Search PubMed⌕ Search

Biomedical subjects

S C Horii

Publications and source records attributed to S C Horii.

At least 19 recordsLinked to original sources

The effect of PACS on the time required for technologists to produce radiographic images in the emergency department radiology suite.

The purpose of this study was to evaluate the effect of a switch to a filmless image management system on the time required for technologists to produce radiographic images in the emergency department (ED) after controlling for exam difficulty and a variable workload. Time and motion data were collected on patients who had radiographic images taken while being treated in the emergency department over the 3 1/2-year period from April 1997 to November 2000. Event times and demographic data were obtained from the radiology information system, from the hospital information system, from emergency department records, or by observation by research coordinators. Multiple least squares regression analysis identified several independent predictors of the time required for technologists to produce radiographic images. These variables included the level of technologist experience, the number of trauma-alert patient arrivals, and whether a filmless image management system was used (all P <.05). Our regression model explained 22% of the variability in technologist time (R2 Adjusted, 0.22; F = 24.01; P <.0001). The regression model predicted a time saving of 2 to 3 minutes per patient in the elapsed time from notification of a needed examination until image availability because of the implementation of PACS, a delay of 4 to 6 minutes per patient who were imaged by technologists who spent less than 10% of their work assignments within the ED, and a delay of 18 to 27 minutes in radiology workflow because of the arrival of a trauma alert patient. A filmless system decreased the amount of time required to produce radiographs. The arrival of a trauma alert patient delayed radiology workflow in the ED. Inexperienced technologists require 4 to 6 minutes of additional time per patient to complete the same amount of work accomplished by an experienced technologist.

Allied Health Personnel↗

From being a radiologist to watching a radiologist: impact of filmless operation on the training of radiology residents.

RATIONALE AND OBJECTIVES: The authors performed this study to investigate the impact of changing from a film-based image interpretation system to one using digital image workstations on the training of radiology residents in the interpretation of radiographs. MATERIALS AND METHODS: Data were collected during a period when a conventional system of image interpretation with hard-copy images and multiviewers was used and during a period when digital image workstations were used. During each period, it was noted whether the first interpretation of the radiographs was performed by a radiology resident, by an attending radiologist, or as a group effort including both an attending radiologist and a radiology resident(s). In addition, it was noted whether a radiology resident or an attending radiologist dictated the report. RESULTS: The proportion of images first interpreted by the radiology resident alone decreased from 38% (53 of 139) when using the conventional system to 17% (34 of 199) after the switch to interpreting images on the workstations (P = .001). During the film-based period, radiology residents dictated 45% of reports (141 of 312), but during the workstation period, radiology residents dictated only 4% of reports (24 of 667; P = .001). CONCLUSION: The authors observed a decrease in autonomous participation by radiology residents in image interpretation and dictation of reports and an increase in "group reading" after the switch from a film-based system to a workstation system.

Humans↗

Sonographic appearance of focal thyroiditis.

OBJECTIVE: The purpose of this study is to report the sonographic appearance of focal thyroid nodules that prove to be lymphocytic thyroiditis on fine-needle aspiration. CONCLUSION: In a patient population undergoing sonography for palpable nodular disease without known thyroiditis, focal nodules of thyroiditis had a wide variety of appearances. They most commonly appeared as solid hyperechoic nodules with ill-defined margins. However, the echogenicity was variable, and calcification and cystic-appearing regions were also noted. The vascularity of these nodules as assessed with color Doppler and power Doppler sonography also varied widely. Biopsy of these lesions is still necessary because there are no sonographic features that can reliably diagnose these lesions as thyroiditis and differentiate them from other lesions.

Biopsy, Needle↗

Radiology workflow and patient volume: effect of picture archiving and communication systems on technologists and radiologists.

This study was performed to evaluate the changes in workflow and efficiency in various clinical settings in the radiology department after the introduction of a picture archiving and communication system (PACS). Time and motion data were collected when conventional image management was used, and again after the introduction of a PACS. Changes in the elapsed time from examination request until the image dispatch to the radiologist, and from dispatch until report dictation, were evaluated. The relationship between patient volume and throughput was evaluated. The time from examination request until dispatch was significantly longer after the introduction of PACS for examinations taken on patients from the emergency department (ED) (pre-PACS, 20 minutes; post-PACS, 25 minutes; P < .0001), and for examinations taken on patients in the medical intensive care unit (MICU) (pre-PACS, 34 minutes; post-PACS, 42 minutes; P < .0001). The interval from image dispatch until report dictation shortened significantly after the introduction of PACS in the ED (pre-PACS, 38 minutes; post-PACS, 23 minutes; P < .0001) and in the outpatient department (OPD) (pre-PACS, 38 minutes; post-PACS, 20 minutes; P < .0001). Simple least squares regression showed a significant relationship between daily patient volume and the daily median time until report dictation (F = 43.42, P < .001). PACS slowed technologists by prolonging the quality-control procedure. Radiologist workflow was shortened or not affected. Efficiency is dependent on patient volume, and workflow improvements are due to a shift from batch to on-line reading that is enabled by the ability of PACS to route enough examinations to keep radiologists fully occupied.

Appointments and Schedules↗

A picture archival and communication system shortens delays in obtaining radiographic information in a medical intensive care unit.

OBJECTIVE: To assess whether variables such as unit occupancy and aggregate severity of illness that reflect increased work demands on physicians in medical intensive care units (MICU) are associated with increased delays in their obtaining information about nonroutine chest radiographic examinations. To determine whether the presence of a picture archiving and communication system (PACS) workstation in the MICU shortens those delays. DESIGN: A prospective cohort study stratified for presence or absence of PACS. SETTING: MICU of a university hospital. PATIENTS: A total of 118 patients admitted to the MICU who had nonroutine bedside chest radiographs. MEASUREMENTS AND MAIN RESULTS: Multivariate analyses were conducted to determine how unit occupancy, patient acuity, the time of day the examination was taken, and the presence of a PACS workstation influenced the time from radiographic examination completion to the time when MICU physicians first obtained image information. In a multivariate analysis, patient acuity, unit occupancy, the aggregate level of severity of illness in the study cohort, whether the examination was taken at night or day, and the presence of a PACS workstation were significant predictors of the elapsed time from examination completion until review by MICU physicians. Without the PACS workstation, higher occupancy, higher aggregate severity of illness, and examinations taken during the day were associated with longer delays. Overall, the multivariate analysis showed a 24-min decrease in the elapsed time to obtain information during periods with the PACS workstation compared with periods without the workstation (p = .03). CONCLUSIONS: A PACS workstation significantly decreased the delays in obtaining image information that occurred with high unit occupancy and high aggregate severity of illness and may improve unit efficiency under conditions of high physician workload.

APACHE↗

Sonography during early pregnancy: dependence of threshold and discriminatory values on transvaginal transducer frequency.

OBJECTIVE: Our goal was to determine if normal and abnormal pregnancies could be distinguished at smaller sac sizes with a higher frequency transvaginal transducer than with a 5-MHz transducer. SUBJECTS AND MATERIALS: Thirty-nine patients with potentially abnormal pregnancies identified with a 5-MHz transvaginal transducer were immediately reimaged with a 9-5-MHz transducer. We compared our ability to visualize the yolk sac, embryo, and cardiac activity relative to mean sac diameter on imaging at both frequencies in women with normal and abnormal pregnancies. RESULTS: Of the 39 pregnancies, 22 (56%) were normal or probably normal. Using the 5-MHz transducer, a yolk sac was first seen in a 6.4-mm gestational sac but was not definitively seen in 12 gestational sacs measuring 5-13 mm. Using the 9-5-MHz transducer, yolk sacs were identified in all gestational sacs measuring 4.6-13 mm, and live embryos were seen in five of eight sacs measuring 8.1-13 mm. The largest normal gestational sac without a live embryo measured 11 mm. When we compared these pregnancies with 17 (44%) abnormal pregnancies, we found that all pregnancies that had no yolk sac by the time the gestational sac measured 5.0 mm or no live embryo by 13 mm had abnormal findings on higher frequency imaging. CONCLUSION: The ability to visualize the yolk sac and embryo in early pregnancy is critically dependent on transvaginal transducer frequency. Threshold values and discriminatory sizes used to distinguish normal and abnormal pregnancies are smaller on higher frequency than on lower frequency imaging and, therefore, should be redetermined for specific transducer frequencies.

Adolescent↗

Diagnostic criteria for fatty infiltration of the liver on contrast-enhanced helical CT.

OBJECTIVE: The purpose of the study was to develop quantitative and qualitative criteria for diagnosing fatty liver on contrast-enhanced helical CT. SUBJECTS AND METHODS: Differential liver-spleen attenuation was evaluated between 80 and 120 sec after injection in 76 patients who underwent contrast-enhanced helical CT. Unenhanced CT images had earlier established fatty liver when the liver minus spleen attenuation difference was less than or equal to -10 H (n = 18). Four observers who had not seen the unenhanced images used contrast-enhanced CT images to assess the presence of fatty liver on a five-point Likert scale, the presence of geographic areas spared from fatty infiltration, and the relative liver-spleen attenuation. The diagnostic accuracies of various imaging criteria were compared using McNemar's chi-square test (for sensitivity and specificity) and analysis of receiver operating characteristic curves. RESULTS: Sensitivity, specificity, and receiver operating characteristic curve areas for observers' qualitative judgments were 54%, 95%, and .91, respectively; for quantitative differential liver-spleen attenuation (80-100 sec; -20.5 H discriminatory value), the values were 86%, 87%, and .94, respectively; and for quantitative differential liver-spleen attenuation (101-120 sec; -18.5 H discriminatory value), the values were 93%, 93%, and .98, respectively. Differential liver-spleen attenuation was time-dependent; overlap was noted between healthy subjects and patients with fatty liver. Qualitatively, geographic sparing was highly specific (94%) for fatty liver, whereas liver attenuation greater than or equal to spleen attenuation excluded fatty liver in all but one case. CONCLUSION: Although quantitative and qualitative criteria for diagnosing fatty liver on helical CT can be determined, they are protocol-specific. Limited unenhanced hepatic CT remains the optimal technique for detection of fatty infiltration of the liver.

Contrast Media↗

Post-cesarean section pain secondary to intussuscepting colonic adenocarcinoma.

The differential diagnosis for lower abdominal and pelvic pain following Cesarean section includes many causes, such as endometritis, abscess, pelvic hematoma, wound complications, pelvic vein thrombophlebitis, gastrointestinal dysfunction and obstruction. Colonic obstruction secondary to intussusception is a rare cause. We present a case of post-Cesarean section pain in a 26-year-old patient due to obstructing colonic intussusception secondary to colonic adenocarcinoma. Review of the literature failed to identify a previous case report of colonic adenocarcinoma with intussusception presenting early in the postpartum period. The diagnosis was initially made by ultrasound, and later corroborated by computed tomography, barium enema and laparotomy.

Adenocarcinoma↗

First-trimester US parameters of failed pregnancy.

PURPOSE: To test the reliability of established ultrasound (US) parameters in predicting the outcome of first-trimester pregnancy. MATERIALS AND METHODS: The authors retrospectively reviewed 2,655 first-trimester US scans in 2,285 patients. Parameters tested against outcome were (a) a yolk sac and mean gestational sac diameter of 8 mm on transvaginal US scans, (b) an embryo and mean sac diameter of 16 mm on transvaginal US scans, and (c) a difference between the mean sac diameter and crown-rump length of less than 5 mm (oligohydramnios) at 5.5-9.0 weeks gestation. RESULTS: Thirty (22%) of 135 patients without yolk sacs and with an 8-mm mean sac diameter developed live embryos: 24 had normal follow-up or delivery; six were lost to follow-up. Five (8%) of 59 patients with no depiction of embryos and with a 16-mm mean sac diameter developed live embryos: Two delivered, one spontaneously aborted, one had death of one twin embryo before being lost to follow-up, and one was lost to follow-up. Seventeen (0.74%) of 2,285 patients had early oligohydramnios: Six (35%) had normal follow-up scans or delivery, two (12%) spontaneously aborted, and nine (53%) were lost to follow-up. CONCLUSION: Established parameters predictive of early pregnancy failure potentially result in misdiagnosis of nonviability or poor prognosis when applied to a large, unselected patient population. Close follow-up is necessary in cases with borderline abnormal findings.

Abortion, Spontaneous↗

Modular extension of the ACR-NEMA DICOM standard to support new diagnostic imaging modalities and services.

The American College of Radiology-National Electrical Manufacturers Association (ACR-NEMA) Standard for Digital Imaging and Communications in Medicine (DICOM) (NEMA PS3-1993, DICOM) enables interconnection of imaging equipment and exchange of diagnostic images over standard networks. The widespread adoption of DICOM by industry and the benefits of standardized image management have attracted international attention. Other medical specialties, dentistry, and veterinary medicine have indicated strong interest in extending the DICOM Standard to support nonradiological image modalities. Parts 1 through 9 of DICOM were published in 1992 and 1993. Additional features developed in response to requests from the user community are being added in DICOM Supplements. The ACR, NEMA, and committees from other medical specialties working under the coordination of the American National Standards Institute Healthcare Informatics Standards Planning Panel Message Standards Developers Subcommittee Joint Working Group for Diagnostic Image Communication have defined new image object classes to support X-Ray Angiography, Radio-Fluoroscopy, Positron Emission Tomography, Endoscopy, and Light Microscopy. ACR-NEMA has also developed new service classes for Storage Commitment and Worklist Management. In joint work with the standards development committee of the Japanese Industries for Radiation Apparatus and the Japanese Medical Information System Development Center, ACR-NEMA has developed specifications for multibyte character set support and for a DICOM file format for transportable media. Other work is in progress. New DICOM features have provided and can continue to provide significant new functionality for digital image management systems. The demonstrated capability of efficient extension of the base standard is evidence of the effectiveness of the object oriented strategy of DICOM.

Diagnostic Imaging↗

Prospective study of a PACS: information flow and clinical action in a medical intensive care unit.

PURPOSE: To prospectively compare efficiency and outcome of a standard film-only system with those of a digital picture archiving and communication system (PACS). MATERIALS AND METHODS: The film-only system, which used either analog film or computed radiography (CR) hard copy, was compared with a PACS, which used CR images displayed on a multiviewer in the radiology department and a workstation in the medical intensive care unit. A random sample of nonroutine, bedside chest radiographs was studied. RESULTS: Within 20 minutes of completion of radiography, 246 of 328 (75%) of the images were available at the workstations; it took 1.8 hours for 238 of 317 (75%) of the images to be displayed on the multiviewer. When the workstation was used, the staff did not access the image information earlier, but clinical actions were initiated more promptly in response to imaging findings. Consultation with radiologists decreased from 507 of 561 (90%) images with hard copies to 70 of 249 (28%) with the workstation. CONCLUSION: Use of a PACS improves the delivery of chest images, facilitates the initiation of clinical actions, and decreases input by radiologists.

Computer Systems↗

Image acquisition. Sites, technologies, and approaches.

This article examines the current and future methodologies for image capture. Data conversion devices and systems, radiographic techniques of ionizing and nonionizing radiation, passive imaging, and digital image data requirements are explored. The author also discusses the problem of how to connect acquisition devices to PACS.

Analog-Digital Conversion↗

High-resolution image workstation for intensive care units.

Despite their potential for improving patient management and decreasing costs, picture archiving and communication systems (PACS) are not being absorbed rapidly into clinical practice because of their technical immaturity and because the cost-effectiveness of the technology has not been established. Workstations and archives need to be significantly improved before they can be useful. This report describes the authors' experiences with a high-resolution image workstation for a medical intensive care unit. The workstation has been designed around a standard computer platform and is equipped with two high-resolution image displays. The user interface stresses speed and simplicity. Image manipulation is simplified by providing empirical preset window and level values. Images are displayed in less than 2 seconds. The workstation also displays radiologic reports as soon as they become available. Future work will focus on using the workstation to improve communication between the physician and the radiologist.

Humans↗

Laparoscopic cholecystectomy. Postoperative sonographic findings.

Seventeen consecutive patients undergoing elective laparoscopic cholecystectomy (LC) were serially evaluated with transabdominal ultrasound before, one day after, and six days after LC to document what, if any, changes occur in the surgical bed and surrounding parenchyma. The most common postoperative finding was focal sonolucency in the hepatic parenchyma adjacent to the gallbladder fossa in six (35%) of 17 patients. Five patients (29%) had postoperative fluid collections in the gallbladder fossa; in four of these five, it was technically difficult to dissect the gallbladder from the liver at the time of original surgery. In one patient the fluid resolved by the sixth postoperative day. It persisted in the remaining four. Two patients had transient ductal dilation and one had pneumobilia. Shadowing and ring-down artifact was identified in 12 patients due to surgical clips in the triangle of Calot. Because gallbladder fossa fluid may persist up to six days after uncomplicated laparoscopic cholecystectomy, caution should be used before attaching significance to isolated imaging findings. Clinical judgement remains the best means of selecting which patients need additional evaluation.

Abdomen↗

Improving the distinction between benign and malignant breast lesions: the value of sonographic texture analysis.

To improve the ability of ultrasound to distinguish benign from malignant breast lesions, we used quantitative analysis of ultrasound image texture. Eight cancers, 22 cysts, 28 fibroadenomata, and 22 fibrocystic nodules were studied. The true nature of each lesion was determined by aspiration (for some cysts) or by open biopsy. Analysis of image texture was performed on digitized video output from the ultrasound scanner using fractal analysis and statistical texture analysis methods. The most useful features were those derived from co-occurrence matrices of the images. Using two features together (contrast of a co-occurrence matrix taken in an oblique direction, and correlation of a co-occurrence matrix taken in the horizontal direction), it was possible to exclude 78% of fibroadenomata, 73% of cysts, and 91% of fibrocystic nodules while maintaining 100% sensitivity for cancer. These findings suggest that ultrasonic image texture analysis is a simple way to markedly reduce the number of benign lesion biopsies without missing additional cancers.

Adolescent↗