Search PubMedSearch

Biomedical subjects

S C Body

Publications and source records attributed to S C Body.

At least 19 recordsLinked to original sources

Individualized feedback of volatile agent use reduces fresh gas flow rate, but fails to favorably affect agent choice.

BACKGROUND: Cost reduction has become an important fiscal aim of many hospitals and anesthetic departments, despite its inherent limitations. Volatile anesthetic agents are some of the few drugs that are amenable to such treatment because fresh gas flow rate (FGFR) can be independent of patient volatile anesthetic agent requirement. METHODS: FGFR and drug use were recorded at the temporal midpoint of 2,031 general anesthetics during a 2-month preintervention period. Staff and residents were provided with their preintervention individual mean FGFR, their peer group mean, and educational material regarding volatile agent costs and low-flow anesthesia. FGFR and drug use were remeasured over a 2-month period (postintervention) immediately after this information (N = 2,242) and again 5 months later (delayed follow-up), for a further 2-month period (N = 2,056). RESULTS: For all cases, FGFR decreased from 2.4+/-1.1 to 1.8+/-1.0 l/min (26% reduction) after the intervention and increased to 1.9+/-1.1 l/min (5% increase of preintervention FGFR) at the time of delayed follow-up. Use of more expensive volatile agents (desflurane and sevoflurane) increased during the study period (P < 0.01). In a subgroup of 44 staff members with more than five cases in all study periods, 42 members decreased their mean FGFR after intervention. At delayed follow-up, 30 members had increased their FGFR above postintervention FGFR but below their initial FGFR. After accounting for other predictors of FGFR, the effectiveness of the intervention was significantly reduced at follow-up (28% reduction), but retained a significant effect compared to preintervention FGFR (19% reduction). CONCLUSIONS: Although individual feedback and education regarding volatile agent use was effective at reducing FGFR, effectiveness was reduced without continued feedback. Use of more expensive volatile agents was not reduced by education regarding drug cost, and actually increased.

Anesthesia, Inhalation

Relation between preoperative inspiratory lung resistance and the outcome of lung-volume-reduction surgery for emphysema.

BACKGROUND: Surgery to reduce lung volume has recently been reintroduced to alleviate dyspnea and improve exercise tolerance in selected patients with emphysema. A reliable means of identifying patients who are likely to benefit from this surgery is needed. METHODS: We measured lung resistance during inspiration, static recoil pressure at total lung capacity, static lung compliance, expiratory flow rates, and lung volumes in 29 patients with chronic obstructive lung disease before lung-volume-reduction surgery. The changes in the forced expiratory volume in one second (FEV1) six months after surgery were related to the preoperatively determined physiologic measures. A response to surgery was defined as an increase in the FEV1 of at least 0.2 liter and of at least 12 percent above base-line values. RESULTS: Of the 29 patients, 23 had some improvement in FEV1 including 15 who met the criteria for a response to surgery. Among the variables considered, only preoperative lung resistance during inspiration predicted changes in expiratory flow rates after surgery. Inspiratory lung resistance correlated significantly and inversely with improvement in FEV1 after surgery (r=-0.63, P<0.001). A preoperative criterion of an inspiratory resistance of 10 cm of water per liter per second had a sensitivity of 88 percent (14 of 16 patients) and a specificity of 92 percent (12 of 13 patients) in identifying patients who were likely to have a response to surgery. CONCLUSIONS: Preoperative lung resistance during inspiration appears to be a useful measure for selecting patients with emphysema for lung-volume-reduction surgery.

Adult

Hematocrit value on intensive care unit entry influences the frequency of Q-wave myocardial infarction after coronary artery bypass grafting. The Institutions of the Multicenter Study of Perioperative Ischemia (McSPI) Research Group.

OBJECTIVES: No data exist regarding "the best" hematocrit value after coronary artery bypass graft surgery. Transfusion practice varies, because neither an optimal hematocrit value nor a uniform transfusion trigger criterion has been determined. METHODS: To investigate the optimal hematocrit value, we studied 2202 patients undergoing coronary bypass. The hematocrit value on entry into the intensive care unit (IHCT) was categorized into three groups: high (> or = 34%), medium (25% to 33%), and low (< or = 24%). Characteristics and adverse events (outcomes) were compared, and the effect of IHCT on the risk of myocardial infarction was determined by logistic regression. RESULTS: High IHCT (> or = 34%) was associated with an increased rate of myocardial infarction (8.3% vs 5.5% vs 3.6%; p < or = 0.03, high, medium vs low) and with more severe left ventricular dysfunction (11.7% vs 7.4% and 5.7%; p=0.006, high, medium vs low). Mortality rate increased with higher IHCT when all the high-risk subgroups were combined (8.6% vs 4.5% vs 3.2%; p < 0.001, high, medium vs low). By multivariate analysis, IHCT remained the most significant predictor of adverse outcomes (relative risk high vs low 2.22, 95% confidence interval: 1.04 to 4.76). No characteristic, event, medication, or transfusion therapy confounded the relationship between IHCT and outcome. CONCLUSION: High IHCT is associated with a higher rate of myocardial infarction and is an independent predictor of infarction. On the basis of the risk of myocardial infarction, there is no rationale for transfusion to an arbitrary level after coronary artery bypass grafting.

Anemia

Variability in transfusion practice for coronary artery bypass surgery persists despite national consensus guidelines: a 24-institution study. Institutions of the Multicenter Study of Perioperative Ischemia Research Group.

BACKGROUND: An estimated 20% of allogeneic blood transfusions in the United States are associated with cardiac surgery. National consensus guidelines for allogeneic transfusion associated with coronary artery bypass graft (CABG) surgery have existed since the mid- to late 1980s. The appropriateness and uniformity of institutional transfusion practice was questioned in 1991. An assessment of current transfusion practice patterns was warranted. METHODS: The Multicenter Study of Perioperative Ischemia database consists of comprehensive information on the course of surgery in 2,417 randomly selected patients undergoing CABG surgery at 24 institutions. A subset of 713 patients expected to be at low risk for transfusion was examined. Allogeneic transfusion was evaluated across institutions. Institution as an independent risk factor for allogeneic transfusion was determined in a multivariable model. RESULTS: Significant variability in institutional transfusion practice was observed for allogeneic packed red blood cells (PRBCs) (27-92% of patients transfused) and hemostatic blood components (platelets, 0-36%; fresh frozen plasma, 0-36%; cryoprecipitate, 0-17% of patients transfused). For patients at institutions with liberal rather than conservative transfusion practice, the odds ratio for transfusion of PRBCs was 6.5 (95% confidence interval [CI], 3.8-10.8) and for hemostatic blood components it was 2 (95% CI, 1.2-3.4). Institution was an independent determinant of transfusion risk associated with CABG surgery. CONCLUSIONS: Institutions continue to vary significantly in their transfusion practices for CABG surgery. A more rational and conservative approach to transfusion practice at the institutional level is warranted.

Blood Component Transfusion

The concordance of intraoperative left ventricular wall-motion abnormalities and electrocardiographic S-T segment changes: association with outcome after coronary revascularization. Multicenter Study of Perioperative Ischemia (McSPI) Research Group.

BACKGROUND: Transesophageal echocardiography (TEE) and Holter electrocardiography (ECG) are used to detect intraoperative ischemia during coronary artery bypass graft surgery (CABG). Concordance of these modalities and sensitivity as indicators of adverse perioperative cardiac outcomes are poorly defined. The authors tried to determine whether routine use of Holter ECG and TEE in patients with CABGs has clinical value in identifying those patients in whom myocardial infarction (MI) is likely to develop. METHODS: A total of 351 patients with CABG and both ECG- and TEE-evaluable data were examined for the occurrence of ischemia and infarction. The TEE and five-lead Holter ECGs were performed continuously during cardiac surgery. The incidence of MI (creatine kinase-MB > or = 100 ng/ml) within 12 h of arrival in the intensive care [ICU] unit, new ECG Q wave on ICU admission or on the morning of postoperative day 1, or both, were recorded. RESULTS: Electrocardiographic or TEE evidence of intraoperative ischemia was present in 126 (36%) patients. The concordance between modalities was poor (positive concordance = 17%; Kappa statistic = 0.13). Myocardial infarction occurred in 62 (17%) patients, and 32 (52%) of them had previous intraoperative ischemia. Of these, 28 (88%) were identified by TEE, whereas 13 (41%) were identified by ECG. Prediction of MI was greater for TEE compared with ECG. CONCLUSIONS: Wall-motion abnormalities detected by TEE are more common than S-T segment changes detected by ECG, and concordance between the two modalities is low. One half of patients with MI had preceding ECG or TEE ischemia. Logistic regression revealed that TEE is twice as predictive as ECG in identifying patients who have MI.

Aged

Influence of inhaled nitric oxide on systemic flow and ventricular filling pressure in patients receiving mechanical circulatory assistance.

BACKGROUND: In patients with left ventricular (LV) dysfunction, inhaled nitric oxide (NO) decreases pulmonary vascular resistance (PVR) but causes a potentially clinically significant increase in left atrial pressure (LAP). This has led to the suggestion that inhaled NO may reach the coronary circulation and have a negative inotropic effect. This study tested an alternative hypothesis that LAP increases because of volume shifts to the pulmonary venous compartment caused by NO-induced selective pulmonary vasodilation. METHODS AND RESULTS: The Thermo Cardiosystems Heartmate is an LV assist device (LVAD) that can be set (by controlling pump rate) to deliver fixed or variable systemic blood flow. Eight patients (between 1 and 11 days after LVAD implantation) were administered inhaled NO (20 and 40 ppm for 10 minutes), and LAP, systemic flow, and pulmonary arterial pressure were measured in both fixed and variable pump flow modes. In both modes, inhaled NO lowered PVR (by 25 +/- 6% in the fixed mode, P < .001, and by 21 +/- 5% in the variable mode, P < .003). With fixed pump flow, LAP rose from 12.5 +/- 1.2 to 15.1 +/- 1.4 mm Hg (P < .008). In the variable flow mode, LAP did not increase and the assist device output rose from 5.3 +/- 0.3 to 5.7 +/- 0.3 L/min (P < .008). CONCLUSIONS: A selective reduction in PVR by inhaled NO can increase LAP if systemic flow cannot increase. These data support the hypothesis that with LV failure, inhaled NO increases LAP by increasing pulmonary venous volume and demonstrate that inhaled NO has beneficial hemodynamic effects in LVAD patients.

Administration, Inhalation

Manufacture and measurement of nitrogen oxides.

A decade of research has identified nitric oxide as a unique endogenous biologic mediator with functions as diverse as vasodilation, macrophage cytotoxicity, platelet adhesion, and memory formation. Measurement devices, previously used in research on atmospheric nitrogen oxides, are being adapted for and applied to clinical situations without approval, regulation, or rigorous testing, and with little understanding of how the devices work or their limitations. This article discusses the chemistry, manufacture, and measurement of nitrogen oxides.

Administration, Inhalation

Laryngeal mask airway for therapeutic fiberoptic bronchoscopic procedures.

These cases illustrate the advantages of the laryngeal mask as compared with an endotracheal tube or oxygen face mask for selected patients undergoing therapeutic bronchoscopic procedures. The advantages include a larger internal diameter allowing easier passage of instruments, reduced work of breathing, lack of discomfort associated with insertion, access to the vocal cords and upper trachea unimpeded by the presence of an endotracheal tube, and capnographic and volume monitoring of respiration. The LMA is thus a valuable alternative for airway management in pulmonary compromised patients undergoing therapeutic bronchoscopic procedures.

Adult

Pulmonary function changes during epidural anesthesia for cesarean delivery.

Although changes in pulmonary function in parturients are documented, little is known about effects of regional anesthesia on these changes. This study was undertaken to determine if two local anesthetics, often used for epidural anesthesia for cesarean delivery, have different effects on pulmonary function testing. Nineteen ASA physical status I parturients undergoing elective cesarean delivery with epidural anesthesia were randomly assigned in double-blind fashion to receive either 0.5% bupivacaine or 2% lidocaine with epinephrine (1/200,000). Pulmonary function tests were measured using a calibrated spirometer with computer-recorded flow volume loops. Peak inspiratory pressure and peak inspiratory flow rate, peak expiratory pressure (PEP) and peak expiratory flow rate, forced vital capacity (FVC), and forced expiratory volume in 1 s (FEV1) were measured. Measurements were taken prior to epidural placement and at T-10 and T-4 levels. Peak inspiratory pressure, FEV1/FVC, FEV1, FVC, peak expiratory flow rate, and peak inspiratory flow rate did not differ from baseline in either group. Patients receiving lidocaine showed a significantly greater decrease in PEP at both T-10 and T-4 levels. Pep is largely dependent on abdominal musculature. If a denser motor block is provided by 2% lidocaine with epinephrine than by 0.5% bupivacaine, these muscles would be more affected, resulting in a greater decrease in PEP. These results may have implications regarding choice of local anesthetic for epidural anesthesia in parturients with some degree of respiratory compromise undergoing cesarean delivery.

Adult

Multicenter study of target-controlled infusion of propofol-sufentanil or sufentanil-midazolam for coronary artery bypass graft surgery. Multicenter Study of Perioperative Ischemia (McSPI) Research Group.

BACKGROUND: The use of target-controlled infusions of anesthetics for coronary artery bypass graft surgery has not been studied in detail. The effects of target-controlled infusions of propofol or sufentanil, supplemented by infusions of sufentanil or midazolam, respectively, were evaluated and compared. METHODS: At 14 clinical sites, 329 patients were given a target-controlled infusion of propofol (n = 165) to produce effect-site concentration (Ce) of > or = 3-micrograms/ml or a target-controlled infusion of sufentanil (n = 164). Sufentanil or midazolam, respectively, also were infused. Systolic hypertension, hypotension, tachycardia, and bradycardia were assessed by measuring heart rate and blood pressure every minute during operation. Myocardial ischemia was assessed perioperatively by monitoring ST segment deviation via continuous three-lead Holter electrocardiography, and it was evaluated during operation by monitoring left ventricular wall motion abnormality via transesophageal echocardiography. RESULTS: The measured cardiovascular parameters were satisfactory and usually similar for the patients receiving propofol-sufentanil or sufentanil-midazolam. The primary endpoint of the percentage of patients with intraoperative ST segment deviation (23 +/- 6% vs. 24 +/- 6%, P = 0.86) did not differ significantly between the two groups. The incidence of left ventricular wall motion abnormality shown on transesophageal echocardiography before (19 +/- 4% vs. 26 +/- 4%, P = 0.25) and after (23 +/- 4% vs. 31 +/- 5%, P = 0.32) cardiopulmonary bypass also did not differ significantly for the two groups. Changes in intraoperative target concentration were more frequent with propofol-sufentanil anesthetic than with sufentanil-midazolam (11.7 +/- 7.1 vs. 7.3 +/- 3.6, P < 0.001). The incidence of intraoperative hypotension (77% vs. 55%, P < 0.001), the use of inotropic/vasopressor medications (93% vs. 84%, P = 0.01), and the administration of crystalloids (2.8 +/- 1.4 L vs. 2.4 +/- 1.2 L, P < 0.001) were significantly greater in the propofol-sufentanil group. Conversely, the incidence of intraoperative hypertension (43% vs. 54%, P = 0.05) and the use of antihypertensive/vasodilator medications (70% vs. 90%, P < 0.001) were significantly less in the propofol-sufentanil group. CONCLUSIONS: Target-controlled infusions of propofol or sufentanil, supplemented by infusions of sufentanil or midazolam, respectively, were suitable to provide anesthesia for coronary artery bypass graft surgery. Continuous monitoring revealed a high prevalence of hemodynamic abnormalities. Despite greater hypotension in the propofol-sufentanil group and greater hypertension in the sufentanil-midazolam group, episodes of myocardial ischemia were similar for both groups and were not temporally related to episodes of hemodynamic abnormalities.

Aged

Sevoflurane depresses myocardial contractility less than halothane during induction of anesthesia in children.

BACKGROUND: Cardiovascular stability is an important prerequisite for any new volatile anesthetic. We compared echocardiographically derived indices of myocardial contractility during inhalation induction with sevoflurane and halothane in children. METHODS: Twenty children were randomized to receive either halothane or sevoflurane for inhalation induction of anesthesia. No preoperative medications were given. Myocardial contractility was evaluated at baseline and at sevoflurane and halothane end-tidal concentrations of 1.0 minimum alveolar concentration (MAC) and 1.5 MAC. RESULTS: There were no differences between groups in patient age, sex, physical status, weight, or height. Equilibration times and MAC multiples of sevoflurane and halothane were comparable. Vital signs remained stable throughout the study. Left ventricular end-systolic meridional wall stress increased with halothane but remained unchanged with sevoflurane. Systemic vascular resistance decreased from baseline to 1 MAC and 1.5 MAC with sevoflurane. Halothane depressed contractility as assessed by the stress-velocity index and stress-shortening index, whereas contractility remained within normal limits with sevoflurane. Total minute stress and normalized total mechanical energy expenditure, measures of myocardial oxygen consumption, did not change with either agent. CONCLUSIONS: Myocardial contractility was decreased less during inhalation induction of anesthesia with sevoflurane compared with halothane in children. Although the induction of anesthesia with sevoflurane or halothane was equally well tolerated, the preservation of myocardial contractility with sevoflurane makes it an attractive alternative for inducing anesthesia in children.

Anesthesia, Inhalation

Platelet activation and interactions with the microvasculature.

Platelet adherence to structurally or functionally damaged endothelium and its subsequent activation are multifaceted events. Regulation of the rate and extent of platelet adhesion is under local control by the platelets and endothelium. Even in the absence of platelet adhesion to endothelium or subendothelium, there is a complex hemostatic balance of coagulation and anticoagulation. This is mediated by the manufacture, release, and inactivation of various procoagulant and anticoagulant compounds, predominantly by the platelets and endothelium. The relationship between the two in maintaining the homeostasis of coagulation and other processes is complex. This review focuses on the structure, function, and interaction of endothelium, subendothelium, and platelets and on their vasoactive and pro-/anticoagulant functions.

Animals

Shed whole blood autotransfusion during aortic aneurysm operation with a modified collection infusion system.

We describe a modified shed whole blood collection and autotransfusion system that allows several options for the processing and autotransfusion of shed blood: use of the Cell Saver (Haemonetics, Braintree, MA) or the ultrafiltration of collected blood, and the autotransfusion of unprocessed shed whole blood. The system has proved useful for transfusion in the setting of thoracic aortic operations, and we describe here our experience in 5 patients undergoing resection of a descending thoracic aortic aneurysm in whom this system was used.

Aged

Nitric oxide: delivery, measurement, and clinical application.

The biologic and therapeutic roles of NO are rapidly being elucidated. Before inhalational NO administration is commonplace, there is a clear need for consensus regarding safe and accurate delivery and measurement systems. The potential for NO usage appears large and potentially life-saving; yet multicenter trials need to carefully evaluate efficacy and safety.

Humans

Management of a term parturient with tracheal stenosis.

We describe the management of a 37-week parturient with a breech singleton pregnancy presenting with progressive dyspnoea caused by tracheal stenosis. The patient underwent bronchoscopy using a flexible fibreoptic bronchoscope and dilatation of a stenosis using a balloon-tipped catheter. Subsequently, the patient had a normal delivery.

Adult

Gestational exposure to phencyclidine (PCP) in rats decreases PCP binding sites in term fetal brain.

Pregnant Sprague-Dawley rats were treated with 5 mg/kg body weight of phencyclidine (PCP) injected at 1 ml/kg subcutaneously on three consecutive days at four different stages of gestation. Within 10-30 min after treatment, dams showed some lack of motor coordination and became lethargic. On gestational day 21, all rats were killed by decapitation and brains were dissected and stored from mother and fetus for neurochemical analysis. PCP, dopamine and muscarinic cholinergic receptor binding was measured in membranes prepared from maternal and fetal whole brain. Neurotransmitter concentrations were also measured in the fetal brain homogenates. There was a significant decrease in PCP binding sites in fetal but not maternal brains after maternal PCP injection at gestational days 12-14, 15-17 and 18-20, but not at 9-11 days. Dopamine and muscarinic cholinergic receptor binding was not significantly altered in fetal or maternal brain when compared with vehicle control animals. The whole brain dopamine, 3,4-dihydroxyphenylacetic acid, serotonin, and 5-hydroxyindoleacetic acid concentrations did not show significant change in any group studied. These data indicate that gestational exposure to PCP decreases high affinity binding of PCP in term fetal brain at doses which do not alter maternal PCP receptor binding.

Animals