Dissection of the coronary artery with subintimal entry was seen in two (7%) cases, and the rest (three cases) could not be crossed. Balloon angioplasty and stenting (n = 21) were performed with good immediate angiographic results. There were no myocardial infarctions or deaths. Fourteen of 16 patients, who had completed 6 months follow-up, were asymptomatic. Angiographic evidence of in-stent restenosis was demonstrable in one case. Successful recanalization of total coronary occlusions by using Cross-wire can be expected in 83% cases, with reasonable safety.

Adult↗

Percutaneous balloon aortic valvuloplasty during pregnancy: use of the Inoue balloon and the physiologic antegrade approach.

We describe the use of the Inoue balloon to dilate the aortic valve by the physiologic antegrade route during pregnancy. A 27-year-old pregnant woman with severe aortic stenosis presented with progressive dyspnea and presyncope at 26 weeks of pregnancy. She subsequently underwent percutaneous valvuloplasty by the antegrade route utilizing the transseptal puncture. We conclude that percutaneous antegrade balloon valvuloplasty by the Inoue balloon (venous approach) is a safe and effective procedure. It markedly reduces fluoroscopy and is a palliative procedure that allows pregnancy to continue.

Adult↗

Recurrent pseudoaneurysm of the left ventricle with subcutaneous herniation into the chest wall. A case report.

Pseudoaneurysm of the left ventricle is rare, and recurrence is extremely rare. We report the case of a 62-year-old man who presented at our hospital with a painless pulsatile swelling in the left breast. He had undergone coronary artery bypass grafting and left-ventricular aneurysmectomy 14 years earlier. On investigation, the swelling was diagnosed to be a pseudoaneurysm of the left ventricle with subcutaneous herniation. The extreme rarity of this condition prompted us to report the case. The investigative techniques and the surgical strategy are discussed.

Aneurysm, False↗

Comparative evaluation of transthoracic and transesophageal echocardiography in detection of left atrial thrombus before percutaneous transvenous mitral commissurotomy. Do all patients need transesophageal examination?

We postulated that the sensitivity of transthoracic echocardiography in detection of left atrial cavity or appendage thrombi is better in south-east asian patients with rheumatic mitral stenosis. This was considering that these patients are generally younger, have lesser body weight and thinner chest walls resulting in better transthoracic echogenecity than their western counterparts. We prospectively performed transthoracic and transoesophageal echocardiography in 150 consecutive Indian patients (mean age 28.8+/-7.2 years; 78 men) being evaluated for percutaneous transvenous mitral commissurotomy. The overall sensitivity of transthoracic echocardiography was 74% (95% C.I. 59-88%). This was significantly higher than the pooled estimate from five western reports which evaluated similar patients (overall sensitivity 12%; 95% C.I. 0-25%; P<0.0001). The sensitivity rose to 83% when patients with poor echogenecity were excluded. Amongst patients with good echogenecity (81% patients) the diagnosis of left atrial thrombi was correctly made or suspected on transthoracic examination in all patients subsequently shown to have thrombi on transoesophageal echocardiography. Significant savings in cost may be safely achieved by limiting transoesophageal echocardiography to patients in whom left atrial cavity or appendage is not adequately visualized on transthoracic examination due to poor echogenecity, or in whom there are shadows suggestive but not diagnostic of thrombi.

Adolescent↗

Effects of supplementation with iloprost on the cardioprotection by BW755C (a dual inhibitor of cyclooxygenase and lipoxygenase enzymes) in myocardial reperfusion injury.

The effect of BW755C (a dual inhibitor of cyclo- and lipoxygenase enzymes) alone and in combination with iloprost (a PGI2 analogue) on myocardial reperfusion injury was investigated in anaesthetised open-chest dogs. The left anterior descending coronary artery was occluded for a period of 40 min followed by reperfusion for 3 h. Dogs were administered either saline, BW755C (10 mg kg-1 slow bolus) or BW755C plus iloprost (100 ng kg-1 min-1 for 75 min) just prior to reperfusion. The haemodynamic data showed significant reduction in MAP and both LV peak-positive and peak-negative dP/dt following reperfusion in the saline-treated group, along with a delayed recovery of LVEDP. These changes were accompanied by significant depletion of myocardial ATP and glycogen stores. Administration of BW755C prevented the haemodynamic changes and replenished the HEP stores. Although coadministration of iloprost with BW755C afforded early normalisation of LVEDP and LV peak positive dP/dt, but MAP and LV peak negative dP/dt remained significantly depressed. Therefore, it might be concluded from this study that supplementation of BW755C with iloprost may have deleterious haemodynamic effects on the reperfused myocardium, particularly in the doses used.

4,5-Dihydro-1-(3-(trifluoromethyl)phenyl)-1H-pyraz↗

Lack of any additional benefit in combining aspirin with iloprost in a canine model of myocardial reperfusion injury.

The effects of iloprost infusion (100 ng/kg/min for 75 min) alone and in combination with aspirin (3 mg/kg IV bolus) were compared in a canine model of myocardial reperfusion injury. Regional ischemia of 40 min was produced by temporary occlusion of the left anterior descending coronary artery, after which the myocardium was reperfused for a period of 3 hours. Mean arterial pressure (MAP), heart rate (HR), left ventricular end diastolic pressure (LVEDP), positive (+) LVdP/dtmax and negative (-) LVdP/dtmax were monitored. Rate pressure product and (-) dP/dt/Pmax were also derived from the above. Myocardial tissue levels of adenosine triphosphate (ATP), creatine phosphate (CP), glycogen and lactate were estimated. Following reperfusion in the saline treated group, there was a significant fall in (i) MAP, (ii) (+) LVdP/dtmax and (iii) (-) LVdP/dtmax. LVEDP was corrected about 2 hours after reperfusion. Despite correction of lactate accumulation, ATP and glycogen were not restored although the CP store was replenished. The hemodynamic profiles in both iloprost and in combination treated groups were similar; (i) depressed MAP (particularly during iloprost infusion) without any significant change in HR (ii) no significant depression in (+) LVdP/dtmax (iii) depression in (-) LVdP/dtmax but not when corrected for lower Pmax and (iv) a significant reduction in the incidence of reperfusion arrhythmias. Similarly, in both the drug/s treated groups, ATP, CP and lactate were normalised although glycogen store was not restored. The results of this study indicate (i) cardioprotective effect of iloprost even when administered prior to reperfusion and (ii) no additional protective effect of combining iloprost and aspirin.

Adenosine Triphosphate↗