Global right atrial mapping of human atrial flutter: the presence of posteromedial (sinus venosa region) functional block and double potentials : a study in biplane fluoroscopy and intracardiac echocardiography.

BACKGROUND: Previous studies of atrial flutter have found linear block at the crista terminalis; this was thought to predispose the patient to the arrhythmia. More recent observations, however, have demonstrated crista conduction. We sought to characterize the posterior boundary of atrial flutter. METHODS AND RESULTS: Patients with counterclockwise flutter (n=20), clockwise flutter (n=3), or both (n=5) were studied using two 20-pole catheters. Biplane fluoroscopy determined catheter positions. During counterclockwise flutter, craniocaudal activation occurred along the entire lateral and posterior right atrial walls. Septal activation proceeded caudocranially. In all patients, a line of block was seen in the posteromedial (sinus venosa) right atrium; this was manifested by the presence of double potentials where the upward and downward activations collided. Anatomic location was confirmed by intracardiac echocardiography in 9 patients. In patients with clockwise flutter, the line of block and double potentials were seen in the same location during counterclockwise flutter, but the activation sequence around the line of block was reversed. Pacing near the site of double potentials during sinus rhythm excluded a fixed line of block, and premature atrial complexes demonstrated functional block with manifest double potentials. In 2 patients, posterior ectopy organized to subsequently initiate isthmus-dependent atrial flutter. CONCLUSIONS: (1) A functional line of block is seen at the posteromedial (sinus venosa region) right atrium during counterclockwise and clockwise atrial flutter. (2) All lateral wall right atrial activation can be uniform during flutter, without linear block or double potentials in the region of the crista terminalis. (3) Activation at the site of posteromedial right atrial functional block can organize to subsequently initiate isthmus-dependent atrial flutter.

Adult

Distinct hemodynamic profiles in patients with vasovagal syncope: a heterogeneous population.

OBJECTIVE: The objective was to investigate mechanisms of vasovagal syncope by identifying laboratory techniques that characterize cardiovascular profiles in patients with vasovagal syncope. BACKGROUND: The triggering mechanisms of vasovagal syncope are complex. The patient population is likely heterogeneous. We hypothesized that distinct hemodynamic profiles are definable with provocative maneuvers. METHODS: Three groups of subjects were matched for age and gender: 16 patients with a history of syncope and an inducible vasovagal response during passive tilt table testing (70 degrees, 45 min, group I), 16 with a history of syncope, negative passive tilt table testing but positive isoproterenol tilt table testing (0.05 microg/kg per min, 70 degrees, 10 min, group II), and 16 control subjects. Beat-to-beat hemodynamic functions were determined noninvasively by photo-plethysmography and impedance cardiography. RESULTS: At baseline, hemodynamic functions were not different among the three groups (supine). In response to tilt before any symptoms developed, total peripheral resistance decreased 9% +/- 14% in group I from baseline supine to tilt position but increased 27% +/- 18% in group II and 28% +/- 17% in controls (p < 0.001). Responses to isoproterenol were not significantly different between group II and controls in supine position. In response to tilt during isoproterenol infusion before any symptoms developed, total peripheral resistance decreased 24% +/- 20% in group II and increased 20% +/- 48% in controls (p = 0.002). CONCLUSIONS: Group I patients may have impaired ability to increase vascular resistance during orthostatic stress. The inability to overcome isoproterenol-induced vasodilatation during tilt is important in triggering a vasovagal response in group II patients. These data suggest that the population with vasovagal response is heterogeneous. Distinct hemodynamic profiles in response to various provocative maneuvers are definable with noninvasive, continuous monitoring techniques.

Adult

Are routine arrhythmia inductions necessary in patients with pectoral implantable cardioverter defibrillators?

INTRODUCTION: The value of ventricular arrhythmia inductions as part of routine implantable cardioverter defibrillator (ICD) follow-up in new-generation pectoral ICDs is unknown. METHODS AND RESULTS: We performed a retrospective analysis of a prospectively collected database analyzing data from 153 patients with pectoral ICDs who had routine arrhythmia inductions at predismissal, and 3 months and 1 year after implantation. Routine predismissal ventricular fibrillation (VF) induction yielded important findings in 8.8% of patients, all in patients with implantation defibrillation threshold (DFT) > or = 15 J or with concomitant pacemaker systems. At 3 months and 1 year, routine VF induction yielded important findings in 5.9% and 3.8% of tested patients, respectively, all in patients who had high DFT on prior testing. Ventricular tachycardia (VT) induction at predismissal, and 3 months and 1 year after implantation resulted in programming change in 37.4%, 28.1%, and 13.8% of tested patients, almost all in patients with inducible VT on baseline electrophysiologic study and clinical episodes since implantation. CONCLUSION: Although helpful in identifying potentially important ICD malfunctions, routine arrhythmia inductions during the first year after ICD implantation may not be necessary in all cases. VF inductions have a low yield in patients with previously low DFTs who lack concomitant pacemakers. VT inductions have a low yield in patients without baseline inducible VT and in the absence of clinical events. Definite recommendations regarding patient selection must await larger prospective studies as well as consensus in the medical community about what comprises an acceptable risk justifying avoidance of the costs and inconveniences of routine arrhythmia inductions.

Adolescent

Catheter ablation of mitral isthmus ventricular tachycardia using electroanatomically guided linear lesions.

Mitral isthmus ventricular tachycardia uses a reentrant circuit with a critical isthmus of conduction bounded by the mitral valve proximally and a remote inferior infarction scar distally. Successful catheter ablation requires placement of a lesion to transect the isthmus so as to prevent wavefront propagation. We report a case with previously unsuccessful ablation in which focal isthmus ablation failed to eliminate arrhythmia. Electroanatomic mapping demonstrated a wide tachycardia isthmus, and a linear lesion placed from the edge of the inferior infarct (as demonstrated on the three-dimensional voltage electroanatomic map) to the base of the mitral valve successfully eliminated tachycardia. In some patients with mitral isthmus VT, a wide isthmus requires linear lesion placement to fully transect the isthmus and eliminate tachycardia. Electroanatomic mapping can be used to define isthmus boundaries and thus guide successful ablation.

Body Surface Potential Mapping

Utility of a single-stage isoproterenol tilt table test in adults: a randomized comparison with passive head-up tilt.

OBJECTIVES: This study was conducted to develop a time-efficient tilt table test. BACKGROUND: Current protocols of tilt table testing are quite time-consuming. This study was designed to assess the diagnostic value, tolerance and procedural time of a single-stage isoproterenol tilt table protocol. METHODS: A single-stage isoproterenol tilt table test was compared with the passive tilt table test. The study was prospectively designed in a randomized and crossover fashion. RESULTS: The study population consisted of 111 patients with a history of syncope (mean age 55 +/- 20 years). Of the total, 62 patients (56%; 95% confidence interval, 46% to 65%) had a positive vasovagal response during isoproterenol tilt table testing and 35 (32%; 23% to 41%) during passive tilt table testing (p = 0.002). The mean procedural times of the study population were 11.7 +/- 3.6 min and 36.9 +/- 13.3 min for isoproterenol and passive tilt table testing, respectively (p < 0.001). All patients tolerated single-stage isoproterenol testing. In the 23 control subjects (mean age 34 +/- 11 years), the apparent specificities were 91% (72% to 99%) and 83% (61% to 99%) for passive and single-stage tilt table testing, respectively. CONCLUSIONS: The single-stage isoproterenol tilt table test was more effective in inducing a positive vasovagal response in an adult population than the standard passive tilt table test, and it significantly reduced the procedural time. The increase in positive yield was associated with a moderate decrease in apparent specificity. These observations support the conclusion that single-stage tilt table testing could be a reasonable diagnostic option in patients undergoing syncope evaluation.

Adult

A stepwise testing protocol for modern implantable cardioverter-defibrillator systems to prevent pacemaker-implantable cardioverter-defibrillator interactions.

Current use of newer implantable cardioverter-defibrillators (ICDs) has changed the spectrum of pacemaker-ICD interactions and provided new tools for testing and understanding those interactions. Testing for pacemaker-ICD interactions was performed in 31 procedures involving 22 patients. The protocol included: (1) evaluation of pacemaker stimulus artifact amplitude and its ratio to that of the evoked ventricular electrogram, (2) testing for inhibition of ventricular fibrillation (VF) detection by the ICD during asynchronous pacing at maximum output, (3) evaluation by pacemaker event marker recordings of pacemaker sensing behavior while programmed to nonasynchronous mode during ventricular tachycardia (VT) or VF, and (4) evaluation of postshock interactions. Inhibition of detection of VT/VF was found in 6 of 22 patients (27.2%). Large stimulus artifact amplitude (>2 mV) or stimulus artifact:evoked QRS ratio > 1/3 had a positive predictive accuracy of 18% and 14.4%, respectively, and a negative predictive accuracy of 100% and 92.3%, respectively, for clinically significant interaction. Asynchronous pacing occurred in 16 of 31 procedures (51.6%), and was due to underdetection by the pacemaker in 4 of 16 (25%) and noise reversion in 12 of 16 (75%). Postshock phenomena occurred in 6 cases, 3 of which were clinically significant. Overall, 11 of 22 patients (50%) had clinically significant interactions discovered by this protocol, which led to system revisions in 6 and to pacemaker output reprogramming in 5. Thus, pacemaker-ICD interactions are frequently detected using a thorough and systematic protocol. Most cases can be managed by system revision or pacemaker reprogramming.

Artifacts

Relation between mode of pacing and long-term survival in the very elderly.

OBJECTIVES: This study analyzes the relationship between pacing mode and long-term survival in a large group of very elderly patients (> or = 80 years old). BACKGROUND: The relationship between pacing mode and long-term survival is not clear. Because the number of very elderly who are candidates for pacing is increasing, issues related to pacemaker (PM) use in the elderly have important clinical and economic implications. METHODS: We retrospectively reviewed 432 patients (mean age, 84.5+/-3.9 years) who received their initial PM (ventricular in 310 and dual chamber in 122) between 1980 and 1992. Follow-up was complete (3.5+/-2.6 years). Observed survival was estimated by the Kaplan-Meier method. Age- and gender-matched cohorts from the Minnesota population were used for expected survival. Log-rank test and Cox regression hazard model were used for univariate and multivariate analyses. RESULTS: Patients with ventricular PMs appeared to have poor overall survival compared with those with dual-chamber PMs. Observed survival after PM implantation in high grade atrioventricular block (AVB) patients was significantly worse than expected survival of the age- and gender-matched population (p < 0.0001), whereas observed survival of patients with sinus node dysfunction was not significantly different from expected survival of the matched population (p = 0.413). By univariate analysis, ventricular pacing in patients with AVB appeared to be associated with poor survival compared with dual-chamber pacing (hazard ratio [HR] 2.08; 95% confidence interval [CI] 1.33 to 3.33). After multivariate analysis, this difference was no longer significant (HR 1.41; 95% CI 0.88 to 2.27). Independent predictors of all-cause mortality were number of comorbid illnesses, New York Heart Association functional class, left ventricular depression and older age at implant. Pacing mode was not an independent predictor of overall survival. Older age at implantation, diabetes mellitus, dementia, history of paroxysmal atrial fibrillation and earlier year of implantation were independent predictors of ventricular pacemaker selection. CONCLUSIONS: After PM implantation, long-term survival among very elderly patients was not affected by pacing mode after correction of baseline differences. Selection bias was present in pacing mode in the very elderly, with ventricular pacing selected for sicker and older patients, perhaps partly explaining the apparent "beneficial impact on survival" observed with dual-chamber pacing.

Aged

The effect of intravenous procainamide on the HV interval at electrophysiologic study.

The His bundle electrogram recorded at electrophysiologic study clearly differentiates atrioventricular (AV) node disease from distal conduction system disease. The distal conduction system may be tested further by infusing procainamide (10-15 mg/kg) intravenously. High-grade distal AV block or prolongation of the HV interval <80 ms was defined as an abnormal response to this test. We retrospectively reviewed the medical records of 79 patients who underwent electrophysiologic study with intravenous procainamide. An abnormal response to procainamide was observed in only 3% of 37 patients with a normal baseline HV (</= ms), in 48% of 27 patients with mild HV prolongation (56 to 70 ms), and in all 15 patients with moderate HV prolongation (<70 ms) (P <0.0001 for the trend). Procainamide induced high-grade AV block in 4 of 28 patients (14%) studied for syncope and in 1 of 51 patients (2%) studied for ventricular tachycardia. Syncope as the indication for electrophysiologic study (P = 0.05) and left bundle branch block morphology (P = 0.03) were predictors of high-grade AV block; baseline HV and QTc intervals were significantly prolonged in patients who developed AV block with procainamide. We identified a strong linear correlation (R = 0.85) between post-drug and baseline HV intervals, with a regression slope of 1.17 +/- 0.09 and an intercept (+/- standard error) of 5.8 +/- 5.0 ms. This linear response to procainamide and published prospective studies support pacing syncope patients with baseline HV <70 ms. Therefore, procainamide infusion during the electrophysiologic study of patients with undifferentiated syncope should be reserved for those with mild HV prolongation from approximately 55 to 70 ms.

Aged

Increase in heart rate precedes episodes of ventricular tachycardia and ventricular fibrillation in patients with implantable cardioverter defibrillators: analysis of spontaneous ventricular tachycardia database.

Patients with heart disease and decreased heart rate variability (HRV) have an increased risk of all-cause mortality as well as arrhythmic death. The question of acute changes in HRV immediately preceding arrhythmic events remains unanswered. We analyzed data from patients with implantable cardioverter defibrillators who had ventricular tachycardia (VT) or ventricular fibrillation (VF) detected by the device. The device stores 1,000 consecutive RR intervals preceding the arrhythmic event detection and before device interrogation. Compared to this control segment, the mean heart rate (HR) increased prior to the arrhythmic event for both VT (88.5 vs 72.7 beats/min, P < 0.0005) and VF (85.4 vs 73.3 beats/min, P < 0.05) patients. No difference in HRV (as analyzed by a time-domain, frequency-domain [fast Fourier transform], and a nonlinear technique) has been detected. We estimated the amount of ectopic beats from the number of RR intervals that differed from the preceding RR interval by > 10%. The frequency of such beats was significantly higher in the prearrhythmic data segments than in the control segments for VT (10.7 vs 6.6/50 beats, P < 0.05) although not for VF (9.8 vs 6.1/50 beats, NS). We conclude that the HR and frequency of ectopic beats are higher prior to onset of the arrhythmic events, although HRV does not change markedly. These results are consistent with sympathetic activation being the predominant autonomic change prior to VT/VF onset in this patient population.

Adult

Sensitivity to orthostatic stress and beta-receptor activation in patients with isoproterenol-induced vasovagal syncope: a case controlled study.

Cardiomotor and vasomotor responses were assessed during isoproterenol tilt-induced vasovagal reaction in patients with a history of syncope. In a case controlled study, all patients and controls were subjected to a standard protocol: baseline supine (10 min), baseline tilt (70 degrees, 45 min), isoproterenol supine (0.05 microgram/kg per min, 10 min), and isoproterenol tilt (70 degrees, 10 min). The participants were 11 consecutive patients referred for syncope evaluation (5 men, 6 women; mean age, 34.1 +/- 10.4 years; range, 18-56 years) and 11 age and sex matched controls (5 men, 6 women; mean age, 35.5 +/- 12.2 years; range, 19-63 years). On-line, beat-to-beat measurements of cardiomotor functions (heart rate, stroke volume, and cardiac output) and vasomotor functions (systolic, mean, and diastolic blood pressures and total peripheral resistance [TPR]) were detected noninvasively by volume clamp photoplethysmography and impedance cardiography. Patients and controls had similar cardiomotor and vasomotor responses during passive tilt and during isoproterenol infusion in the supine position. Immediately after tilt during isoproterenol infusion and before the onset of symptoms, decreases in vasomotor functions were significant in study patients when compared with those in controls; whereas responses in cardiomotor functions were similar between the two groups. When compared with baseline supine findings, TPR decreased by 56.5% +/- 10.9% and 29.5% +/- 23.3% in the patient population and controls, respectively (P = 0.005). When compared with isoproterenol supine findings, TPR decreased by 27.5% +/- 22.8% in the study patients and increased by 22.6% +/- 48.1% in the controls (P = 0.005). The inability to overcome isoproterenol-induced vasodilation during orthostatic stress played an important role in the initiation of a vasovagal response. These observations hold the key to early detection of hemodynamic changes and potential therapeutic interventions before patients become symptomatic.

Adolescent

High failure rate for an epicardial implantable cardioverter-defibrillator lead: implications for long-term follow-up of patients with an implantable cardioverter-defibrillator.

OBJECTIVES: The purpose of this study was to determine the risk of epicardial lead failure during long-term follow-up and its mode of presentation. BACKGROUND: Despite the high prevalence of epicardial lead-based implantable cardioverter-defibrillators, their long-term performance is unknown, and appropriate follow-up has not been established. METHODS: The study group comprised all patients in whom an epicardial lead system was implanted at the Mayo Clinic between October 31, 1984 and November 3, 1994. The number of lead fractures and leads with fluid within the insulation and the mode of presentation were determined retrospectively by review of patient visits, radiographs of lead systems and data derived from formal lead testing. RESULTS: At 4 years, the survival rate free of lead malfunction, using formal lead testing, for 160 Medtronic epicardial patches (models 6897 and 6921) was 72% compared with 92.5% for the 179 Cardiac Pacemaker, Inc. (CPI) patches (models 0040 and 0041) (p = 0.01). In addition, five Medtronic patches in three patients had fluid within the lead insulation but no obvious fracture. No CPI patches had fluid identified within the leads. Of 330 Medtronic epicardial pace/sense leads (model 6917), the 4-year survival rate free of lead malfunction as assessed by lead testing was 96%. In all, 19 presentations of lead malfunction were found in 17 patients (2 patients had more than one lead fracture at different times). In 11 (58%) of these presentations, the patients were asymptomatic despite the presence of obvious lead fracture. CONCLUSIONS: Epicardial lead malfunction is common on long-term follow-up, and some leads have a failure rate of 28% at 4 years. Many patients with fractured leads remain asymptomatic, despite involvement of multiple leads in some cases. Therefore, consideration should be given to regular periodic lead testing in addition to routine X-ray examination, as asymptomatic lead malfunction can present with normal chest X-ray findings.

Aged

Agreement and coding reliability of the Minnesota and Mayo electrocardiographic coding systems.

PROBLEM: To determine whether diagnoses of myocardial infarction assigned by a system that uses Marquette 12SL electrocardiographic (ECG) codes with manual over-reading agree with diagnoses assigned by Minnesota ECG codes. STUDIES UNDERTAKEN: Agreement and recode reliability of Minnesota and Mayo coding systems based on 768 ECGs plus chest pain history and serum enzyme values were analyzed for a stratified random sample of 141 patients with an event in 1990 or 1991 coded as HICDA 410.x, 411, 413 or 796.9. The population was reconstructed from the stratified random sample so that population-based inferences could be made from the analysis. RESULTS: For the stratified random sample, exact agreement on 4 categories (evolving diagnostic, diagnostic, equivocal, or other ECG) between Mayo and Minnesota ECG coding was 53.9% (kappa = 0.37 +/- 0.05). Code-recode agreement was higher for Minnesota coding (83.0%; kappa = 0.74 +/- 0.05) compared with Mayo coding (73.8%; kappa = 0.64 +/- 0.05). The same pattern was present for the reconstructed population. For coding myocardial infarction based on the ECG, serum enzyme levels, and the presence or absence of ischemic chest pain, agreement between Mayo and Minnesota coding was 84.4% (kappa = 0.72 +/- 0.05) based on the stratified random sample and 81.7% (kappa = 0.67 +/- 0.06) based on the reconstructed population. For the stratified random sample, reliability of diagnosis of myocardial infarction was 93.6% (kappa = 0.88 +/- 0.04) for the Minnesota system and 94.3% (kappa = 0.90 +/- 0.03) for the Mayo system. CONCLUSION: ECG interpretation by the Mayo and Minnesota coding systems differs significantly, and Mayo ECG coding is less reliable than Minnesota ECG coding. Coding of myocardial infarction on the basis of ECGs, serum enzymes, and ischemic chest pain, however, is equally reliable for both systems.

Chest Pain

Importance of pacemaker noise reversion as a potential mechanism of pacemaker-ICD interactions.

Numerous types of interactions between pacemakers and implantable cardioverter defibrillators (ICDs) have been described. Pacemaker outputs preventing appropriate detection of ventricular tachycardia or ventricular fibrillation by the ICD is one of the more serious. Asynchronous pacemaker activity during ventricular arrhythmias may be caused by either nonsensing of the arrhythmia or by noise reversion, which is an algorithm that causes the pacemaker to switch to asynchronous pacing when repetitive sensing at a high rate occurs. We analyzed the mechanisms underlying asynchronous pacemaker activity in ventricular arrhythmias using pacemaker telemetry during the arrhythmia. Thirty-nine induced arrhythmias from 26 different procedures in 19 patients with both pacemakers and ICDs were analyzed. Of the 39 arrhythmias, asynchronous pacemaker activity occurred in 16. The underlying mechanism was nonsensing in 4 episodes and noise reversion in 12 episodes. Clinically significant interference with detection arose on three occasions. Conditions favoring the occurrence of noise reversion include specific pacemaker models, arrhythmia cycle lengths in the range causing noise reversion of the individual pacemaker model, long noise sampling periods, and VVI pacing mode. Noise reversion can be diagnosed by telemetering the pacemaker marker channel during ventricular arrhythmias as a part of routine pacemaker-ICD interaction evaluation. It can be prevented or minimized by programming short ventricular refractory periods or using pacemakers with short retriggerable refractory periods.

Bradycardia

Randomized prospective pilot study of long-term dual-site atrial pacing for prevention of atrial fibrillation.

OBJECTIVE: To determine whether dual-site atrial pacing is feasible, safe, and effective. DESIGN: We undertook a randomized prospective single-blind crossover study. MATERIAL AND METHODS: Nine patients with at least two episodes per month of symptomatic paroxysmal atrial fibrillation participated in a randomized crossover study involving three separate 3-month blocks of single-site atrial pacing, dual-site atrial pacing, and control (support-only) pacing. RESULTS: Dual-site atrial pacing resulted in shorter P wave duration (81 +/- 14 ms) than did single-site pacing (111 +/- 12 ms) or control sinus rhythm (123 +/- 9 ms) (P<0.0001) and in fewer premature atrial complexes on Holter monitoring (P = 0.06). The arrhythmia-free interval was longer with dual-site pacing (67 +/- 17 days) than with single-site (62 +/- 30 days) or support-only (49 +/- 34 days) pacing (P = 0.10). This pilot study was not statistically powered to detect a difference between pacing modes. CONCLUSION: (1) Dual-site atrial pacing is feasible and safe; (2) it shortens the P wave duration and tends to decrease premature atrial complexes on Holter monitoring; (3) any atrial pacing tends to prolong the arrhythmia-free interval; and (4) this pilot study enrolled too few patients to determine whether a significant difference in pacing modes exists and supports the need for a larger study.

Adult

Indications, effectiveness, and long-term dependency in permanent pacing after cardiac surgery.

The purposes of this study were to define predictors of long-term pacemaker dependency in patients having permanent pacemakers implanted shortly after cardiac surgery, and to evaluate short- and long-term results and survival in this population. Data from 120 adult patients with implantation since 1980 were retrospectively analyzed. Acute and chronic complication rates (4.2% and 16.6%, respectively) were not higher than those expected in the general paced population. In addition, continuous rhythm was evaluated by use of pacemaker inhibition in a subgroup of 20 patients to verify the validity of clinical criteria for pacemaker dependency. Of the patients evaluated for dependency, 41% eventually became nondependent. Prolonged monitoring with an inhibited pacemaker confirmed the accuracy of our method of clinical evaluation of pacemaker dependency. Significant predictors of long-term pacemaker dependency were complete atrioventricular block as the indication and bypass time of > 120 minutes (by multivariate and univariate analyses, respectively). Postoperative complete atrioventricular block is the most important predictor of pacemaker dependency, enabling an earlier decision on permanent pacemaker implantation (no later than the sixth and the ninth postoperative days for wide-complex and narrow-complex escape, respectively). Further prospective studies are needed to define optimal implantation times for indications other than complete atrioventricular block.

Adult