Search PubMed⌕ Search

Biomedical subjects

Ryan F Paterson

Publications and source records attributed to Ryan F Paterson.

36 records · Page 2Linked to original sources

Holmium laser enucleation of prostate (HoLEP): the Methodist Hospital experience with greater than 75 gram enucleations.

PURPOSE: Holmium laser enucleation of the prostate (HoLEP) effectively removes obstructive prostate tissue in minimally invasive fashion. We present our large enucleation outcomes (greater than 75 gm retrieved). We examined post-procedural prostate specific antigen (PSA) and transrectal ultrasound (TRUS) volume changes to assess tissue removal completeness. MATERIALS AND METHODS: We retrospectively reviewed HoLEPs performed from April 1, 1999 through September 30, 2002 to identify all enucleations greater than 75 gm. Demographic, laboratory, operative and pathological data were obtained. Patients were surveyed to document longer term complications. RESULTS: The cohort of 108 patients had a mean age and specimen weight of 71.5 years (range 53 to 90) and 120.6 gm (range 75.3 to 376), respectively. Average procedural time and hospital stay were 166.8 minutes (range 75 to 473) and 1.2 days (range 0 to 4), respectively. No deaths or episodes of transurethral resection syndrome occurred. Postoperative complications included transfusion in 2 cases, a clot retention episode in 3, capsular perforation in 2, morcellator blade malfunction in 4, minor bladder mucosal injury in 1 and bladder neck contracture in 1. American Urological Association symptom scores reassessed in 53 patients without chronic retention an average +/- SD of 10.6 +/- 7.1 months postoperatively showed a mean decrease from 20.3 +/- 6.4 to 4.7 +/- 3.8. PSA in 48 patients a mean of 5.0 +/- 4.1 months postoperatively had decreased an average of 91.7%. In 10 patients TRUS data revealed a mean post-procedural volume decrease of 85.9%. CONCLUSIONS: HoLEP can be performed on extremely large prostates with minimal risk or need for secondary interventions. Most patients are discharged home after an overnight stay. Postoperative decreases in PSA and TRUS volumes support the completeness of enucleation that can be achieved.

Adenocarcinoma↗

In vitro assessment of ultrasonic lithotriptors.

PURPOSE: Ultrasonic lithotriptors are commonly used to fragment and remove stones during percutaneous nephrolithotomy. To date a comparative assessment of current units has not been accomplished without potential operator bias. An objective testing environment is required for optimal appraisal of the efficiency of ultrasonic lithotriptors. MATERIALS AND METHODS: An in vitro test system was devised to evaluate the ability of ultrasonic lithotriptors to core through artificial stones. The system consisted of an irrigation sheath (Cook Urological, Spencer, Indiana) through which ultrasonic probes were placed. Ultrasonic hand pieces and probes were secured in an upright position. An Ultracal-30 (U.S. Gypsum, Chicago, Illinois) stone cylinder (mean length 12.8 +/- 0.6 mm, mean diameter 7.6 +/- 0.07 mm) was centered on the probe tip. A weight (62.7 gm) was placed atop the stone to provide a constant force. We evaluated the Olympus LUS-1 and LUS-2 (Olympus, Melville, New York), Circon-ACMI USL-2000 (Circon-ACMI, Southborough, Massachusetts), Karl Storz Calcuson (Karl Storz, Culver City, California) and Richard Wolf model 2271.004 (Richard Wolf, Vernon Hills, Illinois). All probes had outer diameters of 3.4 mm except for the Circon-ACMI unit (3.8 mm). Using 100% power settings times for complete stone penetration were assessed for all units. Differences in mean stone penetration times were compared using ANOVA. RESULTS: The Olympus LUS-2 had the fastest mean stone penetration time (28.8 +/- 2.7 seconds). This value was used to normalize the data into efficiency ratios, where other unit times were expressed as multiples of the LUS-2 time: Olympus LUS-2 (1.0 +/- 0.1) equals Circon-ACMI USL-2000 (1.1 +/- 0.3) greater than Karl Storz Calcuson (1.4 +/- 0.3) greater than Olympus LUS-1 (2.1 +/- 0.5) greater than Richard Wolf (3.6 +/- 0.8). Efficiencies of the LUS-2 and USL-2000 units were essentially equivalent, with all others significantly less efficient (p <0.05). CONCLUSIONS: This new in vitro testing model provides an objective, reproducible method for evaluating the efficiency of intracorporeal lithotriptors. Of the units tested the Olympus LUS-2 and Circon-ACMI USL-2000 were the most efficient.

Equipment Design↗

Endoscopic renal papillary biopsies: a tissue retrieval technique for histological studies in patients with nephrolithiasis.

PURPOSE: The mechanisms behind calcium nephrolithiasis remain unclear. Previous research has relied on animal models or cell lines, yielding limited insight into the pathophysiology of human calcium stone disease. To determine changes occurring in the human kidney during active stone disease we used an endoscopic renal papillary biopsy protocol in calcium stone formers undergoing percutaneous nephrolithotomy. MATERIALS AND METHODS: Following stone burden clearance via percutaneous nephrolithotomy 15 idiopathic calcium oxalate and 4 ileal bypass stone formers underwent flexible and rigid nephroscopy. Biopsies from select papillae in the peripheral and interpolar regions were obtained with 5Fr flexible cup biopsy forceps. A papilla adjacent to the accessed calix was biopsied with 10Fr cup biopsy forceps. Cortical biopsies along the access tract were also obtained with the 10Fr forceps. RESULTS: All patients had successful biopsy completion. No complications were attributable to the biopsy process and no blood transfusions were required. Of the 19 patients 12 were contacted for followup at a mean of 21.7 +/- 9.0 months with none experiencing adverse sequelae such as bleeding or significant pain. A total of 14 patients had followup serum creatinine available showing that the difference in mean preoperative and postoperative values was not clinically significant (1.00 +/- 0.27 and 1.11 +/- 0.27 mg/dl, respectively). The quality of biopsied tissue permitted accurate immunohistochemical staining of crystal deposits and mineral analysis. CONCLUSIONS: Endoscopic papillary biopsies were performed safely in a small patient population. Tissue obtained using this protocol can be used for detailed histological and analytical studies, which may lead to significant advances in our understanding of stone formation mechanisms.

Biopsy↗

Renal nerves mediate changes in contralateral renal blood flow after extracorporeal shockwave lithotripsy.

Renal blood flow falls in both kidneys following delivery of a clinical dose of shockwaves (SW) (2000 SW, 24 kV, Dornier HM3) to only one kidney. The role of renal nerves in this response was examined in a porcine model of renal denervation. Six-week-old pigs underwent unilateral renal denervation. Nerves along the renal artery of one kidney were identified, sectioned and painted with 10% phenol. Two weeks later the pigs were anesthetized and baseline renal function was determined using inulin and PAH clearances. Animals then had either sham-shockwave lithotripsy (SWL) (group 1), SWL to the innervated kidney (group 2) or SWL to the denervated kidney (group 3). Bilateral renal function was again measured 1 and 4 h after SWL. Both kidneys were then removed for analysis of norepinephrine content to validate the denervation. Renal plasma (RPF) flow was significantly reduced in shocked innervated kidneys (group 2) and shocked denervated kidneys (group 3). RPF was not reduced in the unshocked denervated kidneys of group 2. These observations suggest that renal nerves play a pivotal role in modulating the vascular response of the contralateral unshocked kidney to SWL, but only a partial role, if any, in modulating that response in the shocked kidney.

Animals↗

Randall's plaque of patients with nephrolithiasis begins in basement membranes of thin loops of Henle.

Our purpose here is to test the hypothesis that Randall's plaques, calcium phosphate deposits in kidneys of patients with calcium renal stones, arise in unique anatomical regions of the kidney, their formation conditioned by specific stone-forming pathophysiologies. To test this hypothesis, we performed intraoperative biopsies of plaques in kidneys of idiopathic-calcium-stone formers and patients with stones due to obesity-related bypass procedures and obtained papillary specimens from non-stone formers after nephrectomy. Plaque originates in the basement membranes of the thin loops of Henle and spreads from there through the interstitium to beneath the urothelium. Patients who have undergone bypass surgery do not produce such plaque but instead form intratubular hydroxyapatite crystals in collecting ducts. Non-stone formers also do not form plaque. Plaque is specific to certain kinds of stone-forming patients and is initiated specifically in thin-limb basement membranes by mechanisms that remain to be elucidated.

Adult↗

Stone fragmentation during shock wave lithotripsy is improved by slowing the shock wave rate: studies with a new animal model.

PURPOSE: The current trend toward ungated shock wave lithotripsy means that more patients are being treated with shock waves delivered at a rapid rate (120 shock waves per minute or greater). However, no benefit of an increased shock wave rate has been shown and in vitro studies indicate that slowing the shock wave rate actually improves stone fragmentation. We tested the effect of the shock wave rate on stone comminution in a new animal model. MATERIALS AND METHODS: Gypsum model stones were inserted via upper pole percutaneous access into the lower pole calix of the kidneys of female pigs weighing approximately 100 pounds. Shock wave lithotripsy was performed (400 shock waves uninterrupted at 20 kV. and 30 or 120 shock waves per minute) 2 hours later using an unmodified HM3 lithotriptor (Dornier Medical Systems, Marietta, Georgia). After en bloc excision of the urinary tract stone fragments were collected and sieved through 2 mm. mesh. The particles were weighed and surface area was determined. RESULTS: Stones treated at 30 shock waves per minute broke more completely than stones treated at 120 shock waves per minute. The percent of fragments greater than 2 mm. was significantly higher for stones treated at the fast rate of 120 versus the slow rate of 30 shock waves per minute (mean +/- SEM 81% +/- 14% versus 45% +/- 12%, p <0.005). When stone fragmentation was expressed as the percent increase in fragment surface area, significantly greater fragmentation occurred at the slower than at the more rapid rate (327% +/- 63% versus 135% +/- 136%, p <0.02). CONCLUSIONS: Slowing the rate of shock wave administration during shock wave lithotripsy significantly improves the efficiency of stone fragmentation in vivo.

Animals↗

Multilayered small intestinal submucosa is inferior to autologous bowel for laparoscopic bladder augmentation.

PURPOSE: Bladder augmentation is most commonly performed with ileum. However, porcine small intestinal submucosa has been reported as a substitute for bowel for incorporation into the urinary tract. We assessed the feasibility and long-term 12-month results of laparoscopic bladder augmentation with ileum or multilayered small intestinal submucosa (Cook Biotech, Spencer, Indiana) in a porcine model. MATERIALS AND METHODS: We performed laparoscopically assisted hemicystectomy and bladder augmentation in 24 female Yucatan mini-pigs using an ileal segment (12) or multilayered small intestinal submucosa (12). The followup protocol included anesthetic bladder capacity, renal ultrasonography and serum chemistry. At 3, 6 and 12 months, respectively, 4 animals per group were scheduled for sacrifice and pathological analysis. RESULTS: Despite longer anastomotic time in the multilayered small intestinal submucosa group (120 versus 91 minutes, p = 0.026) total operative time was similar in the 2 groups. In each group bladder capacity increased with time but by 12 months bladder capacity was significantly better in the bowel than in the small intestinal submucosa group (825 versus 431 cc, p = 0.016). At 3 months pathological evaluation revealed that the multilayered regenerated bladder patch had shrunken and by 6 months it was replaced by dense calcified scar tissue. Long-term 6 and 12-month bladder capacity in the small intestinal submucosa group was the result of the regeneration of native bladder with exclusion of the whole multilayered patch in the majority of cases. CONCLUSIONS: Laparoscopic bladder augmentation using multilayered small intestinal submucosa produced functional and pathological results inferior to those of bowel at 12-month followup in a porcine model.

Animals↗

Major complications in 213 laparoscopic nephrectomy cases: the Indianapolis experience.

PURPOSE: We assessed the incidence of and analyzed factors that may help prevent major complications and open conversion during laparoscopic nephrectomy at our institutions. MATERIALS AND METHODS: We retrospectively analyzed all laparoscopic nephrectomies performed between August 1, 1999 and July 31, 2001. Data were stratified for nephrectomy type, intraoperative and postoperative complications. Conversion to open surgery was stratified for emergency versus elective procedures. RESULTS: Of the 292 laparoscopic procedures performed at our institutions in 2 years 213 (73%) involved laparoscopic nephrectomy, including 84 live donor nephrectomies, 61 radical nephrectomies, 55 simple nephrectomies and 13 nephroureterectomies. A total of 16 major complications (7.5%) occurred, including access related, intraoperative and postoperative complications in 3, 9 and 4 cases, respectively. The conversion rate was 6.1% (13 patients), the transfusion rate was 1.9% and the mortality rate was 0.5% (1 death). Only 1 complication was related to simple laparoscopic nephrectomy, although this group showed the highest rate of elective conversion (7 of 8 elective conversions). Laparoscopic live donor nephrectomy showed the highest rate for emergency conversion (3 of 5 emergency conversions). CONCLUSIONS: Our results reinforce the importance of thorough preoperative imaging, careful patient selection, surgeon experience and skill maintenance in laparoscopy as well as a low threshold for conversion to open surgery. This series provides additional evidence to support the evolution of laparoscopic nephrectomy into a standard of care.

Adult↗

Manual specimen retrieval without a pneumoperitoneum preserving device for laparoscopic live donor nephrectomy.

PURPOSE: We present a novel method of kidney retrieval based on a modified Pfannenstiel incision and insertion of the assistant hand into the abdominal cavity without a device for pneumoperitoneum preservation. This maneuver is performed as the last step in pure laparoscopic live donor nephrectomy. Also, we assessed the effect of this technique on warm ischemia time compared with the standard laparoscopic bag retrieval technique. MATERIALS AND METHODS: A total of 70 laparoscopic live donor nephrectomies were performed at our institutions between October 1998 and March 2001. The first 43 cases were completed using an EndoCatch bag device (Auto Suture, Norwalk, Connecticut) for specimen retrieval, while the last 27 were done using a novel manual retrieval technique through a modified Pfannenstiel incision. We retrospectively analyzed the results in regard to warm ischemia time and intraoperative complications related to the procedure. RESULTS: A statistically significant difference was noted in the EndoCatch and manual retrieval groups in regard to warm ischemia time (p <0.001). There were 2 complications related to the EndoCatch device and none related to the manual technique. No differences were detected regarding recipient outcomes. CONCLUSIONS: Manual specimen retrieval after live donor nephrectomy allows shorter warm ischemia time, while saving the cost of an EndoCatch bag or pneumoperitoneum preserving device that would be used during hand assisted live donor nephrectomy. It was shown to be a safe method without increased donor morbidity.

Humans↗

Urinary calculus containing gas.

The combination of gas in the upper urinary tract along with renal calculi has been reported in the setting of emphysematous renal infections, urinary tract instrumentation, and urinary-gastrointestinal fistulas. We present a case of a 46-year-old nondiabetic man with the isolated finding of a gas-containing renal calculus. The significant history in this case included recurrent urinary tract infections and primary hyperparathyroidism with persistent hypercalcemia despite previous parathyroid explorations. The patient was treated with oral antibiotics and rendered stone and infection free by percutaneous nephrolithotomy. The stone culture was negative, and the stone analysis revealed 100% hydroxyapatite.

Durapatite↗

One versus two proficient laparoscopic surgeons for laparoscopic live donor nephrectomy.

OBJECTIVES: To compare the laparoscopic donor nephrectomy (LDN) results obtained by two different surgical teams, one consisting of a proficient laparoscopic surgeon assisted by an inexperienced laparoscopic surgeon and another consisting of two proficient laparoscopic surgeons. With more centers embarking on LDN programs, it is important to identify the factors that can improve overall outcomes during the initial learning curve. METHODS: A retrospective review was performed of the initial 70 sequential LDNs performed between October 1998 and March 2001 at our institutions. The procedures were stratified into two groups. Group 1 consisted of LDN cases performed by one proficient laparoscopic surgeon and an inexperienced laparoscopic surgeon (resident, fellow, or faculty) as the first assistant; group 2 consisted of cases performed by two proficient laparoscopic surgeons. RESULTS: Twenty-six LDNs were performed by group 1 and 44 by group 2. The total operative time and estimated blood loss showed a statistically significant decrease in group 2 compared with group 1, 143 +/- 32 minutes versus 218 +/- 38 minutes (P <0.001) and 92 +/- 115 mL versus 158 +/- 148 mL (P = 0.044), respectively. Two major complications occurred in group 1 (7.7%) and two major complications occurred in group 2 (4.5%). The 3-month postoperative recipient creatinine levels were similar for both groups, 1.6 +/- 1.3 versus 1.4 +/- 0.4 (P = 0.408). CONCLUSIONS: A surgical team composed of two proficient laparoscopic surgeons during the early learning curve of LDN may allow safe and efficient development of a laparoscopic live donor renal transplantation program.

Clinical Competence↗

Laparoscopic treatment for ureteropelvic junction obstruction.

OBJECTIVES: To assess retrospectively the subjective and objective outcomes achieved after laparoscopic treatment for ureteropelvic junction obstruction at our institutions. METHODS: Between August 1999 and July 2001, 19 patients (11 women and 8 men), with a mean age of 31.2 years (range 17 to 67), underwent laparoscopic treatment for ureteropelvic junction obstruction. Of these, 17 patients were eligible for postoperative analysis. Nine of these patients had a history of prior surgical intervention on the affected side. The patients were subjectively assessed by an analog pain scale performed before and at least 6 months after surgery. Preoperatively, patients had a diuretic renal scan to confirm the presence of obstruction. Helical computed tomography was also performed preoperatively to assess for the presence of crossing vessels. The renal scan was repeated at least 12 weeks after surgery to document the relief of obstruction objectively. RESULTS: Helical computed tomography correctly predicted the presence of crossing vessels in 12 patients (63%). The Anderson-Hynes and Fenger pyeloplasty techniques were performed in 16 and 2 patients, respectively. In 1 patient, a small crossing vein over the ureteropelvic junction was identified and divided without complications. The average operative time was 240 minutes (range 128 to 470). The blood loss was minimal, and no open conversions were required. The mean hospital stay was 2.9 days (range 2 to 7). Two postoperative complications occurred (11.7%). The average subjective follow-up was 14.4 months (range 6 to 27), and the average objective follow-up was 7.8 months (range 3 to 12). Of 17 assessable patients, 16 (94%) had subjective and objective success (postoperative improvement in analog pain score and half-life of radiotracer washout). The average split renal function improved from 34.1% to 38.5% (P <0.01). CONCLUSIONS: On the basis of our data, laparoscopic pyeloplasty has a similar success rate compared with the traditional open approach and better results than other minimally invasive techniques. Longer follow-up and further experience are needed to validate these data.

Adolescent↗

Percutaneous stone implantation in the pig kidney: a new animal model for lithotripsy research.

PURPOSE: This report describes a new animal model for research on the parameters of shockwave delivery and the mechanisms of shockwave action in SWL. MATERIALS AND METHODS: Female pigs (approximately 45 kg) were anesthetized for creation of an upper pole peripheral caliceal access. The tract was dilated with a 30F Nephromax balloon and Amplatz sheath, and a 24F rigid nephroscope was used to guide a gypsum artificial stone into a lower pole calix. An internal ureteral stent was then placed. After a 2-hour recovery period, lithotripsy was performed using an unmodified Dornier HM3 lithotripter. Following SWL, en bloc excision of the urinary tract was performed, and the stone fragments were collected. RESULTS: As observed by nephroscopy, most stones were surrounded by urine that was free of clot or debris. Urine output was >1 mL/kg per minute by the time the animal was positioned for SWL after a 2-hour observation period. When the conditions of shockwave (SW) exposure were 400 SWs, 20 kV, and 120 SW/min, the efficiency of stone fragment recovery was 85% +/- 2% (N = 6 stones). CONCLUSIONS: This procedure provides a minimally invasive method for placement of model stones of clinically relevant size within the pig kidney. Stone implantation is efficient and permits experiments to be conducted in 1 day. Stone fragmentation can be quantitated, and the animal can serve as its own control. Long-term experiments are also feasible. Overall, this new animal model is appropriate for experimentation on the parameters of SW delivery in SWL.

Animals↗

The effect of rate of shock wave delivery on the efficiency of lithotripsy.

PURPOSE OF REVIEW: The potential mechanisms of a shock wave rate effect are reviewed here, together with a report on the results of in-vitro, in-vivo and clinical studies that have assessed the effect of altering the shock wave rate on stone breakage and tissue injury by shock wave lithotripsy. RECENT FINDINGS: The vast majority of studies assessing shock wave rate have reported improved stone fragmentation and a reduction in shock wave lithotripsy-induced tissue damage with slower rates of shock wave delivery. However, the optimal shock wave rate has not been determined. SUMMARY: Slower rates of shock wave lithotripsy appear to improve the efficiency of this approach and therefore this suggests the need for a randomized clinical trial to assess shock wave rate.

Animals↗

High resolution detection of internal structure of renal calculi by helical computerized tomography.

PURPOSE: There is considerable interest in using radiological imaging to predict kidney stone fragility before patient treatment. Case series of shock wave lithotripsy show that shock wave lithotripsy is repeated and/or ancillary procedures are done to remove shock wave resistant stones in a significant number of cases. If the fragility of stones were predicted at diagnosis, unnecessary shock wave treatment would be avoided. However, plain radiography allows little discrimination of stone type and simple numerical analysis of computerized tomography (CT) images by measuring Hounsfield units has been shown to be limited in its ability to predict stone fragility. MATERIALS AND METHODS: Urinary stones of known composition were imaged by helical CT in vitro at various slice widths and the images were assessed using a range of window settings. RESULTS: Visualization of stone structure was greatly enhanced using bone windows and a narrow slice width. Surface structure, such as crystalline leaves of calcium oxalate dihydrate, and internal structure showing the heterogeneity of composition or cracks were detected. Stones of similar mineral composition differed dramatically in terms of CT visible structure. CONCLUSIONS: Using a narrow slice width and bone windows greatly improves the visualization of kidney stone structure on helical CT. These results open up new possibilities for determining the relationship of stone structure and fragility for shock wave lithotripsy.

Humans↗

The use of blunt-tipped 12-mm trocars without fascial closure in laparoscopic live donor nephrectomy.

OBJECTIVES: Blunt-tipped trocar placement may eliminate the need for fascial closure in transperitoneal laparoscopic live donor nephrectomies (LDN). The process of 12-mm blunt-tipped trocar insertion through the abdominal wall involves fascial and muscle spreading, not incision. Coaptation of the tissue layers occurs during withdrawal of the trocar, preventing volume gaps that can be prone to herniation. METHODS: We retrospectively assessed the safety and efficacy of fascial nonclosure after 12-mm blunt-tipped port insertion in 70 transperitoneal LDNs performed between October 1998 and March 2001. Five ports (two 12-mm blunt-tipped and three 5-mm blunt-tipped) were used in all cases. The 12-mm trocars were inserted at the lateral border of the rectus muscle, approximately 8 cm below the costal margin and also along the anterior axillary line approximately 8 cm below the costal margin. Fascial non-closure was performed in all 70 patients. Postoperative data were analyzed regarding complications and long-term outcomes. RESULTS: Three major and 7 minor complications occurred in this series. No patient developed clinically detectable trocar-site hernias or other complications related to blunt-trocar placement. CONCLUSIONS: Our data shows that fascial nonclosure after transperitoneal 12-mm blunt-tipped trocar insertion is safe. Visualization of the tissue layers during port placement facilitated the insertion process. Further application of this method in a larger number of patients is needed to confirm its clinical applicability.

Adult↗

Shock wave lithotripsy monotherapy for renal calculi.

Shock wave lithotripsy (ESWL) remains the most common treatment for renal calculi. In this article, recent literature pertaining to ESWL monotherapy of renal calculi was reviewed, with the goal of improving ESWL results through better case selection. When selecting the optimal surgical approach for a patient, multiple factors must be considered. Factors to consider include stone-related factors (size, number, composition and location), renal anatomical factors, and patient-related factors. Each of these factors is presented in detail, with the discussion limit to non-staghorn renal calculi. Children, the elderly, patients with hypertension, and patients with impaired renal function, may be at increased risk of ESWL complications and adverse effects and care should be taken to limit the number and energy of shock waves applied in these special cases. Absolute contraindications to ESWL remain pregnancy, distal obstruction, untreated infection, and uncorrected coagulopathy.

Journal Article↗

Comparison of laparoscopic live donor nephrectomy versus the traditional open technique.

OBJECTIVES: Laparoscopic live donor nephrectomy (LDN) is a minimally invasive technique for kidney procurement that may decrease the donor disincentives. In addition, recent studies have demonstrated that LDN has equal graft and recipient survival when compared to the standard open approach. We report our experience with LDN and compare the results with the most recent open donor nephrectomy (ODN) group performed at our institutions. MATERIAL AND METHODS: The records of 70 consecutives left sided LDN performed between October 1998 and March 2001 were retrospectively reviewed and compared to 40 ODN performed between April 1996 and January 2000. RESULTS: Average blood loss (127 ml vs. 317 ml; p < 0.001), time to PO intake (25 hrs vs. 34.6 hrs; p < 0.001), and hospital stay (2.7 d vs. 4.2 d; p < 0.001) were statistically significant better for the LDN group when compared to ODN group. The average warm ischemia time in the LDN group was 138 seconds (range 55 - 360). The major complication rate in both laparoscopic (4 cases) and open (2 cases) donor groups was similar (5.7% and 5%, respectively). The average post-operative day (POD) 90 recipient creatinine was similar for both groups (1.5+/-0.9 vs. 1.5+/-0.8 ng/dL; p= 0.799). Similar rates of recipient ureteral complications occurred in the LDN and ODN groups: 1.4% (1 case) and 2.5% (1 case), respectively. Likewise, acute rejection was also similar at 22.8% (16 cases) and 27.5% (11 cases) in the LDN and ODN respectively. CONCLUSIONS: At our institutions, LDN was superior to ODN with regards to donor operative blood loss, time to PO intake, and length of hospital stay. In addition, similar complication rates, and 3-month recipient kidney function were demonstrated.

Journal Article↗