Search PubMed⌕ Search

Biomedical subjects

S Birkeland

Publications and source records attributed to S Birkeland.

At least 19 recordsLinked to original sources

Effect of protective solutes on leakage from and survival of immobilized lactobacillus subjected to drying, storage and rehydration

When lactic acid bacteria are used industrially as fermentation starters it is important to obtain stable and highly viable bacterial cultures. Six strains of Lactobacillus encapsulated in Ca-alginate gel beads were investigated to determine whether dehydration, storage and rehydration may inflict injury. A negative relationship between leakage of lactate dehydrogenase and survival rates was found. Mesophilic lactobacilli showed only negligible leakage compared with thermophilic strains when dehydrated at 30 degrees C to a level of 0.11 g H20 (g dry wt)-1. The choice of an appropriate suspending medium to be introduced before drying was therefore very important for thermophilic lactobacilli in order to increase the survival rates during dehydration, storage and rehydration. The osmoregulatory solutes tested were adonitol, betaine, glycerol and reconstituted non-fat milk solids (NFMS). Less injury was inflected during dehydration for Lactobacillus helveticus with adonitol, glycerol and NFMS. Survival rates for the strains subjected to immobilization, dehydration, storage and rehydration varied with the strain and the protective solute when fluidized-bed drying was used at 5 degrees C to a level as high as 0.34 g H20 (g dry wt)-1. Non-fat milk solids gave the best protection for thermophilic lactobacilli, while adonitol and NFMS were best for mesophilic lactobacilli.

Journal Article↗

Midazolam-fentanyl-isoflurane anaesthesia is suitable for haemodynamic and fluid balance studies in pigs.

The domestic pig is a useful model in certain areas of biomedical research. Effective use of this species is often encumbered by lack of reference values in conscious as well as anaesthetized animals. Anaesthesia itself influences physiological and biological variables; the anaesthetic technique often affects experimental results. The relationship between anaesthesia and haemodynamics is well characterized in man, but less established in pigs. We studied the effect of midazolam-fentanyl-isoflurane anaesthesia in six immature, male, domestic pigs (Norwegian landrace). Haemodynamic variables (heart rate, arterial systolic, mean, diastolic pressures, pulmonary systolic, mean, diastolic pressures, pulmonary capillary wedge pressure), tissue perfusion, lymph flow (thoracic duct) were recorded for 3 h in animals with open chest through midline sternotomy. Variables relevant to fluid balance, e.g. interstitial hydrostatic pressure (Pi), serum-colloid osmotic pressure (s-COP) and serum-albumin (s-albumin) and -protein (s-protein) concentrations were measured. With the chosen anaesthetic technique haemodynamic variables, including lymph flow, and laboratory variables remained constant during the study period. Most variables were similar to conditions in humans. In contrast to adult humans exposed to the same anaesthetic technique, these pigs had lower haemoglobin-, s-albumin- and s-protein concentrations. A finding which may reflect immaturity. Liver and lung perfusion decreased significantly during the study period whereas perfusion of the other organs studied remained constant. Lack of responses to defined noxious stimuli during the study period suggest adequate analgesia. We conclude that midazolam, fentanyl and isoflurane provide cardiovascular stability including normal microvascular fluid exchange, which are essential elements for securing the quality of results obtained during cardiovascular research in anaesthetized pigs.

Anesthesia↗

Effects of velocity distribution, diameter measurement and velocity tracing on the accuracy of cardiac output measurement by pulsed Doppler echocardiography in the aortic annulus of pigs.

UNLABELLED: The accuracy of cardiac output measurement by pulsed Doppler echocardiography can be affected by several factors, such as the velocity distribution, the measurement of diameter and the method of tracing the pulsed Doppler flow spectrum. This experimental study was designed to find the most accurate way of measuring cardiac output in consideration of all these factors. In 10 open-chest normal piglets (24 +/- 1 kg), the velocity distribution in the aortic annulus was evaluated using Doppler colour flow mapping. Cardiac output was measured by pulsed Doppler echocardiography in the aortic annulus by a number of different ways and compared to the simultaneous result of the thermodilution method. All measurements were made at baseline, after intravenous injection of esmolol and during infusion of dobutamine. RESULTS: (1) the velocity distribution in the aortic annulus in the piglets was just slightly skewed during all three haemodynamic situations; (2) The in vivo measurements of the diameter of the aortic annulus varied throughout the ejection period, but the average of the three largest diameter measurements was almost identical with the diameter measured in vitro (18.5 +/- 0.3 mm vs. 18.6 +/- 0.2 mm; p = NS); (3) Tracing the maximal velocity of the pulsed Doppler flow spectrum produced a cardiac output that was 18%-21% higher than that measured by the thermodilution method, while tracing the brightest part (modal velocity) of the pulsed Doppler flow spectrum yielded a cardiac output very close to the thermodilution measurement. CONCLUSION: The velocity distribution in the aortic annulus in the piglet has little effect on cardiac output measurement by pulsed Doppler. Using the maximal measurable diameter of the aortic annulus and tracing the brightest part of the pulsed Doppler flow spectrum yielded the cardiac output closest to that measured by the thermodilution method.

Adrenergic beta-Antagonists↗

High afterload during 10 min of regional ischaemia affects diastolic creep but not systolic function in reperfused (stunned) myocardium.

The effect of afterload during regional ischaemia on myocardial stunning was studied in 15 pentobarbital anaesthetized cats. 10 min occlusion of the left anterior descending artery (LAD) was followed by 60 min of reperfusion. Afterload was decreased by intravenous infusion of nitroglycerine 3-8 micrograms kg-1 min-1 in group I (n = 8); left ventricular peak systolic pressure (LVSP) 84 +/- 4 mmHg (mean +/- SEM) during coronary artery occlusion. In group II (n = 7) LVSP was increased to 188 +/- 10 mmHg by inflating an intraaortic balloon during coronary artery occlusion. Regional function in the LAD perfused region was evaluated by cross-oriented sonomicrometry. Myocardial tissue blood flow was evaluated by radio-labelled microspheres. Afterload alterations did not affect regional systolic shortening (10.8 +/- 2.0% vs. 11.0 +/- 1.5% in group I and II, respectively, after 60 min of reperfusion). However, increased end-diastolic dimensions (diastolic creep) in both the circumferential and longitudinal segments were markedly more pronounced in the high afterload group (group II). Also important, the markedly increased myocardial tissue blood flow during reperfusion in group II as compared with group I (2.30 +/- 0.18 vs. 1.34 +/- 0.08 mL min-1 g-1 and 2.58 +/- 0.23 vs. 1.49 +/- 0.07 mL min-1 g-1 in subepicardial and subendocardial layers in the LAD perfused region) suggests that increased diastolic creep increased metabolic demands. This study indicates that passive stretching of the ischaemic area during coronary artery occlusion is an important mechanism behind diastolic creep.

Animals↗

Endogenous adenosine attenuates myocardial stunning by antiadrenergic effects exerted during ischemia and not during reperfusion.

The effect of adenosine receptor blockade and adrenergic blockade on myocardial stunning [left anterior descending coronary artery (LAD) occluded for 10 min and reperfused for 180 min] was studied in 38 open-chest cats. A control group (Control) was compared with two other groups in which adenosine receptors were blocked by 8-phenyltheophylline (7.5 mg/kg) before reperfusion (8-PT-R) or before ischemia (8-PT-I). Group A, in which adrenergic receptors were blocked (doxazosin 200 micrograms/kg + propranolol 1 mg/kg), was compared with group A + 8-PT-I, in which both adenosine and adrenergic receptors were blocked before coronary artery occlusion. Regional systolic function assessed by sonomicrometry in the LAD perfused area recovered less in 8-PT-I (55 +/- 5% recovery) as compared with Control (87 +/- 9%) and 8-PT-R (89 +/- 8%), which indicates that adenosine receptor blockade during ischemia increases stunning. Functional recovery was similar in Control, group A (96 +/- 5%), and group A + 8-PT-I (87 +/- 5%), which demonstrates that if adrenergic receptors are blocked, adenosine receptor blockade during ischemia does not increase stunning. These results may indicate that the cardioprotective effects of endogenous adenosine are mediated through antiadrenergic effects exerted during coronary artery occlusion.

Adenosine↗

The velocity distribution in the aortic annulus at different times during systole is mainly determined by the pattern of flow convergence in the left ventricular outflow tract--an experimental study using Doppler colour flow mapping.

An experimental study in 10 open chest normal pigs (body weight: 24 +/- 1 kg) was carried out to explore the relationship between the velocity distribution in the aortic annulus and the pattern of flow convergence in the left ventricular outflow tract. The cross-sectional velocity profiles in the aortic annulus were constructed by using Doppler colour flow mapping with a previously validated time-interpolation method. The pattern of flow convergence in the left ventricular outflow tract was quantified by measuring the colour flow areas on the anterior and posterior sides of the central axis of the aortic annulus, and calculating their difference. The dynamic changes of the velocity distribution, the pattern of flow convergence and the septal angle throughout systole were observed. The velocity distribution in the aortic annulus changed according to the pattern of flow convergence in the left ventricular outflow tract. During early systole, the pattern of flow convergence was most asymmetrical. With the central longitudinal axis of the aortic annulus as a reference, the main part of the converging flow was along the anterior wall of the left ventricular outflow tract. Consequently, the velocity profile in the aortic annulus was most skewed during the early systole, with the highest velocity along the anterior wall. Towards late systole, the pattern of flow convergence became more and more symmetrical, and the velocity distribution in the aortic annulus gradually became flat. A significant correlation was found between the extent of asymmetry of the pattern of flow convergence in the left ventricular outflow tract and the extent of skewness of the velocity distribution in the aortic annulus (r = 0.69, P < 0.001). Throughout systole, septal angle increased very slightly (from 35 +/- 3 to 38 +/- 3 degrees, P < 0.01). The pattern of flow convergence in the left ventricular outflow tract is a major determinant of the velocity distribution in the aortic annulus in pigs.

Animals↗

Comparison of transit-time and Doppler ultrasound methods for measurement of flow in aortocoronary bypass grafts during cardiac surgery.

To evaluate the accuracy of flow measurements in aortocoronary bypass grafts with the ultrasound transit-time method, an in vitro and in vivo comparison was carried out. The in vitro comparison with evaluation against both true flow and the ultrasound Doppler method, was carried out with a fresh saphenous vein mounted in a pulsatile flow rig. The two flow probes were placed on the graft 4-5 cm apart to avoid acoustic interference, and blood was pumped through the system at different flow rates. The comparison between the methods showed excellent agreement with a linear correlation coefficient of 0.996, and a mean error of -2.9 ml/min with limits of agreement +/- 13.1 ml/min (+/- 2 SD = 95% of measured differences between these limits). However, against true flow, both methods overestimated flow slightly with mean error 4.4 and 7.3 ml/min for the transit-time and Doppler, respectively. Both methods showed excellent correlation with true flow (correlation coefficient 0.998 for the transit-time and 0.997 for the Doppler method). The in vivo accuracy was evaluated by comparison of the two methods in 9 patients. The two probes were placed on the same saphenous vein grafts 4-5 cm apart, and a total of 34 measurements in 17 grafts were carried out including measurements at baseline and after papaverine injection. The correlation coefficient was 0.990 and linear regression analysis gave the equation: Transit-time flow = 1.00 x Doppler flow + 1.3. In terms of flow, the mean error was 1.5 ml with limits of agreement +/- 17.2 ml.(ABSTRACT TRUNCATED AT 250 WORDS)

Blood Flow Velocity↗

Blockade of adenosine receptors during ischaemia increases systolic dysfunction but does not affect diastolic creep in stunned myocardium.

The impact of adenosine receptor blockade on left ventricular systolic function and diastolic creep in stunned myocardium was studied in 20 sodium pentobarbital anaesthetized cats. A control group (n = 10) was compared with a group (n = 10) where adenosine receptors were blocked by 8-phenyltheophylline (7.5 mg.kg-1 i.v.) prior to a 10 min occlusion of the left anterior descending coronary artery. Regional function was assessed by sonomicrometry of the left ventricular anterior wall. Tissue blood flow and haemodynamic measurements were obtained at pre-occlusion, during occlusion, and after 30 and 60 min of reperfusion. Tissue blood flow in the LAD region was low and homogeneous during coronary occlusion in both groups. Systolic function assessed by regional shortening and inotropic parameters was significantly more reduced in the 8-PT treated group (P < 0.05). Diastolic creep and compliance assessed by the end-diastolic pressure-length relationship did not differ between groups. Thus, endogenous adenosine protects against systolic dysfunction, but appears to have no impact on diastolic creep in stunned myocardium. Furthermore, our results show that the protective effect of endogenous adenosine is not caused by increased collateral blood flow into the ischaemic area during coronary artery occlusion or by increased blood flow in the reperfusion period.

Adenosine↗

Myocardial contraction patterns in non-ischaemic and ischaemic regions during acute coronary insufficiency.

The effect of coronary insufficiency on the myocardial contraction pattern was studied in 11 thoracotomized cats using apical long axis echocardiograms and cross-oriented segments in the anterior midwall. Myocardial tissue blood flow was studied using radiolabelled microspheres. After circumflex coronary artery occlusion, ejection shortening increased on average 17% for circumferential segments (P < 0.05) and 61% for longitudinal segments (P < 0.001). Hyperkinesis was also validated as augmented anterior endocardial wall motion and wall thickening. Circumflex occlusion increased end-systolic sphericity of the left ventricle (P < 0.05). Subsequent underperfusion of the left coronary artery, in two discrete steps, decreased subendocardial blood flow by, on average, 36% (P < 0.001) and 75% (P < 0.001) vs the post-occlusion value, while subepicardial flow did not change. While subendocardial blood flow decreased by 36%, systolic shortening of the global major axis decreased, by, on average, 77% (P < 0.001), shortening of the longitudinal segments by 36% (P < 0.001), and systolic shortening of the minor axis by 18% (P < 0.05), whereas shortening of midwall circumferential segments did not change. This study shows that changes in myocardial contraction in both non-ischaemic and ischaemic regions during coronary insufficiency are most pronounced in the direction of the cardiac major axis.

Acute Disease↗

Myocardial contractility evaluated from cross-oriented segments during beta-adrenergic blockade or sympathetic nerve stimulation.

In patient and experimental models of regions of the left ventricle subjected to ischaemia and thus made dysfunctional it is important to characterize the inotropic state of the remaining myocardium. Eighteen pentobarbitone-anaesthetized open-chest cats with an acute circumflex coronary artery occlusion were therefore studied during either sympathetic nerve stimulation (n = 9), or after beta-adrenergic blockade (n = 9). Myocardial contractility was evaluated from cross-oriented segments in the left ventricular anterior wall during stable haemodynamics and during 5 s inferior caval occlusion. The end-systolic pressure-length relationship of longitudinal segments was rather insensitive to beta-adrenergic blockade and sympathetic nerve stimulation. The end-systolic pressure-length relationship of circumferential segments was suitable as a marker of contractility in the low contractility range, whereas the peak systolic shortening velocity parameter was more suitable in the upper contractility range. The pressure-length loop area versus end-diastolic length relationship of both circumferential and longitudinal segments reflected both increased and decreased left ventricular inotropic state. We therefore conclude that the pressure-length loop area versus end-diastolic length relationship is the best index of regional myocardial contractility in regional ischaemic hearts.

Adrenergic beta-Antagonists↗

Negative inotropic effect of propranolol is attenuated in underperfused feline heart with an acute ischemic region.

beta-Adrenergic blockade alleviates myocardial ischemia, probably largely through heart rate (HR) reduction. We hypothesized that the negative inotropic effect of beta-blockade, which is believed to be potentially dangerous, is attenuated in underperfused hearts with an acute coronary artery occlusion. We studied the effect of intravenous propranolol (1 mg/kg i.v.) in feline hearts with acute circumflex coronary artery (LCX) occlusion by cross-oriented segments in normally perfused and mildly underperfused left ventricular (LV) anterior wall. A control group (n = 10) was compared with a stenosis group (n = 9) in which the mean coronary perfusion pressure was reduced (91 +/- 4 g vs. 136 +/- 5 mm Hg, p < 0.01). End-systolic pressure-length (ESP-ESL) relations during dynamic afterload increase and preload reduction were calculated to evaluate regional inotropy. HR and LV peak systolic blood pressure (LVSP) decreased in both groups after beta-blockade (p < 0.05). Subendocardial and mid-myocardial blood flow measured by radiolabeled microspheres decreased in the control group (p < 0.05) but was unchanged in the stenosis group. Systolic shortening of circumferential segments also decreased in the control group (p < 0.05) but was unchanged in the stenosis group. ESP-ESL relations of circumferential segments shifted markedly rightward in the control group, whereas a modest rightward shift was noted in the stenosis group. This study in feline heart with acute LCX occlusion showed an attenuated negative inotropic effect of beta-blockade in underperfused LV anterior wall.

Animals↗

Is postsystolic shortening area always a marker of myocardial ischaemia?

UNLABELLED: Postsystolic shortening area has been shown to be a sensitive marker of myocardial ischaemia in a one-vessel model. We tested whether postsystolic shortening provoked by interaction between ischaemic and nonischaemic regions is reduced in a two-vessel model, one vessel occluded and one subjected to coronary artery stenosis. Regional function in the left ventricular anterior wall was studied by orthogonal sonomicrometry during left coronary underperfusion in 14 pentobarbital-anaesthetized cats with an acute circumflex coronary artery occlusion. Left coronary underperfusion in two discrete steps decreased subendocardial blood flow in the left ventricular anterior wall to on average 60% (P < 0.001) and 20% (P < 0.001) of control value, while subepicardial flow did not change. End-diastolic lengths of longitudinal segments increased markedly even during mild subendocardial underperfusion, whereas end-diastolic lengths of circumferential segments only increased during severe subendocardial underperfusion with concomitant increase of left ventricular end-diastolic pressure. Systolic shortening, pressure-length loop area and shortening velocity of circumferential segments did not change. In contrast, systolic shortening and total pressure-length loop area of longitudinal segments decreased progressively approaching zero values during severe coronary underperfusion. Shortening velocity of longitudinal segments also decreased progressively during experimental protocol whereas postsystolic shortening area did not change. CONCLUSIONS: postsystolic shortening area is not a marker of subendocardial ischaemia in a two-vessel model which indicates that postsystolic shortening is primarily a phenomenon related to model of ischaemia. End-diastolic lengthening is predominant in the longitudinal axis of the heart during subendocardial ischaemia.

Animals↗

Changes in myocardial contraction pattern during initial reperfusion.

The characteristics of hypercontraction during initial reperfusion were studied in 10 pentobarbitone-anesthetized cats. The left anterior descending coronary artery was occluded for 10 min followed by 1 h of reperfusion, and regional function was assessed by two cross-oriented pairs of sonomicrometers placed in the left ventricular anterior wall. At 1 min of reperfusion (hyperfunctional phase) there was an uniform contraction pattern with 90% recovery of ejection shortening in both circumferential and longitudinal segments. During initial hypercontraction, end-diastolic segment lengths remained unchanged, whereas end-systolic segment lengths decreased transiently. Inotropic stimulation during reperfusion in four additional animals also affected end-systolic lengths more than end-diastolic lengths. This suggests that the initial hyperfunctional phase is due to an inotropic stimulation of the stunned myocardium, most probably caused by intracellular Ca2+ overload. At 5 min of reperfusion a nonuniform contraction pattern had developed with 68% recovery of shortening in circumferential segments vs. 25% in longitudinal segments. The decreased performance in longitudinal segments was paralleled by a delayed start of contraction as well as a decreased velocity of contraction. Because longitudinal segment shortening is a sensitive parameter of subendocardial performance, our results indicate a brief transmural hypercontraction followed by increasing dysfunction (stunning) in the subendocardial layer.

Animals↗

Velocity distributions in the left ventricular outflow tract and the aortic anulus measured with Doppler colour flow mapping in normal subjects.

This study was designed to investigate the velocity distributions in the left ventricular outflow tract and aortic anulus. In 18 out of 22 healthy male individuals, instantaneous cross-sectional flow velocity profiles were constructed at different levels of the left ventricular outflow tract and aortic anulus by time interpolation of digital velocity data from sequentially delayed Doppler colour flow maps. The results showed that: (1) the velocity distributions in the left ventricular outflow tract and the aortic anulus were skewed with the highest velocities along the anterior and septal parts of the flow channel; (2) based on the time-velocity integral profiles in the aortic anulus, which were also skewed with the highest integrals along the anterior and septal parts, the maximal time-velocity integrals were higher than the mean cross-sectional time-velocity integrals by approximately 30% in the four chamber view and 40% in the long axis view. However, the time-velocity integrals at the middle point of the diameter correlated significantly with the mean cross-sectional time-velocity integrals in the four chamber view (10.3 +/- 0.8 vs 9.9 +/- 0.9 cm; r = 0.95) and in the long axis view (12.5 +/- 0.9 vs 11.8 +/- 0.8 cm; r = 0.95). Therefore, it can be concluded that: (1) the velocity distributions in the left ventricular outflow tract and the aortic anulus are skewed; (2) if the aortic anulus is used for cardiac output measurement by pulsed Doppler echocardiography in normal subjects, the middle point of its diameter is the best sampling site.

Adult↗

Non-uniformity of two-dimensional myocardial deformation in response to chronotropic and inotropic stimulation in cats.

The degree of uniformity of myocardial deformation for cross-oriented segments in the anterior wall of the left ventricle is influenced both by loading conditions and by infusion of isoprenaline. The aim of this study was to clarify the chronotropic influence (atrial pacing) compared to the combined inotropic and chronotropic effects of isoprenaline on uniformity of contraction. In eight open-chest pentobarbitone-anaesthetized cats segment performance was measured by orthogonal sonomicrometry. Heart rate (HR) increased from control state, 199 +/- 5 (mean +/- SEM) beats min-1, to 224 +/- 6 and 227 +/- 7 beats min-1 during atrial pacing and isoprenaline infusion, respectively (P < 0.0005). Circumferential segment shortening remained unchanged during pacing but increased with isoprenaline (P < 0.0005). Longitudinal segments showed reduced shortening during pacing (P < 0.05), whereas shortening during isoprenaline infusion did not differ from control shortening. The ratio between shortening of longitudinal and circumferential segments, long/circ ratio, changed from 0.52 +/- 0.13 in the control state to 0.36 +/- 0.10 during pacing and 0.39 +/- 0.11 with isoprenaline (P < 0.05). End-systolic pressure-length relations were unchanged by atrial pacing but showed leftward shifts during isoprenaline infusion. Myocardial tissue blood flow (microspheres) was unchanged during interventions. We conclude that both atrial pacing and isoprenaline infusion lead to a more non-uniform deformation in the anterior wall. However, non-uniformity during atrial pacing was primarily related to reduced longitudinal shortening whereas the non-uniformity during isoprenaline infusion was due to increased circumferential shortening.

Animals↗

The influence of afterload on uniformity of segment shortening in feline left ventricles. Importance of cross-fibre contraction.

Previous studies have shown that the combined increase of preload and afterload leads to a more uniform wall contraction. As our previous information with a stable afterloaded situation showed considerable increase of left ventricular end-diastolic pressure, we have as yet no information of how afterload per se effects uniformity of segment shortening. We therefore analysed maximal systolic shortening of cross-oriented segments for three consecutive beats during abrupt elevation of afterload in 12 open-chest cats. Peak left ventricular systolic pressure increased during the three beats from 154 +/- 5 mmHg (mean +/- SEM) to 167 +/- 5 mmHg and 186 +/- 5 mmHg. Left ventricular end-diastolic pressure remained unchanged. Maximal systolic shortening was reduced for both segments with increasing afterload, in longitudinal segment (LONG) from 7.6 +/- 1.1 to 6.1 +/- 1.0% (P < 0.005), and more pronounced for circumferential segments (CIRC) from 12.2 +/- 0.7 to 8.3 +/- 0.9% (P < 0.0005). Uniformity of maximal systolic shortening, LONG/CIRC, increased from 0.63 +/- 0.08 in the first beat to 0.73 +/- 0.10 and 0.82 +/- 0.12 in the following beats (P < 0.02). We conclude that uniformity of contraction for cross-oriented segments in the anterior left ventricular wall is increased during increased afterload. We propose that this can be explained by reduction of the effect of cross-fibre contraction with increasing afterload.

Analysis of Variance↗