Radiation transport in a radiotherapy room.

The photoneutron dose equivalent in a linac radiotherapy room and its entrance maze was investigated by means of Monte Carlo simulations under different conditions. Particularly, the effect of neutron absorbers and moderator layers placed on the maze walls was considered. The contribution of prompt gamma rays emitted in absorption reactions of thermal neutrons was also taken into account. The simulation results are compared with some experimental measurements in the therapy room and in the maze.

Gamma Rays↗

Discrimination of various contributions to the absorbed dose in BNCT: Fricke-gel imaging and intercomparison with other experimental results.

A method is described for the 3D measurements of absorbed dose in a ferrous sulphate gel phantom, exposed in the thermal column of a nuclear reactor. The method, studied for Boron Neutron Capture Therapy (BNCT) purposes, allows absorbed dose imaging and profiling, with the separation of different contributions coming from different secondary radiations, generated from thermal neutrons. In fact, the biological effectiveness of the different radiations is different. Tests with conventional dosimeters were performed too.

Boron Neutron Capture Therapy↗

Neutron measurements around medical electron accelerators by active and passive detection techniques.

Passive and active detection techniques have been employed in order to measure neutron fluence rates and corresponding exposure rates around medical electron accelerators operating at energies well above the neutron binding energies of the structural materials. In these conditions from the treatment head, in the direct photon flux and from the shielded region, a fast neutron flux emerges which is partly absorbed and partly scattered by the walls, eventually establishing a nearly uniform thermal and epithermal flux in the room. Both direct and scattered flux contribute to the dose to the patient. A smaller neutron dose rate can also be found outside the treatment room, where the therapy staff works. Passive detectors, of moderation type, have been employed in the treatment room and 3He active detectors in the external zones. For the treatment room the activation data were compared with results of Monte Carlo simulation of the neutron transport in the room. Technical features of the two measures are briefly presented and results obtained around three different types of accelerators are reported. At the higher beam energies, i.e., 25 MV, a neutron dose of 0.36 Sv was estimated in the treatment field in addition to a therapeutic x-ray dose of 50 Gy. At lower energies or out of the treatment field the neutron dose drops significantly. In the external zones the dose rates everywhere are below the recommended limits and normally very low, the highest values being recorded in positions very close to the access door of the treatment room.

Humans↗

Neutron fluxes in radiotherapy rooms.

The spatial distribution of the neutron flux, originated in an electron accelerator therapy room when energies above the threshold of (y,n) and (e,e'n) reactions are employed, is physically due to a direct flux, coming from the accelerator head, and to a flux diffused from the walls. In this work, the flux is described to a high degree of approximation by a set of functions whose spatial behavior is univocally determined by the angular distributions of the neutrons emitted from the shield of the accelerator head and diffused from the walls. The analytical results are verified with an extended series of Monte Carlo simulations obtained with the MCNP code.

Monte Carlo Method↗