S A Siddiqui

Publications and source records attributed to S A Siddiqui.

At least 19 recordsLinked to original sources

Dosimetry of a low-kV intra-operative X-ray source using basic analytical beam models.

The low energy (30-50 kVp) beams from an intra-operative X-ray source are modelled using a basic analytical model considering just primary beam attenuation and absorption. Spatial dosimetry at such low energies is difficult due to the rapid changes in dose-rate from the radiation source. The purpose of the model was to determine the variation with distance in water of coefficients required for beam dosimetry and to validate beam measurements performed in water of high-gradient dose distributions. The model predicts a change in mean mass-energy absorption coefficient of up to 3 % over the range of clinically-relevant distances in water. Distance-dose distributions (variation in dose with distance in water) for the X-ray source were calculated with the model and found to be in agreement with measurement (at clinically-relevant distances), to within a spatial distance comparable to the dimensions and positional accuracy of the ionization chamber used, and comparable to the expected dosimetric anisotropy of the radiation source. Measured and calculated distance-doses begin to diverge at relatively large distances from the radiation source, which is where dose-rates are so low that detector signal levels are comparable with noise.

Absorption↗

Structural basis for the activity of pp60(c-src) protein tyrosine kinase inhibitors.

Conformational searches on three closely related pp60(c-src) protein tyrosine kinase inhibitors of varying potencies were performed to determine a structural basis for their activity. The first was a linear peptide (PDNEYAFFQf), the second its 10-membered cyclic analogue, and the third a cyclic analogue with a para carboxyphenylalanine in place of one the F residues. A common backbone conformation with an antiparallel beta-sheet-like geometry capped by similar beta-turns was found for all three peptides, which may be a binding conformation and gives a candidate pharmacophore for further testing. The interaction between some polar side chains and between some of the aromatic rings may be important for maintaining the correct conformation. The differences in potencies of these inhibitors may be attributed to certain thermodynamic and chemical reasons.

Amino Acid Sequence↗

Dual ectopic thyroid: a report of two cases.

Ectopic thyroid is an uncommon embryological aberration characterized by the presence of thyroid tissue at a site other than in its usual pretracheal region. Usually it occurs along the path of descent of the developing thyroid primodium from the foramen caecum, commonest being lingual followed by sublingual and in the anterior midline of neck at, or below, the level of the hyoid bone. It is unusual for lingual thyroid to present simultaneously with another ectopic thyroid; reported here are two such cases.

Adolescent↗

Granulocytic sarcoma in patients with chronic myeloid leukaemia.

Granulocytic sarcoma is an unusual variant of myeloid malignancy most commonly encountered in the course of chronic or acute myeloid leukaemia. Of 60 patients of chronic myeloid leukaemia studied over 21 months, we encountered 6 (10%) cases of granulocytic sarcoma. Four of these had granulocytic sarcoma on their first presentation. All those who were receiving hydroxyurea did not fare well but one who was put on DAT (daunorubicin, cyftosine arabinocide, 6 thioguanine)regimen went into remission with complete disappearance of lesions.

Adolescent↗

Incidence & immunological profile of multiple myeloma patients.

Multiple myeloma was diagnosed in 84 residents of Jammu & Kashmir between 1984-1988. The data were analyzed for variations of demographic factors, ethnicity and location of residence (urban/rural). The average annual incidence per 100,000 residents was 1.28. The rates for males and females were 2.02 and 0.71 per 10(5) persons/year respectively. The average incidence rate for Muslims was significantly higher than that for Hindus. Urban residents had significantly higher rates than rural population. Highest incidence rate (14.39) was in the age group of 65 yr and above.

Adult↗

Haemostatic clips and clamps used in surgical neurology with special reference to non ferro magnetic Phynox spring clips by Aesculap.

This paper concerns the historical developments and technical properties of haemostatic devices used in neurosurgery with the exception of coagulation. Therefore there are described haemostatic clips designed for the scalp, clips used on arteries and veins, a clamp for the reduction of the carotid diameter in the neck, and a clamp for closing the venous dural sinuses. Special reference will be made regarding non ferro magnetic Phynox clips by Aesculap.

Hemostasis, Surgical↗

Cardiovascular effects produced by a combination of d-tubocurarine and pancuronium in dogs.

The effect on the cardiovascular system of a combination of pancuronium (0.048 mg/kg) and d-tubocurarine (0.288 mg/kg) was studied in five conditioned dogs anesthetized with fentanyl. Changes in heart rate, mean arterial pressure, central venous pressure, mean pulmonary artery pressure, pulmonary capillary wedge pressure, stroke volume, cardiac output, systemic vascular resistance and pulmonary vascular resistance were recorded 2, 5, 10, 20, 30, 40 and 50 minutes after administration of the drug combination. Arterial blood samples were assayed for estimation of histamine levels. There was a significant fall in central venous pressure and mean arterial pressure at 2 minutes (p less than 0.05) and a significant rise in heart rate at 2 and 5 minutes (p less than 0.05). These changes were not significant at 10 minutes. There was no significant change in the other parameters measured and no significant release of histamine. It is concluded that the smaller doses of pancuronium and d-tubocurarine used in combination in dogs do not completely attenuate the cardiovascular effects of either drug when used independently, but that the changes are transient and no longer significant at 10 minutes.

Animals↗

A semi automated procedure for the measurement of 3-methoxy-4 hydroxy mandelic acid.

A semi automated procedure for the determination of 3-methoxy-4-hydroxy-mandelic acid (HMMA) in urine has been evaluated. This procedure offers advantages in simplicity, speed and precision over existing manual techniques which utilize spectrophotometric fluorimetric and gas liquid chromatographic methods. The urine is extracted with ethyl acetate from a highly acidic sample, purified by extraction into acetate buffer and the diazo colour reaction developed. All stages of the procedure are carried out using the Brown and semi-automatic extractor equipped with partition tube. The within and between assay coefficient of variation obtained on pooled freeze-dried urine samples was 6.7% and 7.7% respectively.

Autoanalysis↗

Laboratory assessment of thyroid disorders - which test should be used?

There are a variety of laboratory investigations which have been used in the assessment of thyroid function and it is obvious that not all of these tests can be used on each occasion. Which, therefore, provides the best diagnostic index? Each test is designed to assess a particular aspect of the thyroid gland and it is often not possible to select a single test as an ideal and exclude the others. The data presented in this paper indicate the advantages of using a combination of various procedures as a screening profile to cover all thyroid abnormalities. The results of several thyroid tests accumulated over the past five years are critically examined to assess their diagnostic value separately and in selected groups. Introduction.

Humans↗

A comparative study of five laboratory tests for foeto-placental dysfunction in late pregnancy.

Five foeto-placental function tests were studied in parallel in normal and abnormal late pregnancies with a view to establishing which test or tests is most satisfactorily able to identify the mother whose foetus is in danger.A critical examination of the levels in blood serum of two enzymes, placental phosphatase isoenzyme and cystine aminopeptidase, the polypeptide hormone placental lactogen (chorionic somatomammotrophin), and the oestrogen oestriol-17beta is described.A correlation was attempted beween clinical data and the results of the above laboratory analyses and also with the daily urine oestrogen output. The plasma and urine oestriol levels proved generally to be the more useful warning tests in late pregnancy, whilst the plasma cystine aminopeptidase was the least sensitive indicator of foeto-placental dysfunction.

Aminopeptidases↗