A computer-controlled aortic and mitral valve occluder.

To study cardiac mechanics, it is important to study the beat-to-beat changes in the heart. Left ventricular diastolic filling properties are determined by a passive component and an active component due to ventricular relaxation that occur simultaneously. To separate the active and passive components of ventricular filling, we designed a computer-controlled mitral valve occluder that prevents left ventricular filling. A computer-controlled aortic occluder was designed to change afterload conditions that could affect the components of ventricular filling. Experiments in six dogs demonstrated that these devices effectively control ventricular inflow and ejection on a beat-to-beat basis. The computer-controlled aortic and mitral occluders have a more accurate triggering and occlusion timing system than the previously reported techniques. This computer-controlled device enabled us to separate the passive component of filling from the active component, ventricular relaxation, and to alter afterload simultaneously, which will allow us to develop a better understanding of how ventricular filling and ejection is controlled on a beat-to-beat basis.

Animals↗

TIPS placement in swine, guided by electromagnetic real-time needle tip localization displayed on previously acquired 3-D CT.

PURPOSE: To determine the feasibility of guiding a transjugular intrahepatic portosystemic shunt (TIPS) procedure with an electromagnetic real-time needle tip position sensor coupled to previously acquired 3-dimensional (3-D) computed tomography (CT) images. METHODS: An electromagnetic position sensor was placed at the tip of a Colapinto needle. The real-time position and orientation of the needle tip was then displayed on previously acquired 3-D CT images which were registered with the five swine. Portal vein puncture was then attempted in all animals. RESULTS: The computer calculated accuracy of the position sensor was on average 3 mm. Four of five portal vein punctures were successful. In the successes, only one or two attempts were necessary and success was achieved in minutes. CONCLUSION: A real-time position sensor attached to the tip of a Colapinto needle and coupled to previously acquired 3-D CT images may potentially aid in entering the portal vein during the TIPS procedure.

Animals↗

Temporal CT changes after hepatic and renal interstitial radiotherapy in a canine model.

PURPOSE: The purpose of this work was to define the temporal CT characteristics of hepatic and renal ablation following point-source radioablation utilizing a low energy, photon X-ray source emitted from a miniature probe. METHOD: Twelve mongrel dogs underwent each of three hepatic and two renal point-source radiation ablations. Animals underwent serial, dual phase, spiral CT scans and were killed at 1, 3, and 6 months after treatment. RESULTS: Ablative lesions were clearly visible at 1 month following therapy and consistently diminished in size over the 6 months of follow-up. Lesion size tended to be proportional to dose delivered. Both hepatic and renal lesions were low in attenuation with frequent rim enhancement that diminished over time. Hepatic lesions frequently showed transient hepatic attenuation differences (THADs). Lesion size appeared independent of proximity to vessels. CONCLUSION: Following hepatic or renal interstitial radiotherapy, lesions are generated that are similar in CT appearance to those produced by other ablative techniques. The presence of rim or THAD enhancement can be seen early on as part of the normal tissue-healing response.

Animals↗