Search PubMed⌕ Search

Biomedical subjects

S C Liew

Publications and source records attributed to S C Liew.

20 records · Page 2Linked to original sources

Anisotropic elasticity of bovine pericardial tissues.

Artificial heart valves fashioned from bovine pericardial tissues appear to perform favourably when compared to those fashioned from other biological materials. Tissue mechanical properties have been implicated as a possible factor in determining the success or failure of the materials used for constructing tissue valve substitutes. In this study, strips of bovine pericardial tissues, cut in three different directions (along the base-apex axis of the heart, perpendicular to this axis and at an angle of 45 degrees to this axis), were subjected to uniaxial tensile tests using an Instron machine, at strain rates of 666.7, 166.7, 66.7, and 6.7% X min-1. The pericardial tissues were found to have non-linear stress-strain curves. Anisotropy was also observed, in that the tissue was most extensible when stretched along the vertical direction and least extensible when stained along the horizontal direction. The tissues also exhibited viscoelastic properties, as the extensibility was found to decrease with the increasing strain-rate. The strain at rupture for these tissues, however, were found to be independent of the strain rates and the direction in which they were stretched. On the other hand the stress at rupture was largest when stretched in the horizontal direction and least when stretched in the vertical direction. Stresses at rupture also increase with the strain rate. The implications of the observed tissue properties, when these are used in the fashioning of tissue valve substitutes, will be discussed.

Animals↗

Noise, resolution, and sensitivity considerations in the design of a single-slice emission-transmission computed tomographic system.

A prototype Emission-Transmission Computed Tomography (ETCT) system is being developed that will acquire single-slice x-ray transmission CT images simultaneously with single photon emission computed tomography (SPECT) images. This system will permit the correlation of anatomical information from x-ray CT with functional information from SPECT images. The patient-specific attenuation map derived from the x-ray CT images can be used to perform attenuation correction of the SPECT images, so that accurate quantitative information can be obtained. The fan-beam scanning geometry and the use of a segmented HPGe detector array impose special constraints on the design of the collimator for the system. Based on a signal detection model, an efficiency-resolution figure of merit (ERFM) as a function of the collimator geometric efficiency, system resolution width, and object diameter is defined. The ERFM is proportional to the square of the detection signal-to-noise ratio. The collimator design parameters can then be optimized by optimizing the ERFM for an anticipated object diameter. The collimator point-spread function, geometric efficiency, and resolution are calculated. The collimator optimized for the detection of a 1-cm object will have a single-slice point source efficiency of 1.2 X 10(-4), and a FWHM of 6.5 mm at the center of the reconstruction circle, at 12 cm from the collimator face. The minimum object contrast which will give a detection SNR of 5 is 74%, for a total accumulated count per slice of 2 X 10(6).

Humans↗