Search PubMed⌕ Search

Biomedical subjects

S B Dove

Publications and source records attributed to S B Dove.

At least 37 records · Page 2Linked to original sources

6-bit and 8-bit digital radiography for detecting simulated periodontal lesions.

The purpose of this study was to compare the diagnostic performance of a digital radiography system that uses 6- and 8-bit displays with conventional D-speed film for the detection of simulated periodontal bone lesions. Eleven human hemimandibles were used as specimens. Simulated lesions were created at the buccal cortical plate in the marginal bone area with the use of a round bur 1.4 mm in diameter. Lesions were created in a defined sequence to preclude visual cues as to the depth of the lesions. Lesion size progressed in 0.5 mm increments. At each stage the mandibles were imaged with a Sens-A-Ray system (REGAM Medical Systems AB, Sundsvall, Sweden) and D-speed film. Exposure parameters for each specimen/receptor combination were standardized by either the mean optical density or mean gray value at the approximal crestal bone area. Film images and digital images displayed with 64 and 256 gray levels were presented to six observers for evaluation. Observers were ask to rate their confidence as to the presence or absence of a lesion using a 5-point confidence scale. A total of 96 lesion sites and 96 control sites were presented to the observers. Receiver operating characteristic curves were generated for each system. The area under the curve was used as the index of diagnostic accuracy. The mean receiver operating characteristic areas for 6-bit and 8-bit displays and D-speed film were 0.746 +/- 0.043, 0.717 +/- 0.056 and 0.742 +/- 0.059, respectively. Analysis of variance was used to compare the means. No statistical difference was found between any of the three image displays (p > 0.05).(ABSTRACT TRUNCATED AT 250 WORDS)

Analysis of Variance↗

Clinical comparison of two panoramic modalities and posterior bite-wing radiography in the detection of proximal dental caries.

A clinical study was designed to examine whether the Philips OrthOralix SD (Gendex Dental Systems, Monza, Italy) orthogonal panoramic projection could improve diagnostic accuracy over standard projections in the detection of proximal surface caries. Thirty-five sets of radiographs that demonstrated optimal image characteristics were selected. Using a five-point scale, 18 viewers evaluated whether specified lesions were present or absent. Viewer data was then compared with a consensus radiographic assessment of the state of the proximal areas. Receiver operating characteristic curves were generated with the use of a maximum-likelihood method of fit. The area under the receiver operating characteristic curve was used as the index of diagnostic accuracy. The mean receiver operating characteristic areas for orthogonal and standard projection panoramic and bite-wing radiography to detect the presence of proximal dental caries were 0.68 +/- 0.03, 0.69 +/- 0.03, and 0.79 +/- 0.03 respectively. Critical ratio analysis was used to compare the means for all possible pairings of imaging modalities. In overall performance, conventional bite-wing radiographs gave a significantly greater diagnostic yield for proximal caries than the Philips OrthOralix SD orthogonal or standard panoramic modalities (p > 0.05). The orthogonal projection did not improve diagnostic accuracy in the detection of proximal carious lesions compared with the standard projection.

Dental Caries↗

Radiographic determination of canal length direct digital radiography versus conventional radiography.

This research compared the length determination images produced by Trophy and Regam direct digital radiographic systems with conventional E-speed radiographs. Size #15 K files were placed in the canals of 19 teeth of cadaver specimens and radiographed in a geometrically standardized bench device. Three evaluators estimated the length adjustment necessary to position the file at the apex. The mean estimated adjustment lengths were compared with the true, anatomically determined adjustment lengths. Statistical analysis with analysis of variance and the Student-Newman-Keuls test indicated no significant difference between direct digital thermal print images and conventional radiographs (p > 0.10). Length adjustment estimates with conventional radiographs were significantly more accurate than Regam high-resolution computer monitor images (p < 0.01). Additionally, it was determined that length adjustment estimates were significantly more accurate when the file was placed short of the apex (p < 0.001). The clinical relevance of these differences is discussed.

Analysis of Variance↗

Basic technical properties of a system for direct acquisition of digital intraoral radiographs.

The Sens-A-Ray system for direct digital intraoral radiography may be used with any computer compatible with an IBM PC/AT. The system relies on a charge-coupled device designed for direct conversion of x-ray energy to an electronic signal. It is the first such device for direct acquisition of radiographs. Technical properties of charge-coupled device detectors when exposed to radiation energies in the range of x-rays used in dental radiography have been studied. Even in the absence of light or x-radiation there is a spontaneous generation of charge within a charge-coupled device detector that gives rise to a background signal, a dark current. It was found that the dark current is a linear function of exposure time. The dose response of the charge-coupled device detector was determined at nominal kilovoltages that range from 50 to 90 kVp. The dose response was shown to be a linear function of exposure. The functions for all kVp settings were practically identical. The charge-coupled device detector is more sensitive to x-radiation than conventional dental films and, consequently, its exposure range is more narrow. The signal-to-noise ratio was calculated from the digital radiographs used for the dose response test. The ratio is above 10 for exposures higher than about 2 microC/kg. The line spread function was determined from test radiographs of a 10 microns wide slit in a test object of 1.5 mm thick tantalum. After curve fitting, the line spread function could be expressed as the sum of a Gaussian and an exponential function. Presampling modulation transfer functions valid at the detector plane and at an object plane were calculated from fitted data on the line spread function. It is concluded that the Sens-A-Ray system has such technical properties that it may replace conventional film-based systems.

Computer Graphics↗

Dimensional reproduction in direct digital rotational panoramic radiography.

A linear x-ray detector array can be used to perform rotational panoramic radiography provided a technique for data acquisition is used that emulates the dimensional reproduction of a conventional rotational panoramic radiographic system. This may be accomplished with the use of a variable integration time throughout the excursion. The required interval depends upon the scanning geometry, the selected image plane, and the size of pixels used in the digital image. In a prototype device developed around an Orthopantomograph Model OP10 with 0.225 mm square pixels, the integration times range from about 8 milliseconds to 28 milliseconds. An experimental test was performed by radiographing a number of steel spheres positioned at different object depths. Within the limits of experimental error, there was satisfactory agreement between the measured and theoretical magnification.

Humans↗

Digital subtraction temporomandibular joint tomography.

Receiver operating characteristics analysis was performed to demonstrate differences in diagnostic performance among conventional tomograms, digitized tomograms, and subtraction tomograms. Digital subtraction tomography was found to be the best imaging modality for detecting artificially created lesions in the two selected temporomandibular joint locations. There was a statistically significant difference in diagnostic performance between conventional tomograms and subtraction tomograms for the detection of temporomandibular joint bony lesions. There was also a statistically significant difference in diagnostic performance between digitized tomograms and subtraction tomograms in the detection of these bony lesions. There was no statistically significant difference in diagnostic performance between conventional tomograms and digitized tomograms for the detection of temporomandibular joint bony lesions. The significance level was set at p = 0.05. Results of the analyses of variance showed that with digital subtraction tomograms, observer reliabilities were higher than with conventional and digitized tomograms.

Evaluation Studies as Topic↗

An in vitro study of the characteristics of a computer-aided radiographic evaluation (CARE) system for longitudinal assessment of density changes.

In recent years, several systems for computerized analysis of radiographs have been introduced, most of which use digital conversion of the image followed by subtraction of consecutive images to assess changes. This paper introduces a computer-based qualitative and quantitative radiographic evaluation system based on the CADIA algorithm. Problems associated with computerized radiographic analysis are discussed and evaluation criteria for this type of system are suggested. These criteria include evaluation of system noise and threshold setting, reproducibility, and establishment of the system working curve (validity). The CARE system noise ranged from a -10 to +10 CADIA value and the threshold was set on 13 for all measurements. The reproducibility was high, both for the radiographic technique and for repeated measurements. The working curve was established and showed the system's ability to detect small density changes of 0.048 O.D. which corresponds to 0.27 mm of aluminium thickness or compact bone equivalent. The linear range of the curve was between 0.7 and 1.8 O.D. By controlling the exposure parameters it was possible to work within the linear range of the curve. Based on these evaluation criteria, the CARE system can be used to quantitatively evaluate small density changes on sequential radiographs for early detection of caries and periodontal disease.

Alveolar Bone Loss↗

Digital panoramic and extraoral imaging.

Intraoral, panoramic, and extraoral radiographs are the primary means of diagnosing hard-tissue disorders of the dentomaxillofacial region. These imaging methods require the use of x-ray film and subsequent chemical processing to produce diagnostic images. A goal of recent research has been the replacement of this film-based technology with computer-based devices that use electronic or storage phosphor receptors to record the x-ray image in a digital format. This article discusses some of these emerging technologies and their potential effect on the future of panoramic and extraoral radiology.

Humans↗

Preliminary evaluation of a digital system for rotational panoramic radiography.

A prototype system for direct digital panoramic radiography has been evaluated with respect to density, contrast, magnification, distortion, resolution, and overall image quality. Density and contrast depend on detector calibration and may be modified by the display system or by digital processing of the captured image. Variation of magnification in the horizontal and vertical dimensions gives rise to distortion phenomena that are identical to those encountered in film-based systems. Resolution in the vertical dimension is determined by the pitch of the detector elements. In the horizontal dimension, resolution is limited by the effective width of the detector elements. To evaluate the clinical acceptability of the images, radiologists and general practice residents were asked to assess the perceptibility of important radiographic landmarks in film-based and digital images of both a radiographic phantom and a patient. The digital system performed on a par with film in the representation of normal morphologic structures of the clinical human subject whereas more differences were apparent in the phantom images. The general practice residents consistently rated the digital images higher than their radiologist counterparts did. No consistent trends were found to indicate any inherent deficiencies of the digital system in the depiction of any one area. The results indicate the promise of direct digital acquisition as a method of panoramic imaging.

Evaluation Studies as Topic↗

Magnetic resonance spectroscopy of inflammation associated with the temporomandibular joint.

Noninvasive early recognition and treatment of temporomandibular joint dysfunction remains a diagnostic challenge. This pilot study evaluated the use of phosphorus 31 magnetic resonance spectroscopy with magnetic resonance imaging to measure alterations in pH and high-energy phosphate metabolite ratios of muscle that is adjacent to an inflamed temporomandibular joint. Ten New Zealand white rabbits were used in this study. Two animals were used to develop signal acquisition protocols and to ensure that stable baseline data could be measured. In each of the eight animals used in the experiment, one temporomandibular joint was injected with a suspension of silica particles and the contralateral joint served as a control. Data were collected from control and experimental joints on days 0, 7, 14, 21, and 28, after the injection. At the end of the study, temporomandibular joints were block resected and histologically examined to confirm the presence of an inflammatory response. Results indicated that pH and metabolite ratios could be obtained by 31P-magnetic resonance spectroscopy. Changes in pH and some metabolite ratios in experimental joints showed statistical significance (p < 0.001). Differences were seen on day 2 and day 7 (p = 0.040 and p = 0.008, respectively) in the phosphocreatine/alpha-adenosine triphosphate ratios. This contrasts with phosphocreatine/beta adenosine triphosphate ratios that showed significance that began at day 7 (p = 0.022) and continued to day 14 (p = 0.025). Histologic examination indicated that the tissue response within the joint capsule was less than the granulomatous reaction expected.(ABSTRACT TRUNCATED AT 250 WORDS)

Adenosine Triphosphate↗

Direct digital radiography for the detection of periodontal bone lesions.

In this study the diagnostic accuracy of D-speed and E-speed film in the detection of simulated periodontal bone lesions was compared with that of an electronic direct digital image receptor. Lesions of increasing depth were created in 11 human hemimandibles at the buccal cortical plate in the interproximal marginal bone area by means of 1.4 mm diameter round bursa. Specimens were imaged at each lesion stage with the use of all three receptors. Nine viewers used a 5-point rating scale to evaluate whether lesions were present or absent in the resulting images. Receiver operating characteristic curves were generated, and maximum-likelihood curve areas were calculated. The area under the curve was used as the index of diagnostic accuracy. The mean receiver operating characteristic areas for D-speed film, E-speed film, and the direct digital system were 0.745 +/- 0.038, 0.740 +/- 0.038, and 0.741 +/- 0.037, respectively. Critical ratio analysis was used to compare the means. No statistical difference was found between any of the three image receptors (p > 0.05) for the detection of simulated periodontal lesions 1.0 to 3.0 mm in depth, which suggested that the digital system performed comparably with conventional film systems.

Alveolar Bone Loss↗

Direct digital extraoral radiography of the head and neck with a solid-state linear x-ray detector.

A narrow fan beam of x-rays intercepted by a linear array detector was used to acquire transmission data for a radiographic phantom moved across the beam. The digital data were displayed as images representing a variety of extraoral views of the head and neck. Projections investigated include the straight lateral view, two frontal projections, and a half-axial projection. The digital images appear to provide adequate contrast and resolution for common diagnostic tasks. In addition, the use of a scanning linear detector reduces the amount of scatter, which increases contrast relative to images made with an area detector. The system appears to provide a versatile and convenient means for the acquisition of extraoral views relevant to dental practice while it eliminates the logistical difficulties and errors associated with film processing.

Analog-Digital Conversion↗

Assessment of external root resorption using digital subtraction radiography.

Digital subtraction radiography was investigated for its capability to detect and quantify experimentally produced external root resorptive defects in teeth. Using a long source to object X-ray technique and E-speed film, serial radiographs of teeth with artificial lesions in a dry human skull (soft tissue simulated) were obtained. Receiver operating characteristic analysis was used to evaluate the diagnostic performance for each imaging system (conventional versus subtraction). To explore the quantitative assessment potential of digital subtraction radiography, images were produced after sequential demineralization by HCl. The acid solution was analyzed for calcium concentration by atomic absorption spectrophotometry. Three-dimensional histogram quantification for each subtracted image was performed. In overall performance for detecting experimentally produced external root resorption, digital subtraction radiography was found to be significantly superior to conventional radiography. In addition, digital subtraction radiography can provide quantification of experimentally produced external root resorptive defects.

Humans↗

CT reconstruction algorithm for a dental panoramic x-ray unit.

A variable Jacobian and weighted backprojection algorithm, used for medical CT, was adapted to perform CT reconstructions on data obtained with a dental panoramic x-ray unit. A detector array, fitted to the unit for the purpose of acquiring digital panoramic radiographs, was used to collect the data. Compensations were made for the incomplete (230 degrees) rotation of the panoramic x-ray unit, the non-fixed centre of rotation, the irregular rotation of the x-ray target and detector, and the resulting variances in magnification. The algorithm was tested on mathematically simulated phantoms and on acquired data. Reconstruction of simulated data proved the success of the algorithm. Real data reconstructions showed some defects as a result of inaccuracies in quantifying the experimental panoramic device.

Algorithms↗

Morphometric analysis of the dental pulp chamber as a method of age determination in humans.

Eighty bite-wing radiographs from 40 female and 40 male patients were selected from the patient record system at the University of Texas Dental School at San Antonio, Texas. All samples were equally divided into four age groups, with a range from 15 to 55 years of age. The lower right first permanent molar tooth was chosen as the representative tooth for measuring the maximum height and width of the pulp chamber. The reproducibility of the method was checked by repeating all measurements on two different occasions. Regression analysis indicates that the height and width of the pulp chamber were negatively correlated with age (height r = -0.376 and width r = -0.125). The coefficient of determination (r2) for pulp chamber height and width were 0.123 and 0.058, respectively. This indicates that although there appears to be a definite relationship between the age of an individual and the height and width of the dental pulp chamber, these measures cannot be used as a reliable method of age determination.

Adolescent↗

Digital subtraction radiography in artificial recurrent caries detection.

The diagnostic accuracy of digital subtraction radiography in detection of artificial recurrent caries lesions was assessed in this project. The use of digital subtraction radiography has been shown to markedly increase the accuracy of the detection of destruction in the periodontal bone, but the method has not been evaluated in secondary caries detection. Defects of three different sizes, simulating recurrent caries, were sequentially prepared in the interproximal cavity preparation margins of 28 teeth. Two composite restorative materials with different radiographic densities were used as posterior restorations, and a radiograph was obtained of each defect size and restorative material. The radiographs were digitized and subtracted from the reference images, and the conventional radiographs and the subtraction images were evaluated by seven observers. The data were analysed with ROC statistics. Subtraction radiography was found to be superior to conventional radiography in recurrent caries detection, mainly by reducing the false-positive diagnoses. The radiopacity of the restorative material had a significant effect on accuracy with conventional but not with subtraction radiography.

Analysis of Variance↗

A comparison of conventional intra-oral radiography and computer imaging techniques for the detection of proximal surface dental caries.

The detection of proximal surface caries by the visual interpretation of bitewing radiographs is known to be relatively inaccurate. The present study was designed to examine whether computer image processing could improve the diagnostic accuracy. A computer-aided, software-driven, TV-based system was used to digitize conventional radiographs and digitally process the images using histogram equalization and grey-scale inversion to enhance the images. The computer-enhanced images were compared with conventional intra-oral radiographs for the detection of proximal surface caries using receiver operating characteristic analysis. The results indicate that the digital image processing techniques used did not improve the diagnostic accuracy of dental radiographs. No significant difference in diagnostic accuracy could be detected between the non-enhanced digital images and conventional film-based images for the detection of proximal surface caries.

Dental Caries↗

Design and implementation of an image management and communications system (IMACS) for dentomaxillofacial radiology.

An Image Management and Communications System for digital dentomaxillofacial radiology is under development at the Department of Dental Diagnostic Science at the University of Texas Health Science Center at San Antonio, Texas, USA. In its final stage, the system will provide a method of integrating different direct digital image acquisition modalities such as intraoral, panoramic and extraoral radiography. A review of the design criteria necessary for establishing such a system for clinical dentistry is discussed and the first phase of its implementation described.

Computer Communication Networks↗