Correlation of aberrations with visual symptoms using wavefront analysis in eyes after laser in situ keratomileusis.

PURPOSE: To evaluate the information assessed with the Alcon LADARWave wavefront measurement device and correlate it with visual symptoms in eyes previously treated with laser in situ keratomileusis (LASIK), and to analyze the influence of scotopic pupil size on visual symptoms. METHODS: One hundred and five eyes of 58 patients who underwent LASIK were evaluated. Wavefront measurements were assessed using the Alcon LADARWave device. Visual symptoms were correlated to higher order aberrations in three different pupil sizes (5 mm, 7 mm, and scotopic pupil size). Generalized estimating equations were used for statistical analysis. RESULTS: In eyes after LASIK, visual symptoms analysis showed positive correlation of double vision with total coma and with horizontal coma for the 5-mm and 7-mm pupil sizes, negative correlation between starburst and total coma for the 7-mm pupil size, positive correlation of double vision with horizontal coma, and glare and starburst with spherical aberration and with total aberrations. Scotopic pupil size had a positive association with starburst and negative association with double vision. CONCLUSION: The LADARWave wavefront measurement device is a valuable diagnostic tool in measuring ocular aberrations in eyes after LASIK. A strong correlation between visual symptoms and ocular aberrations, such as monocular diplopia with coma, and starburst and glare with spherical aberration, suggest this device is valuable in diagnosing symptomatic LASIK-induced aberrations. Horizontal coma was correlated with double vision, while vertical coma was not, demonstrating a greater sensitivity with horizontally oriented multifocality.

Adult↗

LADARWave wavefront measurement in normal eyes.

PURPOSE: We evaluated the correlation of Alcon LADARWave wavefront measurements with clinical refraction and corneal topography. METHODS: In a retrospective, non-comparative case series, 60 eyes (30 patients) of healthy individuals evaluated by preoperative examination for refractive surgery were enrolled (manifest sphere, -11.00 to +4.50 D; manifest cylinder, 0 to -4.75 D; 45 eyes were myopic, 12 eyes were hyperopic, and 3 had mixed astigmatism). Correlation of manifest refraction, cycloplegic refraction, and topographic data with wavefront refraction and higher order aberration was assessed. Match percentage given by the wavefront was analyzed. This number represents how much of the wavefront refraction is due to sphere and cylinder (high percentage match) or is influenced by higher order aberration (low percentage match), in which case aberrometer refraction will not be close to phoropter refraction. Pearson's correlation coefficient was assessed for two continuous variables, adjusting for repeated measurements. RESULTS: The median match percentage was 91%. Mean values for all higher order aberration components in a 7.0-mm pupil were: coma = 0.35 +/- 0.29 microm, spherical aberrations = 0.36 +/- 0.31 microm, and other terms of higher order aberrations = 0.31 +/- 0.14 microm. Wavefront sphere, cylinder, and axis terms were highly correlated to manifest and cycloplegic measurements. The high match subgroup had a higher correlation coefficient than the low match subgroup for refraction. Topographic cylinder and axis were not strongly correlated to wavefront refraction, but manifest axis was significantly correlated to topographic axis. CONCLUSION: In 60 normal eyes, the Alcon LADARWave wavefront measurement was highly correlated with refraction, but less well with corneal topography.

Adult↗

Wavefront-guided surface ablation with prophylactic use of mitomycin C after a buttonhole laser in situ keratomileusis flap.

PURPOSE: To describe the surgical outcome of a patient who had a previous buttonhole after laser in situ keratomileusis (LASIK) and 3 months later, had wavefront-guided photorefractive keratectomy (PRK) with topical mitomycin C 0.02%. METHODS: A 38-year-old man underwent bilateral LASIK for correction of myopic astigmatism. A buttonhole in his right eye LASIK flap occurred, but the surgeon decided to proceed with ablation due to the small size of the buttonhole. After LASIK, the patient complained of monocular diplopia in his right eye with 20/30 best spectacle-corrected visual acuity. Wavefront analysis showed a large amount of higher order aberrations, especially coma. Slit-lamp examination revealed a moderate buttonhole scar. Three months after LASIK, the patient underwent wavefront-guided PRK with application of topical mitomycin C 0.02% on the stromal bed, for a duration of 2 minutes. RESULTS: One month after wavefront-guided PRK, his uncorrected visual acuity was 20/25 in the right eye, with no symptoms. Best spectacle-corrected visual acuity in the right eye was 20/15 with +0.25 -0.50 x 110 degrees. No haze or scar was seen on slit-lamp examination. Wavefront analysis showed a decrease in higher order aberrations, especially coma and spherical aberration. CONCLUSIONS: Wavefront-guided PRK with prophylactic topical mitomycin C was effective in treating a patient with visual symptoms and loss of BSCVA after a LASIK flap buttonhole. No delayed epithelial healing, side effects or complications were noted due to mitomycin C.

Adult↗

Monovision laser in situ keratomileusis for pre-presbyopic and presbyopic patients.

PURPOSE: To evaluate the outcome and success of refractive surgery in pre-presbyopic and presbyopic patients with monovision after laser in situ keratomileusis (LASIK). METHODS: We performed a retrospective analysis of 748 eyes of 374 patients over 35 years of age treated in one or both eyes for a monovision outcome using the Alcon LADARVision 4000 laser. Analysis of age at the time of surgery, gender, bilateral versus unilateral treatment, targeted outcome, and patient acceptance are reported. RESULTS: The success rate of monovision patients in this study was 92.5%. Acceptance rate was higher in older patients, although there was no significantly greater acceptance of monovision for any of the variables studied (P values >.26). CONCLUSIONS: Monovision is a valuable option for pre-presbyopic and presbyopic patients considering refractive surgery.

Adult↗

Wavefront aberrations associated with the Ferrara intrastromal corneal ring in a keratoconic eye.

PURPOSE: To describe the optical implications of the aberration pattern of a keratoconic eye implanted with an intrastromal corneal ring (Ferrara ring). METHODS: A 32-year-old man with bilateral keratoconus had a Ferrara intrastromal corneal ring implanted in his right eye. Surgery was uneventful and both uncorrected (UCVA) and best spectacle-corrected (BSCVA) visual acuity improved. Corneal topography was performed before and after surgery. Wavefront measurements were performed 1 month after the procedure in both eyes for comparison. The point spread function, modulation transfer function (MTF), and convolved acuity chart were analyzed. RESULTS: The right eye--implanted with the intrastromal Ferrara ring--had high root-mean-square (RMS) values for higher order aberrations. The left eye-keratoconus without an intrastromal ring-had moderate values. Point spread function, MTF, and convolution acuity charts are presented for each eye, with the latter two showing improved visual function in the implanted eye, despite a higher aberration value. CONCLUSION: The wavefront measurement device captured aberrations even in a highly aberrated eye. Despite better UCVA and BSCVA, the Ferrara ring notably increased higher order aberrations compared to the fellow eye, but with a more uniform central pattern. In this case, the larger RMS value was a poor predictor of good visual function; other metrics better predicted the patient's subjective response. Metrics other than RMS error may be necessary to better correlate aberration value with visual satisfaction in some eyes.

Adult↗

Flap-induced and laser-induced ocular aberrations in a two-step LASIK procedure.

PURPOSE: To identify aberrations created by making a laser in situ keratomileusis (LASIK) flap and treating the refractive error with laser ablation at a later date. METHODS: Twenty-two eyes (11 patients) underwent a two-step LASIK procedure with the Alcon LADAR-Vision laser (Alcon Laboratories, Ft Worth, Tex). In the first step, a flap was created, and 1 month later the flap was lifted and laser ablation performed. Aberrations were measured with the LADARWave wavefront measurement device preoperatively, after making the flap (1 day, 1 week, 1 month) and after laser treatment (1 week and 3 months). Two different microkeratomes were used (Moria M2 [Moria; Antony, France] and SKBM [Alcon]). With the SKBM, all flap hinges were nasal; with the Moria M2, the flap hinge was randomly selected as superior in one eye and nasal in the other. RESULTS: A slight hyperopic shift was seen in the manifest and wavefront refractions at 1 week and 1 month after flap creation for the Moria M2, but not for the SKBM. Statistically significant change in manifest sphere with the Moria M2 showed a mean shift at 1 month of +0.50 +/- 0.08 diopters (D) whereas the SKBM showed no mean shift, but less reproducibility, +0.06 +/- 0.17 D. Higher order aberrations after flap creation were statistically significantly higher for all except coma with both microkeratomes, but with no predictable trends observed. Although higher in magnitude, post flap aberrations were less than one quarter the increase noted in post laser aberrations, except for "other terms." CONCLUSIONS: Creating a LASIK flap induces changes in lower and higher order ocular aberrations. The change in lower order terms is microkeratome dependent. Higher order aberrations increase to a much larger degree after laser than after flap, making a two-step procedure unnecessary in conventional LASIK.

Adult↗

Technological improvements with the Alcon LADAR 6000 excimer laser platform.

PURPOSE: To outline the technological improvements seen in the new Alcon LADAR 6000 laser. METHODS: New LADAR 6000 features can be categorized into three areas: automation, speed, and control. RESULTS: Automation features include auto-registration, specialized illumination, scleral vessel registration, and automated prompting. Speed features include a faster ablation rate and less intensive maintenance. Control features include autoregistration, a better graphic user interface, and an improved workspace. CONCLUSIONS: The technological improvements of the LADAR 6000 help eliminate the variability of measurement, alignment, and delivery needed to optimize custom laser vision correction outcomes.

Cornea↗

Alcon CustomCornea wavefront-guided retreatments after laser in situ keratomileusis.

PURPOSE: To evaluate the outcome of wavefront-guided ablations for the correction of residual myopia and astigmatism after standard laser in situ keratomileusis (LASIK). METHODS: Twenty nine eyes of 26 patients who underwent wavefront-guided LASIK retreatment with Alcon CustomCornea (Alcon Laboratories Inc, Fort Worth, Tex) were evaluated. Complete ophthalmologic examination, corneal topography, and wavefront measurements were performed. Uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), manifest refraction, and wavefront analysis were evaluated preoperatively, 1 week, 3 months, and 6 months after surgery. Wavefront measurements were assessed using the LADARWave device. Statistical analysis was performed using the McNemar test and percentages of success. RESULTS: One week postoperatively, UCVA was > or =20/40 in 100% of eyes (> or =20/20 in 31%) and BSCVA was > or =20/40 in 100% (> or =20/20 in 73%). Wavefront analysis showed a decrease in total aberrations, high order aberrations, defocus, coma, spherical aberration, and other terms of higher order aberrations at 1-week follow-up. Three months postoperatively, UCVA was > or =20/40 in 100% of eyes (> or =20/20 in 38%) and BSCVA was > or =20/40 in 100% (> or =20/20 in 81%). Six months postoperatively, UCVA was > or =20/40 in 100% of eyes (> or =20/20 in 60%) and BSCVA was > or =20/40 in 100% (> or =20/20 in 90%). Wavefront analysis showed decrease in total aberration, high order aberration, defocus, coma, and spherical aberration. CONCLUSION: Wavefront-guided LASIK retreatment in post-LASIK eyes represents a good option for laser vision correction. All eyes showed reduction in pre-existing total aberrations. Some high order aberration components decreased in this initial series. Further follow-up is necessary to assess the initial predictability of wavefront-guided LASIK upgrade.

Adult↗