Search PubMed⌕ Search

Biomedical subjects

S Amerio

Publications and source records attributed to S Amerio.

45 records · Page 3Linked to original sources

First measurements of inclusive W and Z cross sections from run II of the fermilab tevatron collider.

We report the first measurements of inclusive W and Z cross sections times leptonic branching ratios for pp collisions at square root[s]=1.96 TeV, based on their decays to electrons and muons. The data correspond to an integrated luminosity of 72 pb(-1) recorded with the CDF detector at the Fermilab Tevatron. We test e-mu universality in W decays, and we measure the ratio of leptonic W and Z rates from which the leptonic branching fraction B(W-->lnu) can be extracted as well as an indirect value for the total width of the W and the Cabibbo-Kobayashi-Maskawa matrix element, |V(cs)|.

Journal Article↗

Measurement of Wgamma and Zgamma production in pp collisions at square root s=1.96 TeV.

The standard model predictions for Wgamma and Zgamma production are tested using an integrated luminosity of 200 pb(-1) of pp collision data collected at the Collider Detector at Fermilab. The cross sections are measured by selecting leptonic decays of the W and Z bosons, and photons with transverse energy ET>7 GeV that are well separated from leptons. The production cross sections and kinematic distributions for the Wgamma and Zgamma data are compared to SM predictions.

Journal Article↗

Search for doubly charged Higgs bosons decaying to dileptons in pp collisions at square root of s=1.96 TeV.

We present the results of a search for doubly charged Higgs bosons (H+/-+/-) decaying to dileptons (ll(')) using approximately 240 pb(-1) of pp collision data collected by the CDF II experiment at the Fermilab Tevatron. In our search region, given by same-sign ll(') mass m(ll('))>80 GeV/c(2) (100 GeV/c(2) for ee channel), we observe no evidence for H+/-+/- production. We set limits on sigma(pp -->H++H---->l(+)l('+)l(-)l('-)) as a function of the mass of the H+/-+/- and the chirality of its couplings. Assuming exclusive same-sign dilepton decays, we derive lower mass limits on H(+/-+/-)(L) of 133, 136, and 115 GeV/c(2) in the ee, mumu, and emu channels, respectively, and a lower mass limit of 113 GeV/c(2) on H(+/-+/-)(R) in the mumu channel, all at the 95% confidence level.

Journal Article↗

Measurement of the tt production cross section in pp collisions at sqrt[s]=1.96 TeV using dilepton events.

We report a measurement of the tt production cross section using dilepton events with jets and missing transverse energy in pp collisions at a center-of-mass energy of 1.96 TeV. Using a 197+/-12 pb(-1) data sample recorded by the upgraded Collider Detector at Fermilab, we use two complementary techniques to select candidate events. We compare the number of observed events and selected kinematical distributions with the predictions of the standard model and find good agreement. The combined result of the two techniques yields a tt production cross section of 7.0(+2.4)(-2.1)(stat)+1.6-1.1(syst)+/-0.4(lum) pb.

Journal Article↗

Two-dimensional and quasi-three-dimensional dosimetry of hadron and photon beams with the Magic Cube and the Pixel Ionization Chamber.

Two detectors for fast two-dimensional (2D) and quasi-three-dimensional (quasi-3D) verification of the dose delivered by radiotherapy beams have been developed at University and Istituto Nazionale di Fisica Nucleare (INFN) of Torino. The Magic Cube is a stack of strip-segmented ionization chambers interleaved with water-equivalent slabs. The parallel plate ionization chambers have a sensitive area of 24 x 24 cm2, and consist of 0.375 cm wide and 24 cm long strips. There are a total of 64 strips per chamber. The Magic Cube has been tested with the clinical proton beam at Loma Linda University Medical Centre (LLUMC), and was shown to be capable of fast and precise quasi-3D dose verification. The Pixel Ionization Chamber (PXC) is a detector with pixel anode segmentation. It is a 32 x 32 matrix of 1024 cylindrical ionization cells arranged in a square 24 x 24 cm2 area. Each cell has 0.4 cm diameter and 0.55 cm height, at a pitch of 0.75 cm separates the centre of adjacent cells. The sensitive volume of each single ionization cell is 0.07 cm3. The detectors are read out using custom designed front-end microelectronics and a personal computer-based data acquisition system. The PXC has been used to verify dynamic intensity-modulated radiotherapy for head-and-neck and breast cancers.

Calibration↗

Observation of the narrow state X(3872)-->J/psipi+pi- in pp collisions at sqaure root of s=1.96 TeV.

We report the observation of a narrow state decaying into J/psipi+pi- and produced in 220 pb(-1) of p p-bar collisions at =1.96 Tesqaure root of sV in the CDF II experiment. We observe 730+/-90 decays. The mass is measured to be 3871.3+/-0.7(stat)+/-0.4(syst) MeV/c2, with an observed width consistent with the detector resolution. This is in agreement with the recent observation by the Belle Collaboration of the X(3872) meson.

Journal Article↗

Search for B0s-->micro+micro- and B0d-->micro+micro- decays in pp collisions at square root s = 1.96 TeV.

We report on a search for B(0)(s)-->micro(+)micro(-) and B(0)(d)-->micro(+)micro(-) decays in pp collisions at square root of s=1.96 TeV using 171 pb(-1) of data collected by the CDF II experiment at the Fermilab Tevatron Collider. The decay rates of these rare processes are sensitive to contributions from physics beyond the standard model. One event survives all our selection requirements, consistent with the background expectation. We derive branching ratio limits of B(B(0)(s)-->micro(+)micro(-))<5.8x10(-7) and B(B(0)(d)-->micro(+)micro(-))<1.5x10(-7) at 90% confidence level.

Journal Article↗

Dosimetric characterization of a large area pixel-segmented ionization chamber.

A pixel-segmented ionization chamber has been designed and built by Torino University and INFN. The detector features a 24 x 24 cm2 active area divided in 1024 independent cylindrical ionization chambers and can be read out in 500 micros without introducing dead time; the digital charge quantum can be adjusted between 100 fC and 800 fC. The sensitive volume of each single ionization chamber is 0.07 cm3. The purpose of the detector is to ease the two-dimensional (2D) verifications of fields with complex shapes and large gradients. The detector was characterized in a PMMA phantom using 60Co and 6 MV x-ray photon beams. It has shown good signal linearity with respect to dose and dose rate to water. The average sensitivity of a single ionization chamber was 2.1 nC/Gy, constant within 0.5% over one month of daily measurements. Charge collection efficiency was 0.985 at the operating polarization voltage of 400 V and 3.5 Gy/min dose rate. Tissue maximum ratio and output factor have been compared with a Farmer ionization chamber and were found in good agreement. The dose profiles have been compared with the ones obtained with an ionization chamber in water phantom for the field sizes supplied by a 3D-Line dynamic multileaf collimator. These results show that this detector can be used for 2D dosimetry of x-ray photon beams, supplying a good spatial resolution and sensibly reducing the time spent in dosimetric verification of complex radiation fields.

Algorithms↗

Long-term treatment of essential arterial hypertension with nitrendipine.

The efficacy and safety of long-term treatment with oral nitrendipine were evaluated in 34 patients with essential arterial hypertension. Nitrendipine alone significantly lowered systolic and diastolic blood pressure levels in 28 patients who completed the preliminary four-week dose-setting phase. Twenty-one patients completed the one-year treatment. Blood pressure control was maintained by nitrendipine alone in 11 patients. Ten patients not adequately controlled at the end of the dose-setting phase were successfully treated with nitrendipine combined with acebutolol or muzolimine. It is concluded that nitrendipine is a promising calcium antagonist for the treatment of arterial hypertension.

Acebutolol↗